Measuring the speed of light

Similar documents
PHYS 1112L - Introductory Physics Laboratory II

3.003 Lab 3 Part A. Measurement of Speed of Light

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

Exp. No. 13 Measuring the runtime of light in the fiber

The 34th International Physics Olympiad

SECOND HARMONIC GENERATION AND Q-SWITCHING

2. Refraction and Reflection

Speed of light E Introduction

Speed of Light in Air

Lloyd s Mirror. Understand the nature of sound-waves. Calculate the frequency of ultrasonic sound-waves by Lloyd s Mirror Interference.

Single-Slit Diffraction. = m, (Eq. 1)

6 Experiment II: Law of Reflection

Ultrasonics. Introduction

SPRAY DROPLET SIZE MEASUREMENT

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

Optical Pumping Control Unit

I = I 0 cos 2 θ (1.1)

7 WAVEMETER PROJECT #6 MODEL OEK-100. Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers

Polarization Experiments Using Jones Calculus

AP Physics Problems -- Waves and Light

Experimental Question 2: An Optical Black Box

Determination of Focal Length of A Converging Lens and Mirror

3B SCIENTIFIC PHYSICS

HUYGENS PRINCIPLE AND INTERFERENCE

PHYS 1112L - Introductory Physics Laboratory II

Real-time Laser Beam Position Detector. XY-4QD User Manual

End-of-Chapter Exercises

7. Michelson Interferometer

Speed of Sound in Air

Fabry Perot Resonator (CA-1140)

Two Slit Interference PRECAUTIONS

LO - Lab #05 - How are images formed from light?

Physics 248 Spring 2009 Lab 1: Interference and Diffraction

General Physics Experiment 5 Optical Instruments: Simple Magnifier, Microscope, and Newtonian Telescope

Physics 4C Chabot College Scott Hildreth

Oscilloscope Measurements

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

3B SCIENTIFIC PHYSICS

Experiment P58: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Physics 4BL: Electricity and Magnetism Lab manual. UCLA Department of Physics and Astronomy

Light Waves. Aim: To observe how light behaves and come up with rules that describe this behavior.

Proximity sensors. Inductive. Connection. magnetic. Festo Didactic Training and Consulting Sensors

Reflection of Light, 8/8/2014, Optics


Activity P35: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Intermediate 2 Waves & Optics Past Paper questions

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

General Physics Laboratory Experiment Report 2nd Semester, Year 2018

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Experiment-4 Study of the characteristics of the Klystron tube

Cable Tray Kit: - Cable Tray - Cable Tray Cover - Power Block Support (x2) Top Support Kit: (x2) - 2 Top Supports. Quantities are per bench

The knowledge and understanding for this unit is given below:

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

Lab 5: Brewster s Angle and Polarization. I. Brewster s angle

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Stability of a Fiber-Fed Heterodyne Interferometer

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Lenses. Optional Reading Stargazer: the life and times of the TELESCOPE, Fred Watson (Da Capo 2004).

Technical Explanation for Fiber Sensors

Modern Physics Laboratory MP4 Photoelectric Effect

A Method of Directly Measuring the Speed of Light Using Different Optical Path Lengths

Low Vibration, Low Thermal Fluctuation System for Pulse Tube and Gifford- McMahon Cryocoolers

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:

Ph 3455 The Franck-Hertz Experiment

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Lab 11: Lenses and Ray Tracing

Experiment 10. Diffraction and interference of light

First and second order systems. Part 1: First order systems: RC low pass filter and Thermopile. Goals: Department of Physics

Romanian Master of Physics 2017

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers.

Experiment P41: Induction Magnet through a Coil (Photogate, Voltage Sensor)

Experiment 19. Microwave Optics 1

Eric B. Burgh University of Wisconsin. 1. Scope

Photoelectric effect

Microwave Optics. Department of Physics & Astronomy Texas Christian University, Fort Worth, TX. January 16, 2014

Lab 12 Microwave Optics.

MICROWAVE OPTICS. Instruction Manual and Experiment Guide for the PASCO scientific Model WA-9314B G

Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics

Exercise 8: Interference and diffraction

Ocean Optics R-2000 Raman Spectrometer Setup and Operating Instructions Arlen Viste and Deanna Donohoue April 2000 Update 2003, DEW

Kit for building your own THz Time-Domain Spectrometer

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Physics 2310 Lab #2 Speed of Sound & Resonance in Air

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Single Slit Diffraction

LDA Laser-Doppler-Anemometry

Class #9: Experiment Diodes Part II: LEDs

Laser Telemetric System (Metrology)

Exercise 4 - THE OSCILLOSCOPE

WALLY ROTARY ENCODER. USER MANUAL v. 1.0

Physics Spring 2006 Experiment 9 TRAVELING WAVES

18600 Angular Momentum

LOS 1 LASER OPTICS SET

Large Signal Displacement Measurement with an MTI Photonic Sensor Rev B

A Multiwavelength Interferometer for Geodetic Lengths

Department of Electrical and Computer Engineering. Laboratory Experiment 1. Function Generator and Oscilloscope

NCSL International 2995 Wilderness Place, Suite 107 Boulder, Colorado Office: (303) Fax: (303)

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

Transcription:

1 Purpose and comments Determine the speed of light by sending a laser beam through various mediums. Unless you want to see like Helen Keller, do not place your eyes in the beam path. Also, Switch the laser on at least 10 minutes before starting the experiment. 2 Theory 2.1 Speed of light The following scenario is about two light sources inserted in a tube that is evacuated. One is fixed on the surface of the earth and the other is moving in a perpendicular direction from the surface of the earth. Also, we have a fixed satellite above the light sources which will measure the velocity of the incoming light. The satellite records the velocity of both light sources and it determines the velocity of both sources to be the same. This is called the constancy of the speed of light. This only refers to the speed of light in vacuum. The speed of light in different mediums will be separate issue and that is what you will be determining in this experiment. Note, as of January 25, 2016 the current measurement of the speed of light in vacuum is approximately 299,792,458 m/s. (Nothing in life is certain) You will obtain the velocity of light in air. To measure it you need to take into account t and s. Keep in mind what s should be. The velocity of light in water, acrylic glass, or glycerin is determined by comparing it with the velocity you obtain in air. c a (Fig. 1) In measurement 1 the light passes through a medium with a distance of l 1 with a duration of t 1. In measurement 2 there is no medium, so the light travels at a distance of l 2 = l 1 +2 x with the same time. This implies light will take the same duration to travel a distance 2 x + 2l m in air as to travel a distance of 2l m in a medium. With that in mind and the definition of index of refraction then, and n m = (2 x + 2l m) 2l m = ( x + l m) l m (1) c m = c a n m (2) You will need to determine the index of refraction of the different mediums that you will be using. Note, keep in mind the water temperature. 1

Figure 1: Determining the speed of light in water, acrylic glass, glycerin, etc. 3 Tasks and Equipment used In this experiment you will determine the velocity of light in air, water, acrylic glass, glycerin and calculate the refractive index of the various mediums. Miscellaneous items used 2-Screened cable, BNC, l=750 mm Hardware 2 tubes labeled for the different mediums, Track, 2 U-Shaped brackets to hold the mediums. Sensor Speed of light meter. Measuring device Digital Oscilloscope 30 MHz Other measuring devices 1-meter stick, thermometer, small ruler 4 Setup and how the speed of light meter works 2

4.1 Description The light velocity measuring apparatus and the mirror are set up in such a way that the laser beam hits the mirror no matter where along the base the mirror is placed (more detailed directions can be found in the section below). First the socket f emit /1000 is connected to the oscilloscope and the modulation frequency f emit (divided by 1000) is determined. The reason for introducing the fixed factor 1/1000 into the hardware between the modulator and the socket, is that a relatively simple oscilloscope can be used for the task. After determination of the modulation frequency, the two other sockets (f emit -f sync and f rec -f sync ) are connected to the two input channels of the oscilloscope. The frequencies of the emitted and the received signal are also reduced to 50 KHz while conserving their phase relation so that they can be displayed on this type of oscilloscope. 4.1.1 Purpose of the meter The Speed of light meter serves to determine the speed of visible (red) light in air or in transparent liquid or solid media. The light source is a laser diode, the light intensity of which is modulated by a high frequency AC voltage of approximately 50MHz; so that the light beam exhibits time markers. After the light beam has travelled a certain distance, a retro-reflector directs back onto a photodiode. Here it generates an alternating voltage of the same frequency but one that is displaced in phase against the original signal in dependence on the length of the light path. All of the quantities required for the calculation of the speed of light are shown in the display. When various transparent media water, oil, synthetic resin, acrylic glass are brought into the light path, then the change in the speed of light caused by the particular material can be measured. Once the speed of light is known, the same instrument can be used to carry out the distance measurements. 4.1.2 Mode button on the meter The Mode button toggles through the five different instrument modes, or rather the display of them. The particular mode that is active is shown by the LED that lights up red: (a) OFF - This is the initial mode. It is active as soon as voltage is applied to the instrument. The laser is switched off, the digital display shows OFF. (b) (f emit ) - The modulation frequency of the emitted laser light is displayed. (c) φ - In this mode, the phase displacement between the signal emitted and that received is displayed in degrees. The resolution is 1 degree, the value range from 0 to 359 degrees. (d) t 1000 - The transit time of the signal can be directly calculated from the phase displacement and the modulation frequency and be shown here. As the phase displacement is measured by a heterodyne procedure at 1/1000 of the modulation frequency, 1000 times the transit time is to be shown here, so that the impression is not given that measurement is made directly of times in the ns range. (e) x - This mode is suitable for differential distance measurements. Here, the literature value of the speed of light is used internally to calculate the changed distance from 3

the retro-reflector x from the difference in transit times t. In accordance with the modulation frequency of 50MHz and the measurement procedure, x can only be unambiguous in the range from 0 to 2.99m. The resolution of the display is 1cm, the maximum tolerance is 5%. 4.1.3 Calibration button When you press the Calibration button it sets the φ, t 1000 and x starting points for all the measurement. They are set to zero when the laser beam is reflected back to the instrument. The position of the mirror at this point in time is set to the zero point of measurement. The function of this button is in principle comparable to that of a tare button of a digital balance. The setting of the phase difference between the signal emitted and the signal received acts immediately on the signals at the BNC sockets and can also be well measured through an oscilloscope. This procedure must be carried out once after switching the instrument on for measurements to be able to be carried out. When the instrument receives the reflected laser beam, CAL blinks in the digital display, in as much as this had not been previously carried out. 4.1.4 Modulation frequency BNC socket The modulation frequency of the laser light is led to an output reduced by a factor of 1,000, so that it can be measured with a simple oscilloscope. Together with the signals at the other two BNC sockets, this enables measurements to be made that are independent of the values in the digital display. 4.1.5 Signal emitted/signal received BNC sockets These two sockets can be used to evaluate the signal emitted and the signal received by means of a 2-channel oscilloscope. The phases of the two signals relative to each other are of particular importance here. In order not to have to use the fastest oscilloscope for this task, each of the signals are additively mixed with a synchronisation signal that is modulated to a 50kHz lower frequency than that of the laser light. This leads to signals in the 50kHz range whose phase positions relative to each other are the same as those of the original signals, but which can be comfortably evaluated with a normal oscilloscope. 5 Experimental procedures 5.1 Handling and setting up the beam Switch the laser on at least 10 minutes before starting the experiment. This allows thermallycaused fluctuations of the beam which could affect the result of the measurements to be avoided. Position the Speed of light meter on the holder upon the optical bench. The magnetic film on the bottom of the instrument ensures a stable position but does not interfere with the horizontal alignment. Align the instrument and the retroreflector so that the beam strikes the reflector as central. Make sure the beam of the laser stays within the center of the optical track. Use a index card with a hole that is mounted on the holder to check the beam path. 4

5.2 Velocity of light in air At the start the mirror is placed close to the operating unit, the mode φ is selected and the Calibration button is pressed to have two coinciding signals visible on the oscilloscope. (See Fig. 2) Hint, to measure t on the scope you need to hit the Run/Stop button on the scope. After push the cursor button. Figure 2: Oscilloscope signal after Calibration The mirror is then slid along the graduated scale. For at least 10 different displacements x (> 100 cm) the time difference t is calculated from the readings performed on the oscilloscope. (See Fig. 3) Figure 3: Measuring the time difference using the oscilloscope. 5

5.3 The Velocity of light in water, glyercin, and acrylic glass The water-filled tube or the acrylic glass rod is placed so that the laser beam runs through the center of the mediums, the mirror is placed directly behind. The Calibration button is pressed. Again the oscilloscope will show a graph similar to Fig. 2. The tube/rod is then taken out of the path of the laser beams and the two signals will not coincide any longer. Now the mirror is moved a distance x until the two signals on the oscilloscope coincide again as before with the medium inserted. The mirror displacement x is measured several times. 5.3.1 Analysis and questions 1. What is the speed of light in air? 2. What is the speed of light in water and glycerin? 3. What is the speed of light in acrylic glass? 4. Why doe the speed of light in the different mediums? 5. Does the wavelength of the light change in different mediums? Explain. 6. How does the intensity of the light vary in the different materials? Explain. 6 Finishing Up Please return the bench to the condition in which you found it. Thank you. 6