HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

Similar documents
TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

TT-SI MHz Active Differential Probe

TT-SI MHz DIFFERENTIAL PROBE

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TT-SI 9001 / TT-SI MHz Active Differential Probes

TT-SI MHz Active Differential Probe

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AC/DC CLAMP METER USER S MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

MD 200A High voltage differential probe

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MW3105 DIGITAL CLAMP MULTIMETER

Dawson DDM190. Digital Multimeter User s Manual

Pen-type DIGITAL MULTITESTER

ICM 136R Operating Instruction Electrical Clamp-Multimeter

R/C SMD Tweezers Multimeter Model RC200

30XR-A Professional Digital Multimeter Users Manual

DVM1190 DIGITAL MULTIMETER

LH240 LH1040 LH2040 LH2015

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

AMM-1022 Digital Multimeter USER`S MANUAL

# Digital Multimeter

400 MHz Passive High-Voltage Probe R&S RT-ZH

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

3B SCIENTIFIC PHYSICS

Digital Clamp Meter Model: &

PHV RO High Voltage Passive Probe. Instruction Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

User s Manual Current Probe. IM E 2nd Edition IM E

EC Declaration of Conformity

BENNING. CM7 Electrical Tester. Service Information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

Model DIGITAL MULTIMETER

TA MHz oscilloscope probe TA MHz oscilloscope probe

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

DS1000E, DS1000D Series Digital Oscilloscope

DDM350 Pen-Type Digital Multimeter User s Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

USER'S MANUAL DMR-6700

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Model 77 Series IV. Digital Multimeter. Users Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Tablet Oscilloscope Safety Information

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

DM-45 Digital Multimeter

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS2030 CAT III 600 V A V AUTO RS232

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

LH630 LH635 LH1035. Operating Instructions Mode d emploi Bedienungsanleitung Istruzioni per il funzionamento Instrucciones de Funcionamiento

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MS8223A. CAT.IIi 600 V

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

ProfiScale MULTI Multimeter

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Multifunction Digital

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

OPERATING INSTRUCTION

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

MS2109A AC/DC Clamp Meter. User Manual. Contents

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

TETRIS 1000 High Impedance Active Probe. Instruction Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

9 Specifications. Specifications NOMINAL CHARACTERISTICS

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

200Amp AC Clamp Meter + NCV Model MA250

PKT 512A-RO High Impedance Passive Cable Divider

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

600A Clamp Meters w/tightsight Display

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Operator s Manual. PP016 Passive Probe

OPERATOR S INSTRUCTION MANUAL

80i-110s AC/DC CURRENT PROBE

8110 FUNCTION GENERATOR. Safety Instruction. Safety Symbols

TETRIS User's Guide. High Impedance Active Probe DO177-1

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

CONTENTS MS2033A. 1.Introduction Safety Information...01

DM-46 Instruction Manual

Transcription:

HZ 115 Differential probe for oscilloscopes 1500 V input voltage max. 30 MHz bandwidth x 100 and x 1000 attenuation 50 db CMRR (1MHz) User-friendliness through a microcontroller Automatic Switch-off Beep appears when overrange Low battery indication Battery operation with external supply option C E IEC 1010 Cat III

Contents 1. Safety precautions 2. Items supplied with the probe 3. Introduction to the differential probe 4. Technical features. 5. Using the probe 6. Maintenance and repair 7. Examples of differential probe applications 1.Safety precautions Symbols used The following safety signs are used on the probe and in these instructions: Caution, danger erous volta oltage! Caution, danger! Read instructions! Prior to using the differential probe for the first time, read the following carefully : The probe must only be used by qualified personnel. Earthing the probe : This probe is designed to be Class 1 (connected to a protective conductor) so, apply carefully the following connecting procedure: By means of the BNC output socket, connect the probe to the oscilloscope in order to earth it. It is therefore necessary to check that the oscilloscope itself is connected to earth via a lead which conforms to regulations. Then connect the probe to the oscilloscope, prior to connecting the leads to the item to be tested. It is imperative not to disconnect the probe from the oscilloscope until after the test leads have been disconnected. Use only high quality accessories which conform to safety standards. Never open the probe whilst the input leads are connected. Never exceed the maximum input voltage of 1500 V (DC + AC peak), (IEC 1010-1 Cat. III). When using equipment with a reted of 1000 V CAT III they never exceed the maximum input voltage of 1400 V (DC + AC peak). Do not expose the probe to humidity, steam or an aggressive or explosive environment. Keep the case and the connection leads in a clean condition and prevent humidity or liquid from being able to penetrate inside the probe or its component parts. Do not use the probe if there is any reason to think that it is not operating properly or that it is faulty. The mains power supply must conform to the standards in force. If the probe is not to be used for a prolonged period, remove the battery, so that it will not damage the battery compartment. 2. Items supplied with the probe The differential probe is supplied with the following : 1 Differential probe 1 9 V monobloc battery 6LF22 2 safety test tips 1 operating instructions

3. Introduction to the differntial probe 4. Tec echnical char haracteristics acteristics OUTPUT max. ± 1,5 V Socket for external supply 12 V DC / 30 ma OFF button ON button LED yellow - x 100 red - x 1000 flashes- U batt < 6 V Attenuation switch pressed - x 100 not pressed - x 1000 The srews for opening the probe are located on the rear face. Differential input (Safety leads) DIFFERENTIAL PROBE HZ 115 ON OFF POWER X 100 X1000 1500Vpeak 1500Vpeak max 1500Vpeak Input Differential input voltage max. ± 1500V (DC+AC peak ) Common mode input voltage ± 1500V (DC+AC peak ) to earth. Warning: both above conditions must be respected simultaneously. When using equipment to 1000V ± 1400V (DC+AC peak ) Safety IEC1010-2-031, Insulation: class1 Degree of pollution 2, Indoor use, altitude < 2000m Installation category of input CAT III (*); 1500V max. to earth Operating temperature 0 C to +40 C Storage temperature -10 C to +60 C Relative humidity 80 % RH at 40 C Input impedance 60MΩ 1.5 pf Attenuation x 100 and x 1000 Accuracy after 1 min. ± 3% (18 C - 30 C) I Frequency Bandwidth at x 100 20 MHz Bandwidth at x 1000 30 MHz Rise time at x 100 17.5 nsec Rise time at x 1000 12 nsec Output Output voltage max. ± 1.5 V (1MΩ) Output impedance 50 Ω Noise max. 1.5 mv Common mode rejection ratio DC: 70 db AC: 50dB (at 1 MHz) Supply Battery 9V block Low battery indication LED flashes at U batt < 6 V Optional power supply 12V DC / 35 ma Operating time on one battery approx. 16 hours Battery switch-off automatic, after 10 minutes Accessories 2 safty test tips red and black Dimensions Case (LxWxH) 157 x 60 x 26 mm Weight 300 g with battery Material ABS, internal screening Output cable length 50 cm EMC: This instrument has been designed in conformity with EMC standards in use and the compatibility has been tested regarding the following standards - EN 61326 (IEC 1326). The product herewith complies with the requirements of the low voltage directive 73/23/EEC and the EMC directive 89/336/EEC amended by 93/687EEC. (*) Overvoltage category III is defined as follow: Fixed installation equipment (Examples: Industrial apparatus permanently connected to a fixed installation)

5. Using the probe Befor ore e using the differ erential ential probe for the fir irst st time,, read carefully the section on the precautionary measures es at t the beginning of these instructions uctions. Inserting or replacing the 9 V battery Before using the differential probe for the first time, the battery supplied with the device must be inserted in the battery compartment and connected up by means of the clip. If the LED lamp (battery indicator) flashes during operation, the voltage of the battery has dropped to approximately 6 V. In order to ensure that the probe is operating correctly, it will then be necessary to replace the battery. At the time of inserting or replacing the battery, the input leads must not be connected to an item to be tested! Never operate the probe with the case open. To insert or replace the battery, remove the three screws on the rear face of the case and then open the probe. If necessary, the old 9 V battery can then be removed and insert the new one in the compartment. Always ensure not to damage or move the electronic components, in particular the control device. After inserting the new battery, close the case and tighten the three fastening screws. Usign an external power er supply Using the socket on the side of the probe, it is possible to connect the device to an external power supply. The internal battery is then disconnected and the battery saving automatic switch-off does not operate, indicated by a beep. A mains transformer, for example, can be used for the external power supply. The power supply voltage must lie within the range of 9-16 V DC. The current consumption will be approximately 35 ma. Take into account the fact that the output voltage of some supplies considerably exceeds their nominal value! Only use on external power supply that conforms with all the safety and EMC standards in force.

Connecting the probe Prior to connecting the probe, read the section on the safety precautions at the beginning of these instructions! Connect the output of the probe to the input of the oscilloscope, with the coaxial lead inserted into the BNC socket. The input impedance of the oscilloscope must be 1 MΩ. In view of the high impedance connection it is not advisable to extend the cable considerably. In the case of using an oscilloscope incorporating a 50Ω input, the output voltage of the probe is reduced by half. It should also be taken into account the fact that consumption may also increase. In the case of a low impedance connection, it is possible to extend the cable without difficulty. Use of the safety leads ensures reliable measurements up to a maximum voltage of ±1500V DC + peak AC. Should accessories be used which were not supplied with the probe, it is essential to check that they conform to safety standards! Test est equipment risk assesment Users of this equipment and or their employers are reminded than Health and Safety Legislation require them to carry out a valid risk assesment of all electrical work so as to identify the potential sources of electrical danger and risk of electrical injury such as from inadvertent short circuits. Where the assesment show that the risk is significant then the use of fused test leads constructed in accordance to the HSE guidance note GS38 Electrical Test Equipment for use by Electricians should be used. Switching the probe on and off The probe is switched on by pressing briefly on the ON button. The operating condition is indicated by the LED lamp lighting up and a short beep. Colour of the LED indicats attenuation: yellow - x100, and red - x1000. The device can be switched off by pressing briefly on the OFF button. In order to increase the life of the battery, the device switches itself off automatically after an operating time of 10 minutes. The automatically switch off is independent of the input signal. If the ON button is pressed again before the end of this period, the operating time is again reset to 10 minutes. It is possible, to switch off the automatic shutoff timer by pressing the ON button longer then 1 sec. The automatic shutoff facility is cancelled when an external supply is connected.

Button or operation result beep ON briefly device on 1 x (2 x when ext. supply is indicated) ON briefly, when divice is on auto off reset 1 x ON longer then 1 sec auto off off 2 x external supply on auto off off 2 x external supply off auto off on and reset 1x auto off after 10 min device off 3 x 2 OFF briefly device off 1 x input voltage 150V at x100 continual input voltage 1500V at x1000 continual Choice of atten ttenua uation The probe offers the choice of two attenuation factors : x 100 and x1000. For an attenuation factor of x 100 (selector depressed, LED is lighting yellow), the voltage at the inputs is equal to the voltage displayed on the oscilloscope x 100. For an attenuation factor of x 1000 (selector not depressed, LED is lighting red), the voltage at the inputs is equal to the voltage displayed on the oscilloscope x 1000. Procedur ocedure e for using the differ erential ential probe - Check the mains earth connection to the oscilloscope - Connect the probe to the oscilloscope. - Adjust the vertical sensitivity on the oscilloscope (V/div.). - Select the attenuation factor on the probe (x 100 or x 1000). - Switch the probe ON. - If necessary, adjust the reference line on the oscilloscope. - Connect the test leads to the item to be tested. 6. Maintenance and repair The differential probe does not require any special maintenance. If necessary, clean the case with a damp cloth. Ensure that no moisture enters inside the device. Do not use the probe if there is any reason to think that it is not operating properly or that it is faulty. In the case of repair, send the device to the distributor. Do not attempt to service or repair the probe yourself.

7. Examples of differ erential ential probe applica pplications Ref efer erence ence potential and safety The measuring inputs of a normal mains operated oscilloscope are referenced to mains earth potential because they are connected, via the oscilloscope power cord, to the mains earth. Also, other exposed metal parts of the oscilloscope are connected to earth. Therefore, if an oscilloscope is connected to measure live mains circuits such as switching controllers, thyristors or power MOSFETs then this can cause short circuits damaging the system components and extreme user safety hazards. These safety hazards still exist if the oscilloscope earth is disconnected or if it is powered through a mains isolating transformer because the oscilloscope input and other metal parts will be raised to the test circuit voltage. However, the use of differential probes provides safe single or multi-channel measuring connections. The oscilloscope casing may carry lethal voltages when the ground Iead is detached. Differential probe for safe measurements Apart from the danger which exists when taking measurements with floating potential, further problems arise in multi-channel measurements because ground connections still exist between the oscilloscope inputs. Using a differential probe ensures safety. This probe allows measurements between any two points of a circuit without a reference point. However, since the output is related to ground, it can be easily connected to the input of the earthed oscilloscope.

Earth loop circuits cuits and common mode volta oltages Whilst the ground potential can in principle be used as a common reference point in many cases, it is often impossible to make reference connections to the same common point. This may create earth loops which means that a voltage may build up between the ground potential of the investigated circuit and the ground potential of the oscilloscope. It can be greater than the signal voltage and falsify the measuring result. The use of a differential probe is frequently the only solution in such cases or when a high common-mode voltage is present. Highly accurate measurements largely unaffected by interference voltages can be made thanks to the high degree of common-mode rejection offered by the differential probe and the possibility of tapping the measuring voltage direct at the signal source. Differential probe principle Example: Voltage at the motor series resistor is only a fraction of the common-mode voltage which is superimposed on the measuring voltage. The differential probe expands each oscilloscope input to provide differential input connections for safe measuring on floating potential circuits. The probe also provides rejection of common mode signals.