Sierra Series 900 Flo-Box System Unit. Instruction Manual

Similar documents
Flow Totalizer Feature Totalize Multiple Gases with One Mass Flow Meter. Instruction Manual

CBCT TM CIRCUIT BREAKER COIL TESTER

Installation guide 971 SmartRadar LTi

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Cisco Access Points with Smart Antenna Connectors 2

Smartzone LCD TOUCHPAD USER GUIDE.

DR3535 DR3535-O. Hardware Reference Manual. Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION

Installation & Operation Manual

Operating Instructions

OVEN INDUSTRIES, INC. Model 5C7-362

SCHMIDT Flow Sensor SS Quick Guide

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

Desktop/Remote Four-Position Antenna/Transceiver Switch

Version: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual

Digital Readout / Control Systems. > Features. Mechanical: u An overview of the dimensions can be found on the last page.

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

DynaDrive INFORMATION MANUAL SDFP(S)

Actuating Terminal Equipment Controller (ATEC) Base VAV - Cooling or Heating, Application Application Note

Technical Manual. Standard Communication Protocol TA3840C

Model 805 PWM Proportional Valve / Solenoid Driver with Peak and Hold Control Modes

Universal Controller

MFJ ENTERPRISES, INC.

Wireless Rain and Wireless Rain/Freeze Sensor

Electronic Vacuum Regulator. Standard Specifications. Model Voltage

LC8 & LC8-15. Single Level Lighting Controller INSTALLATION AND MAINTENANCE MANUAL (IMM) 205_LC8_R4

Elevation M16 A2-1 click=1 ¼ MOA M4-1 click=2 MOA

User guide. Revision 1 January MegaPoints Controllers

NWS300 Field Type Smart Meter

Optidrive Applications Support Library

PIEXX UX-14(PX) Plus Installation Instructions

Installation, Operation and Maintenance Instructions

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Millermatic 211 Auto-Set w/mvp

Multi-Channel USB RF Transceiver

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

Table of Contents. Safety Notices

Micro Motion Model 2700 Transmitters with Configurable Input/Outputs 2700***B 2700***C. Configuration and Use Manual Supplement

Installation guide 873 SmartRadar Control Unit & Antenna Unit

815LT Submersible Smart Level Transmitter

Hoffman Controls. OEM Installation Manual. Description. Application. Field Recalibration. Features. 744-H, C, HP, CP Series Step Controllers NOTE

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

Installation guide 970 SmartRadar ATi

Exercise 6. Open-Loop Speed Control EXERCISE OBJECTIVE

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Physics Spring 2006 Experiment 9 TRAVELING WAVES

Precalculations Individual Portion Introductory Lab: Basic Operation of Common Laboratory Instruments

TOSVERT VF-PS1 series APOGEE FLN option unit Instruction Manual APG001Z

JPQ2 PULSE ACCUMULATOR

Evolution. EC Motor Series 1. Automation Interface CONTROLS INC. EVO /ECM-ACU+ Application. Ordering

Exercise 2. Point-to-Point Programs EXERCISE OBJECTIVE

BNC-Panel-32-Input User Manual

MSCF-16-LN (Data sheet V5.0_01)

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

DLC-PDC PHOTODIODE CONTROLLER

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

LM125 Precision Dual Tracking Regulator

Directions for Wiring and Using The GEARS II (2) Channel Combination Controllers

Distribution Amplifiers 1

SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101

MSCF-16 F (Data sheet V51_02)

picotalk OPERATING MANUAL V1.2 (May 26, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:

Network Topper. Technical Manual Network Topper PCB Project : Network Topper Revision : 0.2 Company : Suzo International (NL) BV

815PT Smart Pressure Transmitter

1-2 VOLTS PER HERTZ CHARACTERISTICS EXERCISE OBJECTIVE

RT-21 Az-El Controller Manual addendum to RT-21 - August 5, 2014

Armstrong Series GFH UPC Installation IB-536

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

IMPULSE 2-2. pulsed power module operation manual. Models: SF-IMPULSE2GX-SH SF-IMPULSE2GX-DH SF-IMPULSE2KX-SH SF-IMPULSE2KX-DH

PhenoMaster / LabMaster Phenotyping Research Platform

Model PRESET 8 Installation and Operations Manual

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

METEOROLOGICAL INSTRUMENTS

Application Note. Increase Voltage Output of AC Source by paralleling two (2) or Series from 300VAC up to 600VAC.

LIGHT MANAGER // LED LIGHTING POWER SUPPLY

Installation Guide. Overview

Installation guide 970, 971 and 973 series SmartRadar

INSTALLATION, WIRING & CONFIGURATION

SCR CONTROLLER SYSTEM

Installation Guide. Overview

AC Circuits. "Look for knowledge not in books but in things themselves." W. Gilbert ( )

BOILER MANAGEMENT SYSTEM

Operating Guide. HT25 Multi Side Tabber & Stamp Affixer. HASLER America s better choice. Mailing Systems And Solutions

Caution: Installation and Operation Instructions. Locking Mechanism (if supplied) Set Screws Backed Out. Mounting Orientation

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Equipment: You will use the bench power supply, function generator and oscilloscope.

Mate Pilot. Turret Calibration System. Mate Tooling Lasts Longer

RC3000 Antenna Controller Appendix ASC Integrated ASC Beacon Receiver. Appendix ASC. Integrated ASC Beacon Receiver Option

Analog Laser Sensor. Installation Instructions. Specifications. Summary of Changes. Description. Catalog Numbers 45BPD-8LTB1-D5, 45BPD-8LTB2-D5

FX 3U -20SSC-H Quick Start

3PRKA. 3-channel, FHSS Radio control system for Car INSTRUCTION MANUAL 1M23N Digital Proportional R/C System

TECHNICAL BULLETIN. Direct Impulse Control for Einstein RX

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

Transcription:

Series 240/241 Instruction Manual Table of Contents Sierra Series 900 Flo-Box System Unit Instruction Manual Part Number IM-90-FB 07/05 Revision D.1 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com Sierra Instruments b.v. Bolstoen 30A 1046 AV Amsterdam The Netherlands +31(0)20-6145810 Fax +31(0)20-6145815 IM-24-C 0-1

Ratio Control Option Appendix D The constant ratio-control option ( -RC in the model code), provides the user with the ability to set and maintain an exact ratio of gas flow between two (or more) mass flow controllers (MFCs). The control box accomplishes this by scaling the setpoint to the slave controller(s) from the output of the master controller. Thus, even though the ratio can be initially set up without flow, actual operation of the slaves will not occur until a gas flow is established through the master. If the master inadvertently stops flowing (the gas runs out), the slave(s) will close. Thus this feature provides a constant ratio control when gas is flowing correctly, and a safety shut off for the slaves if the master gas runs out. 1. Channel one is typically set up as the master channel and should be cabled to the master controller (see the label on the control box to confirm that channel one matches the range of the master controller) 2. Channel two is typically set up as a slave channel (the channel that you want to follow the master) and should be cabled to the slave controller. If more than one slave is being used, additional channels may be set up at the factory. (It is convenient but not necessary to scale the slave channel(s) in percentage rather than actual engineering units) 3. With the front-panel switch in the Normal position, each channel of the box will function independently to supply command signals to the separate controllers. In the Ratio position, channel one will be the master and the slave channel(s) will follow the lead of the master, using its output signal to establish a setpoint(s). 4. If the constant-ratio feature is to be activated: a. Begin with the front panel switch in the Normal position. (Flow is not needed at this point though it can be done with or without it the controllers don t even need to be connected to the cables) b. Switch the channel dial to channel two (the slave channel). Calculate the percentage at which you want this slave controller to follow the master. With the Set/Read switch in the set position, dial in the flow that corresponds to this percentage. Example #1: The master is scaled for a flow of 0-350, and the slave is also scaled for 0-350. You desire to have the slave follow the master at a 100% flow ratio. In Normal mode, switch the Set/Read to Set and dial in a setpoint of 350 to channel two (it makes no difference what channel one is doing at this point). Since the two controllers are scaled the same, they will always flow the same rate. Example #2: If you desire channel two to follow the master at a ratio of 30%, set channel two to 105 (30% of it s full scale range). Example #3: The master is scaled for a flow of 0-350, and channel two scaled for percentage (0-100). If you desire channel two to follow the master at 65% of the slave s capacity, set channel two to 65. Example #4: Master channel scaled for 0-350, slave scaled for 0-200. You want the slave to follow at 40% of its own capacity. In Normal mode, set channel two to 0.4 X 200, or 80. Now, when the master is flowing 350, the slave will flow 80, and when the master is reduced to a flow of 175, the slave will reduce to a flow of 40. c. Switch the Normal/Ratio switch to Ratio. Now, your ratio feature is scaled and the box is ready to use for a constant ratio application.

d. Turn off the power switch on the front of the box, attach the cables and the controllers (if you haven t already done so), and turn the power on. e. Apply gas pressure to the inlet of the controllers per the operating pressure listed on the labels. f. Box settings: Set/Read to Set, Normal/Ratio to Ratio, Channel knob to Channel 1 (the master channel), and the jumpers (on the back of the box) in the Manual position. g. Dial in the desired flow to control the master controller. The slave(s) will follow at the preset ratio. To see the flows, switch the Set/Read switch to Read and monitor channel one and channel two, confirming that the slave is following the master at the pre-set ratio.