Electrical Safety Tester

Similar documents
Electrical Safety Tester

Electrical Safety Tester

Multiplex Scanner Box

Operating manual PREMIER Serie - English SEFELEC REFERENCE PENT4252

Ground Bond Tester GCT-9040 USER MANUAL GW INSTEK PART NO. 82CT-90400E01. Test Equipment Depot Washington Street Melrose, MA 02176

Arbitrary Function Generator

Arbitrary Function Generator

Multi-output DC Power Supply

Arbitrary Function Generator

INSTRUCTION MANUAL. Multiplex Scanner Box for STW-9000 Series B

Tablet Oscilloscope Safety Information

COM-POWER OPERATION MANUAL ACS W

Synthesized Function Generator

EC Declaration of Conformity

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

RF & Communication Trainer

Dual Display Digital Multimeter

2015 RIGOL TECHNOLOGIES, INC.

Signal and Tracking Generator

RF & Communication Trainer

Digital Multimeter. GDM-8200A Series USER MANUAL GW INSTEK PART NO. 82DM-8255A3A1 ISO-9001 CERTIFIED MANUFACTURER

50000 Counts Dual Display Digital Multimeter

DM-45 Digital Multimeter

30MHz Dual Trace Oscilloscope

TOS8830 DANGER OPERATION MANUAL

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Dual Measurement Multimeter

A Solid Foundation for Reliable, Safe and Practical Safety Compliance Testing.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

User Manual 4 wire Earth Resistance Tester Model GRT300

400Amp True RMS AC Clamp Meter + NCV

Digital Clamp Meter Model: &

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Part No. Z , IB Aug OPERATION MANUAL EARTH CONTINUITY TESTER TOS6200 TOS6210

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

374/375/376 Clamp Meter. Users Manual

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Dual Measurement Multimeter

Instruction Manual IPS X303 Series DC Power Supply

AD U DAB/FM Tuner. Item ref: UK User Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Digital Multimeter, Pen Type

ELECTRICAL SAFETY TESTERS.

TOS9200 SERIES Hipot Tester with Insulation Resistance Test

Datasheet Electrical Safety Tester

DS1000E, DS1000D Series Digital Oscilloscope

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

RIGOL. Quick Guide. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Jul RIGOL Technologies, Inc.

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

DS1000B Series Digital Oscilloscope

OPERATION MANUAL TOS8030 DANGER

Electrical Multimeter

netzerotools.com 374/375/376 Users Manual Clamp Meter

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER'S MANUAL DMR-4350

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

374/375/376 Clamp Meter

USER'S MANUAL DMR-6700

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

Dawson DDM190. Digital Multimeter User s Manual

TOS5101 TOS5051 TOS5050

SSA3000X Series Spectrum Analyzer. Quick Guide

Model: &

KMD-S04 Multímetro de bolsillo

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Precision LCR Meter. LCR-8000G Series USER MANUAL GW INSTEK PART NO. 82CR-81010MI1 ISO-9001 CERTIFIED MANUFACTURER

A WORLD OF LISTENING WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

Precision LCR Meter LCR-8101 USER MANUAL GW INSTEK PART NO. 82DS-22040M

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Mixer Amplifier series

RIGOL Service Guide. DS4000 Series Digital Oscilloscope. Mar RIGOL Technologies, Inc.

TOS9200 TOS9201 DANGER

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

True RMS Digital Multimeter Model:

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

200Amp AC Clamp Meter + NCV Model MA250

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

312, 316, 318. Clamp Meter. Users Manual

SA 125 mixer amplifier. user manual

ProfiScale MULTI Multimeter

Precision LCR Meter. LCR-8000G Series USER MANUAL GW INSTEK PART NO. 82CR-81010MB1 ISO-9001 CERTIFIED MANUFACTURER

MS2030 CAT III 600 V A V AUTO RS232

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

R PROFLAME Instruction Book Collection

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Transcription:

Electrical Safety Tester GPT-9600 Series QUICK START GUIDE GW INSTEK PART NO. 82PT-96030MA1 ISO-9001 CERTIFIED MANUFACTURER

This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the right to change specification, equipment, and maintenance procedures at any time without notice. Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.

Table of Contents Table of Contents SAFETY INSTRUCTIONS... 4 Safety Symbols... 4 Safety Guidelines... 5 Power cord for the United Kingdom... 7 INTRODUCTION... 8 GPT-9600 Series Overview... 8 Main Features... 9 Accessories... 9 Panel Overview... 11 Front Panel... 11 OPERATION... 12 Status Modes... 12 Operation Flow Chart... 12 READY Status... 13 EDIT Status... 14 TEST Status... 16 PASS/FAIL Result... 17 STOP Status... 18 Common Utility Settings... 19 TEST Utility Settings... 20 3

GPT-9600 Series Quick Start Guide SAFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow during operation and storage. Read the following before any operation to ensure your safety and to keep the instrument in the best possible condition. Safety Symbols These safety symbols may appear in this manual or on the instrument. WARNING CAUTION Warning: Identifies conditions or practices that could result in injury or loss of life. Caution: Identifies conditions or practices that could result in damage to the instrument or to other properties. DANGER High Voltage Attention Refer to the Manual Protective Conductor Terminal Frame or Chassis Terminal Earth (ground) Terminal 4

SAFETY INSTRUCTIONS Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Safety Guidelines General Guideline CAUTION Power Supply WARNING Do not place any heavy object on the instrument. Avoid severe impact or rough handling that leads to damaging the instrument. Do not discharge static electricity to the instrument. Use only mating connectors, not bare wires, for the terminals. Do not block the cooling fan opening. Do not disassemble the instrument unless you are qualified. (Measurement categories) EN 61010-1:2010 specifies the measurement categories and their requirements as follows. The GPT-9600 Series does not fall under category II, III or IV. Measurement category IV is for measurement performed at the source of low-voltage installation. Measurement category III is for measurement performed in the building installation. Measurement category II is for measurement performed on the circuits directly connected to the low voltage installation. AC Input voltage range: 100-120/220-240VAC ±10% Frequency: 50Hz/60Hz To avoid electrical shock connect the protective grounding conductor of the AC power cord to an earth ground. Connect the Earth terminal on rear panel to an earth ground. 5

GPT-9600 Series Quick Start Guide Cleaning the GPT-9600 Operation Environment Storage environment Disconnect the power cord before cleaning. Use a soft cloth dampened in a solution of mild detergent and water. Do not spray any liquid. Do not use chemicals containing harsh material such as benzene, toluene, xylene, and acetone. Location: Indoor, no direct sunlight, dust free, almost non-conductive pollution (Note below) Relative Humidity: 70% (no condensation) Altitude: < 2000m Temperature: 0 C~40 C (Pollution Degree) EN 61010-1:2010 specifies the pollution degrees and their requirements as follows. The GPT-9600 Series falls under degree 2. Pollution refers to addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity. Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution has no influence. Pollution degree 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. Pollution degree 3: Conductive pollution occurs, or dry, nonconductive pollution occurs which becomes conductive due to condensation which is expected. In such conditions, equipment is normally protected against exposure to direct sunlight, precipitation, and full wind pressure, but neither temperature nor humidity is controlled. Location: Indoor Temperature: -10 C to 70 C Relative Humidity: 85% (no condensation) 6

SAFETY INSTRUCTIONS Power cord for the United Kingdom When using the safety tester in the United Kingdom, make sure the power cord meets the following safety instructions. NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code: Green/ Yellow: Earth Blue: Neutral Brown: Live (Phase) As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug/appliance, proceed as follows: The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with either the letter E, the earth symbol or coloured Green/Green & Yellow. The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black. The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, a cable of 0.75mm 2 should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any exposed wiring from a cable, plug or connection that is engaged in a live socket is extremely hazardous. If a cable or plug is deemed hazardous, turn off the mains power and remove the cable, any fuses and fuse assemblies. All hazardous wiring must be immediately destroyed and replaced in accordance to the above standard. 7

GPT-9600 Series Quick Start Guide INTRODUCTION This Quick Start Guide is intended as a fast introduction to operating the GPT-9600 Series Safety Testers. This Quick Start Guide assumes that the user is familiar with safety testers. For comprehensive instructions on the GPT-9600 Series, please see the User Manual, located on the accompanying CD. GPT-9600 Series Overview The GPT-9600 Series Safety Testers are AC/DC withstanding voltage and insulation resistance safety testers. The GPT-9603 is an AC/DC withstanding and insulation resistance safety tester. The GPT-9602 is an AC/DC withstanding safety tester. The GPT-9612 is an AC withstanding and insulation resistance safety tester, while the GPT-9601 is purely an ACW tester. Note: Throughout this quick start guide, the terms ACW, DCW and IR refer to AC Withstanding, DC Withstanding and Insulation Resistance, respectively. GPT-9600 refers to any of the GPT-96XX models. 8

INTRODUCTION Main Features Performance Features Interface ACW: 5kVAC DCW: 6kVDC IR: 50V, 100V, 250V, 500V, 1000V Timer control Safety discharge Over temperature, voltage and current protection Pass, Fail, Test, High Voltage and Ready indicators PWM output (increased reliability) Interlock (configurable) Remote control start/stop interface terminal Signal I/O port for pass/fail/test monitoring and start/stop control/interlock Accessories Standard Accessories Part number Description N/A N/A N/A GHT-114 x1 Region dependent N/A N/A N/A GPT-96XX unit. User manual CD Quick start guide Test lead Power cord Remote terminal male plug Interlock key CTC (Calibration Traceable Certificate) 9

GPT-9600 Series Quick Start Guide Optional Accessories Part number Description GHT-205 High Voltage Test Probe GHT-113 High Voltage Test Pistol GRA-417 Rack mount kit 10

CALIBRATION USE ONLY SIGNAL I / O START STOP AC / DC Withstanding Voltage / Insulation Resistance TO AVOID ELECTRIC SHOCK THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND. FOR CONTINUED FIRE PROTECTION. REPLACE ONLY WITH SPECIFIED TYPE AND RATED FUSE. NO OPERATOR SERVICEABLE COMPONENTS INSIDE. DO NOT REMOVE COVERS. REFER SERVICING TO QUALIFIED PERSONNEL. SER. NO. LB Tester REMOTE PASS FAIL READY TEST ESC FIELD EDIT SAVE UTILITY HIGH VOLTAGE ENSURE THE POWER IS REMOVED FROM THE INSTRUMENT BEFORE REPLACING THE FUSE LINE VOLTAGE ( 50 / 60Hz ) 100 120V 220 240V FUSE T 4A 250V AC POWER MAX. 400VA RETURN 5.0 kvac MAX. 6.0 kvdc MAX. GND INTRODUCTION Panel Overview Front Panel Display PASS/FAIL indicators Function keys Navigation keys READY indicator GPT-9603 TEST indicator CAUTION HIGH VOLTAGE indicator POWER button POWER HIGH VOLTAGE output terminal RETURN terminal Rear Panel START button REMOTE terminal Scroll wheel STOP button Configuration keys Calibration port Fan GND WARNING SIGNAL I/O Line voltage Fuse holder 11

GPT-9600 Series Quick Start Guide OPERATION Status Modes This section describes the overall structure of the operating modes for the GPT-9600 Series safety testers. The testers have 6 status modes: (EDIT, READY, TEST, STOP, FAIL, PASS). The flow chart below describes how to navigate from mode to mode. Operation Flow Chart F A I L Status (buzzer on) PASS/FAIL Judgement P A S S status STOP T E S T status START STOP S T O P status F A I L Status (buzzer off) START STOP STOP SAVE STOP R E A D Y status Common Utility Settings 1 UTILITY SAVE EDIT 1. ESC to cancel and return to the previous screen. E D I T status 1 UTILTY SAVE TEST UTILITY Settings 1 12

OPERATION READY Status Description When the tester is in READY status, it is ready to begin testing. ing the START button will begin testing and put the tester into TEST status. ing the EDIT key will put the tester into the EDIT status. ing the UTILIY key will enter the Common Utility settings. The READY status can also be used to set the testing mode. The testing mode can be set to run a single test at a time or to run two different tests sequentially. READY Status H = 2 2. 0 m A A CW D CW L = 0. 0 0 m A T = 1 7 4 S 1 00 E A k V m A I R R D Y M O D E T I M E Test mode Set the Testing Mode the MODE soft-key to toggle between MODE (single test) and each of the Auto Modes. (AC-IR, IR-AC, DC-IR, IR-DC) The Auto Mode function sets two different test functions and the order that will they run. I.e., AC-IR means an ACW test is performed followed by an IR test. When the unit is in TEST status, the Test Mode determines whether a single test is run or if two tests are run sequentially. M O D E 13

GPT-9600 Series Quick Start Guide Go to EDIT Status the EDIT key. EDIT Set the Test Voltage When in the READY mode, turn the scroll wheel knob to set the test voltage. Start Testing the START button to begin testing. The tester will go into TEST status. START WARNING WARNING If Double Action is active, the START button must be pressed within 500ms after the STOP button was pressed to be able to start testing. If INTERLOCK is set to ON and the interlock key is not connected to the SIGNAL I/O port, INTERLOCK OPEN will be displayed on the screen, preventing the test from starting. See page 19 for the Common Utility settings. EDIT Status Description EDIT status is used to edit the test parameters (excluding the test voltage). ing the SAVE key will save any changes and return to the READY status. ing the ESC key will cancel any changes and return to the READY status. ing the UTILITY key will enter the TEST Utility settings. 14

OPERATION High limit Low limit EDIT Status Time setting H = 2 2. 0 m A A CW D CW L = 0. 0 0 m A T = 1 7 4 S 0 00 E D I k V m A I R T M O D E T I M E ACW, DCW and IR test indicators Ground mode Time soft-key Choose Test Function Use the ACW, DCW or IR soft-keys to choose a test function. A CW D CW I R Choose High/Low limits Use the FIELD key to bring the cursor to the H or L setting. Use the scroll wheel to edit the setting. FIELD Test Time Use the FIELD key to select the T setting. Use the scroll wheel to edit the time. the TIME soft-key to toggle the test time ON/OFF. Note that the test time cannot be edited with the scroll wheel when the test time is set to OFF. FIELD T I M E Save the test settings and return to READY Status the SAVE key. The current test is saved in memory. The tester reverts back to READY status. SAVE 15

GPT-9600 Series Quick Start Guide Exit EDIT status and Return to READY Status the ESC key. The tester does not save and returns back to READY status. ESC TEST Status Description TEST status is active when a test is running. ing STOP will cancel the test and put the tester into the STOP status. Waiting for the test to complete will result in a PASS or FAIL judgment. TEST Status H = 2 2. 0 m A L = 0. 0 0 m A T = 0 0 8 S 0 14 0 00 T E S k V m A A CW D CW I R M O D E T I M E T Set the Test Voltage For ACW and DCW mode, the scroll wheel can be used to set the test voltage when the test is running. Clockwise increases the voltage. Anti-clockwise reduces the voltage. Get Test Results Wait for the test to finish. Abort Test the STOP button The tester will go into STOP status. STOP NOTE When in STOP status all panel keys are locked except for the STOP key. 16

OPERATION PASS/FAIL Result Results Results When the tester is allowed to run to completion, the test result is shown as a PASS or FAIL. When the PASS or FAIL results are shown on the screen, the PASS or FAIL indicators will also light up. FAIL Status H = 2 2. 0 m A L = 0. 0 0 m A T = 0 6 0 S 1 00 23 0 F A I k V m A A CW D CW I R M O D E T I M E L Return to READY Status the STOP button once for a PASS judgment, or twice for a FAIL judgment. STOP Restart the Test After a PASS judgment, the test can be re-run by pressing the START button. START View PASS Auto Mode Test Results For a PASS result, turn the scroll wheel left or right to view test results. the STOP button to return to READY status. 17

GPT-9600 Series Quick Start Guide View FAIL Auto Mode Test Results For a Fail Judgment, press the STOP button once to turn off the buzzer tone. Then turn the scroll wheel left or right to view test results. ing the STOP button again will return the tester to READY status. STOP STOP Status Description STOP status is shown when a test does not finish running and has been stopped by the operator. When in STOP status, pressing STOP will return the tester to READY status. STOP Status H = 2 2. 0 m A L = 0. 0 0 m A T = 0 0 8 S 0 14 0 00 S T O k V m A A CW D CW I R M O D E T I M E P Return to READY Status the STOP button STOP 18

OPERATION Common Utility Settings Description The Common Utility menu is accessed by pressing the UTILITY key when the tester is in READY status. This utility controls the LCD and control settings. These settings are system wide. The Common Utility settings include: LCD: LCD Contrast, LCD Brightness CTRL: Start Ctrl (FRONT PANEL, SIGNAL I/O, REMOTE CONNECT), Double Action, Key Lock, Interlock C O MM O N U T I L I L C D C o n t r a s t : L C D B r i g h t n e s T Y 7 s : B R I G H T T I M E R = 0 0 T I M E R = 0 0 R = 0 0 L C D C T R L T I M E R = 0 0 Utility selection Select a Utility Setting. Choose a utility by pressing the LCD or CTRL softkey under the LCD bezel. The chosen utility will be displayed. Use the FIELD key to highlight a setting. Use the scroll wheel to choose or edit a parameter for the setting. L C D FIELD C T R L NOTE The INTERLOCK function is set to OFF by default in the Common Utility>CTRL menu. To increase safety, set INTERLOCK to ON and use the accompanying Interlock key to enable testing. Save the Common Utility Setting To save any changes, press the SAVE key. SAVE 19

GPT-9600 Series Quick Start Guide The tester will return to READY status. Cancel and Exit the Common Utility Menu To exit and cancel any changes, press the ESC key. ESC The tester will return to READY status. TEST Utility Settings Description The TEST Utility menu is accessed by pressing the UTILITY key when the tester is in EDIT status. The TEST Utility settings are configured for each test function (DCW or ACW) separately. The settings include: ARC MODE (ACW, DCW), and FREQUENCY (ACW). T E S T U T I L I T Y A R C M O D E : O F F F R E Q U E N C Y : 6 0 H Z T I M E R = 0 0 T I M E R = 0 0 T I M E R = 0 0 T I M E R = 0 0 Select a Setting. Use the FIELD key to highlight a test setting. Use the scroll wheel to choose a parameter for the setting. FIELD Save the TEST Utility Settings To save any changes, press the SAVE key. SAVE The tester will return to EDIT status. 20

OPERATION Cancel and Exit the TEST Utility Menu To exit and cancel any changes, press the ESC key. ESC The tester will return to EDIT status. 21