Momentum and Impulse

Similar documents
Momentum and Impulse. Objective. Theory. Investigate the relationship between impulse and momentum.

Activity P07: Acceleration of a Cart (Acceleration Sensor, Motion Sensor)

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Experiment P10: Acceleration of a Dynamics Cart II (Motion Sensor)

INTRODUCTION TO DATA STUDIO

12 Projectile Motion 12 - Page 1 of 9. Projectile Motion

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Computer Tools for Data Acquisition

Resonance Tube Lab 9

Experiment P11: Newton's Second Law Constant Force (Force Sensor, Motion Sensor)

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

Laboratory 1: Motion in One Dimension

2-Axis Force Platform PS-2142

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

Physics activities using the ScienceWorkshop program and interfaces from PASCO scientific

Experiment P01: Understanding Motion I Distance and Time (Motion Sensor)

This manual describes the Motion Sensor hardware and the locally written software that interfaces to it.

18600 Angular Momentum

Experiment P24: Motor Efficiency (Photogate, Power Amplifier, Voltage Sensor)

Faraday's Law. Objective: In today's experiment you will investigate electromagnetic induction and determine the factors that affect it.

Activity P35: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Lab 1. Motion in a Straight Line

Motions and Forces Collision I

Experiment 8: An AC Circuit

Experiment P02: Understanding Motion II Velocity and Time (Motion Sensor)

±50N FORCE SENSOR. Instruction Manual and Experiment Guide for the PASCO scientific Model CI A 6/ PASCO scientific $7.

Single-Slit Diffraction. = m, (Eq. 1)

MicroLab 500-series Getting Started

Experiment 3 Topic: Dynamic System Response Week A Procedure

TM Quick Start Guide

Relationship to theory: This activity involves the motion of bodies under constant velocity.

PHYSICS 220 LAB #1: ONE-DIMENSIONAL MOTION

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

MASSACHUSETTS INSTITUTE OF TECHNOLOGY /6.071 Introduction to Electronics, Signals and Measurement Spring 2006

Experiment P58: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Activity P40: Driven Harmonic Motion - Mass on a Spring (Force Sensor, Motion Sensor, Power Amplifier)

ArbStudio Triggers. Using Both Input & Output Trigger With ArbStudio APPLICATION BRIEF LAB912

An Inclined Plane. Experiment OBJECTIVES MATERIALS

Measuring Distance Using Sound

Voltage Current and Resistance II

Experiment P20: Driven Harmonic Motion - Mass on a Spring (Force Sensor, Motion Sensor, Power Amplifier)

Exercise 4-1. Chaff Clouds EXERCISE OBJECTIVE

Two Dimensional Motion Activity (Projectile Motion)

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

Lab 1B LabVIEW Filter Signal

1503 Follow Spot Yoke, Source Four LED

Lab 5: Brewster s Angle and Polarization. I. Brewster s angle

iphone 6 Chargeport REPAIR GUIDE Version Edition

Thomas S. Narro David Zucker Darren Garnier 4/05. Copyright 2005 CPO Science

Vinyl Cutter Instruction Manual

Lab 2b: Dynamic Response of a Rotor with Shaft Imbalance

Experiment P41: Induction Magnet through a Coil (Photogate, Voltage Sensor)

Free vibration of cantilever beam FREE VIBRATION OF CANTILEVER BEAM PROCEDURE

Photo One Digital Photo Shoots and Edits

Ph 2306 Experiment 2: A Look at Sound

2.4G Wireless FlashTTL Trigger KR-201

Introduction. Theory of Operation

2400AT 4 I221 I221 1A 1A T T Rev. Rev B. C

The Useless Machine. DIY Soldering Edition. Instruction Guide v0004

Sonometer CAUTION. 1 Introduction. 2 Theory

SCATT Biathlon shooting trainer User s Manual

Physics 253 Fundamental Physics Mechanic, September 9, Lab #2 Plotting with Excel: The Air Slide

Lab M6: The Doppler Effect

Name: Lab Partner: Section:

Practicing with Ableton: Click Tracks and Reference Tracks

Codonics SLS 500i Shelf Installation

NeuLog photo gate logger sensor NUL-209

Lab 2: Introduction to Real Time Workshop

75cm ODU/SurfBeam 2 Point and Peak Job Aid

Tauten Tab Tension Screen User Manual

Midi Fighter 3D. User Guide DJTECHTOOLS.COM. Ver 1.03

LabVIEW Day 2: Other loops, Other graphs

ivu Series TG Image Sensor

Katran-Lux. Non-linear junction detector USER MANUAL

Resistance Apparatus EM-8812

Studuino Icon Programming Environment Guide

Diamond Engraving Tool

RG Kit Guidebook ARGINEERING

Physics 131 Lab 1: ONE-DIMENSIONAL MOTION

OPERATIONS MANUAL. Port-O-Slitter

V-MOTION LITE USER GUIDE. Rat Rig All rights reserved.

Experiment: P34 Resonance Modes 1 Resonance Modes of a Stretched String (Power Amplifier, Voltage Sensor)

Android User manual. Intel Education Lab Camera by Intellisense CONTENTS

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

4700/4800 Series. Time Stamp. Handling Manual

Experiment A2 Galileo s Inclined Plane Procedure

Illuminati Wireless Light and Color Meter Model IM100. User Manual

Physics 3 Lab 5 Normal Modes and Resonance

Mobile Cart for Flat Panel Display (PTC-2000 Series)

Experiment A2 Galileo s Inclined Plane Procedure

Oscilloscope. 1 Introduction

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

Spindle Drive Belt - Tension Adjustment - Gates Sonic Meter

P2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT

Procedure, Field Replacement, PCU Kit, XX04

MBM Sprint 3000 Booklet Maker

MultiSensor 6 (User Guide)

FD35EV SLIDING DOOR SYSTEM Installation Manual (One-Way Soft Close, Recessed Mount Roller) Part No.FD35EVHCP

Ohm s Law. Equipment. Setup

Electric Drives Experiment 5 Four-Quadrant Operation of a PMDC Motor

Transcription:

General Physics Lab Department of PHYSICS YONSEI University Lab Manual (Lite) Momentum and Impulse Ver.20180328 NOTICE This LITE version of manual includes only experimental procedures for easier reading on your smartphone. For more information and full instructions of the experiment, see the FULL version of manual. Momentum and Impulse Procedure Experiment 1: Impulse-Momentum Theorem NOTE To mount any accessory to the track, 1 Slide the tap and square nut of the accessory into the T-slot of the track. 2 Tighten thumbscrew (clockwise) to secure it. To demount it, 1 Loosen the thumbscrew (counterclockwise). 2 Remove it with care. When you loosen thumbscrew, NEVER try to completely unscrew it. (It won t be reassembled again!) (1) Set up equipment. (1-1) Install Universal Bracket at the left end of the track. (You will use this accessory in experiment 2.)

(1-2) Install Photogate Bracket at the right end of the track. (You will use this accessory in experiment 2.) (1-3) Mount the Motion Sensor. 1 Mount the Motion Sensor on the left end of the track. 2 Aim the sensor s transducer at the cart (slightly up to avoid detecting the track-top). 3 Set the range switch to the short range ( ) setting. CAUTION Do not touch the mesh cover of the Motion Sensor. Deformation of the cover could cause the sensor to fail. (1-4) Install the Force Sensor. 1 Install the End Stop at the right end of the track. 2 Using FS thumbscrew, attach the Force sensor. 3 Screw the spring bumper into the Force Sensor. CAUTION Do not tighten the bumper spring too hard. It could cause the Force sensor to fail. Treat it with care. (1-5) Connect the sensors to the interface. (1-6) Adjust the inclination of the track. Use track feet to raise the Motion Sensor end of the track. Do not raise the Motion Sensor end of the track too high. The faster the cart moves, the more likely that it may move to one side or the other during the collision. A smooth but slow collision is better than a fast, jerky one.

(2) Set up Capstone software. (2-1) Add [Motion Sensor] and [Force Sensor]. The interface automatically recognizes the Motion Sensor and the Force Sensor. (2-2) Configure the Force Sensor. Click the Force Sensor icon in the [Hardware Setup] panel and then click the properties button ( ) in the lower right corner. In the [Properties] window, Uncheck [Change Sign]. The sign of collected data of the Force sensor is initially positive for the pushing force. (2-3) Adjust the sample rate of measurements. Select [1.00 khz] for [High Resolution Force Sensor], and [20.00 Hz] for [Motion Sensor] in the [Controls] palette. (2-4) Add graph displays. 1 Click and drag the [Graph] icon from the [Displays] palette into the workbook page. 2 Click [Add new plot area ] of the tool bar to add a xxaxis synchronized graph. 3 Select [Time(s)] for the xx-axis, and [Force(N)] and [Velocity(m/s)] for each yy-axis. (3) Measure the mass of the Cart. mm = (kg) (4) Mount the Cart on the Track. Place the cart in front of the Motion Sensor at least 15cm away. (The sensor cannot measure the distance closer than 15cm.) (5) Zero the Force Sensor. Press [ZERO] button on the sensor. You should zero the sensor prior to each data run.

(6) Begin recording data. Click the [Record] button at the left end of the [Controls] palette to begin collecting data. The Motion Sensor starts clicking. If a target is in range, the target indicator flashes with each click. (7) Release the cart. NOTE The Motion Sensor uses an electrostatic transducer as both a speaker and a microphone. For each sample, the transducer transmits a burst of 16 ultrasonic pluses. The ultrasonic pulses reflect off an object and return to the sensor. The sensor measures the time between the trigger rising edge and the echo rising edge. It uses this time and the speed of sound to calculate the distance to the object. You should remove objects that may interfere with the measurement. These include objects, and also your hand, between the sensor and target object, either directly in front of the sensor or to the sides. (8) Stop data collection. Wait until the cart stops after collision. When the cart stops, click [Stop]. (9) Analyze the data. 1 Scaling and Panning graphs. 2 Area under a curve Click [Select range(s) ] icon and then drag the data range of interest. Click [Display area ] icon to measure the area under the curve.

3 Data point Use [Show coordinates ] icon to read off the data point. 4 Fit Function Because the Force Sensor (1kHz) and the Motion Sensor (20Hz) sample at the different rate, as you set in step (2-3), the resultant time intervals of measurements are different, as shown below. The measured velocities are average velocities during each time interval so they could be quite different from the real instantaneous velocities in the region of sudden change. To find the velocity just before the collision and the velocity just after the collision, we need to find the fit function of the vv-tt graph. 1 Using FF-tt graph, find the time just before the collision and the time just after the collision. 2 Find the linear fits for the before-collision region and the after-collision region of vv-tt graph. 3 Calculate the instantaneous velocities by substituting 1 into 2. Follow the steps below to find the linear fit for vv-tt graph. Click [Select range(s) ] icon and then drag the data range of interest. Click [Select curve fits ] and select [Linear: mt+b] to find linear fit for selected data points.

(10) Verify impulse-momentum theorem. Find the experimental values of following equations by reading off the graphs, and verify impulse-momentum theorem. pp = mmvv (2) tt 2 JJ = FF dddd (9) tt 1 JJ = pp 2 pp 1 (7) (11) Repeat measurement. 1 Vary the collision speed by adjusting the inclination of the track or by adjusting the starting position of the cart. 2 Change the bumper spring with different spring constant. FFFFFF pp 2 pp 1 1 2 3 Experiment 2. Impulse NOTE In this experiment, the Photogate works as an optical switch so that you can automatically start or stop data collection. The automatic measurement method is very helpful in easy analysis. However, if it looks complicated to use automatic measurement method, then you don t have to use the Photogate. In this case, skip steps (1-2)~(1-4) and (2-2)~(2-5). (1) Set up equipment. Follow the setup of experiment 1, and then, (1-1) Remove the Motion Sensor. (1-2) Install the Photogate. Attach the photogate on the bracket using a thumbscrew.

(1-3) Connect the sensors to the interface. (1-4) Adjust the position of the Photogate. Place the Photogate where the cart blocks the Photogate beam just before the cart collides the Force Sensor, as shown in the figure below. (2) Set up Capstone. (2-1) Add the Force Sensor. The interface automatically recognizes the Force Sensor. (2-2) Add the Photogate. Click the input port which you plugged the Photogate into and select [Photogate] from the list.

(2-3) Create and configure a timer. Create a timer and configure automatic recording conditions. 1 Click [Timer Setup] in the [Tools] palette, and then select [Pre-Configured Timer]. 2 Check [Photogate, Ch1]. 3 Select [One Photogate (Single Flag)]. 4 Check [State], which outputs the value of state of the photogate. The photogate generates 1 while it is blocked, and 0 while open. 5 Skip steps 5 to 6 and finish the timer setup. (2-4) Configure automatic recording conditions. 1 Start Condition The cart approaches and blocks the IR of the photogate. The state value of the Photogate changes from 0 to 1. Start data collection 2 Stop Condition The cart comes out of the Photogate after colliding with the Force Sensor. (IR unblocked) The state value of the Photogate changes from 1 to 0. Stop data collection. Click [Recording Conditions] in the [Controls] palette. Select [Measurement Based] for [Condition Type] of [Start Condition]. Set the parameters of [Start Condition] as below. [Condition Type] : Measurement Based [Data Source] : State() [Condition] : Is Above [Value] : 0.5

Set the parameters of [Stop Condition] as below. [Condition Type] : Measurement Based [Data Source] : State() [Condition] : Is Below [Value] : 0.5 (2-5) Check the automatic recording configuration. You can see the [Record] button at the beginning. If you click [Record], Capstone waits until the start condition is achieved. ([Record] toggles to [Stop] and recording status display indicates [Waiting].) Even if the timer is ticking, no data is recorded. If you block the photogate (start condition) using your finger, data recording starts automatically. The recording status display indicates [Recording]. If you open the photogate (stop condition), data recording stops automatically. The status display indicates [Ready]. (2-6) Adjust the sample rate of measurements. Select [1.00 khz] for [High Resolution Force Sensor]. (2-7) Create a graph display. Click and drag the [Graph] icon from the [Displays] palette into the workbook page. Select [Time(s)] for the xx-axis and [Force(N)] for the yy-axis. (3) Mount the cart on the track. Place the cart on the track at the starting position. Use the Universal Bracket so you can release the cart at the same position for all trials. (4) Zero the Force Sensor. Press the [Zero] button on the sensor (5) Begin recording data. (6) Release the cart. Re-adjust the angle of the track, if required.

(7) Check the graph. NOTE If the collision speed is too high, the bumper spring becomes over-compressed, i.e. impact is directly transferred to the Force Sensor, and as a result, the graph will show a sharp peak at the center as below. In this case, you should decrease the collision speed so the graph shows a smooth peak. (8) Repeat experiment using the other spring bumper. Change the spring bumper with a different spring constant and repeat steps (3)~(7). Make sure you do not change the inclination of the track and the starting position of the cart so the velocities just before collision are always same. (9) Analyze the data. Compare the graphs of two cases. 1 Displaying multiple runs Click to depress [Allow simultaneous viewing ] icon. Click the pull-down arrow [ ] and select runs to display. NOTE Recorded data run has a default name Run#%1, where %1 is an automatically generated run number. You can change the name of each data run if required. 1 Click [Data Summary] in the [Tools] palette 2 Select [Show Sensor Data] tap. 3 Right-click on the run name of interest. 4 Select [Rename] from the pop-up list. 2 Area of the graph 3 Data point Refer to the step (9) of experiment 1.

(10) Repeat measurement. Vary the collision speed by adjusting the inclination of the track or the starting position of the cart. Repeat steps (3)~(9). (11) Analyze your result. You do not measure the speed of the cart in this experiment. However, it is reasonable that the change in momentum is same for each run if you release the cart in the same position. 1 st 2 nd 3 rd JJ spring1 JJ spring2 End of LAB Checklist Please put your equipment in order as shown below. Delete your data files from your lab computer. Turn off the Computer and the Interface. Keep the Track Feet attached to the track. Assemble the Universal Bracket and Spring Bumper as shown below. Tighten all thumbscrews in position. Do not try to completely unscrew the thumbscrew and nut assembly of Track Feet, End Stops, and Brackets.