E MC Ane c hoi c Chambers.)+6! Features 6 MHz - 8 GHz Frequency Range Full Compliance Testing for Radiated Emissions: - ANSI C6. Parts 5 & 8 - EN 57 - CISPR / EN55 - CISPR 6/ EN556 - CISPR / EN55 - VCCI V/97. (997) - SAE J55, RE & RI --Requires chamber modifications to accommodate full vehicle Full Compliance Testing for Radiated Immunity: - IEC 6/EN6 - ENV 5 - SAE J, RE & RI Eligible for FCC Class B Facility Filing Available as a Turnkey Package: Chamber, Tower, Turntable, Antennas, Instrumentation, and Software ETS-Lindgren Chambers offer semi-anechoic radiated emissions (RE) and fully anechoic radiated immunity (RI) compliance test capability for most international EMC compliance regulations. The chamber s small overall size results from the use of hybrid absorber and ferrite tile, which require less volumetric space than traditional absorbers. chambers will fit in many existing structures, yet are large enough to perform meter antenna scans above the ground plane. When installed with ETS-Lindgren s LoPro or EuroPro turntables, pit excavations for motor assemblies are eliminated. ETS-Lindgren chambers are the perfect choice when facility space is limited, but m range testing is required. USA +.5.5.6 Phone +.5.5.65 Fax info@ets-lindgren.com Europe (Finland) +58..88. Phone +58..865. Fax info@ets-lindgren.eu.com ETS-Lindgren EMC Semi-Anechoic Chamber Performance ETS-Lindgren chambers achieve their broadband performance using a unique arrangement of hybrid and ferrite tile absorber. The design was modeled using the proprietary numerical electromagnetic software responsible for creating chambers that set new standards for anechoic performance. Radiated Emissions Testing ETS-Lindgren s chambers can be used to perform full compliance testing for ANSI C6. (Parts 5 & 8), EN 57, CISPR / EN55, CISPR 6/ EN556, CISPR /EN55, VCCI V/97. (997), and SAE J55 full vehicle testing requirements (chamber modifications to accommodate full vehicle are required). UK +.()8.77 Phone +.()8.775 Fax info@ets-lindgren.co.uk France +..8.65.. Phone +..8.65..69 Fax lrp.france@wanadoo.fr At test distance, ETS-Lindgren guarantees a Normalized Site Attenuation (NSA) deviation better than ±.5 from theoretical NSA within the quiet zone, over the frequency range of MHz to GHz. The quiet zone at the test distance is a cylinder up to. meters in diameter following the volumetric test procedure of ANSI C6.. Anticipating tomorrow s requirements, the FerroSorb hybrid and FT series ferrite tile absorbers used in the also guarantee NSA performance of better than ±.5 deviation from theoretical NSA using the test method defined in ANSI C6. at the extended frequency range of to GHz. Singapore +65.656.778 Phone +65.656.79 Fax Irfesin@singnet.com.sg Japan +8..8.7 Phone: +8..8.868 Fax: info@ets-lindgren.co.jp China +86..875.5986 Phone +86..875.55 Fax infochina@ets-lindgren.net / - k S ETS-Lindgren REV E
Radiated Immunity Testing ETS-Lindgren s chambers can also be used to perform full compliance testing for IEC 6/EN6-, ENV 5 and SAE J component-level requirements. At range lengths, field uniformity of, +/- 6 is achieved in the test aperture over the frequency range of 6 MHz to GHz. The test aperture is a vertical plane.5 m x.5 m at an elevation of.8 m to. m above the ground plane, following the field uniformity test procedure of IEC 6. An optional absorber treatment package is available which permits radiated immunity testing at frequencies up to 8 GHz with, + 6 field uniformity, following the test procedure of IEC 6. Additionally, FerroSorb can safely withstand continuous field intensity of up to V/m and intermittent field intensity of up to 5 V/m. This safely exceeds the field intensity requirements of most commercial RI tests. Turnkey Systems ETS-Lindgren is an integrated manufacturer producing such wellknown brands as Rantec absorber, RayProof Series 8 and Euroshield shielding and RF doors, EMCO antennas, towers, turntables, and test accessories. All of our products are designed to work together for maximum efficiency and performance. In addition to providing performance, our Total Solution, Single Source approach simplifies complex decisions and gives you peace of mind with a single source of responsibility. Baseline Configuration for m Quiet Zone Design and fabricate RF-shielded enclosure, interior nominal shield-toshield dimensions of 8.5 m L x 6. m W x 5.6 m H, (8 x x 8.5 ) includes 5. cm (6 ) raised floor One single-leaf, Series, recessed contact mechanism (RCM), manually operated, RF-shielded door,. m x. m ( x 7 ) clear opening One door maintenance kit Dielectric vapor barrier and masonite underlayment Raised, reflective ground plane, 5. cm (6 ) high Four access hatches in raised floor,.8 cm ( ) x.8 cm ( ) Four waveguide vents,.8 cm ( ) x.8 cm ( ) Five x amp, 6 Hz power-line filters for lights, EUT and TT Power (wiring not included) Two connector panels, 5. cm (6 ) x 6.96 cm (") clear opening Two N type connectors One.8 cm (.5 ) pipe penetration with flange nuts and cap Two fiber optic ST-type feed-through kits One RF-shielded penetration for air line to MiniMast ; compressed air is responsibility of customer One threaded brass ground stud.7 cm (.5 ) diameter x.7 cm (5 ) long Six corner-mounted light fixtures with floodlights ( electrical distribution not included) Shield test per MIL-STD85, one frequency test at GHz FT-5 on non-critical areas of sidewalls and ceiling FT-5 for full coverage of transmit end-wall PS-6, hybrid absorber on specular ( critical ) regions of side-walls and ceiling PS-6, hybrid absorber full coverage of end-wall behind turntable Light reflective covers for PS-6 and ferrite tile absorber on the walls and door 6 pieces each Rantec brand FT-c ferrite tile panels and EHP-8 CL for an area of the floor for immunity testing to 8 GHz Normalized site attenuation performance test per ANSI C6., from MHz to GHz (optional testing to 8 GHz and GHz) Field uniformity calibration per IEC 6, from 6 MHz to GHz (optional testing to 8 GHz) Installation of the enclosure and absorber ETS-Lindgren Model 88. electrically powered m turntable with fiber optic cable and feed-through ETS-Lindgren Model 9 dual device controller ETS-Lindgren Model 75 MiniMast electrically powered air polarization boom tower with m fiber optic cable and feed-through Guaranteed performance and a five-year limited warranty; one-year warranty on doors, filters and moving parts; two-year warranty on ETS-Lindgren equipment +.5.5.6 Phone +58..88. Phone +.()8.77 Phone +..8.65.. Phone +65.656.778 Phone +8..8.7 Phone: +86..875.5986 Phone +.5.5.65 Fax +58..865. Fax +.()8.775 Fax +..8.65..69 Fax +65.656.79 Fax +8..8.868 Fax: +86..875.55 Fax / - k S ETS-Lindgren REV E
Options Shielded control room,.87 m x.5 m x. m (6 ft x ft x 8 ft) Compact-sized shielded control room,.66 m x.5 m x. m ( ft x ft x 8 ft) Shielded amplifier room,. m x. m x. m (8 ft x 8 ft x 8 ft).8 cm ( ) and 5.75 cm (8 ) raised ground planes Ferrite floor panels mounted on rolling carts Low profile door sill for Series door CCTV monitoring system Intercom system Fire detection and suppression system Specifications Other door options available Anti-static vinyl floor tile Extra filtering Company logo screen printed onto white caps Immunity interlock switch Electrical distribution Heating, ventilation, and air conditioning (HVAC) system Seismic structural design calculations and certification Normalized Site Attenuation measurement up to 8 GHz and GHz Field uniformity measurement up to 8 GHz Assistance in preparation of FCC filing paperwork (Class B) Recommended Test Equipment Antennas Immunity Only 9 Biconical BiConiLog B BiConiLog with optional endcaps 8 Log Periodic Emissions Only B Biconical BiCal Precision Calculable Biconical B BiConiLog 8 Log Periodic Immunity and Emissions C Biconical (5 W max.) B BiConiLog with optional endcaps 8 Log Periodic Turntables 8., Heavy Duty,. m diameter* 8., Heavy Duty,. m diameter* 87., EuroPro,. m diameter * Model 8 turntables require 8 raised floor Tripods and Towers Immunity Only -TR Tripod 7-TR Tripod 7-TR/POL Tripod Immunity and Emissions 7- Antenna Tower 7 Antenna Tower 7 Antenna Tower MODEL ABSORBER FREQ APPLICABLE INTERNAL SHIELD OVERALL IEC 6 ANSI C6. # TYPE RANGE STANDARDS WORKING ROOM STRUCTURE FIELD NORMALIZED SITE AREA INNER DIM DIM UNIFORMITY ATTENUATION FT-5 non-critical 6 MHz ANSI C6., U.S. FCC (L) 7.9 m 8.5 m 8.99 m 6 MHz - 8 GHz MHz - GHz areas of side-walls to EN57 parts 5&8 6. ft 8. ft 9.5 ft.5 m x.5 m and ceiling GHz VCCI V/97. (997) (W).9 m 6. m 6.6 m +6 FT-5 full coverage CISPR /EN55 6. ft. ft.7 ft 75% 6 Points of TX end-wall CISPR 6/EN556 (H).89 m 5.6 m 6.9 m (Higher Frequency PS-6 on critical CISPR /EN55 6. ft 8.5 ft. ft Field Uniformity areas of side-walls and ceiling IEC 6/EN6 Includes Includes may be limited PS-6 full coverage on Bell Core GR-89 5. cm (6 ) 5. cm (6 ) by the antenna RX end-wall behind turntable raised floor raised floor gain pattern) Light reflective covers for PS-6 and FT-5 on walls 6 pieces ea. of FT-c and EHP-8PCL on area of the floor for immunity testing In critical area around EUT. +.5.5.6 Phone +58..88. Phone +.()8.77 Phone +..8.65.. Phone +65.656.778 Phone +8..8.7 Phone: +86..875.5986 Phone +.5.5.65 Fax +58..865. Fax +.()8.775 Fax +..8.65..69 Fax +65.656.79 Fax +8..8.868 Fax: +86..875.55 Fax / - k S ETS-Lindgren REV E
Measured NSA Horizontal Performance of ETS-Lindgren s EMC Semi-Anechoic Chamber. Fig.. Primary m Range: Measured NSA Hori. Pol., d=m, Tx=m - - 7 8 55 6 79 86 9 Fig.. Primary m Range: Delta NSA Hori. Pol., d=m, Tx=m 7 8 55 6 79 86 9-5 Fig.. Primary m Range: Measured NSA Hori. Pol., d=m, Tx=m (-8 GHz) 5 5 5-55 -65-5 6 7 8 9 5 6 7 8 Fig.. Primary m Range: Delta NSA Hori. Pol., d=m, Tx=m (-8 GHz) 5 6 7 8 9 5 6 7 8 +.5.5.6 Phone +58..88. Phone +.()8.77 Phone +..8.65.. Phone +65.656.778 Phone +8..8.7 Phone: +86..875.5986 Phone +.5.5.65 Fax +58..865. Fax +.()8.775 Fax +..8.65..69 Fax +65.656.79 Fax +8..8.868 Fax: +86..875.55 Fax / - k S ETS-Lindgren REV E
Measured NSA Vertical Performance of ETS-Lindgren s EMC Semi-Anechoic Chamber. 5 5-5 - -5 5 - Fig. 5. Primary m Range: Measured NSA Vert. Pol., d=m, Tx=m 7 8 55 6 79 86 9 Fig. 6. Primary m Range: Delta NSA Vert. Pol., d=m, Tx=m 7 8 55 6 79 86 9-5 Fig. 7. Primary m Range: Measured NSA Vert. Pol., d=m, Tx=m (-8GHz) 5 5 5-55 - 5 6 7 8 9 5 6 7 8 Fig. 8. Primary m Range: Delta NSA Vert. Pol., d=m, Tx=m (-8GHz) 5 6 7 8 9 5 6 7 8 +.5.5.6 Phone +58..88. Phone +.()8.77 Phone +..8.65.. Phone +65.656.778 Phone +8..8.7 Phone: +86..875.5986 Phone +.5.5.65 Fax +58..865. Fax +.()8.775 Fax +..8.65..69 Fax +65.656.79 Fax +8..8.868 Fax: +86..875.55 Fax / - k S ETS-Lindgren REV E