60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES

Similar documents
ULTRA-K Series 600K - he

Power Processor - Series 700F 10KVA to 150KVA

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

Power-Sure 700. Technical Data TD158001EN. Contents

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

Phoenix DX Clean Power (18 Pulse) AC Drive

PRODUCT FEATURES TYPICAL APPLICATIONS

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

TOSHIBA International Corp

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Est Triplen Power Distribution Unit TPDU kVA

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Minimizing Plant Interruption Caused by Line Disturbances Using Active Voltage Conditioners

B9000 FXS kVA B9600 FXS kVA

Power Conditioners product guide

Active Harmonic Filter

SECTION AUTOMATIC TRANSFER SWITCH

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

POWER QUALITY PRODUCTS FOR NON-LINEAR LOADS

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

StatiVolt. Inverter UPS Systems. Features. Contents

MGETM EPSTM /625/750/800 kva. Three phase UPS

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Power Quality Solutions

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

PowerGard Series C 18-Pulse Enclosed Drive Controllers

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

AF91 Adjustable Frequency Drives Series B

S11 Adjustable Speed Drive Engineering Specification

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

Power Protection and Conditioning

Harmonic mitigating transformers. Energy savings through harmonic mitigation

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

ARF461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY PD-94588C. Description ARF

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

Harmonic mitigating transformers. Energy savings through harmonic mitigation

+Vin. Input Return. +Vin. Input Return

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

User-selectable output bus voltages for optimized voltage/current matching to load requirements.

Strategies for design 600V large modular UPS for critical power applications

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

VF-nC1 Adjustable Speed Drive Engineering Specification

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Power Quality Basics. Presented by. Scott Peele PE

Understanding Noise Cut Transformers

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

OPTIMIZING MAINS IMPEDANCE: REAL WORLD EXAMPLES by Judith M. Russell Consulting Electrical Engineer PowerLines

Est Static Frequency Converter. SFX 10kVA - 10MVA

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

American Power Design, Inc.

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

American Power Design, Inc.

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

MAJORSINE Power Inverter

E N G I N E E R I N G M A N U A L

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

Gutor PxW AC UPS Designed for North American Market

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

FDM Medium Voltage Controller

Power Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron

INTREPID Model 336 Digital Microwave Link

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

POWER LINE IMPEDANCE STABLIZATION NETWORK (LISN) MODEL PLISN-25/2. 5 khz 1 GHz

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

SECTION PANELBOARDS

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

UPS Uninterruptible Power System

AF28461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY PD Description

Phase Matrix, Inc. 545B 548B. Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters. Instruments You Can Count On

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Transcription:

60K(i) - 260K(i) THREE PHASE SureImage IMAGING & TREATMENT SERIES Power Conditioner MODEL ULTRA-K/M THREE PHASE ISOLATION TRANSFORMER Power Processor MODEL 700F/M THREE PHASE VOLTAGE REGULATOR, WITH ISOLATION Seismic-Rated Models Available! OSHPD Seismic Preapproval (OSP) CBC 2013 IBC 2015 Designed specifically to provide voltage regulation, isolation, and power distribution for medical imaging diagnostics / treatment equipment. Superior protection against voltage spikes, sags and surges. Applications: MRI CT PET Molecular Imaging X-Ray Cardiology Linear Accelerator Simulator UL 1012 (Model 700F/M) UL 1561 (Model Ultra-K/M)

MEDICAL-GRADE POWER QUALITY Controlled Power Company engineers and manufactures the industry s highest quality electrical power solutions, capitalizing on 40 years of expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance of our products. The SureImage Power Conditioner (Model Ultra-K/M) and the SureImage Power Processor (Model 700F/M) are the ideal power quality solutions for medical imaging and treatment systems. The voltage regulation, isolation, and performance characteristics of the SureImage Power Conditioner and Power Processor products offer significant advantages over competing products. Both models provide superior load regulation and proven performance that extends the life of your medical equipment. Our Model 700F/M assures steady, regulated-voltage of ±2%. Medical-Grade Power Quality for Imaging and Treatment Systems Power quality refers to all electrical environment issues that affect the performance and reliability of electronics-based equipment, systems, and networks prevalent in hospitals and imaging / treatment centers. These issues include grounding and bonding, electrical wiring, electrical disturbances (outages, brownouts, surges, voltage spikes, harmonics, and high-frequency electrical noise), and radiated emissions (EMI, RFI, and ESD). Industry experts believe that as many as 75% of electronics-based equipment disruptions and failures are attributed to power quality issues. Think about it: what would it mean to a hospital or imaging / treatment center, if 7 out of 10 equipment problems were prevented? If power quality is affecting equipment performance, it s costing money! K(i) Rated For Increased Surge Capability and High Efficiency A K(i) rating refers to the intermittent kva or momentary power demand rating. When performing an imaging scan or treatment procedure, most medical equipment has a high inrush current meaning that the current will rise 3 to 5 times the steady state current, or higher! SureImage medical K(i) rated power conditioners and voltage regulators are designed to supply this demand, while continuing to provide tightly-regulated voltage. Most manufacturers of standard transformers, power conditioners, and voltage regulators over-size their units to regulate voltage well under these dynamic load conditions. This approach results in increased operating costs, a more expensive installation, and typically a larger unit footprint. Other manufacturers over-size their units to prevent automatic bypassing, misinterpreting this normal operation as a system overload. Such an approach results in exposing critical medical equipment to unregulated, unconditioned power. In contrast, the SureImage products are sized properly for the continuous load rating, providing high efficiency and lower operating costs. In addition, all models are surge-rated to optimize performance, providing your medical equipment with exactly the power it needs. Optional Power Metering and Data Logging Standard Features: Real-time voltage, current, power, and energy measurements. Real-time remote monitoring. Programmable out-of-limit alarms. MODBUS RS485 communications. 3-line, bright LED display. IrDA port for PDA remote read. Options: MODBUS TCP Ethernet connection. Integrated web server for real-time monitoring. Real-time waveform viewing. Power quality harmonic recording. Contact closure outputs. Power quality metering with waveform capture. Local event logging. 2 Copyright March 2018. Controlled Power Company.

TYPICAL INPUT POWER REQUIREMENTS Healthcare engineers, responsible for meeting the electrical needs of medical imaging and treatment equipment, must look closely at the OEM specified maximum allowable input voltage requirements. While the high line and low line limits may be stated at ±10%, this does not reflect the stability or regulation of the line voltage that must be met during equipment operation. OEM s will specify the source impedance and other ratings, all of which point to a minimum variation in voltage when going from the steady state to maximum current draw of their equipment. Even more stringent, is the typical maximum phase imbalance specification of 2%. Still other OEM s specify line voltage regulation of ±5% or less! So, is voltage regulation important? The answer is YES! The SureImage Power Conditioner (Model Ultra-K/M) enables OEM and site engineers to meet and exceed the minimum recommended power requirements and provide additional power quality. For the optimum medical imaging / treatment power quality solution, the SureImage Power Processor (Model 700F/M) is recommended. Power Elements Typical OEM Power Requirements Oversized Ultra-K/M 700F/M Distribution Transformer Line Voltage Regulation Sags no more than 8% 10% below nominal. Surges no more than 8% 10% above nominal. Load Regulation Size of facility transformer and feeder wires determine load regulation to the system. Total load regulation must not exceed 6%. Common Mode & Transverse Mode Noise When the primary is exposed to a 6000 V, 3000 A (Cat. B) waveform, the secondary output increases 330 V peak, maximum. Phase Imbalance Resulting from utility / generator line voltage imbalance. Resulting from step load change or load imbalance. The difference between the highest line-to-line voltage and the lowest line-to-line voltage must not exceed 2%. Transient Voltage Limits the maximum transient voltage to 1500 V, peak. Note: Power requirements stated are typical minimum OEM requirements. Modality-specific power requirements must be verified with medical equipment manufacturer. Product Specifications for Both the Ultra-K/M and 700F/M Low Output Impedance: 2% typical Phase Imbalance: <2% typical Electrostatic Shielding: Triple shielded Reflected Harmonics: Load-generated triplen harmonics not reflected to input source Model 700F/M Line Voltage Regulation: ±2% Meets ANSI / IEEE C62.41 cat B-3 surge capability See our Ultra-K/M and 700F/M webpages for detailed specifications, or consult factory for application assistance. 3

MODEL SELECTION GUIDE PERFECT FIT FOR IMAGING & TREATMENT EQUIPMENT Image Quality Is By Design... Not By Accident One inclination is to try to meet the power quality needs of medical imaging and treatment equipment by simply wiring to an existing upstream distribution transformer. Even if care is taken to not exceed the maximum allowable feeder (voltage) regulation, poor power quality can still exist. Power disturbances such as high frequency voltage spikes, transients, and line voltage sags and surges must be eliminated. It is critical to take control of the electrical environment, making bad power a non-issue. Poor Power Quality Often Translates Into: Distribution Transformer Artifacts in the digital image. Random error codes, and system lock-ups. Costly repeat scans. Unexplained system faults or restarts. Unscheduled downtime, and expensive emergency repairs. Significant Benefits of Installing the Ultra-K/M Power Conditioner Near the Imaging / Treatment Equipment: Isolation, superior step load voltage regulation, re-established N-G bond, and attenuation of voltage spikes result in: Significant reduction / elimination of artifacts in the digital image. Enhanced workflow and processing time. Preventing premature failure of imaging / treatment equipment. Lower cost to maintain imaging / treatment equipment. As well as: Reduced installation expenses. Higher power efficiency, and lower operating costs. Optimum Benefit of Installing the 700F/M Power Processor: Tight line voltage regulation, combined with all the benefits of the Ultra-K/M Power Conditioner, result in: Highest level of image quality and diagnostic reliability. Optimum workflow and patient satisfaction. Removal of voltage sags and surges associated with system restarts. Compensation for generator power voltage drops during scans. Ultimate component and system reliability. Permanent location or portable (optional casters). 4

SUREIMAGE MODEL ULTRA-K/M POWER CONDITIONER Ultra-K/M Additional Product Specifications Output Load Regulation: 2% from typical steady state load to intermittent power demand Voltage Compensation Taps: Full capacity taps at 2.5% increments, 2 FCAN and 4 FCBN (Exception: 225K(i) at 208 VAC or 240 VAC input taps at 5% increments, 1 FCAN and 2 FCBN) K-Factor Rating: K13 Output Impedance: 2% typical at 50% of rated load Common Mode Noise Attenuation: 146 db Transverse Mode Noise Attenuation: 3 db down at 10 KHz, 40 db down per decade Standard Surge Protection Device (SPD): Secondary-connected, 40kA per mode; with high frequency filter, status indicator Optional SPD, 100kA per phase, UL 1449 Listed; with EMI/RFI filtering, form C rely contacts, LED status indicators Optional main input / output CB provided in separate NEMA1 enclosure for external mounting and installation Optional high / over temperature alarm contacts for customer s hardwired connection Optional IR window(s) for safe routine thermal scanning of transformer connections under load Meets and exceeds the U.S. Department of Energy (DOE) 2016 Minimum Efficiency Standard, and complies with the Canadian Energy Efficiency Standard C802.2-12. Model Ultra-K/M (i) Model Ultra-K/M 112.5K(i) 70K 60K 40K 10K < 5 seconds Ultra-K/M (i) Typical MRI Power Profile (0.35T) Typical CT or PET Power Profile 112.5K 90K 80K 70K 25K Ultra-K/M 112.5K(i) Typical PET Power Profile MODEL INPUT * OUTPUT ** INPUT BTU S / DIMS. WEIGHT VOLTAGE VOLTAGE BREAKER HR 8B*X-(i)HE-K/M 208V L = 175A 8C*X-(i)HE-K/M 240V 208V/120V 150A 8D*X-(i)HE-K/M 480V N = 70A 8E*X-(i)HE-K/M 600V 480V/277V 60A 28 W 4,600 25 D 700 lbs 39 H MODEL INPUT * OUTPUT ** INPUT BTU S / DIMS. WEIGHT VOLTAGE VOLTAGE BREAKER HR 8B*X-112.5K(i)HE-K/M 208V L = 300A 8C*X-112.5K(i)HE-K/M 240V 208V/120V 250A 8D*X-112.5K(i)HE-K/M 480V N = 125A 8E*X-112.5K(i)HE-K/M 600V 480V/277V 100A 28 W 7,650 25 D 830 lbs 39 H Model Ultra-K/M 1(i) Model Ultra-K/M 225K(i) 1 90K Ultra-K/M 1(i) Typical PET Power Profile 225K 160K 1 < 5 seconds max. < 5 minutes Ultra-K/M 225K(i) Typical MRI Power Profile MODEL INPUT * OUTPUT ** INPUT BTU S / DIMS. WEIGHT VOLTAGE VOLTAGE BREAKER HR 8B*X-1(i)HE-K/M 208V L = 300A 8C*X-1(i)HE-K/M 240V 208V/120V 250A 8D*X-1(i)HE-K/M 480V N = 125A 8E*X-1(i)HE-K/M 600V 480V/277V 100A 28 W 7,650 25 D 830 lbs 39 H MODEL INPUT * OUTPUT ** INPUT BTU S / DIMS. WEIGHT VOLTAGE VOLTAGE BREAKER HR 8B*X-225K(i)HE-K/M 208V L = 400A 8C*X-225K(i)HE-K/M 240V 208V/120V 350A 8D*X-225K(i)HE-K/M 480V N = 175A 8E*X-225K(i)HE-K/M 600V 480V/277V 150A 38 W 11,500 32 D 1,210 lbs 57 H Notes: Stated BTU s / Hr is at rated load, 100% duty cycle. Operational BTU s / Hr is typical at 50% of rated load. ** Input breaker provided by others. Intermittent KVA ratings are shown for a duration of 15 seconds, repeated use at 10% duty cycle. Time durations shown are not to scale, and are for illustration purposes only. See Back Cover for Maximum Continuous kva rating of each Ultra-K/M model. 5

SUREIMAGE MODEL 700F/M POWER PROCESSOR 700F/M Additional Product Specifications Output Line Voltage Regulation: ± 2% Output Load Regulation: < 2% from typical steady state load to intermittent power demand K-Factor Rating: K13 design for power profiles illustrated below Output Impedance: 2% typical at rated load Common Mode Noise Attenuation: 146 db Transverse Mode Noise Attenuation: 3 db down at 1 KHz, 40 db down per decade Efficiency: 97% typical at full load, continuous rating Internal regulator bypass Standard Surge Protection Device (SPD): Secondary-connected, 40kA per mode; with high frequency filter, status indicator Optional SPD, 100kA per phase, UL 1449 Listed; with LED status indicators Optional input and output digital metering Optional output circuit breakers (up to 2) Model 700F/M 60K(i) Model 700F/M (i) 70K 60K 40K 10K 700F/M 60K(i) Typical MRI Power Profile (0.35T) Typical CT or PET Power Profile 80K 70K 60K 40K 700F/M (i) Oncology Linear Accelerator Power Profile 8B*X-60K(i)-7F/M 208V 110A 8C*X-60K(i)-7F/M 240V L = 208V/120V 100A 3,069 8D*X-60K(i)-7F/M 480V N = 480V/277V 50A 8E*X-60K(i)-7F/M 600V 40A 8B*X-(i)-7F/M 208V 200A 8C*X-(i)-7F/M 240V L = 208V/120V 175A 8D*X-(i)-7F/M 480V N = 480V/277V 80A 5,115 8E*X-(i)-7F/M 600V 70A Model 700F/M (i) Model 700F/M 160K(i) 110K 90K 10K 700F/M (i) Typical PET Power Profile 160K 1 1.500K 0.1 seconds < 2 minutes 5 minutes max. 700F/M 160K(i) Typical Angiography Power Profile 8B*X-(i)-7F/M 208V 200A 8C*X-(i)-7F/M 240V L = 208V/120V 175A 8D*X-(i)-7F/M 480V N = 480V/277V 80A 5,115 8E*X-(i)-7F/M 600V 70A 8B*X-160K(i)-7F/M 208V 300A 8C*X-160K(i)-7F/M 240V L = 208V/120V 250A 8D*X-160K(i)-7F/M 480V N = 480V/277V 125A 7,673 8E*X-160K(i)-7F/M 600V 100A Notes: Stated BTU s / Hr is at rated load, 100% duty cycle. Operational BTU s / Hr is typical at 50% of rated load. Intermittent KVA ratings are shown for a duration of 15 seconds, repeated use at 10% duty cycle. Time durations shown are not to scale, and are for illustration purposes only. See Back Cover for Maximum Continuous kva rating of each 700F/M model. 6

SUREIMAGE MODEL 700F/M POWER PROCESSOR Model 700F/M 210K(i) Model 700F/M 260K(i) 210K 160K 1 <.003 seconds < 5 seconds < 5 seconds < 5 minutes < 5 minutes 260K 180K 1 125K < 6 seconds CT & PET simultaneously < 80 seconds 700F/M 210K(i) Typical MRI Power Profile, OEM 1 Typical MRI Power Profile, OEM 2 700F/M 260K(i) Typical CT & PET Power Profile Typical Dual Generator CT Power Profile 8B*X-210K(i)-7F/M 208V 400A 8C*X-210K(i)-7F/M 240V N = 480V/277V 350A 8D*X-210K(i)-7F/M 480V 175A 10,230 8E*X-210K(i)-7F/M 600V 150A 8B*X-260K(i)-7F/M 208V 500A 8C*X-260K(i)-7F/M 240V N = 480V/277V 400A 8D*X-260K(i)-7F/M 480V 200A 12,788 8E*X-260K(i)-7F/M 600V 175A Notes: Stated BTU s / Hr is at rated load, 100% duty cycle. Operational BTU s / Hr is typical at 50% of rated load. Intermittent KVA ratings are shown for a duration of 15 seconds, repeated use at 10% duty cycle. Time durations shown are not to scale, and are for illustration purposes only. See Back Cover for Maximum Continuous kva rating of each 700F/M model. Note: Seismic-rated units with an input nominal voltage of 208VAC, 240VAC, or 480VAC are designed and tested in accordance with applicable portions of the following standards: OSHPD Special Seismic Certification Preapproval (OSP) ICC - AC156: Acceptance Criteria for Seismic Certification by Shake-Table Testing of Nonstructural Components and Systems California Building Code CBC 2013 International Building Code IBC 2015 Seismic unit provided on floor mounting channels. Unit weight and dimensions are the same as the standard unit. Advantages of Front Access 700F/M DIMENSION AND WEIGHTS K(i) RATING DIMENSIONS (IN INCHES) WEIGHT 60K(i) 29 W x 24 D x 59 H 890 lbs (i) 29 W x 36 D x 66 H 1,176 lbs (i) 29 W x 36 D x 66 H 1,176 lbs 160K(i) 34.5 W x 36 D x 76 H 1,575 lbs 210K(i) 34.5 W x 36 D x 76 H 2,014 lbs 260K(i) 34.5 W x 36 D x 76 H 2,398 lbs Top Entry for Input / Output Power Connections Optional Input and Output Meters Optional Output Circuit Breakers to Protect Customer Equipment Status Lights and Alarm Indication Regulator Bypass Switch Note: System isolation transformer remains online when in the bypass mode, providing voltage transformation and power conditioning. Main Input Circuit Breaker for Overload Protection No Right, Left, or Rear Access Required for System Operation or Service Front Access to Regulator Controls and Components if Service Required Bottom Entry for Input / Output Power Connections 7

SureImage Output Power Ratings The matrices below list the Intermittent kva and the Maximum Continuous kva for each SureImage Ultra-K/M and 700F/M model. Refer to the power profile illustrations on Pages 5 (Ultra-K/M) and 6 7 (700F/M) to see how each model accommodates the steady state and momentary (intermittent) power demand of medical imaging and treatment equipment. ULTRA-K/M MODEL INTERMITTENT KVA MAXIMUM CONTINUOUS KVA (i) 75 45 112.5K(i) 112.5 75 1(i) 150 75 225K(i) 225 112.5 700F/M MODEL INTERMITTENT KVA MAXIMUM CONTINUOUS KVA 60K(i) 60 30 (i) 75 50 (i) 100 50 160K(i) 160 75 210K(i) 210 100 260K(i) 260 125 WARRANTIES: Controlled Power Company warrants the Model Ultra-K/M transformer (core and coil) to be free from defects in material and workmanship for a period of 1 year full, and an additional 24 years prorated. All other unit components are covered by a 2 year full replacement warranty. These warranty periods begin following the original factory ship date. Controlled Power Company warrants the Model 700F/M to be free from defects in material and workmanship for a period of 1 year. This warranty period begins following the original factory ship date. Represented by: 1955 Stephenson Hwy., Troy MI 48083 www.controlledpwr.com email: info@controlledpwr.com Phone: (800) 521-4792 Fax: (248) 528-0411 All information and data within this brochure is subject to change without notice. Copyright October 2017. Controlled Power Company. SureImage-005-0318