DLA-E (Philips EvoKit) The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit.

Similar documents
DLA Adapter INSTALLATION INSTRUCTIONS PRODUCT SAFETY GETTING STARTED

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

ETC Installation Guide

General Installation Instructions LED

Installing and Upgrading Internal Modules in Cisco 1800 Series Routers (Modular)

TH Place, Maspeth, NY Instruction Manual for UNO Exit Signs

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Connecting the Channel A

Installation Instructions

SHINE CB / OW5513 CB / OW 5515 CB / OW 5517 CB / OW 5524

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

End of Row Doors. Revision Number 1

Custom Pendant- Hardwire Assembly and Installation Instructions

F l a t S c r e e n A R M S I n s t a l l a t i o n

Hawko Zhaga Systems Installation Instructions

Installation and Operation Manual. Ajustable Valance Kits CAUTION: Duke Manufacturing Co.

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

Fan, Eden/Northfield, GS Installation Instructions (SKU ) Packing List

Lightplane 3.5 Recessed

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Installation Guide. SN-LM42 Brilliance Series Photoluminescent Area of Rescue Signs

TOYOTA COROLLA EC REARVIEW MIRROR Section I Installation Preparation

Sentinel Electronic Safe Installation Guide

Installation Instructions

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

INSTALLATION INSTRUCTIONS

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

KNOB LATCH. Specifications: Glass-To-Wall Installation CAT NO. LAT001 C.R. LAURENCE CO., INC. PROFESSIONAL QUALITY

Bolt-On/Rugged Fender Flares Chevy CK PICKUP (88-98) Please read instructions entirely before installing this product.

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CONTOURED LIGHT BAR APPLICATION: CHEVY EQUINOX/ GMC TERRAIN PART NUMBERS: ,

HOLLY HUNT LIGHTING. STUDIO H EDGE CHANDELIER Installation Instructions

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

MALEKO WALL-MOUNT FAUCET INSTALLATION

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

Installation Instructions

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4" Flush Canopy Version

Footer & Base Plate Assembly. installation guide. ILINE power/data beam

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

2009 Acura TL Installation Instructions

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

I NSTALLATION M ANUAL

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

INSTALLATION INSTRUCTIONS

ETC Installation Guide

ASSEMBLY AND INSTALLATION INSTRUCTIONS

IMPORTANT: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

INSTALLATION INSTRUCTION Solorail - Low Voltage Starter Kit

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

Kai Installation Instructions

ADVANTUS CV1100 SERIES OV1100 SERIES OG1000 SERIES

Assembly Instructions. Important!

Jeep Wrangler JK & 4-Door Front Pair Part # Revision H

OPERATOR ADAPTER A21ABVA

INSTALLATION INSTRUCTIONS

BLUEMOTION UXP, CDP, SD

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

Installation Guide Philips IntelliVue MP20/30/40/50/60/70 MX400/450/500/550/600/700/800 M-Series Arm Mounting Kit for Dräger Primus Anesthesia Machine

Healthcare LED TROFFER FLANGE (HSTLED Family)

RPMSP Series Installation Guide

Installation Instructions

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

Installation Instructions

HO4 Surface Mount Installation Instructions Overview

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

Electro-Mech Scoreboard Co. Product Guide

Height Adjustable Benching End Panel and Utility Pole

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

MPA-9000 Universal Ceiling Projector Mount Kit

Pow-R-Feed Systems Service Manual

Installation Instructions

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Frameless Inline Door QCI5248

Mounting a BalanceBox 400 to a brick wall

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

ETC Installation Guide

INSTALLATION MANUAL PBC-UMS

INSTALLATION AND CARE INSTRUCTIONS

RAMPAGE P R O D U C T S. INSTALLATION INSTRUCTIONS BRONCO ZIPPER FASTRACK TOP PART #984xx BRONCO TOOLS REQUIRED

Transcription:

DA Sensor INSTAATION INSTRUCTIONS PRODUCT SAFETY! Digital ight Agent (DA) hardware must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. To avoid risk of electrical shock, disconnect power before installing, wiring, or servicing DA hardware.! Do not use fixture or DA hardware if the housing, sensor optic or wires are damaged.! Do not apply paint, lubricants or other coatings to the DA housing.! Use a dry cloth to clean the DA housing and sensor optic. GETTING STARTED OVERVIEW The DA system transforms fixtures from third-party manufacturers into an intelligent light with high-performance sensors, power metering, full-range dimming, and software optimization capabilities. There are two categories of DA components: DA sensors and DA adapters. DA sensors measure occupancy and ambient light. They also control connected fixtures through a direct link with Philips SR (Sensor Ready) drivers, DAI drivers, or through 0-10 V adapters (for older 0-10 V ED drivers). DA sensors communicate wirelessly with the ightrules system to receive commands and send data. DA adapters measure fixture power consumption. They also convert the digital commands from DA sensors into an analog 0-10 V signal for use with 0-10 V dimming ED drivers. Note that this document covers DA sensors. Please refer to the DA Adapter Installation Instructions for adapter setup. SENSOR TYPES DA-R (Recessed Mount) Use the DA-R when you want to blend the sensor into an environment by mounting flush to a junction box or a ceiling tile. DA-E (Philips EvoKit) The DA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit. DA-S (Surface Mount) Featuring an IP65 rating, use the DA-S in challenging environments. DA-S mounts to a ceiling surface or NEMA 4 or weatherproof junction box. DA-I (Integrated Mount) The DA-I mounts directly to into any third-party fixture the housing mounts inside and the lens assembly extends externally. HEPFU HINTS Install the DA sensor in a manner so as to provide a clear field of view for the lens. Do not mount the DA sensor within 5 ft (1.5 m) of an air vent. Consult the DA specification sheets for detail regarding mounting heights and occupancy sensor coverage patterns.

Step One: Install DA Hardware DA-R Installation 1.9 in 4.7 cm 1 4.6 in 11.6 cm 3.5 in 8.9 cm METHOD ONE: CEIING TIE INSTAATION a. Review the DA-R dimensional drawings, above. Mounting Plate c. Remove the plastic bezel. Hint: Place your thumb on the notch in the bezel and pull away to release. d. Using the metal mounting plate as a template, trace the inner profile and the screw holes and then cut the ceiling tile using an appropriate saw. e. Insert the sensor housing up through the hole in the ceiling tile, place the mounting plate on the back of the ceiling tile around the sensor housing, and then secure using the (2x) supplied Phillips screws. Note: Place the flat side of the collar against the tile. f. Replace the bezel. g. Make power and data connections (see Step Two on page 6). Bezel Ceiling Tile Mount METHOD TWO: 4-INCH ROUND JUNCTION BOX INSTAATION a. Review the DA-R dimensional drawings, above. c. Remove the plastic bezel. Hint: Place your thumb on the notch in the bezel and pull away to release. d. Discard the metal mounting plate. e. Make power and data connections (see Step Two on page 6). f. Insert the sensor housing into the junction box and then secure using the (2x) supplied Philips screws. g. Replace the bezel. Junction Box Mount 2 DA SENSOR INSTAATION INSTRUCTIONS

Step One: Install DA Hardware, cont. DA-E Installation 1.9 in 4.7 cm 3.3 in 8.3 cm 3.0 in 7.6 cm STANDARD INSTAATION METHOD a. Remove and put aside the extra serial number label. b. Make power and data connections (see Step Two on page 7). c. Insert the sensor housing up through the existing cutout in the Philips EvoKit SR fixture. d. Slide the sensor housing sideways until it snaps into place. e. Install the Philips EvoKit SR fixture as per the manufacturer s instructions. Finished Assembly DIGITA UMENS 3

Step One: Install DA Hardware DA-S Installation 2.1 in 5.3 cm 4.9 in 12.4 cm 3.5 in 8.9 cm Important Note The DA-S is IP65-rated and designed for use in damp or wet environments. Ensure that the included mounting gasket is intact before installation. METHOD ONE: CEIING INSTAATION a. Review the DA-S dimensional drawings, above. c. Remove the plastic bezel. Hint: Squeeze the two flat areas on the edge of the bezel and pull away to release. d. Cut a.5 in (7 mm) or greater hole in the ceiling panel and run the power and data wires through the opening. Ceiling Mount e. Make power and data connections (see Step Two on page 8). f. Secure the housing using suitable fasteners (supplied by installer). g. Replace the bezel. METHOD TWO: 4-INCH IP65 JUNCTION BOX INSTAATION a. Review the DA-S dimensional drawings, above c. Remove the plastic bezel. Hint: Squeeze the two flat areas on the edge of the bezel and pull away to release. Junction Box Mount d. Make power and data connections (see Step Two on page 6). e. Secure the housing to an IP65 round NEMA 4 or weatherproof enclosure using the (2x) supplied Philips screws. f. Replace the bezel. 4 DA SENSOR INSTAATION INSTRUCTIONS

Step One: Install DA Hardware, cont. DA-I Installation 2.44 in 6.2 cm 1.6 in 4.0 cm.9 in 2.3 cm.9 in 2.3 cm Important Note 2.44 in 6.2 cm The DA-I is designed to install within a third-party fixture housing, with the sensor optic extending externally. Be sure to install the gasket and hex nut in the correct order, as shown to the right. STANDARD INSTAATION METHOD a. Review the DA-I dimensional drawings, above. Fixture 1 1.3 to 1.4 in 3.3 to 3.6 cm c. Detach the lens assembly by turning it counter-clockwise. d. Remove the hex nut. e. The DA-I requires a 1 in trade-size knockout (1.3 to 1.4 in / 3.3 to 3.6 cm hole) for proper mounting and sealing. f. Install the DA-I module inside the fixture housing, with the threaded nipple extending outside the fixture housing through the opening created in the previous step. g. Secure the housing using the supplied hex nut. Tighten the hex nut. h. Re-connect the lens assembly, turning it clockwise the lens assembly stops rotating. i. Make power and data connections (see Step Two on page 6). j. Install the third-party fixture as per the manufacturer s instructions. Gasket Hex Nut.125 in 3.18 mm Maximum DIGITA UMENS 5

Step Two: Make Power and Data Connections DA-R, DA-S and DA-R Wiring Examples (DA-R shown) DA-R, DA-S or DA-I DAI Wiring N DAI Bus Supply (Third Party) DAI + (Yellow/) N DAI ED Driver (Third Party) DAI + (Yellow/) DC () DC + (Red) (To EDs) Connect with up to three (3x) additional DAI drivers Note: Use 18 to 22 AWG (0.82 to 0.33 mm 2 ) wiring DA-R, DA-S or DA-I Philips SR Wiring N Philips Xitanium SR ED Driver DAI + (Yellow/) DC () DC + (Red) (to EDs) Connect with up to three (3x) additional drivers Note: Use 18 to 22 AWG (0.82 to 0.33 mm 2 ) wiring DA-R, DA-S or DA-I 0-10 VDC Wiring Red DA-FA or DA-CA DAI + (Yellow/) 0-10 VDC + (Purple) 0-10 VDC (Gray) Connect with up to three (3x) additional DA adapters Switched ine Note: Use 18 to 22 AWG (0.82 to 0.33 mm 2 ) wiring 0-10 VDC Dimmable ED Driver Out + - DC () DC + (Red) (to EDs) 6 DA SENSOR INSTAATION INSTRUCTIONS

Step Two: Make Power and Data Connections, cont. DA-E Wiring Example Philips EvoKit SR Wiring DA-E N Philips Xitanium SR ED Driver DAI + (Yellow/) DC () DC + (Red) (To EDs) Note: Use 18 to 22 AWG (0.82 to 0.33 mm 2 ) wiring DIGITA UMENS 7

Step Three: Update the Sticker Book Guidelines Each DA comes with an extra metallic serial number label. It is critical that you adhere the label to the sticker book, which represents the facility s floor plan. Place the label in the box that corresponds to the relative location of the DA within the facility. Note that without an accurate and complete sticker book, the facility s lighting management software cannot be programmed and the installation process may be delayed. The project manager will provide access to the sticker book. Blank page from a sticker book created using a CAD program Step Four: Verify DA Hardware ocate Heartbeat Once the fully installed DA unit, including adapter and sensor, is powered ON, you can verify that the equipment is receiving power by locating the DA heartbeat. ook at the sensor lens: Every 30 seconds, you should see a blinking red ED indicator. Heartbeat Indicator Note that until the DA unit is programmed using Commissioner software, the DA unit will use the following settings, which effectively tell the connected light fixture(s) to remain ON at 100%, with no occupancy sensing: Active ight evel: 100% Inactive ight evel: 100% Occupancy Sensor Delay: Sensor Inactive www.digitallumens.com 374 Congress Street, Suite 600 Boston, MA USA 02210 +1 (617) 723-1200 All Rights Reserved 2010-2015 Digital umens Incorporated Subject to change without notice. DOC-000390-00 Rev A 10-15