Operation with the Tebis TX100 configurator

Similar documents
User Manual 3X300 DIMMER MODULE DM03B02KNX

Tebis application software

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

STC-KNX (32-channel AP)

K-BUS Switch Actuator

application software

application software

KNX ENO 634 (32-channel AP)

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Unidirectional Gateway EnOcean - KNX/BUS

MDT Switch Actuator/FanCoil

EIB/KNX Switch Actuators. User manual

KNX ENO 620/622 (32-channel AP)

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

application software

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC

Integrations GW Programming manual

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Overview animeo KNX offer

TA-Slider 160 KNX Protocol Implementation

1. Use of the application program

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

KNX manual 1-channel flush-mounted switch actuator SU 1

TA-Slider 160 KNX R24 Protocol Implementation

Fan Coil Actuator FCA 2

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

SeeTool - Solutions for KNX

Installer manual inputs/outputs interface for led KNX

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Instruction manual. art Installation manual

16-Channel Yearly Time Switch TR 648 S DCF

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

animeo KNX 4 DCE Motor Controller WM/DRM V AC Instructions

Quick Start: Radiator Control

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

domovea energy tebis

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual

Technical Manual MDT Air quality/co2 Sensor

animeo KNX 4 DC 2 A Motor Controller WM 24 V DC Installation manual

Application Programs Descriptions

Room thermostat solo, FM Type: 6124-xx

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Instruction Manual. B Series Program Mode (BLDC Servos)

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

KNX S-UP. Actuator for 230 V or 24 V. Installation and Adjustment

KNX Room temperature controller

SRC-110 Series Zone Controllers with Modbus RTU

ET2000e IRRIGATION CONTROLLER

Application Manual KNX fan-coil actuators/controllers EK-HA1-TP EK-HB1-TP EK-HC1-TP

animeo KNX/EIB 4 DC/E Motor Controller WM V AC Installation manual

A U T O E S C M E N U

WIRING DIAGRAMS FOR SMART MODELS

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

Device connection and commissioning can only be carried out by qualified professionals. Always make the connections while the power is switched off.

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

EQJW145. Content: 1 General. 2. Indicators and operating controls 3. Putting into service (by a technician) 4. How to operate (user)

Radio BBC 3 FM BBC R2 BBC R2 BBC 3 FM 99.8 TV DVD AUX

Why does the Output's TesysT not switch on?

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

S! Applications & Widgets

R PROFLAME Instruction Book Collection

INSTAT 868 Radio Frequency Single-Room Controls

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

DEUTSCH NEDERLANDS ENGLISH ESPAÑOL FRANÇAIS PORTUGUÊS DAB2035

DS1720 ECON-Digital Thermometer and Thermostat

Guangzhou Video-star Electronics Industrial Co., Ltd. (Thermostat) User Manuals-Ver. 1 CHTC-86/

USER MANUAL CU-DIN DIM 4-CH 1.5A KNX EC MA

THREE-PHASE ENERGY METER DIRECT CONNECTION PM30D01KNX. User manual

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

Instructions for programming and use Starline Roldeck - floorpanel control RD-2001

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

Modbus communication module for TCX2: AEX-MOD

KNX 4-channel RGBW Dimmer LED module EK-GC1-TP - PWM power outputs EK-GF1-TP V control outputs

The MFT B-Series Flow Controller.

RPS-9000 Programming Software for the TYT TH-9000

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

TAC5 Regulation + SAT KNX Module

Technical Manual MDT LED-Indicator

Operating Instructions. Single SBC-Control Systems. Seite 1 von 13. U:\SINGLE\Regler\SBC\Englisch\SBC_e_Version 2_6.doc

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Fixed Wing Models 55

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

ATP-5189 Programming Software for the Anytone AT-5189

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

AT-5888UV Programming Software for the AnyTone AT-5888UV

KNX ON/OFF controller 4 contacts 16A

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

WCS-D5100 Programming Software for the Icom ID-5100 Data

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

Transcription:

Operation with the Tebis TX100 configurator Heating functions : Heating actuator 6 channels Electrical / Mechanical characteristics : see product user's instructions Product reference Product designation Version TX100 TP device RF device TX 206H Heating actuator 6 channels 1.6.3 TX206H 1 6T7531c

Summary 1. Presentation of the functions of the TX206H... 2 2. Configuration and parameterising of the TX206H... 2 2.1 Teaching the TX206H with the TX100... 3 2.2 Creating a link between an output of the TX206H and a thermostat... 4 2.3 Creating a link between the TX206H heating actuator and a Stop input... 5 3. Expert mode programming... 6 3.1 Objects and functions in the Expert mode... 6 4. Resetting the TX206H to factory configuration.... 8 5. Characteristics... 9 6. Bus presence check (supply voltage)... 9 1. Presentation of the functions of the TX206H The main functions are the following : Valves control The TX206H has 6 outputs. These outputs allow controlling normally closed valves equipped with 24VDC electrothermal motors. The outputs are adapted to the control of heating or air-conditioning systems with water-distribution circuit. Time-proportional control The TX206H receives from the thermostat(s), for each output, the heating rate (%-type value) to be applied. The TX206H converts, on the basis of a 15 min cycle, this %-type value into output opening and closing times. For example, if the thermostat requires a heating rate of 40 %, the valve will be closed for 9 min and then opened for 6 min. Valve protection A valve that remains inoperated for a long time may jam. To prevent if from jamming, the heating actuator integrates a valve protection function. If the output is not actuated (opening of the valve) for more than 24 h, whatever the current mode, it will be actuated automatically for 6 min all 24 h. Stop The Stop mode allows switching the heating actuator completely off (all outputs). The Valve protection function is active during this stop. Bus failure mode A non-adjustable emergency programme will be activated in case of a bus failure. This programme consists in activating successively each of the valves for 8 minutes. For example : channel 1 ON for 8 min (all other channels OFF), then channel 2 ON for 8 min (all other channels OFF), etc. 2. Configuration and parameterising of the TX206H The TX206H is a 6 channels heating actuator. Its main function consists in applying to each of the outputs the heating rate required by the linked thermostat. For that purpose, each of the outputs must be linked to a thermostat by means of the TX100. The Heating OFF input allows switching off all outputs of the product. The user's instructions of the TX100 configurator give all explanations required to set up links. TX 206H 2 6T7531c

2.1 Teaching the TX206H with the TX100 Pressing the key of the TX100 for a long time in Prog mode allows carrying out the learning process on the TX206H. After this learning, the following symbols will be displayed on the right side of the display of the TX100 : - 6 times. Each symbol represents an output of the actuator. Pressing briefly the key will light temporarily the LED corresponding to the output. This function allows finding in the installation the output number of each of the channels. Each of the outputs must be linked to a thermostat. - 1 time. The symbol represents the Stop function. This Stop function allows switching off simultaneously all outputs of the TX206H. As long as the Stop command will be present, the commands issued by the various thermostats will not be applied. 1 Prog 1 1 1 Inputs 6 Outputs Auto All Num X stands for a possible input or output number. The keys allow scrolling the input / output numbers. The key allows toggling between the input number X and the linked function in order to select or modify this function. TX 206H 3 6T7531c

2.2 Creating a link between an output of the TX206H and a thermostat Important information : Creating a link between a thermostat and a heating output is only possible in the Prog/+Info mode of the TX100. To assign a thermostat to an output (heating circuit), it is indispensable to switch the display of the TX100 to the +Info mode. This is done by pressing the central key underneath the display activated.. This operation is not possible while the Expert mode is After activating the Prog/+Info mode, the thermostats are displayed on the right side of the display of the TX100. Prog X X Inputs Auto + info 95 Num Outputs Control output Actuator output X stands for a possible input or output number. To create the link between a thermostat and a channel of the heating actuator : - Use the keys of the TX100 to select the thermostat on the left side of the display. - Use the keys of the TX100 to select the output channel on the right side of the display. - Press to create the link. Function of the input Description Operation Regulation This function must be linked to a -type output. The regulation function allows the thermostat to communicate to the output the heating rate to apply. The thermostat communicates to the output the heating rate to apply (%-type value). Based on a cycle time of 15 min, the TX206H converts the %-type value in ON and in Off switching times. The connected valves will be opened during the ON switchng period and closed during the OFF switching period. TX 206H 4 6T7531c

2.3 Creating a link between the TX206H heating actuator and a Stop input The Stop function allows stopping simultaneously the 6 heating channels of the TX206H and ending all current cycles. The valves connected to the outputs will be closed. To carry out this function, a link must be created between an input with the function. function and the output channel with the X Prog 1 1 X Inputs Auto All Num 6 Outputs Input (switch type) Actuator output X stands for a possible input or output number. To create a link between the TX206H and a Stop input. - Use the keys of the TX100 to select the Stop input on the left side of the display. - Use the keys of the TX100 to select the Stop output on the right side of the display. - Press to create the link. Function of the input Description Operation Stop This function must be linked to a -type output. The Stop function allows stopping simultaneously the 6 heating channels of the TX206H and ending all current cycles. The valves connected to the outputs will be closed. The associated input contact is of a switch type. The closing of this contact will cause the contacts of all the outputs to open. The Heating OFF command has the highest priority. Only a Stop end command allows re-starting the heating. The Valve protection function of the valve remains active. Closing of the contact : Stop of all channels of the TX206H; this command is maintained even in case of a request coming from a thermostat. The Valve protection function remains active. Opening of the contact : The Stop command is cancelled. The outputs apply the commands isued by the thermostats. TX 206H 5 6T7531c

3. Expert mode programming Basic EIB/KNX knowledge (for example, ETS=EIB software) is required to perform programming in the Expert mode. The Expert mode includes the following functions : a. extension of the communication system : grants access to the group address given during programming in Standard mode in order to set up links between a Tebis TX installation (TP,Funk KNX) and Hager products such as technical alarms, display, Internet gateways. b. programming mixed installations (EIB/KNX and Tebis TX) : the Expert mode allows integrating KNX RF products in an installation parameterised with ETS. c. programming additional functions : in order to maintain the ease of programming in Standard mode, certain functions of the product may not be available in this mode. Therefore, certain specific solutions are reserved for the Expert mode. Example of an Expert mode display : Expert Prog 1 5 1 11 Group Adr. 24/4/30 + IOnOff + DimVal ONOFF Info Easy OnOff DimCtrl + DimVal Timer The following pages describe the objects of the 6 heating actuator visible in the Expert mode. For basic information about the operation of the Expert mode, refer to the specific documentation. 3.1 Objects and functions in the Expert mode 3.1.1 Stop function/hvacena object The HvacEna object allows switching off simultaneously all outputs of the TX206H. When receiving this object, the current cycles are stopped and the connected valves are closed The Valve protection function remains active. Tebis TX ETS Application software Function Symbol Designation Object name Format Flags HvacEna Heating Stop 1 Bit CRW-U Value 1 means Stop Value 0 means No Stop TX 206H 6 6T7531c

3.1.2 Priority function/logvalue object There is a Logvalue object for each of the heating outputs of the TX206H. This object allows forcing the stop of the output. In Expert mode, a link can be set up between this object and a binary-type input (e.g.: an input with function). When receiving this object with a 1 value, the current cycle is stopped and the valves connected to this output are closed. The (%-type) commands issued by the thermostat will not be taken into consideration. The Valve protection function remains active. Tebis TX ETS Application software Function Symbol Designation Object name Format Flags Output X LogValue OFF priority 1 Bit CRW-U Value 1 on this object = a stop priority will be activated on the output. Value 0 on this object = no priority, the output is driven by the % command 3.1.3 % Command function/% Value object There is a % Value object for each of the heating outputs of the TX206H. This object allows transmitting to the heating output the command to be applied in the form of a percentage-type value. Tebis TX ETS Application software Function Symbol Designation Object name Format Flags %Value Output X Command % 1 Byte CRW-U output receives the command to be applied (in %) With this object, the heating TX 206H 7 6T7531c

4. Resetting the TX206H to factory configuration. This function allows resetting the product to its original configuration (factory settings). After a device reset, the product can be re-used in a new installation. This function is accessible through the menu Device Management/Reset of the TX100. Two cases may occur : 1 - The product belongs to the installation. Press briefly the key and select the Device Management menu, and then Factory Setting (Reset). The list of the products of the installation is displayed. Select the product in the list. Confirm with, and confirm the cancellation of the product. The product is reset. Back with the key. 2 - The product does not belong to the installation. Press briefly the key and select the Device Management menu, and then Factory Setting (Reset). The list of the products of the installation is displayed. Select not install. Device. Confirm with the key. Select TP. Confirm with the key. Press the physical addressing pushbutton of the TX206H. The physical addressing indicator lights. The product is reset to factory configuration and the indicator goes off. Back with the key. The learning of the whole installation must be carried out to allow using again a product reset to factory configuration. TX 206H 8 6T7531c

5. Characteristics Max. number of group addresses 254 Max. number of links 255 Number of objects 13 6. Bus presence check (supply voltage) To check the presence of the bus, press the physical addressing pushbutton. The physical addressing indicator lights to show the presence of the bus (supply voltage). Pressing again allows switching the indicator off. Important : The physical addressing indicator must be off to allow programming or operating the installation. TX 206H 9 6T7531c