Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Similar documents
User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

400Amp True RMS AC Clamp Meter + NCV

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

400Amp True RMS AC/DC Clamp Meter Model EX613

200Amp AC Clamp Meter + NCV Model MA250

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

USER'S MANUAL DMR-6700

User s Guide. Model MA A AC Mini Clamp-on Meter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Autoranging Multimeter Extech EX503

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

Compact MultiMeters + Voltage Detector

User s Guide. Digital AC/DC Clamp Meter Model 38394

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

User Guide. Digital AC/DC Clamp Meter Model 38394

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

R/C SMD Tweezers Multimeter Model RC200

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Not for Reproduction

AC/DC CLAMP METER USER S MANUAL

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

DM-45 Digital Multimeter

NOTE: Fully read and understand this manual before using this Digital Multimeter.

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

OPERATING INSTRUCTION

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

MODEL: D03128 CLAMP METER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

600A Clamp Meters w/tightsight Display

MW3105 DIGITAL CLAMP MULTIMETER

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Multifunction AC/DC Voltage Tester

Digital Clamp Meter (TRMS) Model : 2727

CONTENTS MS2033A. 1.Introduction Safety Information...01

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

AMM-1022 Digital Multimeter USER`S MANUAL

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

User Manual. All rights reserved. Specifications are subject to change without notice.

PeakTech 3355 / 3360

ET-3888 True RMS Clamp Meter. User Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DVM1190 DIGITAL MULTIMETER

UT207A/208A/209A Operating Manual. Table of Contents

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

DM-46 Instruction Manual

OPERATOR S INSTRUCTION MANUAL

DM-46 Instruction Manual

USER S MANUAL DMR-1500

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

User Manual. All rights reserved. Specifications are subject to change without notice.

Sales: Technical: Fax:

User Manual Digital Clamp Multimeter. model no.: MSR-C600

AC Clamp Meter + Phase Rotation Tester

DIGITAL MULTIMETER INSTRUCTION MANUAL

Mini Clamp Meter Model:

DCM730. Digital Clamp Meter User s Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Digital automotive analyser 13 function with ic

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Pen Multimeter. Model

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

User Manual Digital Multimeter

BENNING. CM7 Electrical Tester. Service Information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Model UT10A: OPERATING MANUAL Table of Contents (1)

KMD-S04 Multímetro de bolsillo

User Guide. AC/DC Mini Clamp Meter. Model

User Manual Digital Multimeter. model no.: MSR-U1000

Digital Automotive Analyser 14 Function With IC

Transcription:

User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 1 8/7/2017 2:22:29 PM

Introduction The Digi-Sense Compact Autoranging Clamp Meters (400 A AC Model 20250-55; 400 A AC/DC Model 20250-56) offer all the basic features needed for measurement. The doublemolded plastic housing and jaw are designed for use in tight places. A large backlit display provides easy-to-read measurements. The instruments are fully tested and calibrated to NIST-traceable standards. Careful use of the meter will provide years of reliable service. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation 2 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 2 8/7/2017 2:22:29 PM

SAFETY NOTES Do not exceed the maximum allowable input range of any function. Do not apply voltage to meter when resistance function is selected. Set the function switch OFF when the meter is not in use. WARNINGS Set rotary function switch to the appropriate position before measuring. When measuring volts, do not switch to current/resistance modes. When changing ranges using the rotary function switch, always disconnect the test leads from the circuit under test. Do not exceed the maximum rated input limits: Input Limits Function Maximum Input, Maximum Input, Model 20250-55 Model 20250-56 A 400 A AC 400 A AC/DC V 600 V AC/DC 600 V AC/DC Frequency, Duty cycle, Resistance, Diode, Continuity, Capacitance Test 250 V AC/DC 250 V AC/DC Temperature ( C/ F) 250 V AC/DC 250 V AC/DC 3 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 3 8/7/2017 2:22:29 PM

CAUTIONS Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. Use great care when making measurements if the voltages are greater than 25 VAC rms or 35 VDC. These voltages are considered a shock hazard. Remove the battery if the meter is to be stored for long periods. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance, or Continuity tests. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not "live". If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 4 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 4 8/7/2017 2:22:29 PM

Unpacking Check individual parts against the list of items below. If anything is missing or damaged, please contact your instrument supplier immediately. 1. Meter 2. Test leads 3. Temperature probe 4. Carrying case 5. 9 V battery 6. User manual 7. NIST-traceable calibration report with data Key Features Built-in noncontact AC voltage detector Durable double-molded housing 1 3 16" (30 mm) jaw opening CAT III 1000 V safety rating Electronic overload protection Autoranging with auto power-off Peak Hold function that captures the peak AC current or voltage reading (model 20250-56 only) 5 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 5 8/7/2017 2:22:29 PM

Meter Description (Model 20250-55) 1. Current clamp 2. Noncontact AC voltage indicator light 3. Clamp trigger 4. Rotary function switch 5. Data HOLD / Backlight button 6. Relative button 7. 4000-count LCD 8. MODE select button 9. Range button 10. Hz% button 11. COM input jack 12. V Ω CAP TEMP Hz jack 13. Battery cover Ω Meter Description (Model 20250-56) 1. Current clamp 2. Noncontact AC voltage indicator light 3. Clamp trigger 4. Rotary function switch 5. Data HOLD button 6. Backlight button 7. 4000-count LCD 8. MODE select button 9. PEAK button 10. Relative button 11. COM input jack 12. V Ω CAP TEMP Hz jack 13. Battery cover 6 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 6 8/7/2017 2:22:31 PM

Display Layout (Model 20250-55) 1. AC DC AC (alternating current) and 2. DC (direct current) Minus sign 3. 8.8.8.8 4000 count (0 to 3999) measurement reading 4. AUTO Autorange mode 5. REL ( ) Relative mode 6. Diode test mode 7. ))) Audible continuity 8. HOLD Data HOLD mode 9. C, F, µm,v, A,K,M,Ω Units of measure list 10. Hz % Frequency/duty cycle test mode Display Layout (Model 20250-56) 1. AC DC AC (alternating current) and DC 2. (direct current) Minus sign 3. 8.8.8.8 4000 count (0 to 3999) measurement reading with analog bar graph 4. HOLD Data HOLD mode 5. REL ( ) Relative mode 6. AUTO Autorange mode 7. MAX MIN Max/Min Hold mode 8. Pmax Pmin Pmax Pmin Hold mode 9. ))) Audible continuity 10. Diode test mode 11. Hz % Frequency/duty cycle test mode 12. Ω,F,A,V, C, F Units of measure list 7 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 7 8/7/2017 2:22:31 PM

Setup and Operation Note: Read and understand all warning and precaution statements listed in the safety section of this operation manual prior to using this meter. Set the rotary function switch to the OFF position when the meter is not in use. AC and AC/DC Current Measurements WARNING: Ensure that the test leads are disconnected from the meter before making current clamp measurements. 1. Set the rotary function switch to the 400A or 40A or 4A range. 2. For model 20250-56 only, select AC or DC by pressing the MODE button. 3. If the measuring range is unknown, select the higher range first then move to the lower range as necessary. 4. Press the trigger to open jaw. Fully enclose one conductor to be measured (see diagram). The LCD will display the reading. 5. In DCA mode, to ensure the reading is correct, press the REL button to clear the reading on the LCD before measurement. The LCD will display the reading (model 20250-56 only). Ω Ω 8 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 8

AC/DC Voltage Measurements 1. Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. 2. Set the rotary function switch to the V position. 3. Select AC or DC with the MODE button. 4. Connect the test leads in parallel to the circuit under test. 5. Read the voltage measurement in the display. Resistance and Continuity Measurements 1. Insert the black test lead into the negative COM terminal and the red test lead into the positive terminal. 2. Set the rotary function switch to the Ω ))) position. 3. Touch the test probe tips across the circuit or component under test. It is best to disconnect one side of the device under test so the rest of the circuit will not interfere with the resistance reading. 4. For Resistance tests, read the resistance value in the display. 9 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 9

Diode and Continuity Measurements 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jack. 2. Set the rotary function switch to the Ω ))) position. 3. Press the MODE button until appears in the display. 4. Touch the test probes to the diode under test. Forward voltage will indicate 0.4 V to 0.7 V. Reverse voltage will indicate OL.. Shorted devices will indicate near 0 mv and an open device will indicate OL in both polarities. Red Black Black Red Forward test Reverse test 5. For Continuity tests, if the resistance is <150 Ω (20250-55) or <50 Ω (20250-56), a tone will sound. Capacitance Measurements (Model 20250-56 Only) WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords. 1. Set the rotary function switch to the (CAP) position. 2. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack. 3. Touch the test leads to the capacitor to be tested. 4. Read the capacitance value on the display. 10 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 10

Frequency or % Duty Cycle Measurements 1. For model 20250-55, set the rotary function switch to the V position, then press the Hz% button to select Hz or % duty. 2. For model 20250-56, set the rotary function switch to the Hz position. (Model 20250-56 does not feature % duty cycle measurement.) 3. Insert the black lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack. 4. Touch the test probe tips to the circuit under test. 5. Read the frequency value on the display. Temperature Measurements WARNING: To avoid electric shock, disconnect both test probes from any source of voltage before making a temperature measurement. 1. Set the rotary function switch to C or F units. 2. For model 20250-56 only, select C or F units by pressing the MODE button. 3. Insert the temperature probe into the negative COM and V jacks, making sure to observe the correct polarity. 4. Touch the probe head to the part whose temperature you wish to measure. Keep the probe touching the part under test until reading stabilizes (about 30 seconds). 5. Read the temperature in the display. The digital reading will indicate the proper decimal point and value. WARNING: To avoid electric shock, be sure the thermocouple has been removed before changing to another measurement function. 11 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 11

Noncontact AC Voltage Measurements WARNING: Risk of Electrocution. Before use, always test the voltage detector on a known live circuit to verify proper operation 1. Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 2. If AC voltage is present, the indicator light will illuminate. Note: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. Note: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation. MODE Button To select DC/ACV,OHM/ Diode/Continuity (CAP 20250-56 only). Data HOLD Button To freeze a reading on the screen, press the HOLD (H) button. While data HOLD is active, the HOLD display icon appears on the LCD. Press the data HOLD button again to resume normal operation. REL Button For Offset adjustment. (DCA and Capacitance zero on model 20250-56 only.) 12 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 12

RANGE Button (Model 20250-55 only) When the meter is first turned on, it defaults to autoranging. This automatically selects the best range for the measurements being made and is generally the optimal mode for most measurements. For measurement situations requiring that a range be manually selected, perform the following: 1. Press the RANGE button. The AUTO display indicator will turn off. 2. Press the RANGE button again to step through the available ranges until you select the range you want. 3. Press and hold the RANGE button for 2 seconds to exit the manual ranging mode and return to autoranging. PEAK Hold Button (Model 20250-56 only) The PEAK Hold function captures the peak AC voltage or current. The meter can capture negative or positive peaks as fast as 1 millisecond in duration. 1. Turn the rotary function switch to an A or V position. 2. Use the MODE button to select AC. 3. Allow time for the display to stabilize. 4. Press and hold the PEAK button until CAL appears in the display. This procedure will zero the range selected. 5. Press the PEAK button, Pmax will display. The display will update each time a higher positive peak occurs. 13 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 13

6. Press the PEAK button again, Pmin will display. The display will now update and indicate the lowest negative peak. 7. To return to normal operation, press and hold the PEAK button until the Pmin or Pmax indicator switches off. Note: If the rotary function switch position is changed after a calibration, the PEAK Hold calibration must be repeated for the new function selected. Automatic Power-Off To conserve battery life, the meter automatically turns off after 30 minutes of nonuse. 14 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 14

Specifications Function AC Current (50/60 Hz) DC Current DC Voltage AC Voltage (50 400 Hz) Resistance Capacitance Frequency Temperature, type K (probe accuracy not included) Model 20250-55 Model 20250-56 Range & Accuracy Range & Accuracy Resolution (% of reading) Resolution (% of reading) 4.000 AAC ±(2.5% + 12 dgts) 40.00 AAC ±(2.5% + 8 dgts) 40.00 AAC ±(2.5% + 8 dgts) 400.0 AAC ±(2.8% + 8 dgts) 400.0 AAC ±(2.8% + 5 dgts) 40.00 ADC ±(2.5% + 5 dgts) 400.0 ADC ±(2.8% + 5 dgts) 400.0 mvdc ±(0.8% + 2 dgts) 400.0 mvdc ±(0.8% + 2 dgts) 4.000 VDC 4.000 VDC 40.00 VDC ±(1.5% + 2 dgts) 40.00 VDC ±(1.5% + 2 dgts) 400.0 VDC 400.0 VDC 600.0 VDC ±(2 % + 2 dgts) 600.0 VDC ±(2% + 2 dgts) 400.0 mvac 4.000 VAC 4.000 VAC ±(1% + 10 dgts) 40.00 VAC ±(1.8% + 8 dgts) 40.00 VAC 400.0 VAC 400.0 VAC ±(1.5% + 5 dgts) 600.0 VAC ±(2.5% + 8 dgts) 600.0 VAC ±(2% + 5 dgts) 400.0 Ω ±(1.0% + 4 dgts) 400.0 Ω ±(1.0% + 4 dgts) 4.000 KΩ 4.000 KΩ 40.00 KΩ ±(1.5% + 2 dgts) 40.00 KΩ ±(1.5% + 2 dgts) 400.0 KΩ 400.0 KΩ 4.000 MΩ ±(2.5% + 3 dgts) 4.000 MΩ ±(2.5% + 3 dgts) 40.00 MΩ ±(3.5% + 5 dgts) 40.00 MΩ ±(3.5% + 5 dgts) 40.00 nf ±(5.0% rdg + 20 dgts) 400.0 nf 4.000 µf ±(3% rdg + 5 dgts) 40.00 µf 400.0 µf ±(4.0% rdg + 10 dgts) 4 mf ±(5% rdg + 10 dgts) 10 to 10 khz Sensitivity: 100 V (<50 Hz); 50 V (50 to 400 Hz; 15 V (401 Hz to 10 khz) ±(1.5% rdg + 2 dgts) 10 to 100 khz Sensitivity: 100 V (<50 Hz); 50 V (50 to 400 Hz; 15 V (401 Hz to 100 khz) ±(1.5% rdg + 2 dgts) 20.0 to 760.0 C ±(3% rdg + 5 C) 20.0 to 760.0 C ±(3% rdg + 5 C) 4.0 to 1400.0 F ±(3% rdg + 9 F) 4.0 to 1400.0 F ±(3% rdg + 9 F) 15 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 15

Specifications (continued) Clamp size Diode test Opening 1 3 16" (30 mm) approximately Test current of 0.3 ma typical; Open circuit voltage 1.5 V DC typical (20250-55), <3 V DC typical (20250-56). Continuity Threshold <150 Ω (20250-55), check <50 Ω (20250-56); Test current <0.5 ma Low-battery is displayed indication Overrange OL is displayed indication Measurement 2 per second, nominal rate Input 10 MΩ (VDC and VAC) impedance Display 4000 counts LCD AC Current 50 60 Hz (AAC) (20250-55), 50 60 Hz (AAC TRMS) (20250-56) AC Voltage 50 400 Hz (VAC) (20250-55), 50 60 Hz (VAC TRMS) (20250-56) Operating temperature Storage temperature Operating humidity 41 to 104 F (5 to 40 C) 4 to 140 F ( 20 to 60 C) Max 80% up to 87 F (31 C), decreasing linearly to 50% at 104 F (40 C) 16 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 16

Storage humidity <80% Operating 7000 ft (2000 meters) maximum altitude Overvoltage Category III 600 V Battery One 9 V battery Auto power-off 30 minutes approximately Weight 6.5 oz (183 g) Dimensions 7 3 4" x 2 3 4" x 1 9 16" (19.7 x 7 x 4 cm) Safety For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Cat. III 17 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 17

Maintenance, Recalibration, and Repair Cleaning and Storage The meter should be cleaned with a damp cloth and mild detergent when necessary. Do not use solvents or abrasives. Store the meter in an area with moderate temperature and humidity. Battery Replacement 1. Remove the one rear Phillips head screw. 2. Open the battery compartment. 3. Replace the old battery with one 9 V battery. 4. Replace the cover and secure the screw. 5. Dispose of the old battery properly. WARNING: To avoid electric shock, do not operate your meter until the battery door is in place and fastened securely. 18 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 18

It is recommended that Digi-Sense products are calibrated annually to ensure proper function and accurate measurements; however, your quality system or regulatory body may require more frequent calibrations. To schedule your recalibration, please contact InnoCal, an ISO 17025 calibration laboratory accredited by A2LA. Phone: 1-866-INNOCAL (1-866-466-6225) Fax: 1-847-327-2993 E-mail: sales@innocalsolutions.com Web: InnoCalSolutions.com 19 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 19

For Product and Ordering Information, Contact: Toll-Free: 1-800-323-4340 Phone: 1-847-549-7600 Fax: 1-847-247-2929 ColeParmer.com/Digi-Sense Toll-Free: 1-800-358-5525 Phone: 1-847-327-2000 Fax: 1-847-327-2700 Davis.com/Digi-Sense 1065DGMAN_20250-55,-56 Manual Part No. 00101-90 1065DGMAN_20250-55,-56 DS Clamp Meter Man.indd 20 8/7/2017 2:22:33 PM