Arrester Disconnector

Similar documents
ArresterFacts-002. Field Testing Arresters ArresterWorks.com. ArresterFacts are information modules pertaining to the arrester world.

What is the Value of a Distribution Arrester

ArresterFacts 024. Separation Distance for Substations. ArresterFacts 024 Separation Distance for Substations. September 2014 Rev 7 Jonathan Woodworth

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Insulation Coordination Fundamentals Where Arrester and Insulator Characteristics Meet

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

TN, TT & IT Earthing Arrangements

Substation Insulation Coordination Study

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

A DUMMIES GUIDE TO GROUND FAULT PROTECTION

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

The Many Uses of Transmission Line Arresters

CONTENTS. 1. Introduction Generating Stations 9 40

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

Grounding System Theory and Practice

This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor.

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

Arrester 2050 JONATHAN WOODWORTH

Education & Training

SURGE ARRESTERS AND TESTING. Keith Hill Doble Engineering Company

Tab 2 Voltage Stresses Switching Transients

2 Grounding of power supply system neutral

Overvoltage Protection

Tab 8 Surge Arresters

2018 Consultant s Handbook Division 26 Electrical ARC Flash Hazard Analysis

Surge Arresters. VariSTAR Type AZS Normal Duty Distribution Class MOV Arrester

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

Arc Flash Analysis and Documentation SOP

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

INTRINSIC SAFETY BASIC PRINCIPLES

Voltage Sag Mitigation by Neutral Grounding Resistance Application in Distribution System of Provincial Electricity Authority

Use of Advanced Monitoring Technology to Detect Incipient Failure of Line Equipment

Coordination of surge arresters in DC 3 kv railway traction system field tests

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

In order to minimise distribution (11 and 22 kv) feeder breaker

Utility System Lightning Protection

A New Use for Fault Indicators SEL Revolutionizes Distribution System Protection. Steve T. Watt, Shankar V. Achanta, and Peter Selejan

UltraSIL Polymer-Housed VariSTAR Normal-Duty, Heavy-Duty and Riser Pole Distribution-Class Arresters

Selective Coordination for Emergency and Legally-Required Standby Power Distribution Systems

Our experience. Our products

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

UltraSIL Polymer-Housed Evolution Distribution Class Surge Arrester Certified Test Report

Electrical Measurement Safety. Sponsored By:

ACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng

HIGH VOLTAGE Insulation Coordination

ADDENDUM NO. 2 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

EASQ ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) MARKING SCHEDULE. SECTION 1 Marks Reference Marking notes Qu 1 A 10 MΩ (2 marks)

SUBJECT CODE : EE6702 SUBJECT NAME: Protection & switchgear STAFF NAME : Ms.J.C.Vinitha

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Specialists in HV and MV test and diagnostics. Testing in Substations

The Variable Threshold Neutral Isolator (VTNI)

IMP/007/011 - Code of Practice for the Application of Lightning Protection

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

Electrical Arc Hazards

2014 NEC Changes Part 1

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

International Journal of Advance Engineering and Research Development. Analysis of Surge Arrester using FEM

Specialty Switches. Inertia Engineering & Machine Works, Inc Hardaway Road, Stockton CA 95215

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Substation Design Volume VII

Outdoor Installation 2: Lightning Protection and Grounding

American Electrical Institute

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

Lightning test in lab. Symmetrical fault and protection. Olof Samuelsson

High voltage engineering

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems

7. INSPECTION AND TEST PROCEDURES

Frequently Asked Question on Isolated Power Supply(IPS)

# - - Internal * On Line Examination

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

GIS Disconnector Switching Operation VFTO Study

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

Fixed Series Compensation

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

MAJOR ADVANCES IN MV/LV SUBSTATIONS. Th.Grima et JF.Faltermeier. Groupe CAHORS, France SUMMARY

Short Circuit Current Calculations

3Ø Short-Circuit Calculations

Article 250 Grounding & Bonding

Hendrix Tap, Tie & Ground Wire

Exploring the Necessity of the Hot Hipot Test

Arc Flash Analysis Training

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

Transformers connected via a cable Overvoltage protection

EI HIGH VOLTAGE INSULATION TESTING POLICY

Spark Gap Surge Protectors For Lv Mains

Upgrading Your Electrical Distribution System To Resistance Grounding

I -limiter The world s fastest switching device

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

Webinar: An Effective Arc Flash Safety Program

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

1000 SERIES INSTALLATION SUPPLEMENT Rev

PROTECTION AGAINST FAULT CURRENT

THREE PHASE PAD MOUNTED DISTRIBUTION TRANSFORMER ARC FLASH TESTING JUNE 23, 2009 FERRAZ SHAWMUT HIGH POWER LABORATORY NEWBURYPORT, MA

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

1% Switchgear and Substations

G. KOEPPL Koeppl Power Experts Switzerland

Earthing of Electrical Devices and Safety

Transcription:

Arrester Disconnector ArresterFacts 005 Photo ArresterWorks Prepared by Jonathan Woodworth Consulting Engineer ArresterWorks May 4, 2008 Copyright ArresterWorks 2008 Jonathan J. Woodworth Page1

The Arrester Disconnector The Disconnector An arrester disconnector as seen in Figure 1 is a device connected in series with an arrester that separates the ground lead from the bottom of the arrester if the arrester has overloaded and failed. It is also known as a ground lead disconnector (GLD) or isolator. Disconnector Figure1 Graphic INMR Typical Disconnector The GLD only operates if power frequency fault current flows through the device during a failure. It will not operate from surge current. Basis of Operation Commonly used designs available today include a heating element, steady state bypass element and a separation element. Electrically it is represented by Figure 2. There are several variations of this design, but all fundamentally operate the same way. During steady state operation the arrester leakage current is conducted around the heating element and separation element. The separation element is generally a small explosive device that is heat activated. During lightning surges, the heat generated in the disconnector is not adequate to ignite the separation element. The separation element is designed such that it only operates when fault current flows through the device. Note: The standard arrester disconnector is not an interrupting device. It may break the fault current upon operation, but only under ideal conditions such as low fault currents. Since the disconnector does not interrupt fault current, an over-current device will be Disconnector Heating Element Activating Element Heater Steady State Bypass Element Figure 2 Typical Disconnector schematic Copyright ArresterWorks 2008 Jonathan J. Woodworth Page2

required to operate when an arrester is overloaded and fails. System Conditions relevant to proper use of a disconnector As stated in the last section, the GLD is only activated from power frequency fault current. Because of this operation requirement ungrounded systems and impedance grounded systems may not operate a GLD if the arrester fails. Some disconnector designs do have sensitivity in the 1 amp fault current range but most do not. Time Current Curve Each disconnector has a time current characteristic curve represented either graphically or tabular as shown in Figure 3. As stated earlier, since the disconnector is not a fault breaking or clearing device, the only curve that can be properly displayed is a disconnection initiation curve. Disconnection initiation is defined as the first sign of external arc voltage across the device during its disconnection operation. Over- Current Device & Disconnector Coordination 1000.00 100.00 Recommended TCC of Over Current Device 10.00 Time in Seconds 1.00 GLD Initial Disconnection 0.10 0.01 1 10 100 1000 10000 Power frequency current (A rms) Figure 3 Over-current Device vs. Disconnector Initiation Coordination with Over-current devices If an over-current device is upstream of an arrester with a disconnector, it is possible for the over-current to be faster than disconnector ignition capability. It is therefore prudent for the user of an arrester with a disconnector to coordinate the disconnector initial disconnection curve with the minimum melt curve of the overcurrent device. It can be generally assumed that if the over-current device is slower than a typical 20K fuse link curve, then Copyright ArresterWorks 2008 Jonathan J. Woodworth Page3

coordination with the disconnector is attained. Safety Aspects of Disconnector Disconnectors are generally installed at the earth end of the arrester as shown in Figure 4. In this configuration the bottom of the arrester becomes energized at line potential after the disconnector separates and the arrester fails short. This voltage distribution is quite different from its more common voltage distribution at steady state. It is important that arrester users of this type arrester be aware that full line potential can exist at the bottom of the arrester where it is normally at or near earth potential. For this reason, the bottom of the arrester should always be treated as if it can be at line potential. Another safety aspect of disconnectors to consider is that when the activating powder will separate the disconnector with considerable force and speed. This may cause the expulsion of small fragments and sparks. As stated above, since the GLD is not a breaking device, a resulting power frequency arc may be sustained for several cycles. This arc is also capable of melting metal and plastic parts which may drop to the ground. The third safety issue to consider with disconnectors is that the device is heat activated and should not be heated in an oven above 150C because it could activate the device. It should be noted that imparting an impact on as disconnector does not activate the powder since it is heat activated only. However care should be taken if the black power is impacted directly and heat is generated, it could ignite. Housing Insulating Hanger Disconnector before operation Disconnector after operation Figure 4 Typical Disconnector Configurations is heated to its activation temperature, it Copyright ArresterWorks 2008 Jonathan J. Woodworth Page4

Insulating Bracket Considerations From Figure 4, it can be surmised that once the disconnector has disconnected, the line to earth potential is then stressed across the insulating hanger. This stress may lead to tracking over the insulating hanger to earth if the disconnected unit is allowed to stay energized for long periods of time. The long term electrical and environmental withstand characteristics of the insulating hanger will need to be increased if the arrester is allowed to remain energized for more than a year. Installation Considerations and Lead Management It is important to note that when the disconnector operates and does disconnect the earth end of the arrester, the attached lead must have adequate length to allow it to create a gap between the bottom of the arrester and the disconnected half of the device. The flexibility of the lead also needs to be considered to insure that the device can create the aforementioned gap. Typically bus bar will cause a disconnecting problem, and ordinary flexible lead is adequate. Solid or stranded conductors with diameters up to 1 cm are generally easily disconnected from the arrester on typical devices. When arresters are mounted on a cross arm in parallel to each other, it is important that the arrester in the middle not have its earth lead bound in place by the two outside units. This can lead to a sustained outage even though the disconnector did activate and attempt to isolate the arrester. NOT Recommended Recommended Figure 5 Recommended Lead Management for 3 phase parallel connection Copyright ArresterWorks 2008 Jonathan J. Woodworth Page5

Transportation and Disposal Due to the fact that arrester disconnectors contain an activation element that is capable of exploding and separating the ground lead when exposed to the heat of ground fault current, it is also capable of operating the same way put in a fire. Therefore disposal should not include incineration. According to Model UN regulations of dangerous materials, the GLD should fall into a Class 1 Explosive material. However with appropriate testing or modification to the GLD it can be re-classified to a different classification. If the GLD is manufactured in such a way that it will not create a projectile if caught in a fire during transportation, it can be classified as a non-dangerous goods and transportation is not an issue. See a paper presented at the 2007 INMR World Conference titled Emerging Transportation Issue with Distribution Arresters for more information about the transportation issue. This does raise the question of how to safely transport all arresters on trucks. It is suggested that the end arrester be carried in a metal enclosed chamber routinely found on utility trucks. If that is not possible, wire the GLD end of the arrester to something substantial or to its own high voltage end. have had higher current TLD tests as part of their certification process. The Future Disconnector Future Possibilities for Disconnectors 1. Interrupting Disconnector: This device does not exist at the moment, but is one that should be seriously considered by arrester manufacturers. It could eliminate a blink on the power system in the event of an overloaded and failed arrester. 2. Substation Disconnector: This is a device that could be mounted on higher voltage devices that could be used to disconnect this type of arrester as it does for distribution arresters. 3. Very Visible Disconnectors: Often times line personnel over look a failed arrester because the arrester disconnector in the disconnected mode is not obvious. Some sort of waving flag should be added to the designs of disconnectors. Disconnectors use on Transmission Line Arresters This disconnector has the same function as a distribution disconnector but does have to withstand different stresses without operation. It is important to note that any disconnector used in this application should Copyright ArresterWorks 2008 Jonathan J. Woodworth Page6

ArresterFacts Usage Arrester Facts are Copyrighted documents intended for the education of arrester users and stakeholders. If you choose to copy any part of this document for teaching purposes you have my permission, however please give ArresterWorks proper credit. Thank you for using www.arresterworks.com as your source of information on high voltage surge arresters. Jonathan Woodworth Principal Consultant ArresterWorks May 2008