Evaluation of the Partial Compressive Strength according to the Wood Grain Direction* 1

Similar documents
Comparisons of bearing properties for various oriented glulam using digital image correlation

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Development of Wooden Portal Frame Structures with Improved Columns

Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Dowel connections in laminated strand lumber

Title. CitationJournal of Wood Science, 58(4): Issue Date Doc URL. Rights. Type. File Information.

Combined stress analysis of mitered spline furniture joints under diagonal loading

Development of wooden-based nails for wooden pallet

PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD

EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS. G. Y. Jeong* J. H. Kong

PRO LIGNO Vol. 11 N pp

Deterioration of Dowel Bearing Properties of Timber Due to Fungal Attacks

Prediction of Reinforcement Effect by Screw on Triangular Embedment Perpendicular to the Grain with Variation of Screw Locations

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite.

Design of Bolted Connections per the 2015 NDS

Effect of shoulders on bending moment capacity of round mortise and tenon joints

Three-dimensional finite element analysis of the Japanese traditional post-and-beam connection

Section Downloads. Lumber Design Values. Lumber Standard. Western Lumber Product Use Manual. Section 05: Truss Materials.

WOODEN BUILDINGS 6.1 INTRODUCTION 6.2 TYPICAL DAMAGE AND FAILURE OF WOODEN BUILDINGS. Chapter 6

Effects of tightening speed on torque coefficient in lag screw timber joints with steel side plates

Engineering Research into Traditional Timber Joints

THREE-DIMENSIONAL NONLINEAR FINITE ELEMENT MODEL FOR SINGLE AND MULTIPLE DOWEL-TYPE WOOD CONNECTIONS

Glued laminated timber beams repair.

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

STRUCTURAL TIMBER DESIGN

Design Nailed and Wood Screwed Connections with Spreadsheet. Course Content

Effect of Vertical Load under Cyclic Lateral Load Test for Evaluating Sugi CLT Wall Panel

Shear Capacity of Dowelled Mortise and Tenon in Tropical Timber

Dowel type joints Influence of moisture changes and dowel surface smoothness. Erik Serrano and Johan Sjödin, Växjö University, Sweden

Exam Sheet, Part 1. hardwood softwood. pith, heartwood, sapwood, vascular cambium, phloem, outer bark. sapwood, phloem, vascular cambium, outer bark.

Lawrence A. Soltis. James K. Little

Comparison of behaviour of laterally loaded round and squared timber bolted joints

Static Front to Back Loading Capacity of Wood Chairs and Relationship between Chair Strength and Individual Joint Strength

A PREDICTIVE MODEL FOR THE CUTTING FORCE IN WOOD MACHINING DEVELOPED USING MECHANICAL PROPERTIES

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber

Anti-check bolts as means of repair for damaged split ring connections

Connection Design Examples

AN IMPROVED SHEAR TEST FIXTURE USING THE IOSIPESCU SPECIMEN

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES

Simplified analysis of timber rivet connections

Timber Rivet Connections Design Process for a Hanger Connection

4-Bolt Wood-to-Steel Connections

Double Shear Testing of Bolts

THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH

ABSTRACT INTRODUCTION

Screw Withdrawal A Means to Evaluate Densities of In-situ Wood Members

Mechanical behavior of fiberglass reinforced timber joints

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

DESIGN CONSIDERATIONS FOR MORTISE AND TENON CONNECTIONS

A novel procedure for evaluating the rotational stiffness of traditional timber joints in Taiwan

Wood. Wood construction

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

NON-LINEAR CONNECTION MODELS IN TIMBER ENGINEERING

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES

Lateral Load-Bearing Capacity of Nailed Joints Based on the Yield Theory

Connection and performance of two-way CLT plates

Glulam Curved Members. Glulam Design. General Glulam Design. General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams

Connection Solutions for Wood-frame Structures. Copyright Materials. Learning Objectives

EVALUATION OF THE STRUCTURAL BEHAVIOUR OF BEAM-BEAM CONNECTION SYSTEMS USING COMPRESSED WOOD DOWELS AND PLATES

Exploratory study of high-strength, low-cost through-bolt with cross-pipe and nut connections for square and roundwood timber frame construction

Joint analysis in wood trusses

LAPPING FOR MIRROR-LIKE FINISH ON CYLINDRICAL INNER AND END SURFACES USING THE LATHE WITH LINEAR MOTOR

TFEC Standard for Design of Timber Frame Structures and Commentary

The Wood Products Council is a Registered Provider with. . Credit(s) earned on completion of this program will be

APA Performance Rated Rim Boards

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C)

Defect detection in lumber including knots using bending deflection curve: comparison between experimental analysis and finite element modeling

LOAD DURATION AND SEASONING EFFECTS ON MORTISE AND TENON JOINTS

Improved Arcan Shear Test For Wood

National Design Specification for Wood Construction. Copyright Materials. Learning Objectives

Ultrasonic Transmission Characteristics of Continuous Casting Slab for Medium Carbon Steel

SIMPLIFIED DESIGN PROCEDURE FOR GLUED-LAMINATED BRIDGE DECKS

Withdrawal Strength of Staples

Statistical Lower Tolerance Limits for Rectangular Mortise and Tenon Joints

Space-frame connection for small-diameter round timber

Derivation of Mechanical Properties of Rubberwood Laminated Veneer Lumber

Timber Bridge Hardwood Glulam Deck Connector Evaluations under Static and Repetitive Loads

ADDENDUM (February 2014) 2012 NDS Changes John Buddy Showalter, P.E., Bradford K. Douglas, P.E., Philip Line, P.E., and Peter Mazikins, P.Eng.

PRACTICAL ENGINEERING. Strong Rail-Post Connections for Wooden Decks

Ingenious hardwood. Ingenious hardwood. Order our BauBuche sample box free of charge. 1

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

Standard Test Methods of Static Tests of Wood Poles 1

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

Load-carrying capacity of timber frame diaphragms with unidirectional support

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Standard Test Methods for Small Clear Specimens of Timber 1

Hardness distribution on wood surface

Analysis and Testing of a Ready-to-Assemble Wood Framing System

THE ENGINEERED WOOD ASSOCIATION

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

Development of a joint system using a compressed wooden fastener I: evaluation of pull-out and rotation performance for a column sill joint

Design of structural connections for precast concrete buildings

Transcription:

J. Korean Wood Sci. & Tech. 41(2) : 100~104, 2013 http://dx.doi.org/doi : 10.5658/WOOD.2013.41.2.100 Evaluation of the Partial Compressive Strength according to the Wood Grain Direction* 1 Chun-Young Park* 2, Hyung-Kun Kim* 3, Jun-Jae Lee* 3 and Gwang-Chul Kim* 2 ABSTRACT Bearing occurs by the rotations of members induced from horizontal or vertical load at traditional wooden joint in frame. The bearing between wooden members is not occurring at the whole surface of joint, but occurring only at the particular bearing area. In this study, partial bearing according to the different grain direction was evaluated. The partial compressive strength showed 3 times higher than pure compressive strength perpendicular to grain, 1.5 times higher than parallel to grain and 3.3 times higher than both of them. It is expected that this result can be very importantly applied when evaluating and analyzing the actual behavior of traditional wooden mortise and tenon joint. Keywords : embedment, partial compressive strength, mortise and tenon joint, wood grain 1. INTRODUCTION Bearing behavior to wood members occurs at inner part of the connection and does in between post and beam member of the connection when it is subjected to horizontal or vertical load, which is the formal characteristic of the connection of Korean traditional post-beam structure. In the past, researchers applied compressive strength of wood according to wood direction and Hankins equation for the structural analysis of mortise and tenon joint. However it is apt to face two problems as considering behavior of the real connection; 1) bearing of wood is not the result of the whole compression but the result of partial compression, 2) not easy to apply Hankins equation because the contact area changes with the rotational angle although surface which subjected to compression have angle to the grain, Partial compression means the bearing subjected not to the whole surface but part of the surface. In this case, the shear behavior occurs at the boundary between two members and the compression to the grain act on the contact area at the same time. It leads to higher strength than the previous whole compression strength (Fig. 1). * 1 Received on November 2, 2012; accepted on March 7, 2013 * 2 Department of Housing Environmental Design, Chonbuk National University, Jeonju 561-756, Korea * 3 Department of Forest Sciences, Seoul National University, Seoul 151-742, Korea Corresponding author : Gwang-Chul Kim (e-mail: gckim@jbnu.ac.kr) - 100 -

Evaluation of the Partial Compressive Strength according to the Wood Grain Direction Fig. 1. Outline of the partial compression. In addition, the area can be expressed as the function of the rotational angle because the surface area changes according to the change of the rotational angle. And theoretically only plastic area exists as soon as bearing started on the basis of material mechanics. Kim (2011) conducted compressive test with structural sized lumber and reported that skin timber with even 25% of cross section area showed almost 50% compressive performance of solid timber. This means that the resistance is not exactly proportional to the area and it would have greater effect on timber because it is nonhomogeneous material. Kang et al. (2001) made a research on compressive behavior by separating early wood and late wood of Japanese Sugi and concluded that early wood has one fourth of maximum strength and MOE compare to late wood. In particular, late wood shows short elastic range and long plastic range while early wood shows linear deformation behavior. That is, the behavior differs from the bearing of early and late wood in traditional joint and proves that the effect of early and late wood should be considered. Jang (2000) reported that compressive strength is proportional to velocity of ultrasonic wave according to the angle of wood grain. It means that the performance of the joint with mortise and tenon is more complicated because of the cross of wood grains of wood members. Generally, compressive deformation induces shear stress between close cells and separates middle lamella or parenchyma cell. And it is occurred by the tiny kink which means local deformation of micro-fibril structures after the separation of the outer and middle lamella of the tracheid. Bearing of wood regarding the behavior of traditional connection occurs in joint, under joint and upper horizontal member of connection. But the type of bearing is different from compression behavior typically used. It shows partial bearing behavior accompanied with shear one. Not only the bearing of wood, but also the shape of every part of member would change. In this study, compressive strength of the partial bearing will be evaluated according to the wood grain. 2. MATERIALS AND METHODS 2.1. Materials Domestic Larch (Larix kaempferi) was used and moisture contents (M.C.) was 12.8% (standard deviation : 0.5). Average specific gravity was 0.53 (standard deviation, 0.08). Specimens were manufactured with the compressive surface of 20 20 (mm), the replication of test was ten. To reduce the variation within materials, specimens were selected from 6 different material groups. Compressive length was controlled to 70 mm. Specimen were manufactured to have different grain direction and compressive surface as shown in Fig. 2 (Perpendicular to the grain, Parallel to the grain and both of them). To compare the result, pure compressive specimen was made with the parallel to the grain. After the test, M.C. and specific gravity of each specimen were measured. - 101 -

Chun-Young Park, Hyung-Kun Kim, Jun-Jae Lee, and Gwang-Chul Kim Fig. 3 Compressive strength was divided into parallel and perpendicular to grain. In case of partial compression, the location of loading block was divided into tangential(t), parallel(p) and both of them to the grain on contact area as shown in Fig. 2 To secure the accuracy of experiment, compressive specimens used for comparison were taken from the same member. Fig. 2. Schematic diagram of specimen, angle of grain and location of loading block. 3. RESULTS AND DISCUSSION 3.1. Evaluation of Compression Strength Fig. 3. Photograph of compressive test. 2.2. Methods In order to evaluate partial compression of wood, tests were conducted in accordance with KS F 2206 which defines wood compression test. Length of the specimen was 70 mm and loading speed was set up at 0.3 mm/min with universal test machine (Zwick, 100 kn). And loading block was manufactured parallel to grain using same species to achieve the objective of this study which aimed to evaluate the performance of wood to wood connection. Specimens were prepared in different type as shown in Fig. 2 considering the characteristic of surface which the wood grain was broken by the loading block. Test for compression strength was conducted as shown in Compressive strength of wood has significant difference according to the grain of angle. Tests to evaluate compressive strength were coducted in two directions, parallel and perpendicular to the grain. Compressive strength showed devition between material groups. The result showed that compressive strength perpendicular to the grain was 1/13 compared to that of parallel to the grain, and the value was 4.3 MPa on average. As compressive behavior of traditional connection occur perpendicular to the grain of horizontal and vertical members, partial compressive strength was evaluated based on compressive strength of perpendicular to the grain. Test results were shown in Table 1. 3.2. Evaluation of Partial Compressive Strength with Two Shear Surfaces Evaluation of partial compressive strength was conducted as shown in Fig. 4. Failure mode was shown in right side of the Fig. 4. And that failure occurred by both the bearing which acts perpendicular to the grain and the wrecking failure of edge. The result shows increase of strength compared to the whole compressive strength and different value according to the direction of loading block. As shown in the Table 2, the strength when the - 102 -

Evaluation of the Partial Compressive Strength according to the Wood Grain Direction Table 1. Compressive strength of pure compressive specimen Load direction qe Compressive strength (MPa) Average (MPa) Strength ratio Parallel to grain Group F 46.96 Group E 64.87 55.41 12.79 Group A 2.97 Perpendicular to grain Group B 4.66 Group C 5.08 4.33 1 Group D 4.62 Table 2. Partial compressive strength Materials Load direction Compressive strength (MPa) Strength ratio Group A Perpendicular 2.97 1 Partial (Perpendicular, T) 8.94 3.01 Group B Perpendicular 4.66 1 Partial (Perpendicular, T) 12.91 2.77 2.89 Group C Perpendicular 5.08 1 Partial (Parallel, P) 7.32 1.44 Group D Perpendicular 4.62 1 Partial (Parallel, P) 6.90 1.49 1.46 Fig. 4. Photograph of partial compressive test. loading block was located in the direction perpendicular to the grain has increased about 3 times compared to the whole compressive test and about 1.5 times when the block located parallel to the grain. The difference of strength ratio is caused by the location of the boundary between two members. In the partial compression perpendicular to grain on the contact area, the fibers cross the boundary and break off by the loading block so the strength increased. In parallel to grain, the fibers were divided and split perpendicular to fiber. From the result, the direction and the number of the boundary should be considered in the structural analysis of wood to wood joints such as the mortise and tenon joint. In structural design of post and beam structure, the design value of compressive strength was utilized and the results generally did not consider. 3.3 Evaluation of Partial Compressive Strength with Four Shear Surfaces Based on the test shown above, compressive test of specimen which had 4 interfaces was conducted. In these cases, breaking off and splitting of the wood fibers occur at the same time. Failure modes are shown in Fig. 5. As much as 3.5 times higher strength com- - 103 -

Chun-Young Park, Hyung-Kun Kim, Jun-Jae Lee, and Gwang-Chul Kim Fig. 5. Photograph of partial compressive strength test. Table 3. Partial compressive strength Materials Group A Load direction Compressive strength (MPa) Strength ratio Perpendicular 2.97 1 Partial (Perpendicular, H) 9.76 3.29 Predicted result 10.40 3.5 pared to the whole compression test was expected from the previous results and the actual strength was similar (Table 3). the splitting between wood fibers is less effective on the other hand, the breaking off the fiber is more effective. CONCLUSIONS In design and analysis of wood to wood joint, the compressive strength of the whole area has been utilized to evaluate and predict the behavior and design values of the joint. However compressive strength was different according to the direction and location of the boundary between wood members which were manufactured wood to wood joints. In this study, the results show about 3 times increase in strength when the boundary was perpendicular to the grain on compressive surface, 1.5 times when it was parallel to grain and 3.3 times when it had both of them. The results should be considered in the design and analysis of wood to wood to joint especially, traditional wood joint with mortise and tenon so it would increase the accuracy of calculation. ACKNOWLEDGMENTS REFERENCES 1. Ali Awaludin, Watanachai Smittakorn, Takuro Hirai, Toshiro Hayashikawa. 2007. Vearing properties of Shorea Obtusa beneath a laterally loaded bolt, J. wood Sci. 53: 204 216. 2. Chun Won Kang, Tsutsurni Juichi, Sang Sik Jang. 2001. Mechanical Behaviour of Earlywood and Latewood under Longitudinal Compression Load, J. Korean wood science and technology 29(2): 76 83. 3. Gwang Chul Kim. 2011. A Study on the Compressive Capacity of Yellow Poplar Skintimber, J. Korean wood science and technology. 39(4): 333 343. 4. Kei Sawata, Motoi. 2002. Determination of embedding strength of wood for dowel-type fasteners, J. wood Sci. 48: 138 146. 5. Kweonhwan Hwang, Kohei Komatsu. 2002. Bearing properties of engineered wood products Ⅰ: Effects of dowel diameter and loading direction, J. wood Sci. 48: 295 301. 6. Sang Sik Jang. 2000. Effects of Moisture content and Slope of Grain on Ultrasonic Transmission Speed of wood, J. Korean wood science and technology 28(2): 10 18. This paper was supported by research funds of Chonbuk National University in 2012. - 104 -