PSD-S CE-TM SPRING. Connection element with spring-cage terminal blocks for tube mounting. Data sheet. 1 Description

Similar documents
PSD-S AE SM DB/1

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

PHOENIX CONTACT

PHOENIX CONTACT

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

MINI MCR-SL-UI-I-LP-NC

TC ANT MOBILE... Mobile communication antennas and antenna cables. Data sheet _en_00. 1 Description

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MINI-PS AC/24DC/1.3

PHOENIX CONTACT - 09/2009

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

This data sheet is only valid in association with the IL SYS INST UM E user manual.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

VC-MEMV-S1. Extract from the online catalog. Order No.:

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

EC centrifugal fan - RadiCal

VC-MP-K1. Extract from the online catalog. Order No.:

EC centrifugal fan - RadiCal

VARIOCON. Modular Contact Inserts

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

MACX MCR-UI-UI-UP(-SP)(-NC)

Speed and Positioning Sensor GEL 2478

VC-MEMV-K3. Extract from the online catalog. Order No.:

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

PHOENIX CONTACT - 03/2007

KDS10/SO. Extract from the online catalog. Order No.:

Cutting and stripping tools

Extract from the online catalog

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

+ A Phoenix Mecano Company. RK DuoLine 160. Degree of protection IP 40. the new industry benchmark

Outside Temperature Sensors

MINI MCR-SL-UI-f(-SP)

MINI-PS AC/2X15DC/1

SW 16mm. SW 15mm. SW 19mm

PACT RCP-4000A-UIRO-Dxxx

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Power supply CP-E 24/2.5

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

Incandescent Lampholders: Edison Screw and Bayonet Cap

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

EC centrifugal fan - RadiCal

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

SLKK 5. Extract from the online catalog. Order No.:

Power supply CP-E 24/0.75

KDSP 4. Extract from the online catalog. Order No.:

QUINT-PS-24DC/24DC/10

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

TRIO-PS-2G/1AC/24DC/5

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Type: DILM40(RDC24) Article No.:

Detecting Devices. 8/2 Introduction

Loud electronic horn High life duration up to 5,000 hrs TECHNICAL SPECIFICATIONS: PC, PC/ABS-Blend, grey Fixing:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

LED Driver Constant voltage

Power supply CP-E 24/20.0

UTTB 4. Extract from the online catalog. Order No.:

Cable Management Solutions with DLP TM

FPS. FPS Flexible Position Sensor. Function description. Your advantages and benefits

Traffic Lights/ Signal Beacons - 890/895/897/894/ families

HARTING Han GND. People Power Partnership

RoHS. High shaft load capacity. Shock / vibration resistant

UTTB 2,5. Extract from the online catalog. Order No.:

QFM21... Duct sensors. Symaro. for relative humidity and temperature

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

LED Driver Constant voltage

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

EC centrifugal fan - RadiCal

Setting Standards Connectors M 16

FL WLAN 24 AP XDB and RAD XDB

Connect - Contact - Control. Connectors. Short Form Catalogue

Signal conditioner - MACX MCR-UI-UI-NC

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

MKDS 3/ 4. Extract from the online catalog. Order No.:

Pressure transmitters SPTW

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

EC centrifugal fan - RadiCal

LENORD GEL BAUER

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set

Power supply CP-E 24/2.5

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

EC centrifugal fan. backward curved, single inlet

TECTUS. The completely concealed hinge system

TIDALFLUX 2300 F Technical Datasheet

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

WIRELESS ACCESSORIES. Accessories for wireless transmission systems. INTERFACE Data sheet _en_06. 1 Description

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

DP2500 DP0100 DP0250 Differential Pressure Transmitter

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Transcription:

Connection element with spring-cage terminal blocks for tube mounting Data sheet 7958_en_02 PHOENIX CONTACT 2015-05-04 1 Description This connection element is provided as a component of a modular signal tower and facilitates the electrical connection of the signal tower. According to your requirements, a signal tower may comprise any combination of up to five signal elements. You may use up to five optical signal elements or up to four optical and one audible signal element. An audible signal element can be used as top element only. A bayonet locking system establishes the mechanical and electrical connection between the elements. Mounting elements for base or tube mounting can be used to mount the signal tower. Features Connection element for the mounting on a tube (see accessories) Degree of protection: IP65, when mounted Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products.

2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 3 5 Mounting the connection element... 4 6 Connecting the cables... 5 7 Example of a signal tower... 5 8 Assembly notes for a signal tower... 5 7958_en_02 PHOENIX CONTACT 2

3 Ordering data Description Type Order No. Pcs./Pkt. Connection element with spring-cage terminal blocks for tube mounting PSD-S CE-TM SPRING 2700092 1 Accessories Type Order No. Pcs./Pkt. Adapter for single-hole mounting PSD-S ME A-SH M18 2700150 1 Foot with integrated tube, 110 mm long, black PSD-S ME BT 110 2700156 1 Tube, 250 mm long, Ø 25 mm PSD-S ME T-M 250 2700157 1 Tube, 400 mm long, Ø 25 mm PSD-S ME T-M 400 2700158 1 Tube, 1000 mm long, Ø 25 mm PSD-S ME T-M 1000 2700154 1 Foot for tube Ø 25 mm, aluminium, black PSD-S ME B-M 2700164 1 Foot for tube Ø 25 mm, plastic, black PSD-S ME B-P 2700163 1 Tube, 45 mm long, Ø 25 mm, for direct tube mounting on the foldaway base PSD-S ME T-P 45 2700152 1 Foldaway base, pitch 7.5, black PSD-S ME FB 2700151 1 Outlet box with lateral cable entry for floor and base mounting PSD-S ME OB 2700153 1 Outlet box with magnetic base for base mounting, black PSD-S ME OB/MB 2700155 1 Angle for base mounting, concealed cable routing, black PSD-S ME BR-BM/HCR 2700149 1 Angle for base mounting, black PSD-S ME BR-BM 2700143 1 4 Technical data Dimensions (in mm) Ø70 26,5 16 Ø69 Ø25 Diameter Height 69 mm 2 7958_en_02 PHOENIX CONTACT 3

General data Material PA-GF Color black Weight 77 g Ambient temperature (operation) -30 C... 50 C Degree of protection IP65, when installed Mounting position any Mounting type Tube mounting Connection Rubber seal pre-installed for each element Number of mountable signal elements max. 5 Scope of delivery End cover and seal Connection data (without ferrule) Conductor cross section, stranded 0.5 mm²... 1.5 mm² Conductor cross section, stranded [AWG] 20-15 Connection data (With ferrule) Conductor cross section, stranded 0.25 mm²... 1.5 mm² Conductor cross section, stranded [AWG] 23-15 Connection data (solid) Conductor cross section, solid 0.5 mm²... 1.5 mm² Conductor cross section, solid [AWG] 20-15 Approvals / conformities Conformance with EMC directive 2004/108/EC and for low-voltage directive 2006/95/EC For the latest approvals, please visit phoenixcontact.net/products. 5 Mounting the connection element Mount the connection element on a tube. The possible options are indicated in the ordering data under accessories. For the mounting the connection element, proceed as described in the package slip. For the connection of cables, proceed as described in the package slip. Please refer to the package list for connection options. It is enclosed with the connection element and can be downloaded from the internet at phoenixcontact.net/products. 7958_en_02 PHOENIX CONTACT 4

6 Connecting the cables 7 Example of a signal tower NOTE: When working on the connection element, disconnect the power to the signal tower! 1 4 3 5 2 2 0 1 3 4 Figure 1 Connections in the connection element Connection Meaning 0 Reference potential (GND, N) 1 Control of the signal element 1 2 Control of the signal element 2 3 Control of the signal element 3 4 Control of the signal element 4 5 Control of the signal element 5 When using the audible elements "siren element, 7 tones..." or "voice output element", several control lines are needed for the audible element, as the case may be. In this case, please note the entries in the corresponding data sheet or in the package slip. Figure 2 Example of a signal tower Key: 1 Audible signal element 2 Optical signal element 3 Connection element 4 Assembly element 8 Assembly notes for a signal tower Only use a maximum of five elements within a signal tower. Use only one audible element in a signal tower and position this element on top. When connecting the bayonet locking, please note the markings (see "Assembly of the individual elements" in the data sheets of the signal elements). 7958_en_02 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 5 phoenixcontact.com