NetSure ITM. Contents 1. Site Planning Data 2. One Line Diagram 3. System Outline Drawings 4. Connection Details

Similar documents
Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

MAJORSINE Power Inverter

StatiVolt. Inverter UPS Systems. Features. Contents

TOSHIBA International Corp

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Power Processor - Series 700F 10KVA to 150KVA

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Installation requirements

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Gutor PxW AC UPS Designed for North American Market

C-Band Redundant LNA Systems

200 Watt Passive Shunt Module

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA

System Components and Accessories

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

R&D TECHNICAL SPECIFI

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

X-Band Redundant LNA Systems

Technical Data Sheets

AUM FAMILY Programmable DC Power Supplies

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

G-NET. 1 kva-10 kva. Rack & Tower UPS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

TECHNICAL DATA SHEET B9600FXS kva

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

Electrical Specifications

MS-CEFB Filter Box. Installation Guide

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

AC POWER SYSTEMS CATALOG

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Electrical Specifications

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

LCE-MBP-400. User Manual. TDI Transistor Devices Inc. 85 Horsehill Road, Cedar Knolls, NJ USA Phone: Fax:

8 Input/8 Output AC Block I/O Module

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

XMU+ Environmental, Safety and Specifications

Table G. INPUT/OUTPUT Ratings & External Wiring Requirements for the /160 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

This Chapter contains:

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

POWER. CPS250-M Series. 250 Watt AC-DC Power Supplies. Data Sheet. Total Power: 250 Watts Input Voltage: V # of Outputs: Single

PEC 1015C PEC1015R Rectifier System Amp 19 MTG Amp 23 MTG Amp 30 MTG

02/11/2015

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

MONITORED PRO econnect TM PDU

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Liebert THE NEW LEADER IN THREE-PHASE UPS PRODUCT. Npower. 30 to 130 kva. True Double Conversion. Exceptional Reliability. Unmatched Performance

Power IT LV Active Filters PQFA - PQFL - PQFT

Datawave Magnetic Synthesizer

in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT

Beyond AMI. We Put You in Control When It Counts

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Technical Instructions Document No EA GQD June 23, OpenAir

RoHS APPROVAL SHEET. ituner 12V/5A SERIES NO. (05) EA10523C-120 CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0

Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

SECTION PANELBOARDS

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

24V dc Analog Block I/O Module

Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Electrical Specifications

A6500-UM Universal Measurement Card

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

USER MANUAL XLB-650 Short Arc Xenon Lamp Ballast

Electrical Specifications

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

APPROVAL SHEET 12V/2A EA1019HHUS(03) EA1019HHUS-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

MONITORED econnect TM PDU

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

50W Constant Current (700mA) Dimming LED Driver

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

PowerFlex 400 Submittal

USER MANUAL. CW Diode Driver Power Supplies

Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS ULTRA CORE PLUS

Transcription:

A technical manual from the experts in Business-Critical Continuity NetSure ITM Site Planning Data and System Drawings 48V DC UPS Section 6037 (Issue 10, October 21, 2010) Contents 1. Site Planning Data 2. One Line Diagram 3. System Outline Drawings 4. Connection Details

Section 6037 Issue 10, October 20, 2010 Emerson Network Power NetSure ITM 1 SITE PLANNING DATA 1.1 Technical Specifications NetSure ITM Technical Specifications Primary Module 1 Expansion Module 2 Expansion Module 3 Expansion Module 4 Power Rating (full) kw 70 70 70 70 Power Rating (N + 1) kw 64 70 70 70 AC Input Specifications Phase 3 Power Factor 0.99 at full load, 0.98 at 50% load Frequency Hz 45-65 Input Voltage Nominal 400 / 480V, 3 wire + ground Input Voltage Range 304-530 VAC; shall withstand up to 600 VAC input without damage. Input Breaker Rating / AIC Rating A 150 / 65,000 Max Input Current / Module 480V: 115A @ 384V; 92A @ 480V 400V: 138A @ 320V; 110A @ 400V 380V: 145A @ 304V; 116A @ 380V Inrush Current Inrush current does not exceed 150% of the rated input steady state peak value Total Harmonic Distortion <5% from 50-100% of load DC Output Specifications Voltage Nominal: -48VDC; normal operation: -54.5 VDC (battery float) Range: -42 to -58 VDC System Efficiency 92.5% peak (system level including branch distribution losses) Energy Optimization Mode: Intelligent Power Matching Allows operation at near-peak efficiency down to 5% overall load Branch Distribution Options 22 circuit breakers, 100-200A each; optional: 6 fuses, 2x500A + 4x200A Specification Type VRLA, Emerson Excellence EB4, 200 Ah Arrangement 3 strings; eight 6V blocks per string Backup Time See backup time table at various loads Design Life 15 years @ 20 C ; 10 years @ 25 C Recharge Time (to 97% of nominal capacity) Less than 3 hours for > 35% load; Less than 4 hours > 15% load Physical Data Form Factor Rack Installed Dimensions (H x W x D) in. (mm) 83 x 24 x 41 (2100 x 600 x 1040) Installed Weight lb. (kg) 3214 (1458) Environmental Specifications System Operating Temp. F ( C) -5 C to +35 C; recommended operation with battery: 20 C to 25 C air inlet System Storage Temp. F ( C) -40 to 158 F (-40 C to +70 C) Relative Humidity 0 to 95%, non condensing Operating Elevation ft. (m) 6562 (2000) at full power Audible Noise < 60dB Heat Rejection at Full Load BTU/hr. (kw) 18,096 (5.3) per module EMI FCC class A Safety Certifications Agency Approved CE Marked to EN 60 950-1:2006 UL Listed to 60 950-1 + UL 1801; CSA certified Monitoring Capability Standard Web-based monitoring, alarm reporting via SNMP, and integration with SiteScan via SiteLink-E module Optional Energy Master Remote Supervision Page 2 Proprietary Information

Emerson Network Power Section 6037 NetSure ITM Issue 10, October 20, 2010 1.2 Run Times Back-up Time (minutes) Load Single module Two modules Three modules Four modules 70kW 140kW 210kW 280kW 10kW 130 300 480 630 20kW 55 130 210 300 30kW 28 90 130 180 40kW 17 55 90 130 50kW 12 41 70 100 64kW 7 24 50 75 70kW 3 21 43 69 80kW 17 34 55 90kW 14 27 47 100kW 12 22 40 110kW 10 19 34 120kW 8 17 28 134kW 6 16 25 140kW 3 14 22 150kW 12 19 160kW 10 17 170kW 9 15 180kW 8 14 190kW 7 13 204kW 4 11 210kW 2 10 220kW 9 230kW 9 240kW 8 250kW 7 260kW 6 274kW 3 280kW 1 Proprietary Information Page 3

Section 6037 Issue 10, October 20, 2010 Emerson Network Power NetSure ITM 2 ONE LINE DIAGRAM AC Input A AC Input B (Optional) AC Circuit Breakers (Note 3) PRIMARY DC UPS MODULE (1) AC Input A AC Input B (Optional) AC Circuit Breakers (Note 3) Internal COM-link EXPANSION DC UPS MODULES (2-4) Controller and Communication Controller and Communication Current Transformer Current Transformer PCU Breakers (Note 4) PCU Breakers (Note 4) PCU PCU PCU PCU PCU PCU LVD Shunts Fuse LVD Shunts Fuse Load Shunts Internal DC-link Load Shunts Load Breakers or Optional Fuses Load Breakers or Optional Fuses NOTES 1. DUAL AC INPUT VERSION OPTIONAL. 2. RECOMMENDED INPUT WIRE SIZE 2/0 AWG, 90 C (194 F), SEE NEC TABLE 310.16. 3. MAX INPUT CURRENT: 480V: 115A @ 384V; 92A @ 480V 400V: 138A @ 320V; 110A @ 400V 380V: 145A @ 304V; 116A @ 380V 3. SYSTEM AC INPUT BREAKER(S) RATED 150A, 65kAIC. 4. PCU AC INPUT BREAKERS RATED 32A, 5000AIC. TWO (2) PER BREAKER. Page 4 Proprietary Information

Emerson Network Power Section 6037 NetSure ITM Issue 10, October 20, 2010 3 SYSTEM OUTLINE DRAWINGS 3.1 Mechanical Installation and Outline Drawings 3.1.1 Individual Cabinet Mechanical Data DC UPS MODULE WITH BOTTOM FEED DC DISTRIBUTION DC UPS MODULE WITH TOP FEED DC DISTRIBUTION 41.34 (1050) 26.38 (670) CG Conduits for AC Inputs DC Power System 41.34 (1050) 26.38 (670) CG DC Power System Conduits for AC Inputs 11.81 (300) 23.62 (600) Top View 11.81 (300) 23.62 (600) Top View 84.33 (2142) top cabled CENTER OF GRAVITY Top Cabled Version X = 11.81 (300) Y = 26.38 (670) Z = 36.61 (930) 84.72 (2152) bottom cabled 40.55 (1030) (Bottom cabled) CG CG (top cabled) Z Y X Bottom Cabled Version X = 11.81 (300) Y = 26.38 (670) Z = 40.55 (1030) 36.61 (930) Notes: 1. Dimensions are in inches (millimeters). 2. Weight (fully loaded): 3240 lbs / 1470 kg. 3. Heat Rejection: 18096 BTU/h at full load (per module) 4. May be installed on concrete slab or raised floor. 11.81 (300) Front View 3.1.2 System Configurations. Single Module 70kW (full) 64kW (n+1) Two Modules 140kW (full) 134kW (n+1) Three Modules 210kW (full) 204kW (n+1) Four Modules 280kW (full) 274kW (n+1) System can be expanded either to the left or the right of the Primary Module. Proprietary Information Page 5

Section 6037 Issue 10, October 20, 2010 Emerson Network Power NetSure ITM 3.1.3 Main Components 3.1.3.1 Bottom Cabled Configuration - Circuit Breaker Load Distribution (Standard) AC Input Conduit PCU* Position #1 Feeds PCU Position (left to right) #1/#2, #3/#4, #5/#6, #7/#8, #9/#10, #11/#12 Internal Circuit Breakers (32A) (Each Circuit Breaker Feeds Two ) PCU* Position #2 #3 #5 #7 #9 #11 #4 #6 #8 #10 #12 * (12 x 5833W) SM-AC (AC Input Monitoring) AC Input Circuit Breaker(s) (150A, 65kAIC) ACU+ (Controller) LVD Contactor Fuses (800A) ( leads factory connected and routed to.) 1 11 12 22 Load Distribution Devices (DC distribution circuit breakers, 22 positions, 100-200A) (Fuse Option Available) Return and Load Return ( return leads factory connected and routed to.) Front View (door removed) Page 6 Proprietary Information

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY. Emerson Network Power Section 6037 NetSure ITM Issue 10, October 20, 2010 3.1.3.2 Top Cabled Configuration - Circuit Breaker Load Distribution (Standard) AC Input Conduit Openings Return and Load Return ( return leads factory connected and routed to.) 1 11 Load Distribution Devices (DC distribution circuit breakers, 22 positions, 100-200A) (Fuse Option Available) 12 22 AC Input Circuit Breaker(s) (150A, 65kAIC) PCU* Position #1 ACU+ (Controller) Feeds PCU Position (left to right) #1/#2, #3/#4, #5/#6, #7/#8, #9/#10, #11/#12 Internal Circuit Breakers (32A) (Each Circuit Breaker Feeds Two ) SM-AC (AC Input Monitoring) PCU* Position #2 #3 #5 #7 #9 #11 #4 #6 #8 #10 #12 * (12 x 5833W) Fuses (800A) ( leads factory connected and routed to.) LVD Contactor Front View (door removed) Proprietary Information Page 7

Section 6037 Issue 10, October 20, 2010 Emerson Network Power NetSure ITM 3.1.4 Bottom Cable Entry Conduits for AC Inputs DC Power System Notes: 1. Dimensions are in inches (millimeters). 2. Do not block air intake openings. 3. Minimum under floor space for underfloor output cable runs: A = 1f (300mm). 4. Run cables not to block air openings for battery cooling. Top Cold Aisle Hot Aisle Air Flow BFU Distr. Note 2 Distr. 35.43 (900) Front 17.72 (450) 8.86 (225) 9.84 (250) 8.86 (225) Optional Floor 9.84 (250) Opening for Cooling Side View Raised Floor A Support Stand ½ (12mm) Floor Anchoring Bolts (4 places) 19.68 (500) P/N 547822 24 Tall Floor Stand P/N 547823 36 Tall Floor Stand Page 8 Proprietary Information

Emerson Network Power Section 6037 NetSure ITM Issue 10, October 20, 2010 3.1.5 Top Cable Entry Cold Aisle Hot Aisle DC Power System Openings for Output Cables Distr. Distr. AC Input Conduit Openings Top Air Flow BFU Side View Concrete Floor (slab) Cable Tray Note 2 Front Cable Run Cable Tray Supports if Mounted on Top of Module 35.43 (900) Front View Air Exchange (keep clear) ½ (12mm) Floor Anchoring Bolts (4 places) 19.68 (500) Notes: 1. Dimensions are in inches (millimeters). 2. Do not block air intake openings. Cable Tray Top View 23.62 (600) Openings for Output Cables Proprietary Information Page 9

Section 6037 Issue 10, October 20, 2010 Emerson Network Power NetSure ITM 4 CONNECTON DETAILS 4.1 Bottom Cable Entry Electrical Connection Detail INPUT AC CONDUIT(S) SEE DETAIL E CABINET GROUNDING SUITABLE CABLE LUGS WITH HOLE DIA 3/8" (M10) TYPICAL LUG THOMAS & BETTS TYPE 54136 RECOMMENDED TORQUE 407-434 in-lbs (46-49 Nm). DETAIL B (Circuit Breaker Option) 1 SUITABLE CABLE LUGS WITH HOLE DIA 3/8" (M10) TYPICAL LUG THOMAS & BETTS TYPE 54109 RECOMMENDED TORQUE 407-434 in-lbs (46-49 Nm) INPUT AC CONNECTION SEE DETAIL A CONTROLLER SEE DETAIL D DETAIL C (Circuit Breaker Option) 1" INPUT GROUNDING CONNECTION LUGS 5/16" (M8) TYPICAL LUG THOMAS & BETTS TYPE 54109 RECOMMENDED TORQUE 204-221 in-lbs (23-25 Nm) NEGATIVE BUSBAR SEE DETAIL C (LOAD) POSITIVE BUSBAR SEE DETAIL B (RETURN) SUITABLE CABLE LUGS WITH HOLE DIA 3/8" (M10) TYPICAL LUG THOMAS & BETTS TYPE 54209 RECOMMENDED TORQUE 407-434 in-lbs (46-49 Nm) INPUT AC CABLE ROUTING DETAIL A SIDE PLATES ARE ONLY DELIVERED ON MAIN CABINET. SHALL BE MOVED TO THE LAST EXTENSION CABINET IN A ROW DETAIL B (Fuse Option) factory wiring ONE OR TWO AC CIRCUIT BREAKERS, NO LUGS NEEDED. MARK CABLES A-L1, A-L2 AND A-L3 (B-L1, B-L2, B-L3) RECOMMENDED TORQUE 124 in-lbs (14 Nm) 1.75" 1.75" GND Stud L1 L2 L3 L1 L2 L3 AC IN A AC IN B GND Stud DETAIL D DETAIL E 2" SUITABLE CABLE LUGS WITH HOLE DIA 1/2" (M12) TYPICAL LUG THOMAS & BETTS TYPE 54282 (350kcmil) R E C OM M E N D E D T OR QU E 690-743 in-lbs (78-84 Nm) DETAIL C (Fuse Option) USB ESC ENT RJ45 USB RECOMMENDED COUPLING: RACO TYPE 2628 (GRAINGER 3LV08) OR THOMAS BETTS TYPE TK126US 1.75" 1.5 COMMUNICATION LINKS BETWEEN CABINETS: 1. RS-485 BUS WIRES (TWISTED YELLOW/WHITE WIRES) SHALL BE CONNECTED TO SM-AC. 2. CAN-BUS WIRES (TWISTED BLACK/WHITE WIRES) SHALL BE INTERCONNECTED. 3. CONTACTOR CONTROL CABLES SHALL BE INTERCONNECTED. NOTE 1. WHEN CONNECTING OUTPUT DISTRIBUTION CABLES START WHITH INNER ROW FIRST. SUITABLE CABLE LUGS WITH HOLE DIA 1/2" (M12) TYPICAL LUG THOMAS & BETTS TYPE 54282 (350kcmil) R E C OM M E N D E D T OR QU E 690-743 in-lbs (78-84 Nm) Page 10 Proprietary Information

Emerson Network Power Section 6037 NetSure ITM Issue 10, October 20, 2010 4.2 Top Cable Entry Electrical Connection Detail KNOCKOUTS FOR INPUT AC CONDUIT(S) SIZE 2" OR COUPLING(S) SIZE 2" (NOT INCLUDED) INPUT AC CABLE ROUTING INPUT GROUNDING CONNECTION LUGS 5/16" (M8) TYPICAL LUG THOMAS & BETTS TYPE 54109 RECOMMENDED TORQUE 204-221 in-lbs (23-25 Nm) INPUT AC CONNECTION SEE DETAIL A CABINET GROUNDING SUITABLE CABLE LUGS WITH HOLE DIA 3/8" (M10) TYPICAL LUG THOMAS & BETTS TYPE 54136 RECOMMENDED TORQUE 407-434 in-lbs (46-49 Nm). POSITIVE BUSBAR SEE DETAIL B (RETURN) NEGATIVE BUSBAR SEE DETAIL C (LOAD) DETAIL B (Circuit Breaker Option) 1 SUITABLE CABLE LUGS WITH HOLE DIA 3/8" (M10) TYPICAL LUG THOMAS & BETTS TYPE 54109 RECOMMENDED TORQUE 407-434 in-lbs (46-49 Nm) DETAIL C (Circuit Breaker Option) 1" CONTROLLER SEE DETAIL D SIDE PLATES ARE ONLY DELIVERED ON MAIN CABINET. SHALL BE MOVED TO THE LAST EXTENSION CABINET IN A ROW. SUITABLE CABLE LUGS WITH HOLE DIA 3/8" (M10) TYPICAL LUG THOMAS & BETTS TYPE 54209 RECOMMENDED TORQUE 407-434 in-lbs (46-49 Nm) DETAIL B (Fuse Option) DETAIL A AC IN A L1 L2 L3 AC IN B L1 L2 L3 ONE OR TWO AC CIRCUIT BREAKERS, NO LUGS NEEDED. MARK CABLES A-L1, A-L2 AND A-L3 (B-L1, B-L2, B-L3) RECOMMENDED TORQUE 124 in-lbs (14 Nm) 1.75" GND Stud GND Stud 1.75" factory wiring DETAIL D DETAIL E 2" SUITABLE CABLE LUGS WITH HOLE DIA 1/2" (M12) TYPICAL LUG THOMAS & BETTS TYPE 54282 (350kcmil) R E C OM M E N D E D T OR QU E 690-743 in-lbs (78-84 Nm) DETAIL C (Fuse Option) USB ESC RECOMMENDED COUPLING: RACO TYPE 2628 (GRAINGER 3LV08) OR THOMAS BETTS TYPE TK126US COMMUNICATION LINKS BETWEEN CABINETS: 1. RS-485 BUS WIRES (TWISTED YELLOW/WHITE WIRES) SHALL BE CONNECTED TO SM-AC. 2. CAN-BUS WIRES (TWISTED BLACK/WHITE WIRES) SHALL BE INTERCONNECTED. 3. CONTACTOR CONTROL CABLES SHALL BE INTERCONNECTED. NOTE 1. WHEN CONNECTING OUTPUT DISTRIBUTION CABLES START WITH INNER ROW FIRST. ENT RJ45 USB 1.75" 1.5 SUITABLE CABLE LUGS WITH HOLE DIA 1/2" (M12) TYPICAL LUG THOMAS & BETTS TYPE 54282 (350kcmil) R E C OM M E N D E D T OR QU E 690-743 in-lbs (78-84 Nm) Proprietary Information Page 11

Emerson (NYSE: EMR), based in St. Louis, is a global leader in bringing technology and engineering together to provide innovative solutions for customers in industrial, commercial, and consumer markets through its network power, process management, industrial automation, climate technologies, and appliance and tools businesses. For more information, visit: Emerson.com. Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power, precision cooling, embedded computing and power, integrated racks and enclosures, power switching and controls, infrastructure management, and connectivity. All solutions are supported globally by local Emerson Network Power service technicians. For more information on Emerson Network Power s full suite of solutions specifically supporting the communications network infrastructure, visit: EmersonNetworkPower.com/EnergySystems. Learn more about the NetSure ITM DC UPS from Emerson at: EmersonNetworkPower.com/NetSureITM.. This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. Emerson, Emerson Network Power, Business-Critical Continuity, Efficiency Without Compromise, Albér, EnergyMaster, Liebert, NetSure, SiteScan and SiteWeb are trademarks of Emerson Electric Co. and/or one of its subsidiaries. Emerson Network Power Energy Systems, North America 4350 Weaver Parkway, Warrenville, IL 60555 Toll Free: 800-800-1280 (USA and Canada) Telephone: 440-246-6999 Fax: 440-246-4876 Web: EmersonNetworkPower.com/EnergySystems EnergyNet: Secure.EmersonNetworkPower.com Emerson Network Power. The global leader in enabling Business-Critical Continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.com Racks & Integrated Cabinets Services Surge Protection Code: Section 6037, Issue 10