Agilent 4-Port PNA-L Network Analyzers

Similar documents
Agilent PNA Series RF Network Analyzers

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Agilent E8267C PSG Vector Signal Generator

Agilent PNA Microwave Network Analyzers

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

expanding the possibilities

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent EPM Series Power Meters

Advanced Test Equipment Rentals ATEC (2832)

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 4-Port PNA-L Microwave Network Analyzer

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

Agilent 87415A, 87400A Microwave Amplifiers

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent 8902A Measuring Receiver Product Note

Configuration of PNA-X, NVNA and X parameters

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent E8267C/E8257C/E8247C PSG

Agilent 83440B/C/D High-Speed Lightwave Converters

Product Note E5100A-2

Advanced Test Equipment Rentals ATEC (2832)

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent PNA Microwave Network Analyzers

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent 8902A Measuring Receiver

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent NFA Noise Figure Analyzer

Advanced Test Equipment Rentals ATEC (2832)

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Advanced Test Equipment Rentals ATEC (2832)

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Agilent Technologies 3000 Series Oscilloscopes

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Keysight E5063A ENA Series Network Analyzer

Agilent NFA Noise Figure Analyzer

Agilent 83711B and 83712B Synthesized CW Generators

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Agilent dc Electronic Loads Models N3300A-N3307A

Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent AN Applying Error Correction to Network Analyzer Measurements

Agilent N4373B Lightwave Component Analyzer Testing advanced 40Gb/s components with highest relative and absolute accuracy

Agilent Network Analyzer Selection Guide

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Introduction. Part 1. Introduction...2

Agilent 87075C Multiport Test Set

Agilent MXG Signal Generators

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Agilent 2-Port and 4-Port PNA-X Network Analyzer. N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Introducing ENA Series E5061B-1x5/2x5/1x7/2x7 RF NA Options 100 khz to 1.5 / 3 GHz

Agilent CSA Spectrum Analyzer

6 Tips for Successful Logic Analyzer Probing

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

Agilent E6651A Mobile WiMAX Test Set

Advanced Test Equipment Rentals ATEC (2832)

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Agilent 8761A/B Microwave Switches

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Agilent ENA Series 2, 3 and 4 Port RF Network Analyzers E5070A 300 khz to 3 GHz E5071A 300 khz to 8.5 GHz E5091A Multiport Test Set.

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Base Station Installation and Maintenance

AV3672 Series Vector Network Analyzer

S3602A/B Vector Network Analyzer Datasheet

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

Introduction. Part 1. Introduction...2

Keysight E5063A ENA Vector Network Analyzer

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Agilent NFA Noise Figure Analyzer

Agilent 8752C RF Vector Network Analyzer

!"#$!" Agilent!"#$%&!"#$%&'()*+!"#$%&'(!"#$%&'()*+, -./ !"#$ Agilent!"#$%&'()*+,-./0 !"#$%&'()*+,-./0! !"#$ Agilent!"#$%&'()*+,-.

Agilent MXG Signal Generators

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Agilent Network Analyzer Selection Guide

Agilent E8460A 256-Channel Reed Relay Multiplexer


Keysight E5063A ENA Series Network Analyzer. 100 khz to 500 M/1.5 G/3 G/4.5 G/6.5 G/8.5 G/14 G/18 GHz

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Keysight M9485A PXIe Multiport Vector Network Analyzer

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Transcription:

Agilent 4-Port PNA-L Network Analyzers N5230A Options 240, 245 300 khz to 20 GHz Speed and accuracy you can count on Integrated 4-port, balanced measurements up to 20 GHz

Introducing the 4-port PNA-L network analyzer Speed, accuracy, and features for modern component test Key Features 300 khz to 20 GHz single-ended and balanced measurements High speed measurements less than 4 µs per point 4-port network embedding/de-embedding, differential matching, and port-impedance conversion Advanced calibrations include TRL and Unknown Thru Automatic port extension unique feature to easily compensate for fixture loss and electrical delay Configurable test set for applications such as high power measurements and with more test ports Excellent dynamic range (120 db 1 ) and trace noise (0.006 db rms 2 ) Exceptional accuracy with NIST 3 traceable electronic calibration (ECal) modules (optional) Time-domain analysis and frequency-offset measurements (optional) 2 Configurable test set (optional) for applications such as high power testing and with more test ports 1. At 2 GHz. 2. At 100 khz bandwidth. 3. NIST: National Institute of Standards and Technology. Up to 16 windows and 32 independent measurement channels for easy execution and viewing of complex test setups 2- and 4-port ECal modules (optional) allow you to calibrate up to 30 times faster than mechanical standards-based calibration

Fast measurements improve throughput and reduce cost-of-test Setting a new standard for high-speed measurements New multiport components require complicated test plans. Multiple port combinations must be tested over several frequency bands, resulting in lengthy tests. To reduce test time and lower costs, the 4-port PNA-L has been designed for high-speed measurements. It offers IF bandwidths up to 600 khz, and sweep speeds as low as 4 µs/point. To further simplify complex test requirements, up to 32 independent measurement channels are available, eliminating the need for recalling instrument states. Advanced triggering capabilities allow for easy and fast synchronization with other system components. Additionally, PNA-L s new innovative computation techniques make calculating multiple S-parameters faster than ever. When measurements are complete, results are easily saved, printed or exported to external tools for analysis or documentation via LAN or GPIB interfaces. Maximum speed 4-port PNA-L ENA 8753ES < 0.05 db Peak-to-peak trace noise 4-port PNA-L ENA 8753ES 0 50 100 150 200 250 Measuremet speed (ms) 1 Agilent 8753ES, 4-port PNA-L, and ENA network analyzer comparisons: The 4-port PNA-L s fast measurement speed and low trace noise can dramatically increase throughput. 1. 1 GHz CF, 100 MHz span, 201 points, 2-port cal. 3

Accurate, reliable 4-port measurements up to 20 GHz The need for accurate measurements Component designers and manufacturers are continually challenged to keep up with increasing frequencies and component complexity. Whether for wireless LAN frontend modules or satellite filters, modern component production lines require accurate as well as fast test to stay competitive. Agilent s 4-port PNA-L network analyzer offers the industry s best combination of speed and accuracy to meet these measurement challenges. With low trace noise (0.006 db rms at 100 khz bandwidth) and high dynamic range (up to 120 db at 2 GHz), the PNA-L provides engineers with greater accuracy and repeatability, minimizing measurement uncertainty. Precise, repeatable results Testing at microwave frequencies introduces many challenges compared to RF. Impedance mismatch errors increase, system stability decreases, and very small physical changes can significantly alter test results. Errors that were negligible at RF frequencies, now become significant and may jeopardize the integrity of your results. The 4-port PNA-L was designed to provide consistent, repeatable results over its entire frequency range. A new RF hardware design offers superb resistance to drift over time and during temperature changes. Trace noise has also been reduced to exceptionally low levels, as illustrated below. Even at the full IF bandwidth of 600 khz, trace noise is typically less than 0.013 db rms 1, providing stable measurement results with low uncertainty. 0.04 Trace noise (db) 0.03 0.02 0.01 0-0.01-0.02-0.03-0.04 4-port PNA-L (600 khz IFBW) 4-port PNA-L (7 khz IFBW) 8720ES (6 khz IFBW) 4-0.05-0.06 Agilent 20 GHz 8720ES and PNA-L network analyzer comparison: 2 The 4-port PNA-L offers superb trace noise. 1. 2 GHz measurement frequency, -5 dbm output power. 2. S11 measurement of a short, 950 to 1000 MHz, 201 points, -5 dbm.

Precise calibrations provide confidence Removing calibration complexity Calibration is crucial for accurate measurements. Agilent offers a variety of NIST-traceable electronic calibration (ECal) modules to speed your calibration process. With ECal modules, you can perform fast, repeatable calibrations that are as accurate as a sliding load mechanical calibration, but less error-prone and more than 30 times faster. Two-port ECal modules operating from 300 khz to beyond 20 GHz offer fast and accurate calibration. The PNA-L calibration software allows you to make a full 4-port calibration using a 2-port ECal module with only 4 connections and disconnections (the same as a 4-port module). Port extensions Traditional port extensions allow the user to enter an electrical delay, correcting for the physical length of the test fixture. As test frequencies increase beyond a few GHz, however, the insertion loss of a fixture becomes significant as well. The 4-port PNA-L port extension feature allows a user to input an insertion loss value in addition to electrical delay, allowing for much more accurate fixture compensation. To further simplify fixture compensation, Agilent introduces the innovative Automatic Port Extension feature. With this one-button feature, the 4-port PNA-L automatically measures a fixture s electrical length and insertion loss and applies the correction to measurements, making in-fixture measurements easy and accurate. For even more convenience and time savings, 4-port ECal modules offer one-step calibrations from 300 khz to 20 GHz, satisfying the requirements of a wide variety of component test applications. Simple and easy-to-use, Automatic Port Extension is ideal for in-fixture measurements, especially those with multiple ports ECal enables fast, accurate, repeatable calibrations 30 times faster than mechanical calibration. Embedding and de-embedding The 4-port PNA-L offers full embedding and deembedding of user-supplied S-parameter data files, as well as predefined matching circuit topologies that can be mathematically embedded. Port impedance conversion is available for testing devices that are not 50 ohms. In-fixture measurements Normal coaxial calibrations do not account for the effects of fixtures on measurements, and resulting errors can become quite significant at microwave frequencies. The 4-port PNA-L offers a variety of easy and accurate methods to correct for fixtures. Embedding and de-embedding of 4-port networks, as well as 2-port networks, are available for achieving accurate results 5

Advanced features for R&D and manufacturing Built to improve your efficiency The 4-port PNA-L makes it simple to measure a variety of devices. Easily measure single-ended, balanced, and mixed-mode S-parameters in addition to ratioed and unratioed receiver measurements. For devices with more than four ports, a test set can be added to expand the number of test ports available. Different test sets can be added depending on your measurement needs. Test set control is available in the 4-port PNA-L, no extra external software is needed. Graphical interface makes it easy to set up balanced measurements. The 4-port PNA-L is supported by Agilent's Advanced Design System (ADS), enabling device data to be used in circuit and system simulation. Users can also save 4-port data as.s4p files, which are easily imported into ADS for analysis. Analysis features such as trace statistics and trace math provide insight into device behavior, while mixed-mode measurements such as common-to-differential mode conversion allow you to discover design flaws early in the design process. The 4-port PNA-L can even be used to improve manufacturing throughput when testing 2-port devices. Use the four integrated ports to simultaneously test multiple devices, or test one device while connecting or disconnecting another. Adding a 10-port test set expands the 4-port PNA-L into a 14-port test system. Use Agilent's Physical Layer Test System (PLTS) software to expand the 4-port PNA-L s measurement capabilities for high-speed differential interconnect design and validation. PLTS software combines frequency-domain, time-domain, and eye-diagram analysis to provide a comprehensive view of your physical layer element. It also controls measurement setup and calibration to provide the most accurate measurements for model extraction, characterization, and validation of your designs. Use all 4 ports to eliminate connect/disconnect inefficiencies. 6 Characterize and validate differential channels with a full suite of analysis tools available in PLTS.

Agilent offers a comprehensive portfolio of 4-port solutions Choose the solution that s right for you Agilent s ENA and PNA-L network analyzers and Physical Layer Test Systems (PLTS) provide a variety of 4-port and balanced measurement solutions from 300 khz to 67 GHz to meet your specific application and budget needs. Since all of these products use common calibration and measurement algorithms, you can be sure no matter which Agilent solution you use, you will get the right answer every time. Select a specific frequency range that suits your application needs... Get consistent results with the ENA and PNA-L network analyzers. ENA E5070B Option 414 E5071B Option 414 ENA PNA-L PLTS system PLTS system N5230A Option 240/245 N1958B N1953B PLTS system N1955B PLTS system N1957B PLTS system 300 khz 10 MHz 3 GHz 8.5 GHz 20 GHz 40 GHz 50 GHz 67 GHz Specification summary 4-port ENA RF 4-port PNA-L Physical Layer Test Systems network analyzers network analyzers (PLTS) Maximum frequency 8.5 GHz 20 GHz 67 GHz Measurement speed 9.6 µs/point 4 µs/point 26 µs/point Embedding/de-embedding Port extensions Port extensions Port extensions Auto port extension Impedance conversion Impedance conversion Impedance conversion Defined circuit embed Defined circuit embed S-parameter file S-parameter file S-parameter file embed/de-embed embed/de-embed embed/de-embed Dynamic range (2, 20 GHz) 122 db, n/a 120 db, 103 db Depends on system configuration Maximum power (2, 20 GHz) +10 dbm, n/a +8 dbm, -3 dbm Depends on system configuration Frequency-offset measurements Frequency-offset mode option Frequency-offset mode option Calibration SOLT, TRL, LRM SOLT, TRL, LRM SOLT, TRL, LRM Configurable test set Yes Yes Note: Agilent also offers high-performance 2-port PNA network analyzers. For more information, visit www.agilent.com/find/pna For more information about PLTS, go to www.agilent.com/find/plts 7

PNA-L option descriptions Test set options Standard test set and power range Option 240 Configurable test set and extended power range Option 245 Adds nine front panel access loops and a 60 db step attenuator as shown in the figure below. This provides the capability to add external components for high power measurements, improve instrument sensitivity for measuring low-level signals, or to add other peripheral instruments for a variety of measurement applications. Standard test set Additional options Time domain Option 010 This option enables the PNA Series to view reflection and transmission responses in both time or distance domain. Use time domain to tune filters, gate out the response of fixtures and cables, characterize the impedance of transmission line, and more. Frequency offset Option 080 This option enables the PNA Series to set the source frequency independently from where the receivers are tuned. This ability is important for two general classes of devices: mixers (converters) and amplifiers. Source Switch D C B PORT 4 PORT 3 Certification options Commercial calibration certification with test data Option UK6 Complete set of measurements which tests unit to manufacturer s published specifications. Includes calibration label, calibration certificate, and data report. Conforms to ISO 9001. Reference receiver R A PORT 2 PORT 1 ISO 17025 compliant calibration Option 1A7 Complete set of measurements which tests unit to manufacturer s published specifications. Includes ISO 17025 compliant calibration certificate, label and seals, a full measurement uncertainty report, and a statement of specification compliance. Conforms to ISO 17025 and ISO 9001. Configurable test set and extended power range Source 60 db Reference receiver R Switch D C B A Source out Coupler thru PORT 4 Coupler arm Receiver D in Source out Coupler thru PORT 3 Coupler arm Receiver C in Receiver B in Coupler arm PORT 2 Coupler thru Source out Receiver A in Coupler arm ANSI Z540 compliant calibration Option A6J Complete set of measurements which tests unit to manufacturer s published specifications. Includes pre and post-adjustment data with measurement uncertainty information compliant to the ANSI/NCSL Z540 standard. Agilent also offers a variety of 2-port PNA-L solutions for frequency ranges up to 20, 40, or 50 GHz. For more information visit: www.agilent.com/find/pnal PORT 1 Coupler thru Source out Source out Receiver R in 8

Configuration and ordering information Step 1: Select N5230A model number Step 2: Choose your test set (mandatory, choose only one) Ordering number 300 khz to 20 GHz Standard 4-port test set N52300-240 300 khz to 20 GHz Configurable 4-port test N52300-245 set and extended power range Step 3: Choose additional software options (optional) Ordering number Time domain N52300-010 Frequency-offset measurement N52300-080 Step 4: Choose an electronic or mechanical calibration kit (optional, recommended) Ordering number 300 khz to 26.5 GHz, 2-port ECal module N4691B 3.5 mm connectors 300 khz to 18 GHz, 2-port ECal module N4690B Type-N connectors 300 khz to 20 GHz, 4-port ECal module 3.5 mm connectors N4433A 300 khz to 18 GHz, 4-port ECal module Type-N connectors N4432A 300 khz to 13.5 GHz, 4-port ECal module N4431B 3.5 mm or Type-N connectors For additional options, refer to the Agilent PNA Series Configuration Guide (5988-7989EN) available on our Web site: www.agilent.com/find/pna Step 5: Accessories (Optional) Cables, 3-ft, 3.5 mm (m-f), qnty 4 Cables, 3-ft, 3.5 mm (m-m), qnty 4 Physical layer test system (PLTS) software Node-locked license Server-based/floating license Bundled Productivity Assistance Rack mount kit without handle Rack mount kit with handles USB CD R/W drive USB hub Ordering number N4419A-B20 Z5623A-B20 N1930A N1930A-010 N1930A-020 R1380A-101 N5230A-1CM N5230A-1CP N4688A N4689A Step 6: Calibration documentation (optional) Ordering number ISO 17025 compliant calibration N5230A-1A7 ANSI Z540 compliant calibration N5230A-A6J Commercial calibration certificate with test data N5230A-UK6 Step 7: Choose your warranty and service plan (optional) (standard warranty is 1 year) 1 year return-to-agilent warranty and service 3 year return-to-agilent warranty and service Documentation PNA-L instruments are equipped with an embedded Help system available within the instrument in the following languages: English, Japanese, Chinese, German, Spanish, and French. The PNA Service Guide and embedded Help system are available on the Web: www.na.tm.agilent.com/pna Additional ordering information For detailed information regarding additional measurement accessories and options for the PNA Series, refer to the Agilent PNA Series Configuration Guide available on our Web site: www.agilent.com/find/pna 9

Key specifications Note: For the most current and complete specifications, please refer to the PNA-L Data Sheet available in the "Key Library" section of the PNA-L Web site: www.agilent.com/find/pnal Some definitions Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Typical (typ.): Expected performance of an average unit, which does not include guardbands. It is not covered by the product warranty. System dynamic range 1, 4 Specification Specification at test port at direct receiver access input 2 Dynamic range (10 Hz IF BW) Option 240 Option 245 Option 240 Option 245 300 khz to 10 MHz (111 db typ.) (111 db typ.) N/A (127 db typ.) 10 MHz to 4 GHz 120 db (128 db typ.) 120 db (128 db typ.) N/A 136 db 4 GHz to 6 GHz 118 db (129 db typ.) 118 db (128 db typ.) N/A 134 db 6 GHz to 10.5 GHz 115 db (127 db typ.) 113 db (125 db typ.) N/A 129 db 10.5 GHz to 15 GHz 107 db (119 db typ.) 105 db (117 db typ.) N/A 121 db 15 GHz to 20 GHz 103 db (116 db typ.) 98 db (115 db typ.) N/A 114 db Test port output 3 Option 240 Option 245 Max leveled power 300 khz to 10 MHz +8 dbm (typ.) +8 dbm (typ.) 10 MHz to 4 GHz +8 dbm +8 dbm 4 GHz to 6 GHz +6 dbm +6 dbm 6 GHz to 10.5 GHz +3 dbm +1 dbm 10.5 GHz to 15 GHz 0 dbm -2 dbm 15 GHz to 20 GHz -3 dbm -8 dbm Power range (typ.) 300 khz to 10 MHz -27 to +8 dbm -87 to +8 dbm 10 MHz to 4 GHz -27 to +12 dbm -87 to +11 dbm 4 GHz to 6 GHz -27 to +10 dbm -87 to +9 dbm 6 GHz to 10.5 GHz -27 to +8 dbm -87 to +6 dbm 10.5 GHz to 15 GHz -27 to +5 dbm -87 to +3 dbm 15 GHz to 20 GHz -27 to +2 dbm -87 to -1 dbm Power sweep range 300 khz to 10 MHz 35 db (typ.) 35 db (typ.) 10 MHz to 4 GHz 33 db 33 db 4 GHz to 6 GHz 31 db 31 db 6 GHz to 10.5 GHz 28 db 26 db 10.5 GHz to 15 GHz 25 db 23 db 15 GHz to 20 GHz 22 db 17 db Test port input Option 240 Option 245 Test port noise floor 4 (10 Hz IF bandwidth) 300 khz to 10 MHz < -103 dbm (typ.) < -103 dbm (typ.) 10 MHz to 500 MHz < -112 dbm < -112 dbm 500 MHz to 4 GHz < -112 dbm < -112 dbm 4 GHz to 10.5 GHz < -112 dbm < -112 dbm 10.5 GHz to 15 GHz < -107 dbm < -107 dbm 15 GHz to 20 GHz < -106 dbm < -106 dbm Direct receiver access input noise floor 4 (10 Hz IF bandwidth) 300 khz to 10 MHz N/A < -119 dbm 10 MHz to 500 MHz N/A < -128 dbm 500 MHz to 4 GHz N/A < -128 dbm 4 GHz to 10.5 GHz N/A < -128 dbm 10.5 GHz to 15 GHz N/A < -123 dbm 15 GHz to 20 GHz N/A < -122 dbm Compression level (300 khz to 10 MHz at +5 dbm, 10 MHz to 50 MHz at +8 dbm, 50 MHz to 20 GHz at +10 dbm) 300 khz to 10 MHz 0.1 db 0.1 db 10 MHz to 50 MHz 0.2 db 0.2 db 50 MHz to 1 GHz 0.4 db 0.4 db 1 GHz to 8 GHz 0.3 db 0.3 db 8 GHz to 12.5 GHz 0.4 db 0.4 db 12.5 GHz to 20 GHz 0.5 db 0.5 db 1. The system dynamic range is calculated as the difference between the noise floor and the source maximum output power, and is measured with a 10 Hz IF bandwidth, no averaging applied to data, and an isolation calibration with averaging factor of 8. 2. The direct receiver access input system dynamic range is calculated as the difference between the direct receiver access input noise floor and the source maximum output power. 3. Performance specified on port 1 only; port 2, 3, and 4 performance is a characteristic. 4. Total average (rms) noise power calculated as mean value of a linear magnitude trace expressed in dbm. 10

Option 240 Option 245 Trace noise magnitude (100 khz IFBW, ratioed measurement, nominal power at test port)(typ.) 300 khz to 10 MHz 0.015 db rms 0.030 db rms 10 MHz to 10.5 GHz 0.006 db rms 0.008 db rms 10.5 GHz to 20 GHz 0.010 db rms 0.014 db rms (100 khz IFBW, ratioed measurement, maximum specified power at test port)(typ.) 300 khz to 10 MHz 0.005 db rms 0.010 db rms 10 MHz to 2 GHz 0.001 db rms 0.003 db rms 2 GHz to 10.5 GHz 0.002 db rms 0.003 db rms 10.5 GHz to 20 GHz 0.006 db rms 0.009 db rms Measurement throughput (typ.): Cycle time vs. selected IFBWs Preset configuration, 201 points, CF = 10 GHz, span = 100 MHz, correction = OFF, display = OFF, maximum specified power IFBW (Hz) Cycle time(ms) Trace noise (db rms) 600000 8 0.004 360000 8 0.003 280000 8 0.002 200000 8 0.002 150000 8 0.002 100000 8 0.001 70000 8 0.001 50000 9 <0.001 30000 11 <0.001 20000 15 <0.001 15000 18 <0.001 10000 29 <0.001 7000 37 <0.001 5000 49 <0.001 3000 73 <0.001 1000 219 <0.001 700 294 <0.001 500 400 <0.001 300 636 <0.001 100 1827 <0.001 10 17904 <0.001 Damage input level Option 240, 245 Test port 1, 2, 3, 4 +27 dbm or ± 16 V DC (typ.) Option 245 only Source out (ref) +20 dbm or ± 16 V DC (typ.) Source out (test ports) +27 dbm or ± 16 V DC (typ.) Receiver R, A, B, C, D in +15 dbm or ± 16 V DC (typ.) Coupler thru +27 dbm or ± 16 V DC (typ.) Coupler arm +15 dbm or ± 0 V DC (typ.) Measurement throughput (typ.): Cycle time vs. number of points Preset configuration, CF = 10 GHz, span = 100 MHz, correction = OFF, display = OFF IFBW (Hz) Number of points Cycle time (ms) 600000 11 6.6 600000 51 6.8 600000 101 6.9 600000 201 7.3 600000 401 8.1 600000 801 9.4 600000 1601 12.0 600000 16001 59.3 100000 11 6.6 100000 51 6.8 100000 101 7.0 100000 201 7.5 100000 401 9.0 100000 801 13.5 100000 1601 22.9 100000 16001 180.3 11

Web Resources Visit our Web sites for additional product information and literature. PNA-L Microwave network analyzers www.agilent.com/find/pnal PNA Microwave network analyzers www.agilent.com/find/pna ENA RF network analyzers www.agilent.com/find/ena Physical layer test systems www.agilent.com/find/plts Multiport test soltions www.agilent.com/find/multiport Antenna test www.agilent.com/find/antenna Electronic calibration (ECal) modules www.agilent.com/find/ecal RF and microwave accessories www.agilent.com/find/accessories Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.agilent.com Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. Phone or Fax United States: Korea: (tel) 800 829 4444 (tel) (080) 769 0800 (fax) 800 829 4433 (fax) (080)769 0900 Canada: Latin America: (tel) 877 894 4414 (tel) (305) 269 7500 (fax) 800 746 4866 Taiwan: China: (tel) 0800 047 866 (tel) 800 810 0189 (fax) 0800 286 331 (fax) 800 820 2816 Other Asia Pacific Europe: Countries: (tel) 31 20 547 2111 (tel) (65) 6375 8100 Japan: (fax) (65) 6755 0042 (tel) (81) 426 56 7832 Email: tm_ap@agilent.com (fax) (81) 426 56 7840 Contacts revised: 05/05/05 The complete list is available at: www.agilent.com/find/contactus Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2003, 2004, 2005, 2006 Printed in USA, February 27, 2006 5989-0896EN