Model Sono-Trak Transit Time

Similar documents
UTM10 Series Ultrasonic Transit-time Flowmeters

HTTF Transit Time Ultrasonic Flow Meter

ULTRASONIC FLOW METER FT101

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

Applications Features

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

Ambient Conditions. Operating Conditions. Pressure

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Digital flow transmitter for continuous flow measurement

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Advanced instrumentation solutions crafted with highest precision

The transducer component converts the measured signal and displays the actual value.

Electromagnetic Flow Transmitter

RCM DIRECT READING FLOWMETER

Digital flow ELEMENT transmitter for continuous flow measurement

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

mass flowmeter for compressed air

DigitalFlow TM CTF878

Digital conductivity transmitter

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Signet 9950 Dual Channel Transmitter

Technical Specifications

INLINE flowmeter for continuous flow measurement

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Digital flow ELEMENT transmitter for continuous flow measurement

Sarasota CM200 Sarasota HME900 Density Converter Electronics

INLINE flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement

Digital inductive conductivity transmitter

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

INLINE flowmeter for continuous flow measurement

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

Flow Measurement SITRANS F US Clamp-on

Ultrasonic level transmitter, non-contact

PROCESS & TEMPERATURE CONTROLLERS

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

USER MANUAL MODEL CSLFC ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL CLARK SONIC MODEL CSLFC

OPTISONIC 6300 Technical Datasheet

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Electro-Magnetic Flowmeters COPA-XE

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Non-Submersible Industrial Pressure Transducer

ph or ORP Transmitter

Valve Island with Electronic I/O

Proven Measurement for A World of Applications

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Signet 8900 Multi-Parameter Controller

8900 Multi-Parameter Controller

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Rosemount 3101, 3102, and 3105

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

Specification DataFile

B850 Boiler House Energy Monitor

FLOMID FX Electromagnetic Flowmeter

Signet 9950 Dual Channel Transmitter

LST400 Ultrasonic level / open channel flow transmitter

Digital flowmeter for continuous flow measurement

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

Digital flowmeter for continuous flow measurement

Signet 9900 Transmitter

Echotel Trident 91S/92S Ultrasonic Level Switches

OPTISONIC 6300 P Technical Datasheet

Echotel Model 910 Ultrasonic Level Switch

DigitalFlow DF868 Panametrics Liquid Ultrasonic Flowmeter. GE Sensing. Applications. Features

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Digital batch controller

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

SonoMeter 31 Energy Meters

Magnetostrictive Level Transmitter

4.00 ULTRASONIC ANALYZER

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Figure 3. 1 ½ Nutating Disc with R-10 register

Electromagnetic flowmeters and switches DWM 1000/2000

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family

Signet 9900 Transmitter

B850 Boiler House Energy Monitor

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Signet 9900 Transmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

AccuSolar SOLAR POWERED SYSTEM

OPTIMASS 1000 Technical Datasheet

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

S L n u. M e. E n te r. Transmitter: Flow range: 0 ~ ±40ft/s (0 ~ ±12m/s) Accuracy: ±1.0% Repeatability: 0.3% Outputs: OCT, KHz

Flow Measurement SITRANS F M

Transcription:

Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic technology. This easy-to-install and easy-to-program system provides the ideal solution for low-cost, reliable, and maintenance-free measurement. Benefits Fast and easy installation Rugged and maintenancefree with no moving parts Fits pipe sizes from 2 to 100" (50 to 2540 mm) Non-invasive, bi-directional measurement Reliable and accurate readings provides ±2.0% of rate accuracy and ±0.1% repeatability Features Simple, clamp-on design Time domain expansion technology used to increase resolution Flexible, field-programmable EZ-Logic user interface NEMA 6-rated transducer housings Flexible module I/O design Built-in infrared capability for optional PC interface Applications Ideally suited for: Deionized water Ultrapure water General water Acids Solvents Over view The Sono-Trak Transit Time meter delivers performance excellence in a non-invasive, bi-directional, ultrasonic metering system. Consisting of simple, clamp-on transducers and a menu-driven programmable display, the system eliminates mechanical wear, drift, and pressure drop problems associated with traditional technologies making it the ideal choice for new installations and system retrofits. This exceptionally compatible, reliable, and accurate metering solution is suitable for clean, swirl-free liquids in most industrial applications. Compatible and Reliable The Sono-Trak Transit Time meter fits pipe sizes from 2 to 100" (50 to 2540 mm) and accommodates a wide variety of pipe materials. In addition, it can sustain high-temperature and high-pressure conditions. With no orifice plates or other moving parts to wear, recalibrate, or maintain, the Sono-Trak Transit Time meter offers ±0.1% of rate repeatability. Non-contact fluid measurement not only allows installation during, but also eliminates chemical corrosion, caking, and risk of fluid contamination.

e m c o f l o w s y s t e m s Highly Accurate The Sono-Trak Transit Time meter uses advanced ultrasonic technology for accurate measurement. Transducers operate as both transmitter and receiver of signals, with one transducer upstream and one downstream. By taking bi-directional measurement transmitting high-frequency sound waves through the pipe into the stream in both directions the electronics determine the difference in time (transit time) of the upstream and downstream signals. Advanced digital signal processing translates the transit time and calculates the average fluid velocity delivering ± 2.0% of rate accuracy in a typical field installation. Response time is user selectable from 0.3 to 30 seconds. Optional Input / Output Modules Custom electronics configuration is made possible through multiple I/O module options: 4 to 20 ma Output Field configurable as a 2-wire active or passive transmitter, 800 Ω maximum resistance Frequency Output Open collector, field configurable for 0 to1000 Hz or 0 to 10,000 Hz output Dual Relay Output Used for batching, high/low alarms, empty pipe detection, and error indication RS-232 Communication Used to monitor information RS-485 Communication Used to network up to 100 units together in a master/slave configuration Signal moving upstream Upstream velocity = speed of sound - fluid velocity Signal moving downstream Downstream velocity = speed of sound + fluid velocity Display Module An easy-to-program, wall-mounted display employs field-programmable EZ-Logic software. The default data output alternates between continuous, real-time rate readings and total readings shown in English and Metric user-selectable engineering units. With buffet-style input/output (I/O) module options, the electronics configuration is easily customized. Two I/O sockets will accept multiple modules, including pulse, analog, relay, RS-232, or RS-485. To streamline configuration, a built-in infrared communication port is available with optional Windows -compatible software, allowing multiple meters to be programmed with a personal computer. 2

g e n e r a l s p e c i f i c a t i o n s Installation Considerations Transducer Mounting The Sono-Trak Transit Time meter's non-invasive design uses stainless steel quick clamps and heavy-duty cables that are pre-terminated to facilitate fast and easy installation. The transducers mount on the outside of a process pipe with one transducer upstream and one downstream. Installation is non-intrusive as no sensor is inserted into the pipe. Transducer spacing is dependent upon pipe size and is calculated automatically during set-up. Straight run requirements are typically 10 diameters upstream and 5 diameters downstream. Accurate results may be achieved with straight run of 5 diameters upstream and 3 diameters downstream. Upstream valves and other piping configurations may require more straight run. Ver tical Pipe Mounting The recommended direction in a vertical pipe is upwards. correct incorrect Horizontal Pipe Mounting Transducer should be mounted on a horizontal pipe as shown. correct incorrect 3

e m c o f l o w s y s t e m s Zero Point Adjustment For best accuracy, a zero point setting must be made with a full pipe at no during initial start-up. Air/ Gas Entrapment Excess gas entrapment can scatter or reflect the sound wave, causing inaccurate measurement. Allowable air/gas entrapment is 2%. Pipe Material The property of the pipe material can affect the performance of the meter. Good Results Caution Needed Do Not Use On Most metallic Cast iron Cement Plastic Lined pipes Pipes with internal deposits or severe corrosion Sonic Wave Forms To obtain the best possible signal strength, the following mounting options are recommended: 2 to 2.5" (DN50 to DN65) = W 3 to 12" (DN80 to DN300) = V 14 to 100" (DN350 to DN2500) = Z W V Z Cabling The Sono-Trak Transit Time includes a standard cable length of 25' (76 m) and optional lengths of 50' (15.2 m) and 75' (22.8 m). Custom cable lengths of 76 to 1000' (23.1 to 304.8 m) are also available. 4

g e n e r a l s p e c i f i c a t i o n s Specifications Performance Accuracy Factory tested at ±0.5% of rate. 1 Typical field installation is ±2.0% of rate. Field performance is dependant on the accuracy of the pipe s internal diameter and wall thickness measurements as well as straight run conditions. Repeatability ±0.1% of rate Response Time Adjustable from.3 to 30 seconds 1 Factory test conditions: water at 70 F (21 C), velocity > 1 ft/sec on a 6" stainless steel pipe Physical Materials Wetted parts None Electronics housing Transducer housing Reinforced polycarbonate with stainless steel hardware NEMA 4X (IP65) 400 F (204 C): Torlon /Vespel /Stainless Steel; NEMA 6 (IP68) 250 F (121 C): Delrin /Ultem /Stainless Steel; NEMA 6 (IP68) Sensor cables Clamps Polyurethane armored coaxial Stainless Steel Cable Lengths Standard 25' (7.6 m) Options 50' (15.2 m) 75' (22.8 m) Custom 76 to 1000' (23.1 to 304.8 m) Weight Electronics 4.5 lb (2 kg) Transducers 4.5 lb (2.05 kg) for two transducers with 25' (7.6 m) of cable Size Electronics 7" (H) x 7" (W) x 5" (D) 177.8 mm (H) x 177.8 mm (W) x 127 mm (D) Maximum Transducer Cable Length Cable Connection Transducer 1000' (304.8 m) Standard submersible 2" (H) x 3.25" (W) x 1.45" (D) 50.8 mm (H) x 82.6 mm (W) x 36.8 mm (D) Mounting Electronics Remote wall CSA Approval Transducer Class I Div II Groups A, B, C, D Class II and Class III Groups E, F External, adjustable clamp 5

e m c o f l o w s y s t e m s Operating Specifications Applied Pipeline Sizes Measurable Fluids Measurable Flow Velocities Ambient Temperature Limit 2 to 100" (50 to 2540 mm) Most common liquids from waste water to petrochemical products Liquid -40 to 40 ft/sec (-12 to12 m/sec) -40 to 140ºF (-40 to 60ºC) Process Temperature Limit Standard -40 to 250ºF (-40 to120ºc) Ambient Humidity Limit Process Pressure Limit Power Requirements Input/Output Modules High temp option Up to 95% RH, non-condensing Not applicable Field configurable for AC or DC operation Power Consumption -40 to 400ºF (-40 to 205ºC) 12 to 24 VDC 115 VAC, 50/60 Hz (± 10%) 230 VAC, 50/60 Hz (± 10%) > 5 W A maximum of two outputs can be selected. All input/output modules are optically isolated up to 2,500 V against ground loops and electrical surges. 4 to 20 ma Output Field configurable as a 2-wire active or passive transmitter, 800 Ω maximum resistance Frequency Output Open collector, field configurable for 0 to 1000 Hz or 0 to 10,000 Hz output, 20 ma maximum (50% of duty cycle) Dual Relay Output RS485 Interface Two SPDT form C contacts independently controlled; 175 V, ¼ A switch, 1 A carry current, 0.2 Ω resistance. Used for batching, high/low alarms, empty pipe detection, and error indication Used to network up to 100 units together in a master/slave configuration using built-in software and communications protocol. Supports 57.6 kbd communications, up to 1000' (304.8 m) Standard Interface RS232 Interface Used to monitor information. Supports up to 57.6 kbd communications, (19.2 kbd @ 50') LCD backlit display with 8-character large numeric and 8-character small alphanumeric. Four button menu-driven EZ-Logic interface for programming Flow Units English units User-selectable from gallons, cubic feet, millions of gallons, oil barrels, liquid barrels, feet, and pounds. Note: Gallons refers to U.S. Gallons. Time Units Metric units Liters, meters, cubic meters, and kilograms User-selectable from seconds, minutes, hours and days 6

g e n e r a l s p e c i f i c a t i o n s Model Selection Category Electronics 2-line backlit display with 4-button keypad I/O Port 1 None Suffix Codes ST-30 4-20 ma output A Frequency output Dual relay output (dry contact) RS-232 interface RS-485 interface I/O Port 2 None N F R RS2 RS4 4-20 ma output A Frequency output Dual relay output (dry contact) RS-232 interface RS-485 interface Process Temperature -40 to 250ºF (-40 to 120ºC) 250-40 to 400ºF (-40 to 205ºC) 400 Transducers Submersible 1 Cable Length (specify length) 25' (7.6 m) 25 50' (15.2 m) 50 75' (22.8 m) 75 76 to 1000' (23.1 to 304.8 m) xx Pipe Clamp (specify pipe size) 2 to 12" (50 to 300 mm) 12 14 to 24" (350 to 600 mm) 24 26 to 36" (650 to 900 mm) 36 38 to 100" (950 to 2540 mm) xx Example ST-30- A- N- 250-1- 25-12 N F R RS2 RS4 7

e m c o f l o w s y s t e m s Accessories Description Part Number Windows communication software for IR Port/RS232/RS485 modules 6001100 Infrared serial communicator for wireless PC interface 1-800-138 Transducer cable conduit adapter ¾" NPT (requires 2 pieces) 340790 Low temp transducer and 25' of cable -40 to 250ºF (-40 to 120ºC)* 011143-125 High temp transducer and 25' of cable -40 to 400ºF (-40 to 205ºC)* 011143-225 * If a pair of transducers is required, two units of the same part number must be ordered. EMCO Flow Systems is a division of Spirax Sarco, Inc. 1150 Northpoint Blvd. Blythewood, SC 29016 For information on EMCO industrial products, contact: EMCO Flow Systems 2150 Miller Drive Longmont, CO 80501 T: 800.356.9362 or 303.682.7060 F: 303.682.7069 sales@emco.com www.emco.com Spirax Sarco, Inc. 2007 All rights reserved. Printed in U.S.A. SL-SONOTK-350-03 2M 1/07 Sono-Trak and EZ-Logic are trademarks of Spirax Sarco, Inc. Windows is a trademark of the Microsoft Corporation, Delrin and Vespel are trademarks of E.I. du Pont de Nemours and Company, Torlon is a trademark of BP Amoco Polymers, and Ultem is a trademark of the General Electric Company.