Minnesota Rules, Chapter 4732 X-ray Revision

Similar documents
Minnesota Rules, Chapter 4732 X-ray Revision

Minnesota Rules, Chapter 4732 X-ray Revision

Minnesota Rules, Chapter 4732 X-ray Revision

Minnesota Rules, Chapter 4732 X-ray Revision PROPOSED NON-MEDICAL ANALYTICAL X-RAY SYSTEMS, 1.0

Minnesota Rules, Chapter 4732 X-ray Revision PROPOSED NON-MEDICAL CABINET X-RAY SYSTEMS, 1.0

Minnesota Rules, Chapter 4732 X-ray Revision

RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT

TABLE OF CONTENTS. References

(a) This subchapter applies to installations using analytical x-ray equipment and establishes requirements for their use.

PART H RADIATION SAFETY REQUIREMENTS FOR NON-HEALING ARTS RADIATION GENERATING DEVICES (RGD)

APPENDIX K UNF RADIATION GENERATING DEVICE SAFETY PROCEDURES

By: Georgia Institute of Technology

1. Oklahoma Administrative Code (OAC) 252:410, titled Radiation Management

Minnesota Rules, Chapter 4732 X-ray Revision

SUBCHAPTER 14. THERAPEUTIC INSTALLATIONS

Ch. 223 VETERINARY MEDICINE CHAPTER 223. VETERINARY MEDICINE GENERAL PROVISIONS X-RAYS RADIOACTIVE MATERIAL. Authority

LASER RADIATION REQUIREMENTS

Agilent 5DX System. X-ray Safety Test Procedure. for use with Software Release 8.20 and later

05/20/14 1. Philips CM200T. Standby Condition

VACUUM INTERRUPTER APPLICATION NOTES Filename: VIAN X-Rays and Vacuum Interrupters Revision: 0 PAGE 1

ANALYTICAL X-RAY EQUIPMENT RADIATION SAFETY MANUAL

Agilent 5DX Series 2L, 3, and 5000 X-ray Safety Test Report

GE AMX 4+ Portable X-Ray

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF RADIOLOGICAL HEALTH CHAPTER USE OF X-RAY APPARATUS

DENTAL X-RAY OPERATOR'S INSTRUCTIONS. (for USA) Wall Mount Type...WK

White Space Devices (WSDs)

NJDEP Medical Physicist s Radiographic QC Survey Registration Number:

RadView Manual Collimator

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

FEI Titan Image Corrected STEM

Series 48 Water Cooled Laser & UC-2000 Quick Start Guide

Manual Unihan UPWL6024

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Application Note. ipix A Gamma imager to support various applications. Introduction. An easy to carry and deploy instrument

Keene State College Center for Environmental BioGeoChemistry Radiation Protection Program Revised January

INSTALLATION AND OPERATING MANUAL

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

AC-TX Volt/100 Volt Transformer Panel for VR61 and VR62 Loudspeakers and the CLA37 Column Loudspeaker AC-TX128

REQUIREMENTS FOR USE OF NONMEDICAL X;RAY GENERATORS AT SLAC*

Angular Dependence Testing of the Innovative Industrial Solutions (IIS) WAM 500 D Area Monitor

OVA-50 Optical Variable Attenuator User s Manual

Pipe Laser Model No Instruction Manual

Safety Precaution Relating to Intense Radio Frequency Radiation

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

LOCKOUT / TAGOUT PROGRAM

QXR-W XRF SAFETY MANUAL

RK Hydrogen Transmitter Operator s Manual

Rotating Anode X-Ray Tube Housing Assembly. General Data

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT. Emergency Responder Radio Enhancement Coverage System (RES)

800 MHz BIDIRECTIONAL AMPLIFIER Technical manual

Verizon NEBS Compliance and Quality Assurance (NQA) Labeling Requirements for Light Emitting Products

2014 NEC Changes Part 1

Installation and Operation Manual for Signal Booster I

Series 48 Air Cooled Laser & UC-2000 Quick Start Guide

INSTRUCTION MANUAL INF Fax: (503)

LASER ENHANCED REVOLVER GRIP OWNER S MANUAL RED LASER GREEN LASER

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

OPERATOR'S INSTRUCTIONS

CDRH 21 CFR Part 1040 Informative Laser Report

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

Y11-DR Digital Radiography (DR) Image Quality

MaxRay Handheld X-ray Systems Operator Training Exam

Model MHz Arbitrary Waveform / Function Generator

Provläsningsexemplar / Preview

CDR PanElite. j~áåíéå~ååé=fåëíêìåíáçåë==== English

20 Ton HYDRAULIC SHOP PRESS

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

FOUR CATEGORIES OF SAFETY

XRC X-Ray Calibration System

Air Monitoring Directive Chapter 9: Reporting

Landis+Gyr. S4e MFMM Cellnet User Manual. Bulletin Revision A. DOCUMENT HISTORY Bulletin:

X-RAY SAFETY REFRESHER EXAM

Radiological Safety Analysis Document for the CLAS12 Engineering and the first physics run of Run Group A

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

VT1586A Rack Mount Terminal Panel Installation and User s Manual

STEREOTACTIC BREAST BIOPSY EQUIPMENT SURVEYS

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

External brake resistor AX2090-BW5x

Universal Control Module Operating Instructions

Prof. Steven S. Saliterman. Department of Biomedical Engineering, University of Minnesota

1.0 INTRODUCTION WARNINGS 2 DUTY CYCLE 2 STORAGE PHYSICAL DESCRIPTION 3 HIGH VOLTAGE PULSER/TUBEHEAD 3 BASE 3 BATTERY PACK 3

Geotagger N3. User Manual (V1.0) Revised by Geosolve.be (Pol F. Gillard) with personal updates and help. Solmeta Technology Co.

Installation/User Manual

Cat. No. H8861 Model: RCL-S-STAT

User Manual. ProRF Encoder Transmitter & Receiver

OPERATOR'S MANUAL JUNE 2017

T h e P h a n t o m L a b o r a t o r y

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Beaming Optical Length Tester (BOLT)

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

Operating Manual. isolate501

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications.

QL55 Series Luminescence Sensor

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

CR31. Companion. Instruction Manual

VDBTLE24. BTLE Single Mode Module with USB. Description. Applications

MODEL W Power Amplifier

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

Transcription:

Minnesota Rules, Chapter 4732 X-ray Revision PROPOSED DRAFT GAUGING X-RAY SYSTEMS, 1.0 4732.#### GAUGING X-RAY SYSTEMS. Subpart 1. Applicability. A registrant s gauging x-ray system must comply with the requirements of this part. X-RAY SYSTEMS Subp. 2. Safety Device. A registrant is responsible for the requirements of this subpart. Commented [JC(1]: OR; 333-115-0010 A safety device for a gauging x-ray system must: A. prevent the entry of any portion of an individual's body into the useful beam; or B. provide a shut-off feature that prevents any part of an individual s body from being exposed to the useful beam; and C. disable the high voltage automatically before loss of any shielding in the event of Commented [JC(2]: ANSI N43.8 3.1.2(materials?) fire or elevated temperatures. Subp. 3. Warning lights and devices. Commented [JC(3]: Similar to NC, TX, ANSI, OH OR has Beam-on A. A discernible and visible warning light labeled with the words "X-RAY ON, or other visible warning indicator, must: (1) be located on or near a switch that energizes an x-ray tube; and (2) illuminate only when the tube is energized.

B. Warning devices must be labeled so that the purpose is easily identified. For gauging x-ray systems installed after the effective date of this part, a warning device must have a fail-safe design. C. An x-ray tube "on-off" status indicator must be located near the radiation source housing. This requirement may be met if the warning indicators are visible and discernible by anyone near the useful beam. D. The shutter "open-closed" status indicator must be located near each beam port Commented [BB(4]: Focus Group: Do shutters apply? on the radiation source housing if the useful beam is controlled with a shutter. This requirement may be met if the status light at the control panel is visible and discernible by anyone near the useful beam. Subp. 4. Beam ports. Unused ports on radiation source housings must be secured in the closed position that prevents opening. Commented [JC(5]: TX: ports : 289.228, (e, 2, c, 3) Similar: TN, OR Subp. 5. Shutters. For a gauging x-ray system designed with shutters: Commented [JC(6]: Ohio; SSRCR A. each beam port on the radiation source housing must be equipped with shutters that cannot be opened unless either a collimator or a coupling has been connected to the beam port; and B. unused collimators on radiation source housing must be secured in the closed position, or mechanically blocked. 2 Subp. 6. Labeling. A registrant is responsible for labeling gauging x-ray systems according to this subpart.

A. A gauging x-ray system must be labeled near any switch that energizes an x-ray tube with a visible and discernible sign bearing the radiation symbol and the words "CAUTION RADIATION - THIS EQUIPMENT PRODUCES IONIZING Commented [BB(7]: ANSI N43.8-2008 (3.8.2), Similar: PA, OR Few states have, Warning-X-rays do not place hands in jaws of gauge. TN, TX, OR Few states have, Caution- High Intensity X-ray Beam OR, NC RADIATION WHEN ENERGIZED", or other words having similar meaning. B. A gauging x-ray system must be labeled at or near any switch that energizes an x- ray tube with a visible and discernible sign bearing the radiation symbol and the words Warning-X-rays do not place hands in jaws of gauge, or other words having similar meaning. Subp. 7. Safety device evaluation. A registrant is responsible for the safety device evaluation of a gauging x-ray system safety device: A. upon installation and Commented [BB(8]: ANSI N43.8-2008 (3.8.2), Similar: PA, OR Few states have, Warning-X-rays do not place hands in jaws of gauge. TN, TX, OR Few states have, Caution- High Intensity X-ray Beam OR, NC Commented [JC(9]: Focus Group: Thoughts? Some states have jaws of gauge language. Also consider: A gauging x-ray system must be labeled at or near the x-ray beam port to identify the location of the beam with the words CAUTION - HIGH INTENSITY X-RAY BEAM", or other words having similar meaning. Commented [JC(10]: TX has 12 month testing for interlocks TN, OR: test quarterly B. at intervals not to exceed 180 days. Commented [JC(11]: NC: 3 months C. For purposes of this subpart, a safety device evaluation includes: (1) safety device under subpart 2; (2) shutters; (3) warning lights; (4) warning devices; and (5) required emergency shut-off switches. D. A safety device evaluation must verify that: Commented [JC(12]: Focus Group: We were not able to find emergency shut-off switches in other states regulations. Is it needed here? (1) all gauging x-ray system safety devices are functioning as designed; and 3

(2) all labels are legible and visible. E. If a gauging x-ray system safety device is not functioning as designed, then it must be: (1) labeled immediately as defective; and (2) removed from service until the safety device is repaired. F. A registrant must maintain a record of safety device evaluations for a gauging x- Commented [JC(13]: SSRCR; page H9, Section H.6 (j) ray system. The record must include: (1) the dates of evaluations; (2) a list of the safety devices evaluated; (3) the results of the evaluation; (4) the name of the individual performing the evaluation; and (5) corrective actions recommended and performed for any safety device that fails the required evaluation. G. When a gauging x-ray system is returned to service after being locked-out and tagged, it must be evaluated before use if the date of the last safety device evaluation exceeds the six-month interval. H. A gauging x-ray system that is locked out and tagged DO NOT USE by the radiation safety officer is exempt from this subpart. 4 Subp. 8. Radiation emission limit. A gauging x-ray system must be located and arranged to include sufficient shielding or access controls to prevent radiation emission in any area

surrounding the local component group which may result in a dose to an individual in excess of the dose limits under part 4732.####. The dose limits must be met at the maximum operating parameters. Subp. 9. Useful beam attenuation. A registrant must provide protective measures when the useful beam is not intercepted by the detector device under all conditions of operation to avoid exposure to any individual from the useful beam. Protective measures include auxiliary shielding or administrative procedures. AREA SURVEY REQUIREMENTS Subp. 10. Area survey. A registrant is responsible for an area survey of gauging x-ray system that complies with the radiation emission requirements under subpart 8. Qualified personnel must perform an area survey: A. upon installation or relocation of the gauging x-ray system; B. after any maintenance that requires the disassembly or repair of components that affects the output of a gauging x-ray system; and C. with radiation survey instruments calibrated according to part 4732.####. Commented [JC(14]: Focus Group: Do we include shielding and beam attenuation here? CONDITIONS OF OPERATION Subp. 11. Safety procedures. A registrant must develop and comply with operating and Commented [JC(15]: SSRCR; page H4, in definitions emergency procedures for a gauging x-ray system. A. Operating and emergency procedures may be maintained in electronic or written form; 5

B. Operating and emergency procedures must include: (1) storage and security of a gauging x-ray system to prevent unauthorized use, removal, or accidental production of ionizing radiation when the gauging x-ray system is not under the control and constant surveillance of an operator or the registrant; (2) Verification of the operability and safety of the gauging x-ray system before each use and any corrective measures performed; (3) equipment malfunctions; (4) minimizing exposure of individuals in the event of an accident; (5) notifying proper personnel in the event of an accident; and (6) locked out and tagged. C. No individual may operate a gauging x-ray system in any manner other than Commented [BB(16]: SSRCR; page H8, section H.6. (h) that specified in the operating procedures unless the individual has obtained written approval from the radiation safety officer (RSO). D. Operating and emergency procedures must be available to an operator of a Commented [BB(17]: SSRCR, Sec. I.10 (f), gauging x-ray system. Subp. 12. Repair and modification. Only qualified personnel may repair or make modifications to a registrant s gauging x-ray system. A. The x-ray power source must be locked out and tagged for routine shutdown before repairing or modifying a gauging x-ray system. B. Qualified personnel must verify that the x-ray source is off, and remains off, before an operation that involves removing the covers, shielding materials, 6

radiation source housing, modifications to shutters, collimators, or useful beam attenuators. Subp. 13. Records. 7