r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

Similar documents
170.IU0.TMS /D r USER MANUAL TMS

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

Instruction Manual IN February Model 7SF

170.IU0.LFS.0B /B r USER MANUAL LFS

ISOMETER IRDH575. Approvals

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

K3P ENG.qxd 23/10/ Pagina 1

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

170.IU0.XKP.0C r USER MANUAL PKP MKP

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

General Specifications

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

QUINT-PS AC/24DC/40

PMW. Serial Interface INSTRUCTION MANUAL MICROPROCESSOR BASED CONTROLLER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

7SD/7SH/7SM Temperature Controllers

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

QUINT-PS-24DC/24DC/10

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document

IF30. User's manual. Description. Table of contents IF30

QUINT-PS/ 3AC/24DC/10

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

PRetrans Table of contents

Power supply CP-T 48/20.0 Primary switch mode power supply

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

MINI MCR-SL-UI-I-LP-NC

Power supply CP-T 48/5.0 Primary switch mode power supply

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

TxBlock-USB Transmitter

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

HO118 Binning Interface User Manual * * Version 02. User Manual. Test & Measurement

High Performance Process & Temperature Controllers

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Multi-turn Actuators ET RANGE

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

MSV200 - Hall effect transducer

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

Power supply CP-E 24/2.5

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

AC/DC Current Oscilloscope Probe Model SL261

Power supply CP-E 24/20.0

JUMPFLEX 857 Series ma ma V. Signal Conditioning/Relay and Solid State Modules

4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT

User and Safety Manual ProLine P224xx P1

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

Instruction Manual (1/8 DIN) Controller With ma output.

Power supply CP-D 12/2.1

General Specifications

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

MINI-PS AC/24DC/1.3

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

Power supply CP-T 24/20.0 Primary switch mode power supply

Excellent low-cost Process & Temperature Controllers

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

SHIMADEN DIGITAL INDICATORS

Installation guide 971 SmartRadar LTi

em4 local - Robust Specific characteristics Part number

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

MODEL 3810/2 Line Impedance Stabilization Network

Simple Sturdy Economical LABEL. Invest in Confidence. Weatherproof Quarter-turn Actuators EZ RANGE

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 1AC/24DC/20

170.IU0.Q , r USER MANUAL EWTQ915 EWTQ985

MW3105 DIGITAL CLAMP MULTIMETER

Fuzzy Temperature Controllers E5AF

AC/DC Power Supply Series APPLICATION NOTE

General Specifications

SHIMADEN DIGITAL INDICATORS

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

Temperature Controllers E5 J

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

INSTRUCTION SHEET. Eaton Logic Controller ELCM TC Temperature Modules. [Applicable Temperature modules] ELCM-TC04ANNN MTN1

Analog Module D1-15P User Manual

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

3B SCIENTIFIC PHYSICS

Voltage Transient Emission Test

Power supply CP-E 24/0.75

MACX MCR-UI-UI-UP(-SP)(-NC)

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

Passive TX, 2 wires, ma 0/ mv, 0/1... 5V, 0/ V ma (active) Pt1000 Pt100 TC. 2.2 Inputs

HAWK5000 Operators Manual

MODEL: M2DYS SEN TRONIC AG

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Transcription:

170.ADD.LFS.RB0 0,8.011-98/B r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

INDEX ASSEMBLING... 1 Warning... 1 General assembling information... 1 Wall mounting... 1 Omega din rail mounting... 2 MECHANICAL DIMENSIONS... 3 CONNECTION DIAGRAMS... 4 Measuring inputs... 4 Outputs... 7 Serial interface... 9 Power line wiring... 10

ASSEMBLING WARNING: 1) The correct functionality of these instruments is guaranteed only if transport, storage, installation, wiring, working condition and maintenance are executed in compliance with this manual. 2) The protection degree of these instruments is equal to IP 20 (according to IEC529) and they are connected to dangerous power lines, for these reasons: - installation, wiring and maintenance must be executed by qualified personnel; - all warnings contained in this manual must be complied. 3) The safety requirements for Permanently Connected Equipment say: - a switch or circuit-breaker shall be included in the building installation; - It shall be in close proximity to the equipment and easy to reach for the operator; - it shall be marked as the disconnecting device for the equipment. NOTE: a single switch or circuit-breaker can drive more than one instrument. 4) Before to execute any operation on the connections, disconnect the instrument from the power line by the circuit breaker. GENERAL ASSEMBLING INFORMATION Select a cleaned location, easy to reach, where minimum vibrations are present and the ambient temperature is within 0 and 50 C (32 and 122 F). These instruments can be mounted either on wall or on OMEGA DIN rail. For mechanical dimensions refer to Fig. 4. WALL MOUNTING For wall mounting, use the (A) holes. In this case it is advisable to use four M4 screws with a torque of 1Nm. For mounting template and mechanical dimensions, please refer to Fig. 4 drawing. (A) (A) (A) (A) Fig. 1 1

OMEGA DIN RAIL MOUNTING For rail mounting use an OMEGA DIN rail in accordance with EN 50 022 (35 x7.5 mm or 35 x 15 mm) regulations. Screwdriver Fig. 2 MOUNTING Fig. 3 REMOVING 2

MECHANICAL DIMENSIONS Fig. 4 MECHANICAL DIMENSIONS 3

CONNECTION DIAGRAMS Connections have to be executed when the instrument is placed in its proper location. MEASURING INPUTS NOTES: 1) Any external components (like zener barriers etc.) connected between sensor and input terminals may cause measurement errors due to excessive and/or not balanced line resistance or possible leakage currents. 2) The input accuracy is equal to + 0.2 % f.s.v. (**) + 1 dgt. @ 25 C of ambient temperature. (**) For TC input, the f.s.v. should be referred to the higher f.s.v. of the TC selected. TC INPUT TC type R and S Fig 5.A LFS-RELAY TERMINAL BLOCK + 15 14 + 15 Shield 14 Shield Fig. 5.B LFS-mA TERMINAL BLOCK Fig. 6.A INPUT WIRING FOR TC TYPE R AND S 4

TC type J, K, L, N and T + 15 RTD INPUT RTD RTD 11 + 15 Shield 11 16 15 14 16 15 14 Shield Fig. 6.B INPUT WIRING FOR TC TYPE J, K, L, N AND T NOTE: 1) Do not run input wires with power cables. 2) For TC wiring use proper compensating cable preferable shielded. 3) when a shielded cable is used, it should be connected to one side only. Fig. 7 RTD INPUT WIRING NOTE: 1) Don t run input wires together with power cables. 2) Pay attention to the line resistance; an high line resistance may cause measurement errors. 3) When shielded cable is used, it should be grounded at one side only to avoid ground loop currents. 4) The resistance of the 3 wires must be the same. 5

LINEAR INPUT 15 14 15 14 + ma, mv or V Shield + G ma mv or V LOGIC INPUT NOTES: 1) Do not run logic input wiring together with power cables. 2) Use an external dry contact capable of switching 0.5 ma, 5 V DC. 3) The instrument needs 100 ms to recognize a contact status variation. 4) The logic input is NOT isolated by the measuring input. 5) This feature excludes the current transformer input function. 12 IN CT/SP-SP2 (for LFS-relay) SP-SP2 (for LFS-mA) Fig. 8 ma, mv AND V INPUTS WIRING NOTE: 1) Do not run input wires together with power cables. 2) Pay attention to the line resistance; a high line resistance may cause measurement errors. 3) When shielded cable is used, it should be grounded at one side only to avoid ground loop currents. 4) The input impedance is equal to: < 5 Ω for 20 ma input > 1 MΩ for 60 mv input > 200 kω for 5 V input > 400 kω for 10 V input 13 Fig. 9- LOGIC INPUT WIRING This input (connections 12 and 13) is used either a current transformer input (for LFS-relay only) or a logic input. When the logic input is selected, it is used to switch, by an external contact, from main set point to second set point and viceversa. logic input op. set point open SP close SP2 6

CURRENT TRANSFORMER INPUT (For LFS-relay only) Safety note: 1) Do not run current transformer input wiring together with AC power cables. 2) This feature excludes the logic input function. 3) The input impedance is equal to 10 Ω. OUTPUTS LINEAR OUTPUT (For LFS-mA only) This instrument is equipped with one linear output (OUT 1) programmable as: - main output (heating or cooling) - secondary output (cooling) - analog retransmission of the measured value - analog retransmission of the operative set point. 12 13 Current transformer OUT 1 7 8 + + 20 ma Load Fig. 10 - CURRENT TRANSFORMER INPUT WIRING Fig. 11 ma OUTPUT 1 WIRING NOTE: It is an isolated analog output. Maximum load: 500 Ω. This input allows to measure and display the current running in the load driven by the OUTPUT1 during the ON and OFF period of the OUT 1 cycle time. By this feature it is also available the "OUT 1 failure detection" function. 7

RELAY OUTPUTS OUT 1 (for LFS-relay only) OUT 2 (AL1) OUT 3 (AL 2) Fig. 12 RELAY OUTPUTS WIRING The contact rating of OUT 1 is 3A/250V AC on resistive load. The contact rating of OUT 2 and 3 is 2A/250V AC on resistive load. The number of operations is 1 x 10 5 at specified rating. NOTES 1) To avoid electric shock, connect power line at the end of the wiring procedure. 2) For power connections use No 16 AWG or larger wires rated for at last 75 C. 3) Use copper conductors only. 4) Do not run input wires with power cables. All relay contacts are protected by varistor against inductive load with inductive component up to 0.5 A. The following are recommendations avoid serious problems which may occur, when using relay output for driving inductive loads. 7 8 1 2 3 C NO NO - OUT 2 C - OUT 2/3 NO - OUT 3 INDUCTIVE LOADS High voltage transients may occur switching inductive loads. Through the internal contacts these transients may introduce disturbances which can affect the instrument performances. For all outputs, the internal protection (varistor) assures a correct protection up to 0.5 A of inductive component. The same problems may occur when a switch is used in series with the internal contacts as shown in Fig. 13. Fig. 13 EXTERNAL SWITCH IN SERIES WITH THE INTERNAL CONTACT In this case it is recommended to install an additional RC network across the external contact as show in Fig. 13. The value of capacitor (C) and resistor (R) are shown in the following table. LOAD (ma) <40 ma <150 ma <0.5 A C (µf) 0.047 0.1 0.33 C LOAD R (Ω) 100 22 47 P. (W) 1/2 2 2 OPERATING VOLTAGE 260 V AC 260 V AC 260 V AC Anyway the cable involved in relay output wiring must be as far away as possible from input or communication cables. R LINE 8

VOLTAGE OUTPUTS FOR SSR DRIVE (For LFS-relay only) OUT 1 7 8 Fig. 14 SSR DRIVE OUTPUT WIRING It is a time proportioning output. Logic level 0: Vout < 0.5 V DC. Logic level 1: - 14 V + 20 % @ 20 ma - 24 V + 20 % @ 1 ma. Maximum current = 20 ma. + + SOLID STATE RELAY NOTE: This output is not isolated. A double or reinforced isolation between instrument output and power supply must be assured by the external solid state relay. SERIAL INTERFACE RS-485 interface allows to connect up to 30 devices with one remote master unit. I N S T R U M E N T 4 5 6 A/A' B/B' Fig. 15 - RS-485 WIRING COMMON A'/A B'/B M A S T E R The cable length must not exceed 1.5 km at 9600 BAUD. NOTES: 1) This is an isolated RS 485 serial interface. 2)The following report describes the signal sense of the voltage appearing across the interconnection cable as defined by EIA for RS-485. a) The A terminal of the generator shall be negative with respect to the B terminal for a binary 1 (MARK or OFF) state. b) The A terminal of the generator shall be positive with respect to the B terminal for a binary 0 (SPACE or ON). 9

POWER LINE WIRING 9 10 N (L2) POWER LINE 100 V to 240 V A.C (50/60Hz) or 24 V AC/DC P (L1) P (L1) N (L2) equipment and within easy reach of the operator; - it shall be marked as the disconnecting device for the equipment. NOTE: a single switch or circuit-breaker can drive more than one instrument. 9) When neutral line is present, connect it to terminal 9 Fig. 16 POWER LINE WIRING NOTES: 1) Before connecting the instrument to the power line, make sure that line voltage corresponds to the description on the identification label. 2) To avoid electric shock, connect power line at the end of the wiring procedure. 3) For supply connections use No 16 AWG or larger wires rated for at last 75 C. 4) Use copper conductors only. 5) Do not run input wires with power cables. 6) For 24 V DC the polarity is not a care condition. 7) The power supply input is NOT fuse protected. Please, provide it externally. Power supply Type Current Voltage 24 V AC/DC T 500 ma 250 V 100/240 V AC T 125 ma 250 V When fuse is damaged, it is advisable to verify the power supply circuit, so that it is necessary to send the instrument back to your supplier. 8) The safety requirements for Permanently Connected Equipment say: - a switch or circuit-breaker shall be included in the building installation; - It shall be in close proximity to the 10

Ero Electronic S.r.l. Via E. Mattei, 21 28100 Novara Italy Tel. +39 0321481111 Fax +39 0321481112 eroelectronic@ero.eurotherm.co.uk BENELUX ERO Electronic Benelux SA/NV Rue Val Notre Dame 384 MOHA 4520 (WANZE) Tel. 085-274080 Fax 085-274081 ero.electronic@skynet.be BRASIL ERO ELECTRONIC DO BRASIL Industria e Comercio Ltda. Rua Garibaldi, 659 - Conj. 202 90035-050 PORTO ALEGRE Tel. 051-2214888 Fax 051-2214734 erobr@nutecnet.com.br CHINA TIANJIN VEGA COMPANY Ltd (TAIF) Hebei District 300232 TIANJIN Tel. 022-26273296 Fax 022-26273297 FRANCE ERO Electronic SARL Zac du Chêne 34, Rue du 35éme Régiment d Aviation 69673 BRON CEDEX Tel. 0478267979 Fax 0478267800 GERMANY ERO Electronic GmbH Ottostrasse 1 65549 LIMBURG A.D. LAHN Tel. 06431-95680 Fax 06431-57493 NETHERLAND ERO Electronic Nederland Ganieelan 4 2404 CH Alphen a/d Rijn Tel. 0172-420400 Fax. 0172-420395 sales@eroelectronic.nl SOUTH AFRICA ERO Electronic S.A. Pty Ltd Airgro House 1343, Spokeshave Avenue Stormill Ext 2 ROODEPOORT Tel. 011-4742278/9 Fax 011-4749404 P.O. Box 43112 Industria 2042 ero-sa@kingsley.co.za SPAIN ERO ELECTRONIC IBERICA Calle La granja, 74 Pol. Ind. Alcobendas MADRID Tel. 091-6618194 Fax. 091-6619093 U.K. ERO U.K. Unit 1, Cygnet Trading Estate Faraday Close Durrington, Worthing WEST SUSSEX BN13 3RQ Tel. 01903-693322 Fax. 01903-693377 U.S.A. AMERICAN ERO Electronic Corp BARRINGTON, ILL. 60010 Tel. 0847-382-0881 Fax 0847-382-0240 U.S.A. BARBER COLMAN Industrial Instruments Div. P.O. BOX 2940 Loves Park, IL - 31132-2940 Tel. 0815-637-3000 Fax 0815-637-5341 jgsearle@ad.com