GT SERIES. QuikStart Installation Guide #95228

Similar documents
GT SERIES. Multi-Tenant Entry Security. Quick Start Installation Guide

Hands-Free Color Video Multi-tenant Recording, Zoom & PanTilt features

AT-5888UV Programming Software for the AnyTone AT-5888UV

ATP-588 Programming Software for the Anytone AT-588

RPS-9000 Programming Software for the TYT TH-9000

ADMS-847 Programming Software for the Yaesu FT-847

ATP-5189 Programming Software for the Anytone AT-5189

WCS-D5100 Programming Software for the Icom ID-5100 Data

+GF+ SIGNET Temperature Transmitter Instructions

Happy Link Software INSTRUCTION MANUAL

GW-LE8 Selective Call Audio Module for Open Voice Systems Use with: C-ML/A, LEM-1DL/C, LEF, LAF-C, or LDF Masters

Digital Microscope. User Manual

MOST-H.U.R. MB V2. Head Unit Replacement interface for select Mercedes NTV-KIT736 BHM 09/23/16 NTV-DOC210

GT SYSTEM. Standard & Expanded System INSTALLATION MANUAL

FILM SCANNER P Instruction Manual

Ness M1RF Wireless Receiver

SERIAL COMMUNICATION. IDTECK Home e-training Center Home Product Catalog Product Manual Troubleshooting Purchase Order

The CO2 Sensor Calibration Kit

SKF TKTI. Thermal Camera Software. Instructions for use

MANUAL FOR DIRECT PRINTING

Video Intercom System Introduction

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10

USB Line Camera 8M. Coptonix GmbH

PROSOFT User Manual 3.03 VERSION

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

FAST TRACK READ ME FIRST! FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300. Contents. Nikon View... 25

Programming Instructions for: Kenwood TK-780, 880, 980, 981 (Version 2) W/ KCT-19 Option Connector For use with: Pyramid Communications Model

TW Series Digital Torque Wrenches Torque and Angle Model User Manual ASG, Division of Jergens, Inc.

AT-D868UV CodePlug Programming Guide

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado

BASIC USER GUIDE BASIC USER GUIDE CONTENTS. GeneralInformation... 2

MIDLAND PROGRAMING G14

Configuring a Mitsubishi PLC CC-Link Network

Maintenance Information

reference guide reference guide reference guide

M-16DX 16-Channel Digital Mixer

Connecting radios all over the world. Configuring and using SoftRadio on the dispatcher PC

PULSAR-EQUAL v 1.10 Art.No.: 1126

JF Series JF-1MD / JF-2MED. Reliable Security Simple Functionality Sophisticated Design

LONG RANGE REMOTE RECEIVER WITH TRANSMITTER FOR BUNGALOWS AND BANKS MODEL KE - 2 L R

A Step-by-step Guide to Installing and Configuring your Vonets VAP11G Wifi Bridge

inphoto ID Canon camera control software Automatic ID photography User Guide

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

igeacom User Guide V2.0

ID Photo Processor. Batch photo processing. User Guide

VBRC 4. Radio Communicator. Installer Manual

LCC-100 software User manual

SoundCheck 11 Quick Start Guide

AUDACITY TABLE OF CONTENTS

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

July 12, so it includes. below. 4. Import File). You. will need to. Page 1

BFoxCon Manual. Version 0.2 October 30, 2017

CTI Products RadioPro Dispatch Demo Installation and Test Drive Document # S For Version 8 Software

UHF TRANSCEIVER USER MANUAL

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

2012 Monitored Rehab Systems E1201 Manual Kneelax. Installation and user manual

Step One: Log into your MaineStreet account (use Internet Explorer as your browser for best functionality other browsers are buggy in this selection

MEASURE Evaluation. Global Positioning System Toolkit

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

Mini Hexapodinno. 18-DOF Robot

Using the VitalSource ebook App

MityCAM-B2521 EPIX XCAP User s Guide

GT SYSTEM. Multi Building System INSTALLATION MANUAL

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

Introduction to the Analog Discovery

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

Your Hammond Sk-series keyboard is shipped from the factory set for 120 V.A.C. power. To connect the Sk-series keyboard to A.C.

inphoto ID SLR Automatic ID photography With Canon SLR camera User Guide

Physical Inventory System User Manual. Version 19

Nikon D7100 Camera Kit. -Checklist and Operations Manual-

SoundCheck 12.0 Quick Start Guide

2. Now you need to create permissions for all of your reviewers. You need to be in the Administration Tab to do so. Your screen should look like this:

Sutron SatLink2 Troubleshooting Instructions

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Programming. Advanced Features

Blue Point Engineering

LH Series Sensor Configurator Software User Manual rev. D 1/11/2012

Analog Module D1-15P User Manual

Digital Function Generator

TABLE OF CONTENTS. Keypad Programming Manual 1

Magic Wand Portable Scanner with Auto-Feed Dock. PDSDK-ST470-VP-BX2 User Manual

Blue Bamboo P25 Device Manager Guide

The USB Brotherlink 4 - or Cartridge Cable

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

Vinyl Cutter Instruction Manual

AIT2000 CLASS B AIS TRANSPONDER

EMWIN User Training. For Colorado Front Range. September, 2007

Getting Started. Click the Start New Measurement Button. Select Year. Select Make. Select Model. If correct vehicle is selected, click next.

M F TYPE S R-SETUP. Setup Software

Setting Standards Connectors M 16

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com

Logging into Five9 Telephony

Entering Checkpoint Data

QAM Snare Navigator Quick Set-up Guide- Wi-Fi version

Installation & Quick Start Guide AIT2000 Class B AIS Transponder

Instant Engagement Pair Structures. User s Manual. Instant Engagement 2011 Kagan Publishing

INSTALLATION AND SETUP GUIDE

Instruction Manual. mass flow meter for compressed air. Druckluftbilanzierungssystem VARIOMASS VARIOMASS DIELEN MENU MAX ENTER EXIT MAX ENTER MENU

RP4-MZ11 Radio Replacement & Steering Wheel Control Interface for MazdaVehicles

DuraFon UHF Quick Ref. / FAQ Sheet

Transcription:

#95228 GT SERIES QuikStart Installation Guide ATTENTI: This is an abbreviated Installation Manual, addressing wiring and programming of the GT Series. The complete GT Series Installation Manual is located on the CD supplied with the GTBC Bus Control

SYSTEM WIRG: AUDIO LY DIRECT SELECT & DIGITAL DISPLAY ENTRANCE STATIS Loop Wiring Method Max. of 25 stations per loop / trunk WIRE TYPE Homerun Wiring Method 872002 20AWG 2 Cond. Solid Non Shielded PE Insulated 871802 18AWG 2 Cond. Solid Non Shielded PE Insulated POWER 20UL Power Transformer (Use proper power for the Strike or Mag Lock being used). *DP GTBC *Distribution Point: Aiphone. This can be or commons the / connection. (Terminal strip, punch down block, wire nuts, etc.) Tenant stations shown are the GT1A. The GT1D tenant stations can also be used and wire in the same manner. Door Strike ELM ELC ELB Mag Lock ELM ELC ELB CN3 00 2 GT Series QuikStart Guide

SYSTEM WIRG: AUDIO / VIDEO ALLE & DIGITAL ENTRANCE STATIS Loop Wiring Method Max. of 25 stations per loop. switch must be set to A on last monitor in the wire loop. Homerun Wiring Method Max. of 6 GT4Zs per loop. switch must be set to A on last GT4Z in the wire loop. Each tenant station homeruns to a GT4Z and its switch must be set to A. B1 B1 B1 B1 B1 B1 B1 B1 B1 (3) A B LE (4) (1) (2) B1 B1 B1 GT4Z B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 (3) A B LE (4) (1) (2) B1 B1 B1 GT4Z B1 B1 *DP B1 B1 B1 B1 B1 B1 GTBC GTVBC *Distribution Point: Aiphone. This can be or commons the / connection. (Terminal strip, punch down block, wire nuts, etc.) Tenant stations shown are the GT1C. The GT2C or GT1ML tenant stations can also be used and wire in the same manner. Note: GT2C requires a separate 20UL Door Strike ELM ELC ELB Mag Lock ELM ELC ELB CN3 CN3 00 3

SYSTEM WIRG: EXPANDED SYSTEM GTVA GTDA #1 #2 #3 #4 #5 #6 #7 GTMK #2 GTMK #1 *DP Connection for video entrance { GTBC Connection { for audio entrance COMM 1 COMM 2 USB GTVBX COMM 1 COMM 2 GTWLC SUB 1 SUB 2 SUB 1A SUB 1B SUB 2A SUB 2B GTBCX B1 B1 B1 B1 GTBC GTVBC B1 B1 B1 B1 B1 EXP STD B1 *DP Video outputs to tenant stations and / or GT4Z units. Max. of 25 tenants per trunk and 125 total tenants per GTVBC. Audio output to tenant stations and / or GT4Z units. Max. of 25 tenants per trunk and 125 total tenants per GTBC. *Distribution Point: that parallels or commons the / connection. (Terminal strip, punch down block, wire nuts, etc.) OI CNECTOR: TENANT STATIS GT2C 12pin option connector K (Brown) Emergency alarm KE (Red) RY (Blue) Ext. Signaling (GTRY) RY (White) SW (Gray) Option contact output SW (Black) S1 (Orange) Security/Utility input 1 S1E (Black) S2 (Yellow) Security/Utility input 2 S2E (Black) S3 (Purple) Security/Utility input 3 S3E (Black) 4pin option connector (not included) V (Brown) V (Red) (Orange) (Yellow) Video out Display transfer GT1C Option connector DC (Yellow) DC (Orange) RY (Blue) RY (White) SW (Gray) SW (Black) Doctor call (Automatic entry) External Signaling (GTRY) Option contact output GT1A Option connector DC (Yellow) DC (Orange) RY (Blue) RY (White) SW (Gray) SW (Black) Doctor call (Automatic entry) External Signaling (GTRY) Option contact output are shown here. For information on other tenant station option refer to pages 3031 of the GT Series Installation Manual. 4 GT Series QuikStart Guide

DIP SWITCH SETTGS: ENTRANCE STATI (REQUIRED) Entrance ID Setting: Use SW2 on the GTDAL module or GTDAL GTDM #1 #2 #3 #4 #5 #6 #7 DIP SWITCH SETTGS: ENTRANCE STATI (OIAL) NOTE: Guidance Language Setting: The guidance is set to off (No Guidance) when shipped. Use SW3 on the GTDAL module to set the appropriate GTDAL No Guidance English French Spanish German Dutch Italian (default) Entrance Monitoring: Use switch 1 of SW2 on the GTDAL module to enable / disable entrance monitoring. Default is Monitoring not GTDAL 1 Monitoring possible Monitoring not possible Room Number Display: Use switch 2 of GTNS 2 Message Setting: Use switch 3 of Default is Greeting Message. GTNS Operation Message Greeting Message 3 Camera View: on the GTVA module to set the camera view. The default setting is Zoom. Zoom 3s>>Wide: Image starts zoomed and after 3 seconds goes wide. Wide 3s>>Zoom: Image starts wide and after 3 seconds zooms. GTVA ZOOM WIDE ZOOM 3s>>WIDE WIDE 3s>>ZOOM (default) 5

PROGRAMMG: PUT RESIDENT FORMATI NOTE: The GT digital panel, GTDM, and GTMK must be programmed with the resident information before tenant stations can Entering Resident Info Using Keypad Step 1: # plus the ID code (*1111). Reenter ID code. Step 2: Scroll to RESIDENT FO. and press Bell button. Step 3: ROOM # Bell button. Step 4: The room number entered will appear on screen along with a space for the Resident Name. Use the Keypad and Arrow Bell button Step 5: Step 6: Press X to return to main menu. Scroll to QUIT and press X again to exit programming. Entering Resident Info Using Software Step 1: Using the CD supplied with the GTBC, install the GT software and USB cable driver on a PC running Windows XP, Windows Vista, or Windows 7. Step 2: Open GT software, click GT System Mode. Step 3: Select Resident tab. Step 4: Enter a Room # and Name (if desired) for each resident. Step 5: Connect the USB cable to the PC and to the GT device being programmed. Ensure that the GT device being programmed is powered. Step 6: Step 7: Select Connection COM Port from the menu bar to see the available COM Ports on the PC. Step 6. Step 8: Select Connection Export from the menu bar. (Export sends data to the entrance station. Import pulls data from the entrance station.) Step 9: A new window will open asking, Do you want to overwrite the information? Select Yes. Step 10: Enter ID code (default is * 1111) and click OK. Data will be transferred. PROGRAMMG: ADDRESSG TENANTS VIA HANDSHAKE METHOD Direct Select / Push Button Entrance Station Addressing Step 1: Remove front cover from entrance station. Step 2: To enter programming mode, use a small screwdriver to push and release button under the Step 3: At tenant station, push and release the TALK button or pick up the handset to establish communication with the entrance station in programming mode. Step 4: Push and release the desired Call Button on the entrance station to assign the button to the tenant station that is active. A blip tone will be heard. Do not press and hold the Call Button as doing so will clear the memory for this button. Step 5: Step 6: Step 7: Turn off or hang up tenant station (GT1A: Push TALK again, GT1C / GT2C: Push OFF). Repeat steps 35 for remaining tenant stations. To exit programming, push the button under the rubber cap on the GTDAL module again 6 GT Series QuikStart Guide

PROGRAMMG: ADDRESSG TENANTS VIA HANDSHAKE METHOD (continued) GT Digital Display Entrance Station Addressing Step 1: Remove front cover from entrance station. Step 2: To enter programming, use a small screwdriver to push and release button under the rubber cap lit, the entrance station is in programming mode. The LCD will show CNECTG while in programming mode. Step 3: At tenant station, push and release the TALK button or pick up the handset to establish communication with the entrance station in programming mode. Step 4: Bell button to assign the address to the tenant station that is active. A blip tone will be heard. Do not press and hold the Bell button as doing so will clear the memory for this address. Step 5: Turn off or hang up tenant station (GT1A: Press TALK again, GT1C / GT2C: Press OFF). Step 6: Repeat steps 35 for remaining tenant stations. Step 7: To exit programming, push the button under the rubber cap on the GTDAL module again and the GTDM Entrance Station Addressing Step 1: # plus ID code (default is *1111). Reenter ID code. Step 2: Use the up / down arrows and scroll to PROGRAMMG. Push the Bell button to enter in programming mode. The LCD will show CNECTG while in programming mode. Step 3: At tenant station, push and release the TALK button or pick up the handset to establish communication with the entrance station in programming mode. Step 4: Bell button to assign the address to the tenant station that is active. A blip tone will be heard. Do not press and hold the Bell button as doing so will clear the memory for this address. Step 5: Turn off or hang up tenant station (GT1A: Press TALK again, GT1C / GT2C: Press OFF). Step 6: Repeat steps 35 for the remaining tenant stations. Step 7: To exit programming, press the X button on the panel to return to the main menu (the amber LED will turn off). Scroll to QUIT GTMK Concierge Station Addressing Step 1: # plus ID code (default is *1111). Reenter ID code. Step 2: Use the up / down arrows and scroll to PROGRAMMG. Press the Bell button to enter programming mode. The LCD will show CNECTG while in programming mode. Step 3: Pick up the handset on the GTMK and leave off hook. Step 4: At tenant station, push and release the TALK button or pick up the handset to establish communication with the GTMK in programming mode. Step 5: Bell button to assign the address to the tenant station that is active. A blip tone will be heard from the GTMK handset. Do not press and hold the Bell button as doing so will clear the memory for this address. Step 6: Turn off or hang up tenant station (GT1A: Press TALK again, GT1C / GT2C: Press OFF). Step 7: Repeat steps 46 for the remaining tenant stations. Step 8: To exit programming, press the X button on the GTMK to return to the main menu. Scroll to QUIT and press the X Transferring Data Between Entrance Stations The tenant / entrance station handshake information can be transferred between entrance stations and / or concierge stations. The above handshake procedure must be done at one entrance station before the transfer can occur. Refer to page 40 of the GT Series Installation Manual for this procedure. Never do a transfer from an entrance station or concierge station that has not been addressed with tenant stations. 7

PROGRAMMG: ADDRESSG TENANTS VIA DIP SWITCH METHOD Step 1: Set dip switches for all GT1C and GT2C stations using the chart example to the right. (The full GT Dip Switch Setting Worksheet can be found on the CD included with the GTBC.) Step 2: Apply power to system. Step 3: Install the GT software and USB cable driver on a computer running Windows XP, Windows Vista, or Windows 7. (Refer to page 6 for COM Port selection steps.) Step 4: Open the GT software, select [GT System Mode]. Step 5: Select the Resident tab. Step 6: Enter a Room # and Name for each tenant to be programmed. Step 7: Select View Room ID # Setting from the menu bar (see Figure 1). Figure 1 Binary Dip Switch 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 Std S1 S2 S3 S4 S5 S6 S7 Decimal ID # Exp Exp (Sub 1) (Sub 2) A3 A4 A5 A6 A7 51 52 53 54 55 56 57 5 6 7 8 S8 A8 58 Step 8: For each Binary Dip Switch setting made in Step 1, enter the appropriate ID into the Room ID # Setting field. Ensure that the correct correlation is kept between tenant name and actual unit (see Figure 2). Figure 2 Step 9: Select Connection Export from the menu bar (see Figure 3). (Export sends data to the entrance station. Import pulls data from the entrance station.) Figure 3 Room ID # Setting: Use S# for standard system stations 148. Use A# for expanded system stations 1250. Use B# for expanded system stations 251500. For tenant stations 251500, the dip switch assignment is the same as 1250. Tenant stations 1250 wire to Sub 1A and Sub 1B of the GTBCX while tenants 251500 wire to Sub 2A and Sub 2B (see page 4). Note: 8 binary digits allows for 255 unique numbers. Only numbers 1250 are used by the GT system. Step 10: Check the LinkData box and select Yes (see Figure 4). Step 11: Enter ID code (default is *1111) and click OK (see Figure 5). Data will be transferred. Figure 4 Figure 5 Visit our website for complete information and literature on the GT Series MultiTenant Entry Security System. www.aiphone.com/home 0712 #95228 8 GT Series QuikStart Guide Aiphone Corporation 1700 130th Ave. NE Bellevue, WA 98005 Ph: (800) 6920200 Fax: (425) 4550071 www.aiphone.com tech@aiphone.com