RF converter WTX660-E05060

Similar documents
QAC910. Meteo Sensor. Synco living

Wireless multizone receiver RDE-MZ6

Air damper actuators

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Rotary actuators for ball valves

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Electromotoric actuators for valves

Alpha IP: Room Control Unit Radio Analog

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Electromotoric actuators for stroke valves

Rotary actuators for ball valves

Rotary actuators for ball valves

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Alpha IP: Room Control Unit Radio with Display

Gateway EnOcean/LonWorks

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Thermo Plus Bluetooth-enabled Thermo-Hygro Monitor Model: RAR213HG USER MANUAL

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual

Electrical devices may only be mounted and connected by electrically skilled persons.

Power amplifier for thermic valve actuators

Room Temperature Controllers. for heating and cooling systems

EYL225: nova225, Compact automation station

Electronic device for recording the share of heat output by radiators.

Technical Documentation

Wireless and battery-less room units with EnOcean interface

Communication. Building Technologies HVAC Products. Synco 900. Devices of the Synco 900 range

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

WEATHER IN MOTION Model: BAR200 / BAR200U / BAR200A USER MANUAL

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

TWS 16 PT UHF wireless system. user manual

Radio System Strobe Wizard Plus Freemask

Electromotoric actuators

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Weather Forecast Station with Atomic Time Model: BAR206 / BAR206A

WIRELESS Energy Monitor - Smart Meter

RADIOBAND V3 Programming & Installation Manual

COD GB / 1.0 RBAND/UMS - RBAND/CSM

MSO Supplied with a full SDK including example programs Software compatible with Windows XP, Windows Vista and Windows 7 Free Technical Support

OEM Alpha 2: Base Stations Radio

Compact room automation stations, BACnet MS/TP, AC 24 V

Outdoor wireless double wall switch

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Device Manual Chapter 4.1-R optosonic u 3 radio net

Astra-R Kit Wireless Alarm System Operation Manual

Solar Weather Station Advance Model: BAR808HG / BAR808HGA USER MANUAL

Classic Alarm Clock. User Manual. Model: RRM116/RRM116U. With Radio

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

P700-WLS ioprox Receiver

Final draft ETSI EN V1.2.2 ( )

Wireless LAN network. Wireless USB network

Wireless systems.

Final draft ETSI EN V1.1.1 ( )

Pair of PMR446 Two-Way Personal Radios Model: TP391

Thermo Bluetooth-enabled Thermometer. Model: EMR211 USER MANUAL CONTENTS

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

SonoSelect 10 and SonoSafe 10 Energy Meters

Network Analyzer for Low-, Medium- and High-Voltage Networks

Bedienungsanleitung Handsender HSP 4 BiSecur

WIRELESS BARCODE SCANNER. User Guide.

P700WLS IoProx Receiver

IZAR RADIO. A safe form of radio

VBRC 5. Radio Communicator. Installer Manual

TWS 16 HT UHF wireless system. user manual

basicdim Wireless Casambi Ready

1. Welcome. 2. Description

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

TWS 16 BT UHF wireless system. user manual

Price list 2018 Devices

Electronic Heat Cost Allocator GRADUS User Manual

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Compact room automation stations, BACnet/IP, AC 24 V

PowerFlex 400 AC Drive Guide Specification

Instruction manual ADN-W AM. Antenna Module

Heat meter Q heat 5 US

Lighting Controls and Connectivity basicdim. basicdim Wireless PWM CV 4CH Wireless module for basicdim

Wireless LAN network. Wireless USB network

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

Network Analyzer for Low-, Medium- and High-Voltage Networks

free solo PT UHF wireless system user manual

9/2/2013 Excellent ID. Operational Manual eskan SADL handheld scanner

LIFEPAK Defi brillator CR2. Genuine Accessories

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

Room air quality sensors

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Product Features Benefits The IMC Group Ltd.

Diversity Antenna Distribution Module DADM226. Instruction manual

RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL

T5-600/T Electrical Tester

ELICIUS Electronic Energy Meter Installation and user guide V1.0

SWD R130. Receiver - Doorbell - user manual. Receiver - Zvonek - návod k obsluze. Receiver Zvonček návod na obsluhu

Reaction Chromatic Tuner Instruction Manual

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

TPW288. Transmitter Transmission frequency: MHz Range of up to 50m Battery: 2 x AAA.UM04/LR03 (not included)

Antenna Splitter ASA 1. Instruction manual

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

Active Antenna Combiner ACA 1. Instruction manual

User manual BETSO TCX. 16 channel wireless TC transceiver. 1 Copyright BETSO ELECTRONICS Ltd.

Transcription:

RF converter WTX660-E05060 The WTX660.. RF converter receives and processes data from heat cost allocators, heat and water meters within a M-bus radio system. Storage for up to 500 metering devices Repeater on the mesh system for up to 2,000 additional wireless devices Coverage of distances up to 500 meters outdoors and 40 meters in buildings Supports devices using AES128 encryption RF converter with mains power AC 230 V Optimum location function LED to indicate signal strength 2017-05-31 Building Technologies

Use The RF converter WTX660-E05060 is a component of the M-bus radio network. The RF converter receives the radio telegrams from up to 500 consumer metering devices and then sends the data to the web server. The web server simultaneously serves as a repeater for other wireless devices. Functions Communications Up to 23 RF converters can communicate with one another on a mesh network. Up to 2,500 wireless devices can be managed and read out on each network. Communications between the RF converters and wireless devices takes place over the wireless M-bus protocol. The RF converter receives the data from one or more wireless devices within a radio system as per EN13757-4. It saves the consumption data from the devices in its environment and forwards this data simultaneously with data from other RF converters to the web server (repeater functionality for the other RF converters). A minimum of one M-bus web server and one RF converter is required to read out wireless devices. Optimum location You can power the RF converter over the USB connection using an external battery to help find the optimum location. The RF converter remains mobile during the scan and can be moved to the location with the best signal reception. The blue LED flashes during the scan and indicates the status. The blue LED stops flashing once a connection is found. The four green LEDs indicate the signal strength. All four LEDs are on for a strong signal. Configuration The ACT531 readout software configures the Mesh-ID and Channel-ID. A USB cable with a mini USB-B connection on the RF converter and the PC's USB interface is used to connect the RF converter and PC. Design The RF converter essentially consists of three housing components: The base for wall mounting, the removable cover and the cover for the cable compartment. 1 2 3 1 Base for wall mounting 2 Removable cover 3 Cover for the cable compartment 2

Removable cover version 1 2 1 Green LEDs indicate the signal strength (active only in scan mode) 2 Blue LED for status indication Cover version 1 2 3 4 5 6 7 1 Mains power connection (AC 100..240 V) 3 S2 - Local settings 5 USB connection 7 LED wireless M-bus network 2 S1 - Local settings 4 Reset button 6 LED mesh network Type summary Order information Description Order number Type RF converter S55563-F149 WTX660-E05060 Delivery Mounting instructions are included with the RF converter in various languages as well as mounting materials. 3

Equipment combinations The RF converter WTX660-E05060 is compatible with the following products: Type Order number Designation WTV676-HB6035 S55563-F150 M-bus web server ACT531 JXF:ACT531 Readout software > version 2.0 Product documentation Topic Title Document ID Mounting Instructions RF converter WTX660-E05060 A6V11135905 User s guide M-bus readout software ACT531 A6V10844345 User s guide M-bus web server WTV676-HB6035 M-bus level converter WTV531-GA5060 RF converter WTX660-E05060 A6V11157985 Notes Product inserts Mounting instructions are included with the RF converter in the following languages: German, English, French, Dutch, Italian, Finnish, Spanish, Norwegian, Polish, Czech, Slovakian, Hungarian, Greek, Croatian, Slovenia, Lithuanian, Bulgarian, Turkish. Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download Mounting Specialist electrical engineering knowledge is required for installation. Only an expert is permitted to carry out installation work. Incorrect installation can take safety devices out of operation unbeknown to a layperson. WARNING Electricity on the lines Risk of injury from electric shock Strain relief required on mains connection The RF converter is wall mounted. Additional information on mounting the RF converter is available in document A6V11135905. See Section Product documentation [ 4]. Commissioning The ACT531 readout software is required to upload firmware updates or to configure the network. Additional information on the ACT531 readout software is available in document A6V10844345. See Section Product documentation [ 4]. 4

Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries in designated collection points. Warranty Technical data on specific applications are valid only together with products listed under "Equipment combinations". rejects any and all warranties in the event that third-party products are used. 5

Technical data Power supply Operating voltage AC frequency Maximum power consumption Battery backup of real-time clock Lithium type CR2032 (can be replaced on the plant) AC 100...240 V 50/60 Hz 4.5 W Battery operation: A total of 10 years Unused: 10 years Display Display LED front and in the housing Interfaces Radio AMR (Mesh) Frequency Max. distance between the RF converters M-bus interface Reference standard Frequency Max. number of M-bus wireless devices per RF converter M-bus operating modes USB connection 868 MHz Outdoors: 500 m In buildings: 40 m EN13757-4 (Physical Layer), EN13757-3 (Application Layer) 868 MHz 500 C1, T1, S1 USB2.0 A / Mini-USB B 5 pin Ambient conditions Operating temperature -20..+55 C Storage temperature -25..+85 C Degree of protection IP40 per EN60529 Protection class II per EN 62368-1 Standards, directives and approvals Product standard EN 62368-1 Information Technology Equipment - Safety - Part 1 Electromagnetic compatibility EU conformity (CE) A5W00034204 *) Environmental compatibility A5W00035028 *) For residential, commercial, and industrial environments *) Documents can be downloaded at http://siemens.com/bt/download. External features Housing (material) PC+ABS Housing (color) RAL 9016 Dimensions (L x W x T) 160 x 160 x 35 6

Dimensions 88 88 17,27 5,3 32 176 126,70 64,97 61,73 5 176 37 11,23 86,5 Dimensions in mm 7

Issued by Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Switzerland Ltd, 2017 Technical specifications and availability subject to change without notice. 8 Building Technologies Document ID 2017-05-31 Edition 2017-05-31