K ARICA ROUND SHOWER ENCLOSURE

Similar documents
BASIC TOOLS AND MATERIALS NEEDED. Introduction HOW TO CARE FOR YOUR DOOR

IMPORTANT: One Corner Entry Shower Door requires two cartons.

FOLIO COUNTERTOP LAVATORY

Two Panel Frameless Bypass Door

REVIVAL PEDESTAL LAVATORIES

Angled 2200A INSTALLATION INSTRUCTIONS. Series MODEL NOS

TROCADERO VITREOUS CHINA BIDET

SHOWERGLIDE 600B, 690B, 692B, SERIES

Series----SP3600A SHOWER DOOR

300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT

1038 SERIES DELUXE FRAMELESS PIVOT SHOWER DOOR

738 SERIES PIVOT SHOWER DOOR

694 SERIES NEO-ANGLE PIVOT SHOWER ENCLOSURE

340 & 350 SERIES BATH ENCLOSURES

ProLine PL60 - PL70 - PL80 RETURN PANEL SUPPLEMENT

340 & 350 SERIES DELUXE FRAMELESS BYPASS

ProLine PL80 HEAVY FRAMELESS BYPASS BATH ENCLOSURE

340D & 350D SERIES FRAMELESS BYPASS BATH ENCLOSURES

340D / 350D SERIES FRAMELESS BYPASS BATH ENCLOSURES

1040 & 1050 SERIES HEAVY FRAMELESS BYPASS BATH ENCLOSURE

890 SERIES PIVOT STEAM DOOR

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

OSBORNE SHOWER DOOR INSTALLATION

SERIES: CONFIGURATION: MOUNTING PACKAGE: 1200 Door-Door Frameless, sliding door

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

Model 750 Illustrated Installation Instructions Contractors Wardrobe

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

Model 5400H / 7000H Illustrated Installation Instructions

CAUTION. It is the responsibility of the INSTALLER to ensure that the installation complies with council and or local authority bylaws.

DEVONSHIRE ELOSIS ORDERING INFORMATION PARTS INSTALLATION INSTRUCTIONS MIRROR CABINET. , 2005 Copyright Kohler China Ltd.

Frameless Fixed Panel Slider QCI5279

Model 6100 Illustrated Installation Instructions Contractors Wardrobe

640S & 650S SERIES FRAMED BYPASS BATH ENCLOSURES

ProLine PL60 HEAVY FRAMELESS BYPASS BATH ENCLOSURE

INSTALLATION INSTRUCTIONS

UNIT No FRAMELESS PIVOT SHOWER DOOR

391 SERIES STIKSTALL TM SHOWER ENCLOSURE

Double Swing Door With Header QCI5114

Allora ALCOVE ENCLOSURE INSTALLATION BEFORE INSTALLATION CHECK THAT YOUR ALLORA SHOWER ENCLOSURE SYSTEM IS UNDAMAGED

Frameless Door QCI5284

HEAVY GLASS HINGE INSTALLATION INSTRUCTIONS HINGE PARTS LIST. Tel: G D K I

Double Frameless Swing Door QCI5247

Frameless Fixed Panel Slider

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05

UNIT No. 8150/9150 SHOWER ENCLOSURE

TUB SHOWER Framed Sliding Enclosure

Frameless Bypass Slider

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

394 SERIES STIKSTALL TM SHOWER ENCLOSURE

Frameless Bypass Slider

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE 1400A-1700A-1800A

A-935 RODA WALL MOUNT HINGES

INSTALLATION INSTRUCTIONS

AM500-U Installation Guide

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS

UNIT No. 15 & 16 SHOWER DOOR INSTALLATION INSTRUCTIONS

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE

VITREO X SHOWER / TUB DOOR INSTALLATION INSTRUCTIONS

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D

Frameless Heavy Glass Door with Wall Mount Hinges

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

Unit No. 135, 735 Deluxe Pivot Inline Door & Panel Shower Enclosure

ESSENCE. Shower / Tub Door Installaion Instructions

Frameless Inline Door QCI5254

Cardo DOOR & RETURN SHOWER ENCLOSURE INSTALLATION PLEASE READ THESE INSTRUCTIONS CAREFULLY.

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5232

FRAMED SLIDING DOOR FOR TUB OR SHOWER ENCLOSURE 6150A-7150A

tile redi redi DOOR Redi Swing SERIES: CONFIGURATION: MOUNTING PACKAGE:

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Framed Single Swing Shower Enclosure Steam Continuous Hinge

GLASSCRAFTERS, INC 193 Veterans Blvd., Carlstadt, NJ Frameless Sliding Door with Fixed Panel Shower/Tub Enclosure Installation Instructions

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 4400A-4500A

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Frameless Inline Door With Return QCI5263

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

3/8 FRAMELESS BYPASS SLIDING SHOWER ENCLOSURE

Unit No. 135, 735 Deluxe Pivot Inline Door & Panel Shower Enclosure

INSTALLATION INSTRUCTIONS

640D & 650D SERIES FRAMED BYPASS BATH ENCLOSURES

Unit No. 6150, 7150 Deluxe Framed Sliding Tub/Shower Enclosure

UNIT No. 135/735 THIN-LINE SHOWER ENCLOSURE

Installation Instructions with 90 Degree Return Panel -- Model E-DP9. Model Semi-Frameless Door & Panel

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

FIXED PANEL SLIDER QCI5241

REVIVAL ACCESSORIES BEFORE YOU BEGIN A. HOW TO USE THESE INSTRUCTIONS B. PRODUCT NOTES C. ORDERING INFORMATION D. REQUIRED TOOLS AND MATERIALS

Sector Shower Enclosure Installation Instructions

791 SERIES STIKSTALL TM SHOWER ENCLOSURE

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

INSTALLATION INSTRUCTIONS. UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE

TETRA SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

4-lite Patio Door. Installation Instructions

794 SERIES STIKSTALL TM SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 90º PANEL

ESSENCE - H SHOWER / TUB DOOR INSTALLATION INSTRUCTIONS

FRAMED SLIDING DOOR FOR TUB OR SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Model 2400/4000 Illustrated Installation Instructions

INOVO 2-LITE SLIDING PATIO DOOR

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Transcription:

K-7050 ARICA ROUND SHOWER ENCLOSURE 1. BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information in these instructions is based on the latest product information available at the time of publication. Kohler Co. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information please leave instructions for the consumer. SPECIFICATIONS K-7050 Shower Enclosure: 3 x 3 x 72 H TOOLS AND MATERIALS REQUIRED Conventional woodworking tools Measuring tape Pencil Safety glasses Screwdriver - Flat Caulking gun Masking tape Silicone Sealant (RTV) Center punch Hammer Screwdriver - Phillips Electric drill Drill bit - 5/1 Masonry bit for ceramic tile - 5/1 PREPARATION Before starting the installation, lay out and identify all the parts. Use the exploded view parts list and illustrations on pages 8 through 10 for reference. Install shower receptor in accordance with instructions supplied with receptor. CAUTION: Tempered glass cannot be cut. NOTE: For ease of installation, it is recommended that two people install shower enclosure. 11897-2-AB 2000 Kohler Co.

2. INSTALLATION A. INSTALL FIXED PANELS NOTE: Assemble door enclosure on a clean and non-abrasive surface (such as a drop cloth) to prevent damage. Position the right-hand fixed panel onto the top and bottom track and align the holes in the glass with the installed female patch. Align the hole in the fixed panel male patch with the screw hole in the female patch and fasten with four M x 10 Flat Sockethead screws. Use the hex wrench provided to fasten the screws but do not tighten the screws at this time. Repeat the above procedures to install the left-hand fixed panel. Right-Hand Fixed Panel Installed Fixed Panel Patch - Female Fixed Panel Patch - Male M x 10 Flat Sockethead Screw Screw Cover Top Bottom Left-Hand Fixed Panel B. INSTALL MOVING PANELS Apply supplied silicone lubricant to the bottom track groove, making sure to apply to the entire length of the groove. Apply Silicone Lubricant to the Bottom Track Groove 11897-2-AB 2

Right-Hand Panels At the bottom end of the right-hand moving panel, disengage, if necessary, the two catches with the turngrip levers. Position the moving right-hand panel with the rollers up and the magnet side towards the right-hand fixed panel. Catch Stops Turngrip Lever Fit the first roller (nearest magnet side of moving panel) into the top track roller groove of the fixed panel. Fit the second roller (near outside edge of moving panel) into the groove and slide the right-hand moving panel into the top track of the right-hand fixed panel. Catch in the Disengaged Position Turngrip Lever in the Disengaged Position Left-Hand Panels At the bottom end of the left-hand moving panel, disengage, if necessary, the two catches with the turngrip levers. Position the moving left-hand panel with the rollers up and the magnet side towards the left-hand fixed panel. Magnet Side Right-Hand Moving Panel Rollers Top Rollers Fit the first roller (nearest magnet side of moving panel) into the top track roller groove of the fixed panel. Fit the second roller (near outside edge of moving panel) into the groove and slide the left-hand moving panel into the top track of the left-hand fixed panel. Right-Hand Fixed Panel Bottom Left-Hand Fixed Panel Magnet Side Left-Hand Moving Panel C. INSTALL WALL JAMB / EXPANDER JAMB ASSEMBLY Position each wall jamb/expander jamb assembly onto the top and bottom tracks. Align each end of the assemblies with the top and bottom track screwports and fasten with twelve #-20 x 1 panhead screws but do not tighten. Top/Bottom Track Wall Jamb/Expander Jamb Assembly #-20 x 1 Panhead Screw Top Bottom 3 11897-2-AB

D. ADJUST DOOR ASSEMBLY AND TIGHTEN SCREWS Measure diagonally across each side of the door assembly and adjust, if necessary, for equal measurements on each side. Fixed Panel Patch Refer to Install Fixed Panels on page 2 for location of patch screws. Tighten the fixed panel patch screws with the hex wrench provided and insert the screw covers over the screw heads. Lift bottom of moving panel and tilt up and away from fixed panel to gain access to lower inside patch screws. Now tighten the twelve #-20 x 1 panhead screws that attach the top and bottom tracks to the wall jamb/expander jamb assembly. Refer to Step C. Fixed Panel Patch E. ENGAGE CATCHES Place the catch into the bottom track recess with the catch and turngrip lever disengaged. Catch Stops Turngrip Lever Catch in the Disengaged Position Turngrip Lever in the Disengaged Position Move the turngrip lever to the position shown at right until the catch stops. Turngrip Lever in the Engaged Position Move the lever back one step as shown to allow for sufficient operating clearance. Move Lever Back One Step Repeat for the remaining three catches. Bottom Track Catch in the Engaged Position Stand door assembly upright. 11897-2-AB 4

F. INSTALL DOOR ENCLOSURE NOTE: Wear Safety Glasses. The following steps explain installing wall jambs using hollow wall anchors. Align door assembly to receptor and place onto the shower floor ledge with the bottom track 3/1 from the edge of the shower floor ledge. Adjust the expander jambs by turning the two adjustment screws on each side. Turning the screws counterclockwise will increase the width of the assembly; turning the screws clockwise decreases the width of the assembly. Adjust each expander jamb until both wall jambs touch the wall at the bottom. Adjust top until jambs touch the wall. Adjustment Screw After adjusting, mark the three hole locations through the locator holes in each wall jamb and expander jamb. Move the door assembly to one side and lightly center punch the three hole locations on the wall. On ceramic tile, use a center punch to nick the surface glaze. Tap the punch lightly with a hammer so as not to crack the tile. Drill three holes into each wall with a 5/1 drill bit. Use a 5/1 masonry bit for ceramic tile. After drilling all six holes, thoroughly clean the shower floor ledge and wall. Insert the hollow wall anchors into all six 5/1 drilled holes. Install the door assembly into opening and align the locator holes with the holes in the wall. Make minor adjustments using the adjustment screws, as necessary. Secure sides of enclosure at bottom by installing two #8-18 x 1-1/4 panhead screws through each expander jamb and wall jamb into the installed anchors in wall. Repeat, securing the top of the enclosure and lastly the middle. 5 11897-2-AB

G. FINAL ADJUSTMENT / ATTACH ROLLER PATCH COVERS If necessary, adjust the moving panels using the top rollers. Disengage catches at the bottom track, refer to Install Moving Panels on page 2. Loosen roller screws and adjust panels by shifting panels and re-positioning until level. After adjusting panels, tighten roller screws. Insert the four roller patch covers. Cover Male Roller Patch H. INSTALL INTERLOCK BASE AND SEAL Slide both interlock seals into the interlock bases. Push an interlock base onto the trailing edge of each moving panel. Trailing Edge of Moving Panel If interference when closing the door is excessive, the interlock seal can be changed to the depth shown. Interlock Base Interlock Seal Excessive Interference If there is not enough interference when closing the door, the interlock seal can be changed to the depth shown. Interlock Base Interlock Seal Insufficient Interference 11897-2-AB

I. INSTALL COVERS AND GASKETS IMPORTANT: All adjustments should be made to the door before installing the wall jamb cover and the expander jamb cover. Follow the sequence below to install covers and glazing gasket: From inside the shower, install the wall jamb cover into the wall jamb. From outside the shower, position the glazing gasket where the fixed glass panel is inserted into the expander jamb. Push the gasket into place down the length of the glass panel. Inside the shower, install the expander jamb cover into the expander jamb with the leg of the cover towards the fixed glass panel. Repeat the above procedures for the opposite expander jamb. Wall Jamb Cover Wall Jamb Expander Jamb Glazing Gasket Fixed Glass Panel Expander Jamb Cover Leg J. SEALING Thoroughly clean all dust, dirt and grease from the bottom frame and shower ledge surfaces to be sealed. Make sure surfaces are dry. CAUTION: Apply silicone sealant around the outside of the door only. Sealant applied to the inside of the door will cause leakage and damage. Carefully apply a bead of silicone sealant around the outside (dry side) of door where: 1) Bottom frame meets the shower ledge. 2) Wall jambs meet the shower walls. 7 11897-2-AB

3. EXPLODED PARTS LIST ITEM DESCRIPTION QTY. 1 Top/Bottom Track 2 2 Interlock Seal 2 3 Interlock Base 2 4 Left-Hand Moving Glass Panel 1 5 Right-Hand Moving Glass Panel 1 Moving Panel Wheel Patch Female 8 7 Roller 4 8 Moving Panel Wheel Patch Male 4 9 #8 Lockwasher 4 10 M4 x 0.7 Machine Screw 4 11 Roller Patch Cover 4 M x 10 Flat Sockethead Screw 1 13 Frame End Cap 4 14 Handle End Cap 8 15 Handle 4 1 Magnet 2 17 Moving Panel Cam Patch Screw Cover 4 18 Turngrip Lever 4 19 Patch Fitting Body 4 20 Catch 4 21 Expander Jamb Cover 2 22 Fixed Panel Glass Panel 2 23 Glazing Gasket 2 Fixed Panel Patch Screw Cover 8 Fixed Panel Patch Male 8 2 Fixed Panel Patch Female 8 #-20 x 3/8 Philips Flathead Screw 8 28 Expander Jamb Large Spacer Block 4 29 Expander Jamb Small Spacer Block 4 30 #-20 x 1 Philips Panhead Screw 31 Wall Jamb Cover 2 32 Adjustment Screw Retainer 4 33 Adjustment Screw 4 34 Expander Jamb 2 35 Wall Jamb 2 3 #8-18 x 1-1/4 Philips Panhead Screw 37 Hollow Wall Anchor Hex Wrench (not shown) 1 Silicone Lubricant (not shown) 1 11897-2-AB 8

1 3 8 7 11 11 10 11 11 10 10 9 10 14 9 14 8 9 9 14 8 7 13 13 7 8 15 7 3 2 2 1 1 4 15 5 15 17 17 18 19 18 19 20 14 20 13 17 18 19 14 1 13 17 18 19 20 14 20 Center (Moving) Panels 9 11897-2-AB

10 11897-2-AB 37 3 35 34 33 32 31 30 29 28 2 23 22 21 21 22 23 28 3 37 37 3 28 2 32 2 30 29 33 2 33 28 29 30 31 3 37 35 32 2 37 3 37 3 32 30 2 29 2 34 2 33 Fixed Panels

4. IMPORTANT CONSUMER INFORMATION CONSUMER RESPONSIBILITIES Your Kohler Shower Enclosure will remain beautiful if you take care of it. It is recommended that you replace seals, when they show signs of wear, yellowing, or are not watertight. Refer to the exploded parts page and list for Kohler Service Parts. Water conditions in various parts of the country will determine any extra cleaning attention you may have to give your new shower enclosure. A simple routine of daily care will keep your shower enclosure looking like new. Kohler Co. does not recommend the use of harsh abrasive cleansers on any of its products. Harsh cleansers will damage the metal or glass finish on your shower enclosure. REQUESTING SERVICE Please take a moment to familiarize yourself with the Kohler Warranty, its benefits, and limitations. Kohler Co. and its distributors support you with one of the largest Service Networks of its type. Here s what you need to do if you require service: FIRST: Contact the dealer or contractor who sold and installed the product. They should be able to solve any problems you may have. SECOND: If your dealer or contractor cannot solve the problem, they will contact or supply you with the name of the local Kohler Distributor and the: KOHLER TECHNICAL SPECIALIST THIRD: If you are unable to obtain warranty service through either your contractor or Kohler Co. distributor, please write us directly at Kohler Co., Attn.: Customer Service Department, Kohler, WI 53044 U.S.A. FOURTH: Include all pertinent information regarding your claim, including a complete description of the product, model numbers, colors, finishes, and the date the product was installed. Include a description of the problem, and a photocopy of your invoice for the products involved. Also give us the name of the contractor and distributor. LIMITED ONE-YEAR WARRANTY Kohler plumbing fixtures and fittings are warranted free of manufacturing defects. Kohler Co. will, at its election, repair, replace, or make appropriate adjustment where Kohler Co. inspection discloses any such defects occurring in normal usage within one year after installation. Kohler Co. is not responsible for installation or removal costs. To obtain warranty service, contact Kohler Co. either through your Dealer or Plumbing Contractor, or by writing Kohler Co., Attn: Customer Service Department, 444 Highland Drive, Kohler, WI 53044 USA, or by calling 1-800-4-KOHLER from within the USA. Implied warranties, including that of merchantability or fitness for a particular purpose, are expressly limited in duration to the duration of this warranty. Kohler Co. disclaims any liability for special, incidental, or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of special, incidental, or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state. This limited warranty provides specific legal rights as they apply within the USA, and other rights may be available, but may vary from country to country. This is our exclusive written warranty. KOHLER CO., KOHLER, WISCONSIN 53044 11 11897-2-AB

11897-2-AB