PART NUMBER WAVELENGTH INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

Similar documents
PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

RoHS compliant 1310 nm Multi-mode Transceiver (2km) Small Form Pluggable (SFP), 3.3V 155 Mbps ATM/125 Mbps Fast Ethernet. Features.

Features. Ordering Information

RoHS compliant 1550 nm Single-mode Transceiver, 24dB margin Small Form Pluggable (SFP), 3.3V Gbd Fiber Channel/1.25 Gigabit Ethernet.

PART NUMBER TX/RX INPUT/OUTPUT SIGNAL DETECT TEMPERATURE LD

I0AOM nm Single-mode Transceiver, (1000Base-LX) Small Form Pluggable (SFP), 3.3V Gbd Fiber Channel/1.25 Gigabit Ethernet.

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

PART NUMBER TX/RX INPUT/OUTPUT SIGNAL DETECT TEMPERATURE LD

Features. Application

RoHS compliant TX-1550/RX-1310 nm Single-mode Bi-directional SFP SC Simplex Connector (12dB margin) Gbd Fiber Channel/1.25 Gigabit Ethernet

RoHS compliant 850 nm Multi-mode Transceiver Gigabit Interface Converter (GBIC), 3.3V/5V Gbd Fiber Channel/1.25 Gigabit Ethernet.

OP6A-SC0-15-x Datasheet

OP6C-C20-yy-C (1470nm~1610nm) Datasheet

OP6E-C26-yy-CM (1270nm~1450nm) Datasheet

RoHS Compliant 1310 nm Single-mode Transceiver (L1.1) 2 5, LC Duplex Connector, 3.3 V 155 Mbps ATM/SONET OC-3/SDH STM-1/Fast Ethernet

OP6C-M02-13-x Datasheet

RoHS compliant 1310 nm Single-mode Transceiver (L1.1) 1x9, ST Duplex Connector, 3.3 V 155 Mbps ATM/SONET OC-3/SDH STM-1/Fast Ethernet.

RoHS compliant 1310 nm Single-mode Transceiver (S1.1, 19dB margin) 1x9, SC Duplex Connector, 3.3 V 155 Mbps ATM/SONET OC-3/SDH STM-1/Fast Ethernet

1550 nm Single-mode Transceiver (80km) 1 9, SC Duplex Connector, 3.3 V 622 Mbps ATM/SONET OC-12/SDH STM-4

PARAMETER SYMBOL MIN MAX UNITS NOTE

OP6E-W20-B4-xM Datasheet

RoHS compliant 1310 nm Single-mode Transceiver (1000BASE-LX) 2 5, LC Duplex Connector, 3.3 V Gbd Fiber Channel/1.25 Gigabit Ethernet

OP6C-W10-B9-x Datasheet

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, SC Duplex Connector, 5.0 V 155 Mbps ATM/ Fast Ethernet

RoHS compliant 850 nm Multi-mode Transceiver (1000BASE-SX) 2 5, LC Duplex Connector, 3.3 V Gbd Fiber Channel/1.25 Gigabit Ethernet

PROLABS GLC-SX-MM-C 1.25GBd SFP (Small Form Pluggable) Short Wavelength (850nm) Transceiver

ProLabs ZX-SFP-CWDM-XXXX-C 1.25GBd SFP (Small Form Pluggable) CWDM (1470nm 1610nm) Transceiver 23dB Margin

RoHS compliant 1310 nm Single-mode Transceiver (10km) 1 9, ST Duplex Connector, 3.3 V/5V Gbd Fiber Channel/1.25 Gigabit Ethernet

OC-48 SR-1 / STM I16.1 Long wavelength SFP Transceiver RoHS, SFF-8472 Compliant Specification: F414S17413-D

PROLABS GLC-LH-SM-C 1.25GBd SFP (Small Form Pluggable) Long Wavelength (1310nm) Transceiver

ProLabs ZX-SFP-CWDM-XXXX-40KM-C 1.25GBd SFP (Small Form Pluggable) CWDM (1470nm 1610nm) Transceiver 20dB Margin

Features. Ordering Information

1.25GBd SFP (Small Form Pluggable) Long Wavelength (1550nm) Transceiver

PROLABS SFP-10G-LR-C 10GBd SFP+ LR Transceiver

PROLABS GLC-SX-MMD-C 1.25GBd SFP (Small Form Pluggable) Short Wavelength (850nm) Transceiver

PARAMETER SYMBOL MIN MAX UNITS NOTE

PROLABS EX-SFP-10GE-LR-C

ProLabs LX-SFP-1G-C 1.25GBd SFP (Small Form Pluggable) Long Wavelength (1310nm) Transceiver

RoHS compliant 850 nm Multi-mode Transceiver (1000BASE-SX) 1 9, SC Duplex Connector, 3.3 V/5V Gbd Fiber Channel/1.25 Gigabit Ethernet

Multi-Rate up to 2.7G 18 CH CWDM SFP Transceiver RoHS, SFF-8472 Compliant Specification: F419S174XX-D

DATA SHEET: Transceivers

PROLABS DS-SFP-FC8G-LW-C 8GBd Long Wavelength SFP+ Transceiver

PROLABS AJ715A-C 4GBd SFP (Small Form Pluggable) Short Wavelength (850nm) Transceiver

10GBd SFP+ LR Long Wavelength (1310nm) Transceiver

OC-3 IR-1 / STM S1.1 / Fast Ethernet 1310TX/1550RX SC Bi-Di SFP Transceiver RoHS Compliant Specification: F431S11431

2/1x Fiber Channel / Gigabit Ethernet 850 nm SX SFP Transceiver RoHS, SFF-8472 Compliant Specification: MOD-MGSX550-D

DATA SHEET. MODULETEK: SFP10-CWDM-DML-xxxx-20KM-15DB-D10. 10Gb/s SFP+ CWDM 20km Transceiver. SFP10-CWDM-DML-xxxx-20KM-15DB-D10 Overview

PROLABS J9150A-C 10GBd SFP+ Short Wavelength (850nm) Transceiver

Features: Compliance: Applications. Warranty: NTTP03CF-GT OC-48/STM-16 IR1/S nm XCT Enhanced SFP Module Nortel Compatible

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

PROLABS GP-10GSFP-1S-C 10GBd SFP+ Short Wavelength (850nm) Transceiver

10GBd SFP+ Short Wavelength (850nm) Transceiver

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

4 Gigabit CWDM SFP CWDM SFP Transceiver RoHS Compliant Specification: F416S174XX-D

MODULETEK SFP10-CWDM-DML-xxxx-20KM-15DB-D10 10Gb/s SFP+ CWDM 20km Transceiver. SFP10-CWDM-DML-xxxx-20KM-15DB-D10 Overview.

Features: Compliance: Applications. Warranty: E1MG-CWDM GT CWDM SFP Optic, 80KM, 1550nm, LC Connector Brocade Compatible

PART NUMBER TX RX VOLTAGE TEMPERATURE. LSB2-A3M-PC-N nm 1310 nm 3.3 V 0 C to 70 C LSB2-A3M-PI-N nm 1310 nm 3.

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

Parameter Symbol Min Typ Max Unit Remarks Data Rate DR GBd IEEE 802.3ae Bit Error Rate BER Input Voltage V CC

CWDM SFP 1.25G 40KM LC Duplex

Features. Description. PART NUMBER TX RX VOLTAGE TEMPERATURE KSB2-A3S-PC-N nm 1310 nm 3.3 V 0 C to 70 C

RoHS Compliant 1310 nm Multi-mode Transceiver 2 5, LC Duplex Connector, 3.3 V 155 Mbps ATM/SONET OC-3/SDH STM-1/Fast Ethernet

Features: Compliance: Applications. Warranty: WS-G5484-GT 1000Base-SX GBIC MMF Cisco Compatible

Features: Compliance: Applications. Warranty: MGBS-GLX10-GT 1 Port Mini GBIC LX SMF Transceiver Amer Networks Compatible

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

Parameter Symbol Min Typ Max Unit Remarks Data Rate DR 1.25 GBd IEEE Bit Error Rate BER Input Voltage V CC

SPM-3102WG / SPM-3102BWG / SPM-3102AWG (RoHS Compliant) 3.3V / 1310 nm / 125 Mbps Digital Diagnostic LC SFP MULTI-MODE TRANSCEIVER

SRX-SFPP-10G-SR-ET-GT

SPB-7920WG / SPB-7920BWG / SPB-7920AWG (SC BIDI SFP)

VOLTAGE TEMPERATURE LD TYPE

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

10.3 Gb/s / 70 km / 1310 nm Digital Diagnostic SFP+ LC SINGLE-MODE TRANSCEIVER

Wavelength (nm) Absolute Maximum Ratings Parameter Symbol Min Max Units Notes Storage Temperature Tstg

Single Mode 1X9 Dual ST Transceiver 155MBs 5V. Applications Fiberoptic communications systems Networking Digital and Analog Signal transmission

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

Features: Compliance: Applications: Warranty: QFX-SFP-10GE-LR-GT SFP+ 10GBASE-LR 10GB 1310nm 10km Juniper QFX Compatible

SPB-3680LWG / SPB-3680BLWG / SPB-3680ALWG 1310 nm TX / 1550 nm RX, 3.3V / 155 Mbps Digital Diagnostic Single-Fiber SFP Transceiver

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

Prolabs CWDM-SFP8G-ER-xxxx

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

Features: Compliance: Applications. Warranty: S-35LC20D-GT SFP 1.25G 20km T1310nm/R1550nm MikroTik Compatible

Prolabs SFP-10G-LRM. Datasheet: Transceivers. 10GBd SFP+ LRM Transceiver. Ordering Information. Introduction. Ordering Information SFP-10G-LRM

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

RoHS Compliant TX-1310/RX-1550 nm Single-mode Bi-directional 2

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

3.3V / 1550 nm / 622 Mbps Digital Diagnostic LC SFP SINGLE-MODE TRANSCEIVER

SPB-9640G / SPB-9640BG / SPB-9640AG (SC BIDI SFP)

1.25Gbps SFP Optical Transceiver, 550m Reach

155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

3.3V / 1550 nm / 1.25 Gbps Digital Diagnostic LC SFP SINGLE-MODE TRANSCEIVER

OC-3/STM-1 SFP Transceivers with Digital Diagnostics

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

GPB-5303x-L2x(D) 155Mbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

Transcription:

Features RoHS compliant Compliant with SONET/SDH standard Compliant with Fast Ethernet standard Industry standard small form pluggable (SFP) package Duplex LC connector Differential LVPECL inputs and outputs Single power supply 3.3V TTL signal detect indicator Hot Pluggable Class 1 laser product complies with EN 60825-1 Ordering Information PART NUMBER WAVELENGTH INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE DC1470-SFP-LC.S120 1470 nm AC/AC TTL 3.3V 0 C to 70 C DC1490-SFP-LC.S120 1490 nm AC/AC TTL 3.3V 0 C to 70 C DC1510-SFP-LC.S120 1510 nm AC/AC TTL 3.3V 0 C to 70 C DC1530-SFP-LC.S120 1530 nm AC/AC TTL 3.3V 0 C to 70 C DC1550-SFP-LC.S120 1550 nm AC/AC TTL 3.3V 0 C to 70 C DC1570-SFP-LC.S120 1570 nm AC/AC TTL 3.3V 0 C to 70 C DC1590-SFP-LC.S120 1590 nm AC/AC TTL 3.3V 0 C to 70 C DC1610-SFP-LC.S120 1610 nm AC/AC TTL 3.3V 0 C to 70 C Page 1 of 10

Absolute Maximum Ratings PARAMETER SYMBOL MIN MAX UNITS NOTE Storage Temperature T S 40 85 C Supply Voltage Vcc 0.5 4.0 V Input Voltage V IN 0.5 Vcc V Output Current I o --- 50 ma Operating Current I OP --- 400 ma Page 2 of 10

Recommended Operating Conditions PARAMETER SYMBOL MIN MAX UNITS NOTE Case Operating Temperature T C 0 70 C Supply Voltage Vcc 3.1 3.5 V Supply Current I TX + I RX --- 300 ma Transmitter Electro-optical Characteristics Vcc = 3.1 V to 3.5 V, T C = 0 C to 70 C PARAMETER SYMBOL MIN TYP. MAX UNITS NOTE Data Rate B 50 155 200 Mb/s Output Optical Power 9/125 m fiber Pout 0 --- +5 dbm Average Extinction Ratio ER 10 --- --- db Central Wavelength (DC1470) C 1464.5 --- 1477.5 nm Central Wavelength (DC1490) 1484.5 --- 1497.5 nm Central Wavelength (DC1510) 1504.5 --- 1517.5 nm Central Wavelength (DC1530) 1524.5 --- 1537.5 nm Central Wavelength (DC1550) 1544.5 --- 1557.5 nm Central Wavelength (DC1570) 1564.5 --- 1577.5 nm Central Wavelength (DC1590) 1584.5 --- 1597.5 nm Central Wavelength (DC1610) 1604.5 --- 1617.5 nm Spectral Width (-20dB) --- --- 1 nm Side Mode Suppression Ratio SMSR 30 --- --- db Rise/Fall Time (10 90%) T r, f --- 1 2 ns Max. P out TX-DISABLE Asserted P OFF --- --- 45 dbm Output Eye Compliant with Telcordia GR-253-CORE Issue 3 and ITU-T recommendation G-957 Differential Input Voltage V DIFF 0.4 --- 2.0 V Page 3 of 10

Receiver Electro-optical Characteristics Vcc = 3.1 V to 3.5 V, T C = 0 C to 70 C PARAMETER SYMBOL MIN TYP. MAX UNITS NOTE Data Rate B 50 155 200 Mb/s Optical Input Power -maximum P IN 0 --- --- dbm Note 1 Optical Input Power minimum (Sensitivity) P IN --- --- 35 dbm Note 1 Operating Center Wavelength C 1260 --- 1600 nm Data Output Rise, Fall Time (10%~90%) T r, f --- 1 2 ns Loss of Signal-Asserted P A --- --- 35 dbm Loss of Signal-Deasserted P D 45 --- --- dbm Loss of Signal-Hysteresis P A P D 1.0 --- --- db Differential Output Voltage V DIFF 0.5 --- 1.2 V Receiver Loss of Signal Output Voltage-Low Receiver Loss of Signal Output Voltage-High RX_LOS L 0 --- 0.5 V RX_LOS H 2.4 --- V CC V Note 1: The input data is at 155.52 Mbps, 2 23 1 PRBS data pattern. The receiver is guaranteed to provide output data with Bit Error Rate (BER) better than or equal to 1 10 10. Page 4 of 10

Block Diagram of Transceiver ELECTRICAL SUBASSEMBLY DATA DATA/ TX_DISABLE LD Driver & Fault Sense LASER TX_FAULT (0) (1) (2) MOD_DEF OPTICAL SUB- ASSEMBLIES DUPLEX SC RECEPTACLE DATA DATA/ RX_LOS POST-Amp & LOS Detect RRE- AMPLIFIER IC Photo Diode TOP VIEW (Label side) Transmitter Section The transmitter section consists of a 1550 nm InGaAsP laser in an eye safe optical subassembly (OSA) which mates to the fiber cable. The laser OSA is driven by a LD driver IC which converts differential input LVPECL logic signals into an analog laser driving current. TX_DISABLE The TX_DISABLE signal is high (TTL logic 1 ) to turn off the laser output. The laser will turn on when TX_DISABLE is low (TTL logic 0 ). Receiver Section The receiver utilizes an InGaAs PIN photodiode mounted together with a trans-impedance preamplifier IC in an OSA. This OSA is connected to a circuit providing post-amplification quantization, and optical signal detection. Receive Loss (RX_LOS) The RX_LOS is high (logic 1 ) when there is no incoming light from the companion transceiver. This signal is normally used by the system for the diagnostic purpose. The signal is operated in TTL level. Page 5 of 10

Dimensions DIMENSIONS ARE IN MILLIMETERS ALL DIMENSIONS ARE 0.2mm UNLESS OTHERWISE SPECIFIED Unit: mm Page 6 of 10

SFP host board mechanical layout Y X L X A S 1 A S XY 1 PIN1 L X A S PIN1 A S B S LEGEND 1.PADS AND VIAS ARE CHASSIS GROUND 2.THROUGH HOLES, PLATING OPTIONAL 3.HATCHED AREA DENOTES COMPONENT AND TRACE KEEPOUT(EXCEPT CHASSIS GROUND) 4.AREA DENOTES COMPONENT KEEPOUT (TRACES ALLOWED) DIMENSIONS ARE IN MILLIMETERS A S B S A S B S Unit: mm Page 7 of 10

Assembly drawing 41.73 Ó0.5 3.5 Ó0.3 1.7 Ó0.9 PCB BEZEL CAGE ASSEMBLY BELOW PCB 9.8 MAX 15.0 MAX 11.0 REF. 15.25 Ó0.1 0.4 Ó0.1 10.4 Ó0.1 16.25 Ó0.1 MSA-SPECIFIED BEZEL PCB DIMENSIONS ARE IN MILLIMETERS Unit: mm Page 8 of 10

Pin Assignment Pin-Out PIN 11 PIN 20 PIN 10 PIN 1 Pin Signal Name Description 1 T GND Transmit Ground 2 TX_FAULT Transmit Fault 3 TX_DISABLE Transmit Disable 4 MOD_DEF (2) SDA Serial Data Signal 5 MOD_DEF (1) SCL Serial Clock Signal 6 MOD_DEF (0) TTL Low 7 RATE SELECT Open Circuit 8 RX_LOS Receiver Loss of Signal, TTL High, open collector 9 R GND Receiver Ground 10 R GND Receiver Ground 11 R GND Receiver Ground 12 RX Receive Data Bar, Differential PECL, ac coupled 13 RX Receive Data, Differential PECL, ac coupled 14 R GND Receiver Ground 15 V CCR Receiver Power Supply 16 V CCT Transmitter Power Supply 17 T GND Transmitter Ground 18 TX Transmit Data, Differential PCEL, ac coupled 19 TX Transmit Data Bar, Differential PCEL, ac coupled 20 T GND Transmitter Ground Page 9 of 10

Eye Safety Mark The LS4 series Single-mode transceiver is a class 1 laser product. It complies with EN 60825-1 and FDA 21 CFR 1040.10 and 1040.11. In order to meet laser safety requirements the transceiver shall be operated within the Absolute Maximum Ratings. Required Mark Class 1 Laser Product Complies with 21 CFR 1040.10 and 1040.11 Caution All adjustments have been done at the factory before the shipment of the devices. No maintenance and user serviceable part is required. Tampering with and modifying the performance of the device will result in voided product warranty. Note : All information contained in this document is subject to change without notice. Page 10 of 10