FLEXUS fx100 AU D I O A N A LY Z E R AUDIO TEST & MEASUREMENT SOLUTIONS. Analog & Digital Audio. Fast Measurements.

Similar documents
Microphone Test System

Design and Production. Analog & Digital Audio. Fast & Accurate Measurements. Scalable Architecture. Superior Specifications.

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

100 dbv to dbv (10 μv to V) for 600 Ω 24 dbu 100 dbv to dbv (10 μv to 6.22 V)

RT-2M Audio Analyzer Measure what you hear...and beyond

Audio & Acoustic. Test & Measurement Solutions. Switzerland

Minirators MR-PRO / MR2

11/19/2013 3:49 PM Page 1 of 26

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

System Two Cascade Plus Audio Test and Measurement System

Agilent U8903A Audio Analyzer

Summary. Output bench. Frequency Response Signal to Noise Ratio Crosstalk, One Channel Undriven Interchannel Phase Input bench.

Dodecahedron Speaker Set

OPERATING MANUAL. Measurement Microphones

Technical Data Measurement Microphones

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

Agilent U8903A Audio Analyzer

OPERATING MANUAL. Measurement Microphones

Audio Analyzer R&S UPV. Up to the limits

Impulse response. Frequency response

Balanced Armature Check (BAC)

USO RESTRITO. Introduction to the Six Basic Audio Measurements. About this Technote. 1: Device Under Test and Signal Path. DUTs

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

Prism Sound dscope Series III. Specifications. 302x245x84mm (2U mounting kit available). Weight:

NTI Minirator MR-PRO Mike Rivers

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

User Guide FFFA

How To... Commission an Installed Sound Environment

NTI Minilyzer Mike Rivers

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

Keysight Technologies M9260A PXIe Audio Analyzer Module

OPERATING MANUAL HANDHELD AUDIO AND ACOUSTIC ANALYZER

Analyzer and Controller SignalCalc. 900 Series. A member of the

User Guide. Version 1.0.

LT-800 Stationary FM Transmitter

ATS-2 Audio Test and Measurement System

FM DISTRIBUTION FOR MOTORWAYS AND TUNNELS

2014 Short Form Test and Measurement Catalog

AX6220Z/AX6240Z. Energy-Efficient, DSP-Powered and Ethernet/USB-Controlled 1000/900-Watt 70/100 V High-Impedance Power Amplifier.

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Appendix G - Specifications. G Specifications. Appendix G - Specifications ANALOG SIGNAL OUTPUTS. Low Distortion Sine Wave. Frequency Accuracy

AUTOMATIC MIXER AX-1OOOA

What you Need: Exel Acoustic Set with XL2 Analyzer M4260 Measurement Microphone Minirator MR-PRO

Appendix D - Specifications. D Specifications. Appendix D - Specifications ANALOG SIGNAL OUTPUTS. Low Distortion Sine Wave

Audio Measurement System For Analog & Digital Analysis

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

Model Owner s Manual. Active 3-Way Studio Monitor System.

BSWA Impedance Tube Solutions

Specifications. Analog analyzers. Inputs. Measurement functions. 16 Audio Analyzer UPL. RMS value, selective

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

User Guide. Version 1.0.

Audio Analyzer R&S UPV. Preliminary Specifications

LT-800 Stationary Transmitter

Audio Analyzers UP 300/UP 350

At What Price Fidelity? A Comparison of Transfer Quality in Audio Analog- to- Digital Converters

Advanced Test Equipment Rentals ATEC (2832)

DSP AMPLIFIERS DI

2026Q CDMA/GSM Interferer MultiSource Generator

User Guide FFFA

1510A PRECISION SIGNAL SIMULATOR

2. Avoid metal objects coming into contact with this product. Protect the solder joints on the bottom of the PCB when mounting this product.

n CLIO 12, by Audiomatica, is the newest measurement software for the CLIO System. The CLIO System is capable of measuring: n electrical networks n

FREEDOM Communications System Analyzer R8600 DATA SHEET

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Agilent U8903A Audio Analyzer

klippel qc system 100% end-of-line testing

24-Bit, ks/s Dynamic Signal Acquisition and Generation

Warning: Power amplifier contain high voltages of several hundred volts. Setup errors can easily damage your health or your equipment.

CALRAD 25 series - potentiometers

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

USER MANUAL. GOLDMUND TELOS 590 NextGen Integrated Amplifier

FREEDOM Communications System Analyzer R8100 DATA SHEET

CALRAD MINIATURE MULTI-CLICK DUAL CONTROLS 40 STEP P.C. MOUNT 11

CMA-100. Counter Measures Amplifier. Owner s Guide

FREEDOM Communications System Analyzer R8100 DATA SHEET

R3132/3162. Advanced Test Equipment Rentals ATEC (2832) R3132 : 9kHz to 3GHz R3162 : 9kHz to 8GHz

FREEDOM Communications System Analyzer R8000C DATA SHEET

khz to 2.9 GHz Spectrum Analyzer

FFT Spectrum Analyzer

User Guide. Version 1.2.

SP395 SoundPro Audio Integrator Operation Manual (Firmware version 1.32)

FREEDOM Communications System Analyzer R8000C DATA SHEET

CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure:

CinemaConnect Innovative streaming technology for Cinema

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8920A RF Communications Test Set Product Overview

3D Intermodulation Distortion Measurement AN 8

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

DX 48 DX 24 DX 12 D X - S e r i e s

TC-3000C Bluetooth Tester

Arbitrary/Function Waveform Generators 4075B Series

21. Technical Data XL2

MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements

StudioLive MIXER INPUTS.

NAU W Mono Filter-Free Class-D Audio Amplifier

PROFESSIONAL POWER AMP

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

CMA-100. User Manual. Counter Measures Amplifier

Transcription:

AUDIO TEST & MEASUREMENT SOLUTIONS Analog & Digital Audio Fast Measurements Accurate Results Scalable Architecture Superior Specifications FLEXUS FX100 AU D I O A N A LY Z E R FLEXUS fx100 AUDIO ANALYZER ON/OFF Made in Switzerland www.nti-audio.com

At a Glance The FLEXUS FX100 is a professional audio analyzer and generator dedicated to research, design lab, end-of-line testing and service. Scalable Architecture The modular hardware architecture allows customizing the FX100 for two or four parallel channel operation, speaker impedance testing and digital audio measurements. The FLEXUS Audio Analyzer grows with future measurement applications. More Channels Individual input switcher and output switcher modules may extend the audio analyzer to 14 input channels or 14 output channels connected simultaneously. The software suite FX-Control may operate several FX100 in parallel thus offering multiplechannel measurements. Parallel Measurements The FLEXUS Audio Analyzer acquires all measurement functions in parallel. State-of-the art measurement technologies offer fast glide sweeps, detailed stepped sweeps, a continuous meter mode and FFT analysis. Superior Specifications The wide level range from 1 μv to 200 Vp together with a THD+N of typical 108 db offers comprehensive audio and acoustic analysis for research and design lab. Frequency Range 5 Hz - 80 khz and DC The FX100 Audio Analyzer offers a wide frequency range up to 80 khz and simultaneous measurement of the DC voltage. Thus the FX100 provides detailed DC and audio frequency analysis within the same configuration. 02

FX-Control Suite The included FX-Control Suite provides the straight forward access to all audio analyzer features. The software utilizes the advantages of state-of-the-art WPF architecture for today s and future measurement applications. Fast Setup The flexible architecture supports all demands for intuitive setup of single, parallel or sequential measurement. Individual configuration and result panels may be displayed at various work sheets. Hardware Diagram The FX-Control software may illustrate the external hardware wiring. This ensures fast setup by sending the project configuration to the production lines around the globe. Sequence Mode Individual measurements may be combined to test sequences, including tolerance handling and Pass/Fail result, creating an easy operator test flow. 03

End-OF-Line Testing The design of the FX100 Audio Analyzer follows the key requirements for end-of-line testing: Flexibility, speed and ease of integration. Flexibility The scalable hardware concept allows customization of the FX100 hardware according to the individual requirements. Plugin options offer full flexibility such as additional measuring channels, input and output switchers or impedance measurement modules. The audio analyzer grows with the application for manually-operated and fully-automated production lines. Measurement Speed Fast glide sweeps obtain all relevant measurement results from one short stimulus, typically less than a second. The FX100 has been optimized for factory noise immunity and high volume production. The sequence mode provides automated measurement of customized test sequences including Pass/Fail decision. 04

Ease of Integration The FX100 Audio Analyzer bridges the demands of QC engineering for using the same instrument in R&D, sample inspection and on the production floor. Individual application projects may be transferred around the globe for fast setup. PureSound Speaker Measurement (optional) Leading-edge measurement technology unveils the speaker parameters including Rub&Buzz with one single stimulus. The patented PureSound technology provides a complete speaker characterization with an unmatched correlation to the human hearing. Two speakers may be measured at the same time! PureSound includes the turnkey production software. Flexibility Fast Measurements Ease of Integration PureSound Rub&Buzz Automation Automation All measurement data may be logged for detailed manufacturing control. The built-in digital I/O interface connects to peripheral devices, such as a foot switch or a stack light. 05

R&D Measurements Fast Multi-Channel FFT The high-resolution FFT with 192 khz sampling rate presents a detailed analysis of the audio frequency spectrum. FFT graph panels may be customized showing one or more traces in the same panel simultaneously. Sweep Measurements Detailed R&D measurements are supported with Frequency, Amplitude, Time and Table Sweeps, which may trigger with internal or external signals. Application Programming.Net The FX-Control Suite software supports all.net programming languages, such as C#.NET and Visual Basic.NET. These offer fast and easy integration into customized production solutions. 06

SPECIFICATIONS ACCESSORIES Analog Generator Test Signals Level Range Level Accuracy Level Flatness Frequency Range THD+N Analog Analyzer Measurement Functions Sweeps GlideSweep Level Range Level Accuracy Level Flatness Frequency Range THD+N Filters Crosstalk Sine, StepSweep, GlideSweep, White Noise 10 μv to 12.45 V ( 100 dbv to 21.9 dbv) ±0.04 db < ±0.01 db (10 Hz to 20 khz) 5 Hz to 80 khz 104 db @ 1 khz, 0 dbv (typical) 101 db + 0.8 μv (BW 22 khz) Level (selective & wideband), Frequency, FFT, Gain, THD, THD+N, Harmonics k2 to k35, Interchannel Phase, Crosstalk, Signal latency, DCV differential, DCV common high or low, DCR optional: PureSound Rub&Buzz Frequency Sweep, Time Sweep, Level Sweep, Table Sweep 100 ms to 40 s < 1.0 μv to 141 V (max 200 Vp), channel independent auto ranging ±0.04 db @ 1 khz < ±0.015 db (20 Hz to 20 khz) DC, 5 Hz to 80 khz 104 db + 0.5 μv @ 1 khz, 0 dbv (typical) 104 db + 0.5 μv (22 khz BW) Lowpass 3.4 khz, 8 khz, 15 khz, 20 khz, 22.4 khz, 40 khz Highpass 10 Hz, 22.4 Hz, 100 Hz, 300 Hz, 400 Hz A-weighting, C-message 125 db + 1 μv (10 Hz to 20 khz) Input Bias Supply 2 VDC, 48 VDC Phantom Power, ICP Digital Audio Interfaces General Channels Extension Slots Interfaces Pass/Fail Result FX-Control Suite Programming Design AES-EBU, S/PDIF and TosLink 2 or 4 in-/outputs with independent signal / level / frequency control XLR and BNC connectors 3 empty slots in FX100 base unit for modular extensions USB 2.0 communication to PC Headphone connector for audio out, 1/4 stereo jack Built-in digital I/O-interface for external peripherals controls Dual-color display with green/red indication PC Software with full access to all audio analyzer features Parallel measurements with internal/external triggering Calculation panels for mathematical processing of measurement data Result reporting: txt-files, csv-files or xlsx-files Full tolerance handling and hardware wiring diagram Supports.NET assembly (e.g. C#.NET, Visual Basic.NET) Desktop use or ½ size 19 rack mounting, 3 rack units high M2010 / M2015 Measurement microphone with class 1 frequency response ORDER INFORMATION Base Unit NTi Audio # Flexus FX100 Audio Analyzer (2 Channel) including FX-Control Suite Software Modular Extensions for Base Unit 600 060 000 Channel Extension (extends to 4 individual input/output channels) 600 060 010 Input Switcher FX-IS (offers 4 additional input channels) 600 060 013 Output Switcher FX-OS (offers 4 additional output channels) 600 060 016 Speaker Impedance FX-SIL (for testing 2 speakers < 2 W simultaneously) 600 060 019 Speaker Impedance FX-SIH (for testing one speaker > 2 Watt @ 8 Ohm) 600 060 021 Digital Audio FX-AES (offers AES-EBU, S/PDIF and TosLink interface) 600 060 024 Accessories Power Amplifier FA400 with fixed +6 db gain PureSound Detecting all audible Rub&Buzz of two speakers in parallel PureSound for Rub&Buzz Detection including Turnkey Production Software 830 000 200 M2010, 1/2 Measurement Microphone, 24-145 dbspl 600 040 010 M2015, 1/2 Measurement Microphone, 34-155 dbspl 600 040 015 Power Amplifier FA400 (2 channel) 600 061 000 19 Rack Mounting for one or two FX100 600 061 005/6 Get full specifications at www.nti-audio.com/fx100 07

AUDIO TEST & MEASUREMENT SOLUTIONS NTi Audio AG Im alten Riet 102 9494 Schaan NTI Americas Inc. P.O. Box 231027 Tigard, Oregon NTI China Room 701, Ganglong Lisheng Mansion, No. 60 NTI Japan Ryogokusakamoto Bldg. 1-8-4 Ryogoku Sales Support Liechtenstein / Europe Phone: +423 239 60 60 97281, United States Phone: +1 503 684 7050 Suli Road, Suzhou Phone: +86 512 6802 0075 130-0026 Sumida-ku, Tokyo Phone: +81 3 3634 6110 Consultancy Fax: +423 239 60 89 info@nti-audio.com Fax: +1 503 684 7051 americas@nti-audio.com Fax: +86 512 6802 0097 china@nti-audio.com Fax: +81 3 3634 6160 japan@nti-audio.com Repairs Calibration All information is subject to change without notice. FLEXUS, FX100, FX-Control and PureSound are trademarks of NTi Audio. ICP is a registered trademark of PCB Piezotronics. Made in Switzerland www.nti-audio.com dth xxxe - 10.12