System overview. *Safety PLC according to IEC 61508:1998 and EN ISO 13849:2006. Logic Motion Controller C-based

Similar documents
PacDrive 3 Lexium LXM 62 Modular Servo Drive System. Product Data

This document provided by Barr-Thorp Electric Co., Inc

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Lexium integrated drives

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

8V General information. 2 Order data 8V

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

Integrated servo motor

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

8V General information. 2 Order data 8V

TETRA COMPACT - E AND FLEXI - PRO

Modicon Quantum 140 NRP /01 Fiber Converter Modules User Guide

Servo motors EMME-AS. Festo core product range Covers 80% of your automation tasks

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Drive Safety integrated AC servo amplifier <MR-J3- S 0.1kW to 55kW> Safety logic unit <MR-J3-D05>

Absolute encoders - SSI

56 mm sq. (2.20 inch sq.)

Zelio Control Measurement Relays

60 mm sq. (2.36 inch sq.)

servo ARS2000 openconcepts

IP65 Splash and Dust Proof Stepping Motors

Servo motors EMME-AS. Festo core product range Covers 80% of your automation tasks

Encoder - Absolut 2RMHF-SSI

Rotary Measurement Technology Incremental Encoders

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

AMKASMART ihxt. Decentralized drive technology with clever cabling.

847H. Description. Features. Specifications

Online data sheet DFS60B-S4PA00S74 DFS60 INCREMENTAL ENCODERS

Absolute Rotary Encoder

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

EN 50178, IEC

TETRA COMPACT - E AND FLEXI - PRO THE ENHANCED SERVO BUNDLE

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Online data sheet DFS60A-TEPZ00S09 DFS60 INCREMENTAL ENCODERS

Compact drives IndraDrive Cs

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Rotary Measurement Technology Absolute Encoders, Multiturn

em4 em4 alert em4 alert 2G

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

Servomotors Order Catalogue. LSN - Servomotors with stall torque 0.26 to 60 Nm

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

em4 local - Robust Specific characteristics Part number

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

Custom "Compact" range with display CD20 Custom Part number

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Switching Power Supply Type SPP1 60W Enclosed type

SKS B2 140 GD 69/12 U - MA PB

Motion control Lexium 15. Catalogue May

Online data sheet AFS60E-S1AA AFS/AFM60 SSI ABSOLUTE ENCODERS

MCM synchronous servo motors

This Chapter contains:

ESR. The Dynamic Solution. Main Characteristics. Applications. ESR Pollmeier GmbH

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.

SKS B2 120 GDD 69/11 - A11 MA PB

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Servo Positioning Controller ARS 2300 FS

02/11/2015

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

BLuAC5 Brushless Universal Servo Amplifier

PKS-PRO-AEA-EC-08-JP22

Motion control Lexium 23 Plus

Thermistor motor protection relays

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

PKS-PRO-AEA-EC-02-JP22

Online data sheet. ACM60B-S1KE13x06 ACM60 ABSOLUTE ENCODERS

LXM23D and BCH Servo drive system Product manual V2.00,

Power connections, minimum and maximum wiring capabilities, tightening torque

maxon document number:

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

VW3A4553 line/motor choke - 2 mh - 16 A - 3 phases - 75 W - for variable speed drive

MH3. Servo motor Motor manual V1.00, , V1.00,

SKS SL 80 GD 50/10 - E4 P1

PKS-PRO-AEA-EC-30-GP22

Rotary Position Technology Incremental Encoders

SKS B2 140 GDD 69/12 U A11 MA PB

Material: Weight: Shaft Loads:

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

14 mm sq inch sq.

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Emotron FDU 2.0 Variable Speed Drive

PKS-PRO-AEA-EC-20-GP22

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

02/11/2015

Catalogue. Stepper motor drives SD3 15, D9

ABSOLUTE ROTARY ENCODER SSI

PAM & SAM System User s Manual

AC SERVO DRIVES SERIES. Servopacks. Certified for ISO9001 and ISO14001

FC Series Signal Conditioners

Transcription:

Legal notice The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components. When devices are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this information can result in injury or equipment damage. 2010 Schneider Electric. All rights reserved. Page 2 Lexium LXM62 ELAU GmbH

1 1 System overview SoMachine Motion Ethernet, TCP/IP, OPC, FTP, HTTP, SMS, SMTP LMC 100C, 200C, 300C, 400C, 600C, 800C Logic Motion Controllers Safety PLC* Magelis HMI IT/COM Logic Motion SERCOS III + Integrated Safety* Other field busses: Profibus DP CAN Ethernet/IP Profinet Multiaxes Servo Drives LXM 62 + Power Supply PSD Dxx Stand-alone ServoDrives LXM 52 TM5 I/O Distribution Box ILx Stand-alone-Drive TM7 Remote I/O TM7 Remote I/O AM BSH + BMH AM BSH + BMH Torque Motor Linear Motor ILM 62 Figure 1-1: PacDrive III System overview *Safety PLC according to IEC 61508:1998 and EN ISO 13849:2006 Logic Motion Controller C-based The LMC (Logic Motion Controller), with a VxWorks real-time operating system, cen trally implements the PLC and motion functions. A LMC synchronizes, coordinates and creates the motion functions of a food- and packaging machine for maximum: 8 Sercos III drives (LMC 300 C) 16 Sercos III drives (LMC 400 C) 99 Sercos III drives (LMC 600 C) Lexium LXM62 The modular servo drive system Lexium LXM62 is designed for the operation of servo drives in a multi-axis group. The power electronic components of the LXM62 are fitted inside the switch cabinet. Using a common DC bus, the central power supply supplies the connected servo con verters with the power required. The servo converter Single- and Double Drive provides the necessary phase currents for the position control of the connected servo motors. According to the different re quirements in relation to the individual servo axes of the application, the Single- and Double Drives are available in different current strength classes. The Lexium LXM62 simplifies the wiring of the devices in relation to the initial start-up and service cases. This also applies to the cable connection of the enclosed devices to the field. Hereby all the connectors that can be connected from the outside (power input, DC bus, 24 Vdc-supply, SERCOS, motor, encoder, IOs, IO-supply, ready and inverter enable) are designed so that a fast, simple configuration on the device can be realized without tools. ELAU GmbH Lexium LXM62 Page 3

1 System overview BSH Servo motor The BSH AC servo motors meet the rigorours demands of dynamic and precision. Five flange sizes with different grades of torque offer the right drive solution for application. high dynamic AC servo motors The BSH motor has a low internal moment of inertia and a high overload capability, which allow the motor to meet precision, dynamics and efficiency requirements. The BSH motors are compatible with SM Motors and are available in five different flange sizes: BSH-055 BSH-070 BSH-100 BSH-140 BSH-205 Brief summary of technical data: Developed for high dynamics and precision Single tooth winding small compact size high power density low internal moment of inertia high overload capability high resistance to winding damages low detent torque Page 4 Lexium LXM62 ELAU GmbH

1.1 Type code 1.1 Type code 1.1.1 Power Supply Figure 1-2: Type code Power Supply ELAU GmbH Lexium LXM62 Page 5

1 System overview 1.1.2 Single/Double Drive Figure 1-3: Type code Drive-Module Page 6 Lexium LXM62 ELAU GmbH

2.1 Ambient conditions 2 Technical data 2.1 Ambient conditions Procedure Parameters Value Basis Operation Class 3K3 IEC/EN 60721-3-3 Protection class housing Protection class installation site Degree of pollution 2 Ambient temperature +5 C...+55 C Power reduction at increased ambient temperature Condensation Icing another water IP 20 with plugged-in connectors IP54, if safety circuit with Inverter Enable is used +40 C...+55 C (from +40 C: -2% per K at I NC and I SC ) no no no Relative humidity 5%... 85% Class 3M3 Vibration 10 m/s 2 Shock 100 m/s 2 Transport Class 2K3 IEC/EN 60721-3-2 Long-term storage in transport packaging Ambient temperature -25 C...+70 C Condensation Icing another water no no no Relative humidity 5%... 85% Class 2M2 Vibration 10 m/s 2 Shock 300 m/s 2 Class 1K4 IEC/EN 60721-3-1 Ambient temperature -25 C...+55 C Condensation Icing another water no no no Relative humidity 5%... 85% Table 2-1: Ambient conditions LXM62 ELAU GmbH Lexium LXM62 Page 7

2 Technical data 2.2 Standards and regulations CE EC Low Voltage Directive 2006/95/EC EN 61800-5-1:2007 EC EMC Directive 2004/108/EC EN 61800-3:2004 EC Machinery Directive 2006/42/EC UL Table 2-2: Standards and regulations EN 60529: IP protection EN 60204-1:2006 UL 508C: Power Conversion Equipment Functional safety EN ISO 13849-1:2006, PL d, Category 3 EN 61508:2001, SIL 2 Table 2-3: Standards and regulations - Functional safety Page 8 Lexium LXM62 ELAU GmbH

2.3 Mechanical and electrical data 2.3 Mechanical and electrical data 2.3.1 Power Supply Product configuration Name Parameters Value Item name LXM62PD84 Power supply Rated supply voltage 3 AC Min. 380 Vac (-10%) / Nom. 400 Vac / Max. 480 Vac (+10%) Rated supply voltage 3 AC Min. 208 Vac (-10%) / Nom. 230 Vac / Max. 360 Vac (+10%) Adjust the parameter "MainsVoltageMode" of the Power Supply according to the nominal supply voltage. Rated supply voltage 1 AC Supply frequency Min. 208 Vac (-10%) / Nom. 230 Vac / Max. 270 Vac (+10%) 48..63 Hz Control voltage 24 Vdc (-20 % / +25 %) Control current Max. 50 A (no overload permissible) DC circuit DC_Bus Voltage 270 Vdc to 700 Vdc DC link capacity Overvoltage Rated current (I NC ) Peak current 1 s (I SC ) Rated output Peak power U Bleeder ON U Bleeder OFF DC bus unloading time 1.36 mf 860 Vdc 21 A for 1AC infeed 42 A for 3AC infeed 42 A for 1AC infeed 84 A for 3AC infeed 22.1 kw for 3 400 Vac 26.6 kw for 3 480 Vac 44.2 kw for 3 400 Vac 53.2 kw for 3 480 Vac 830 Vdc 810 Vdc Internal braking resistor Resistance 15 Ω Permanent power Peak power Max. 15 min 400 W 46 kw Interfaces Sercos /// integrated Stray power Electronics power supply 15 W Bleeder (internal) 400 W Outputs Relay-outputs Ready relay, up to 6 A (max) by 150 Vac Ready relay, up to 6 A (max) by 35 Vdc or 1 A (max) by 70 Vdc Dimensions Housing D x W x H 270 mm x 89.5 mm x 310 mm (10.63 in. x 3.52 in. x 12.20 in.) Weight Weight (with packaging) 6.3 kg (7.3 kg) Radio interference level C3 (C2 with additional filter measures) Overvoltage category III (EN 61800-5-1:2007) II starting a installation altitude of 2000 m ELAU GmbH Lexium LXM62 Page 9

2 Technical data Name Parameters Value Degree of pollution - 2 (EN 61800-5-1:2007) Table 2-4: Technical data for power supply 2.3.2 Single Drive Product configuration Name Parameters Value Item name LXM62DU60A LXM62DD15A LXM62DD27A Power supply Control voltage / -current 24 Vdc (-20 %... +25 %) Control voltage / control current (with holding brake) DC_Bus Voltage DC link capacity 110 µf Overvoltage 24 Vdc (-10 %... +6 %) / 3 A (max) 250 Vdc.. 700 Vdc 900 Vdc Motor connection Rated current (8kHz) 2 A eff 5 A eff 7 A eff Stray power Peak current 6 A eff 15 A eff 27 A eff Cycle frequency Electronics power supply (8kHz) Power supply (8kHz) 8 khz (4/16 khz in preparation) 25 W 8.5 W/A Interfaces SERCOS III integrated Encoder - Hiperface Digital inputs/outputs Voltage 24 Vdc (-20%... +25%) Power Supplies 500 ma / max. current consumption 3 A Digital inputs 2 inputs with switching level Type I according to EN 61131-2 Low level: -3... 5 Vdc High level: 15... 30 Vdc Filter: 1 ms/5 ms (configurable) Digital inputs or TP 2 inputs with switching level Type I according to EN 61131-2 Digital inputs or digital outputs Low level: -3... 5 Vdc High level: 15... 30 Vdc Filter: 1 ms/5 ms (configurable) Filter for TP: 100 μs/5 ms (configurable) 2 inputs/outputs (bidirectional) Input with switching level Type I according to EN 61131-2 Low level: -3... 5 Vdc High level: 15... 30 Vdc Filter: 1 ms/5 ms (configurable) Output InverterEnable Inputs Number: 1 High level: (+VL - 3V) < V out < +VL Output current: max. 500 ma per output STO active: -3 V U IEX 5 V max. downtime 500μs by U IEX > 20 V and dynamic control max. switching frequency of input signal: max. 1 Hz Dimensions Housing D x W x H 270 mm x 44.5 mm x 310 mm (10.63 in. x 1.75 in. x 12.20 in.) Page 10 Lexium LXM62 ELAU GmbH

2.3 Mechanical and electrical data Name Parameters Value Weight Weight (with packaging) 3 kg (4 kg) Ventilation Type of fan no fan Internal fan Internal fan Overvoltage category Table 2-5: Technical Data Single Drive III (EN 61800-5-1:2007) ELAU GmbH Lexium LXM62 Page 11

2 Technical data 2.3.3 Double Drive Product configuration Power supply Name Parameters Value Item name LXM62DU60B LXM62DD15B LXM62DD27B Control voltage / -current 24Vdc (-20 %...+25 %) Control voltage / control current with holding 24 Vdc (-10 %... +6 %) / 3 A (max) brake DC_Bus Voltage DC link capacity 110 µf Overvoltage 250 Vdc.. 700 Vdc 900 Vdc Motor connection Rated current (8kHz) 2 x 2 A eff 2 x 5 A eff 2 x 7 A eff Stray power Peak current 2 x 6 A eff 2 x 15 A eff 2 x 27 A eff Cycle frequency Electronics power supply Power supply (4kHz) 8 khz (4/16 khz in preparation) 25 W 8.5 W/A (per axis) Interfaces SERCOS III integrated Encoder - Hiperface Digital inputs/outputs Voltage 24 Vdc (-20%... +25%) Power Supplies 500 ma / max. current consumption 3 A Digital inputs 2 x 2 inputs with switching level Type I according to EN 61131-2 Low level: -3... 5 Vdc High level: 15... 30 Vdc Filter: 1 ms/5 ms (configurable) Digital inputs or TP 2 x 2 inputs with switching level Type I according to EN 61131-2 Digital inputs or digital outputs Low level: -3... 5 Vdc High level: 15... 30 Vdc Filter: 1 ms/5 ms (configurable) Filter for TP: 100 μs/5 ms (configurable) 2 x 2 inputs/outputs (bidirectional) Inputs with switching level Type I according to EN 61131-2 Low level: -3... 5 Vdc High level: 15... 30 Vdc Filter: 1 ms/5 ms (configurable) Outputs InverterEnable Inputs Number: 2 High level: (+VL - 3V) < V out < +VL Output current: max. 500 ma per output STO active: -3 V U IEX 5 V max. downtime 500 μs at U IEX > 20 V and dynamic control max. switching frequency of input signal: max. 1 Hz Dimensions Housing D x W x H 270 mm x 44.5 mm x 310 mm (10.63 in. x 1.75 in. x 12.20 in.) Weight Weight (with packaging) 3 kg (4 kg) Ventilation - no fan Internal fan Page 12 Lexium LXM62 ELAU GmbH

2.3 Mechanical and electrical data Name Parameters Value Overvoltage category III (EN 61800-5-1:2007) Table 2-6: Technical Data Double Drive ELAU GmbH Lexium LXM62 Page 13

2 Technical data 2.4 Electrical connections 2.4.1 Power Supply CN1 CN6 CN5 CN3 CN2 CN4 CN7 Figure 2-1: Connection overview Power Supply Drive Connection Meaning Connection cross-section [mm 2 ]/ [AWG] Tightening torque [Nm] / [lbf in] CN1 Bus Bar Module - / - 2.5 / 22.14 CN2/CN3 SERCOS III communication - / - - / - CN4 Ready relay output 0.2 1.5 / 24... 16 - / - CN5 24Vdc 0.5 16 / 20... 6 - / - CN6 Mains connection 0.75 16 / 18... 6 - / - CN7 DC bus output 0.2... 6 / 24... 10 - / - Ground conductor 10 (cable shoe) / 6 3.5 / 30.98 CN1 - Bus Bar Module The DC bus voltage and the 24Vdc control voltage will be distributed and the protective conductor connected via the Bus Bar Module. A separate cabling is not required. Pin Name Meaning 1 Ground conductor 2 DC- - DC bus voltage 3 DC + Dc bus voltage + 4 24 V Supply voltage + 5 0 V Supply voltage - Table 2-7: Electrical connection - Bus Bar Module Page 14 Lexium LXM62 ELAU GmbH

2.4 Electrical connections CN2/CN3 - SERCOS III The Sercos /// connection is used for communication between the controller and the power supply drive. Pin Name Meaning 1.1 Eth0_Tx+ Positive transmission signal 1.2 Eth0_Tx+ Negative transmission signal 1.3 Eth0_Rx+ Positive received signal 1.4 n.c. - 1.5 n.c. - 1.6 Eth0_Tx+ Negative received signal 1.7 n.c. - 1.8 n.c. - 2.1 Eth1_Tx+ Positive transmission signal 2.2 Eth1_Tx+ Negative transmission signal 2.3 Eth1_Rx+ Positive received signal 2.4 n.c. - 2.5 n.c. - 2.6 Eth1_Tx+ Negative received signal 2.7 n.c. - 2.8 n.c. - Table 2-8: Electrical connection - SERCOS III CN4 - Ready Relay output Following initialization of the Power Supply Drive, the operation ready contact is activated. ❶ ❷ Pin Name Meaning NOTE 1 RDY1 Ready contact potential-free contact 2 RDY2 Ready contact potential-free contact Table 2-9: Electrical connection - Ready Relay Output CN5-24V The 24V input supplies the internal logic assemblies as well as the holding brakes of the complete axis group, connected to the axis modules. ❶ ❷ Pin Name Meaning 1 0 V Supply voltage 2 24 V Supply voltage Table 2-10: Electrical connection - 24V input The insulation-stripped length of the wires of the 24V input connector is 18 mm (0.71 in.). ELAU GmbH Lexium LXM62 Page 15

2 Technical data CN6 - Mains connection The Power Supply is supplied with voltage via the power connection. The rated voltage is 230V to 480V. ❶ ❷ ❸ ❹ Pin Name Meaning 1 Ground conductor 2 L3 External conductor L3 3 L2/N External conductor L2/N 4 L1 External conductor L1 Table 2-11: Electrical connection - mains The insulation-stripped length of the wires of the AC infeed connectors is 18mm (0.71 in.). CN7 - DC bus output The DC bus output can be used for an external bleeder module or a reverse module. ❶ ❷ ❸ Pin Name Meaning 1 DC + Dc bus voltage + 2 not assigned 3 DC- - DC bus voltage Table 2-12: Electrical connection - DC bus output The insulation-stripped length of the wires of the DC bus connector is 15mm (0.59in.). Page 16 Lexium LXM62 ELAU GmbH

2.4 Electrical connections 2.4.2 Single/Double Drive CN7 CN9 CN1 CN3 CN2 CN6 CN4 CN5 CN10 CN8 Figure 2-2: Connection overview Single Drive Servo/ Double Drive Servo Connection Meaning Connection cross-section [mm 2 ]/ [AWG] Tightening torque [Nm] / [lbf in] CN1 Bus Bar Module - / - 2.5 / 22.13 CN2/CN3 SERCOS III - / - - CN4 Digital inputs/outputs 0.25-1.5 / 24-16 - CN5 24V supply for digital inputs/outputs 0.25-1.5 / 24-16 - CN6 InverterEnable 0.2-1.5 / 24-16 - CN8/CN10 CN7/CN9 Motor phases CN8 - axis A CN10 - axis B (only for double drive) Encoder connector CN7 - axis A CN9 - axis B (only for double drive) 0.2-6 / 24-10 - - / - - Shielded connector - / - 3.5 / 30.98 CN1 - Bus Bar Module The DC bus voltage and the 24Vdc control voltage will be distributed and the protective conductor connected via the Bus Bar Module. A separate cabling is not required. Pin Name Meaning 1 Ground conductor 2 DC- - DC bus voltage 3 DC + Dc bus voltage + 4 24 V Supply voltage + 5 0 V Supply voltage - Table 2-13: Electrical connection - Bus Bar Module ELAU GmbH Lexium LXM62 Page 17

2 Technical data CN2/CN3 - SERCOS III The Sercos /// connection is used for communication between the controller and the power supply drive. Pin Name Meaning 1.1 Eth0_Tx+ Positive transmission signal 1.2 Eth0_Tx+ Negative transmission signal 1.3 Eth0_Rx+ Positive received signal 1.4 n.c. - 1.5 n.c. - 1.6 Eth0_Tx+ Negative received signal 1.7 n.c. - 1.8 n.c. - 2.1 Eth1_Tx+ Positive transmission signal 2.2 Eth1_Tx+ Negative transmission signal 2.3 Eth1_Rx+ Positive received signal 2.4 n.c. - 2.5 n.c. - 2.6 Eth1_Tx+ Negative received signal 2.7 n.c. - 2.8 n.c. - Table 2-14: Electrical connection - SERCOS III CN4 - Digital inputs / outputs ❶ ❷ ❸ ❹ ❺ ❻ ❼ ❽ ❾ ❶⓿ ❶❶ ❶❷ Pin Name Meaning 1 A_DI1 Axis A digital input 1 - touchprobe 2 A_DI2 Axis A digital input 2 - touchprobe 3 A_DI3 Axis A digital input 1 4 A_DI4 Axis A digital input 2 5 A_DI5 Axis A digital input / output 3 6 A_DI6 Axis A digital input / output 4 7 B_DI1 Axis B Digital input 1 - Touchprobe (only double drive) 8 B_DI2 Axis B Digital input 2 - Touchprobe (only double drive) 9 B_DI3 Axis B Digital input 1 (only double drive) 10 B_DI4 Axis B Digital input 2 (only double drive) 11 B_DI5 Axis B Digital input/output 3 (only double drive) 12 B_DI6 Axis B Digital input/output 4 (only double drive) Table 2-15: Electrical connection - digital inputs / outputs CN5-24V supply for DIO The 24V DIO supply connector supplies the digital inputs/outputs of the drives with the required energy. ❶ ❷ ❸ ❹ Pin Name Meaning 1 0VA External digital input/output voltage 2 24VA External digital input/output voltage 3 0VB External digital input/output voltage 4 24VB External digital input/output voltage Table 2-16: Electrical connection - 24V supply for DIO Page 18 Lexium LXM62 ELAU GmbH

2.4 Electrical connections CN6 - InverterEnable The Inverter Enable signal supplies the gate driver with voltage. In this way the STO (Safe Torque Off) requirements according to EN 61508:2001 and EN ISO 13849-1:2006 are met. IEA1 is coupled internally with IEA2, and IEB1 is coupled internally with IEB2. ❶ ❷ ❸ ❹ Pin Name Meaning Range 1 IEA1 InverterEnable signal for axis A 18V...30V 2 IEA2 InverterEnable signal for axis A 18V...30V 3 IEB1 InverterEnable signal for axis B 18V...30V 4 IEB2 InverterEnable signal for axis B 18V...30V Table 2-17: Electrical connection - InverterEnable CN7/CN9 - Encoder connector The encoder connection (Hiperface) has been specified by SICK STEGMANN. The Hiperface connection consists of a standard, differential, digital connection (RS485 = 2 wires), an analog connection (sine- and cosine signal = 4 wires) and a mains connection to supply the encoder (+10V, GND = 2 wires). Pin Name Meaning 1 Cos Cosine track axis A/B 2 RefCos Reference signal cosine axis A/B 3 Sin Sine track axis A/B 4 RS485+ Positive RS485 signal axis A/B 5 RS485- Negative RS485 signal axis A/B 6 RefSin Reference signal sine axis A/B 7 not assigned - 8 not assigned - A P10V Supply voltage Encoder A/B B GND Mass A/B Table 2-18: Electrical connection - encoder connector ELAU GmbH Lexium LXM62 Page 19

2 Technical data CN8 - Axis A CN10 - Axis B CN8/CN10 - Motor connector (Axis A/B) The motor signals U, V and W supply the motor with the required energy. The temperature signals are connected to a temperature sensor to measure the temperature of the motor. The holding brake output supplies the holding brake in the motor with the required energy. ❸ ❹ ❺ ❻ ❼ ❽ ❶ ❷ Pin Name Meaning 1 MTemp- Temperature negative signal - Axis A/B 2 MTemp+ Temperature positive signal - Axis A/B 3 BR- Brake negative signal - Axis A/B 4 BR+ Brake positive signal - Axis A/B 5 Protective conductor protective earth ground - Axis A/B 6 U Motor phase U - Axis A/B 7 V Motor phase V - Axis A/B 8 W Motor phase W - Axis A/B Table 2-19: Electrical connection - Motor connector The insulation-stripped length of the wires of the motor connector is 15mm (0.59in.). The maximum length of the motor supply cable is 75 m (246.06 ft). Page 20 Lexium LXM62 ELAU GmbH

2.5 Dimensions 2.5 Dimensions For a table to calculate the dimension specifications (see 3.1.1 Length)in mm. 2.5.1 Power Supply A B C D E F 1 2 3 22 45 Ø 6,5 (2x) Ø 11,5 (2x) 6,5 6,5 89 89,5 4 5 6 7 270 240 310 296 7 Figure 2-3: Dimensions of the power supply in mm (calculation table in the appendix) ELAU GmbH Lexium LXM62 Page 21

2 Technical data 2.5.2 Single/Double Drive A B C D E F 1 2 3 44 22 240 4 6 5 270 Ø 6,5 6,5 44 44,5 310 296 7 Figure 2-4: Dimensions single/double drive in mm (calculation table in the appendix) Page 22 Lexium LXM62 ELAU GmbH

3.1 Units and conversion tables 3 Appendix 3.1 Units and conversion tables 3.1.1 Length in ft yd m cm mm in - / 12 / 36 * 0.0254 * 2.54 * 25.4 ft * 12 - /3 * 0.30479 * 30.479 * 304.79 yd * 36 * 3 - * 0.9144 * 91.44 * 914.4 m / 0.0254 / 0.30479 / 0.9144 - *100 * 1000 cm / 2.54 / 30.479 / 91.44 / 100 - * 10 mm / 25.4 / 304.79 / 914.4 / 1000 / 10-3.1.2 Mass lb oz slug 0.22 kg g lb - * 16 * 0.03108095 * 0.4535924 * 453.5924 oz / 16 - * 1.942559*10-3 * 0.02834952 * 28.34952 slug / 0.03108095 / 1.942559*10-3 - * 14.5939 * 14593.9 0.22 kg / 0.45359237 / 0.02834952 / 14.5939 - * 1000 g / 453.59237 / 28.34952 / 14593.9 / 1000-3.1.3 Force lb oz p dyne N lb - * 16 * 453.55358 * 444822.2 * 4.448222 oz / 16 - * 28.349524 * 27801 * 0.27801 p / 453.55358 / 28.349524 - * 980.7 * 9.807*10-3 dyne / 444822.2 / 27801 / 980.7 - / 100*10 3 N / 4.448222 / 0.27801 / 9.807*10-3 * 100*10 3-3.1.4 Output HP W HP - * 746 W / 746-3.1.5 Rotation min -1 (rpm) rad/s deg./s min -1 (rpm) - * π / 30 * 6 rad/s * 30 / π - * 57.295 deg./s / 6 / 57.295 - ELAU GmbH Lexium LXM62 Page 23

3 Appendix 3.1.6 Torque lb in lb ft oz in Nm kp m kp cm dyne cm lb in - / 12 * 16 * 0.112985 * 0.011521 * 1.1521 * 1.129*10 6 lb ft * 12 - * 192 * 1.355822 * 0.138255 * 13.8255 * 13.558*10 6 oz in / 16 / 192 - * 7.0616*10-3 * 720.07*10-6 * 72.007*10-3 * 70615.5 Nm / 0.112985 / 1.355822 / 7.0616*10-3 - * 0.101972 * 10.1972 * 10*10 6 kp m / 0.011521 / 0.138255 / 720.07*10-6 / 0.101972 - * 100 * 98.066*10 6 kp cm / 1.1521 / 13.8255 / 72.007*10-3 / 10.1972 / 100 - * 0.9806*10 6 dyne cm / 1.129*10 6 / 13.558*10 6 / 70615.5 / 10*10 6 / 98.066*10 6 / 0.9806*10 6-3.1.7 Moment of inertia lb in 2 lb ft 2 kg m 2 kg cm 2 kg cm 2 s 2 oz in 2 lb in 2 - / 144 / 3417.16 / 0.341716 / 335.109 * 16 lb ft 2 * 144 - /3 *0.30479 *30.479 *304.79 kg m 2 * 3417.16 / 0.04214 - *0.9144 *91.44 *914.4 kg cm 2 * 0.341716 / 421.4 /0.9144 - *100 *1000 kg cm 2 s 2 * 335.109 / 0.429711 /91.44 /100 - *10 oz in 2 / 16 / 2304 / 54674 / 5.46 / 5361.74-3.1.8 Temperature F max K F - ( F - 32) * 5/9 ( F - 32) * 5/9 + 273.15 max C * 9/5 + 32 - C + 273.15 K (K - 273.15) * 9/5 + 32 K - 273.15-3.1.9 Conductor cross-section AWG 1 2 3 4 5 6 7 8 9 10 11 12 13 mm 2 42.4 33.6 26.7 21.2 16.8 13.3 10.5 8.4 6.6 5.3 4.2 3.3 2.6 AWG 14 15 16 17 18 19 20 21 22 23 24 25 26 mm 2 2.1 1.7 1.3 1.0 0.82 0.65 0.52 0.41 0.33 0.26 0.20 0.16 0.13 Page 24 Lexium LXM62 ELAU GmbH