PERFORMANCE OF THE 110 GHz SYSTEM ON THE DIII D TOKAMAK

Similar documents
INFRARED MEASUREMENTS OF THE SYNTHETIC DIAMOND WINDOW OF A 110 GHz HIGH POWER GYROTRON

GA A24691 STATUS OF THE ELECTRON CYCLOTRON HEATING SYSTEM ON DIII D

INITIAL RESULTS FROM THE MULTI-MEGAWATT 110 GHz ECH SYSTEM FOR THE DIII D TOKAMAK

THE 110 GHz MICROWAVE HEATING SYSTEM ON THE DIII D TOKAMAK

AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES

PRACTICAL EXPERIENCES WITH THE 6 GYROTRON SYSTEM ON THE DIII D TOKAMAK

GA A26816 DESIGNS OF NEW COMPONENTS FOR ITER ECH&CD TRANSMISSION LINES

GA A22963 RECENT DEVELOPMENTS ON THE HIGH POWER ECH INSTALLATION AT THE DIII D TOKAMAK

GA A22776 THE DESIGN AND PERFORMANCE OF WAVEGUIDE TRANSMISSION LINE COMPONENTS FOR PLASMA ELECTRON CYCLOTRON HEATING (ECH) SYSTEMS

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

GA A22897 QUASI-OPTIC COMPONENTS IN OVERSIZED CORRUGATED WAVEGUIDE FOR MILLIMETER-WAVE TRANSMISSION SYSTEMS

GA A25836 PRE-IONIZATION EXPERIMENTS IN THE DIII-D TOKAMAK USING X-MODE SECOND HARMONIC ELECTRON CYCLOTRON HEATING

GA A26150 PROGRESS ON DESIGN AND TESTING OF CORRUGATED WAVEGUIDE COMPONENTS SUITABLE FOR ITER ECH AND CD TRANSMISSION LINES

TESTS AND PERFORMANCE ON THE SIX GYROTRON SYSTEM ON THE DIII-D TOKAMAK

A REGULATED POWER SUPPLY FOR THE FILAMENTS OF A HIGH POWER GYROTRON

INITIAL TESTS AND OPERATION OF A 110 GHz, 1 MW GYROTRON WITH EVACUATED WAVEGUIDE SYSTEM ON THE DIII D TOKAMAK

GA A25793 CW OPERATION OF CORRUGATED WAVEGUIDE TRANSMISSION LINES FOR ITER ECH AND CD SYSTEM

GA A22583 FAST WAVE ANTENNA ARRAY FEED CIRCUITS TOLERANT OF TIME-VARYING LOADING FOR DIII D

THE MEASURED PERFORMANCE OF A 170 GHz REMOTE STEERING LAUNCHER

Testing of ITER-Class ECH Transmission Line Components at the JAEA Radio-Frequency Test Stand

GA A22574 ADVANTAGES OF TRAVELING WAVE RESONANT ANTENNAS FOR FAST WAVE HEATING SYSTEMS

ECRF Heating on CS Reactors

GA A27238 MEASUREMENT OF DEUTERIUM ION TOROIDAL ROTATION AND COMPARISON TO NEOCLASSICAL THEORY IN THE DIII-D TOKAMAK

SUPPRESSION OF NEOCLASSICAL TEARING MODES IN THE PRESENCE OF SAWTEETH INSTABILITIES BY RADIALLY LOCALIZED OFF-AXIS

Study of Elliptical Polarization Requirement of KSTAR 84-GHz ECH System

GA A22577 AN ELM-RESILIENT RF ARC DETECTION SYSTEM FOR DIII D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

National Fusion Research Institute a. Princeton Plasma Physics Laboratory

GA A24030 ECE RADIOMETER UPGRADE ON THE DIII D TOKAMAK

PRESENT STATUS OF THE NEW MULTI-FREQUENCY ECRH SYSTEM FOR ASDEX UPGRADE

CT-7Ra Development of Gyrotron and JT-60U EC Heating System for Fusion Reactor

FAST WAVE ANTENNA ARRAY FEED CIRCUITS TOLERANT OF TIMElVARYING LOADING FOR DIII-D

Development in Russia of Megawatt Power Gyrotrons for Fusion

GA A22712 DIII D ICRF HIGH VOLTAGE POWER SUPPLY REGULATOR UPGRADE

GA A SOLID-STATE HIGH VOLTAGE MODULATOR WITH OUTPUT CONTROL UTILIZING SERIES-CONNECTED IGBTs by J.F. TOOKER and P. HUYNH

GYROTRON-BASED MILLIMETER-WAVE: BEAMS FOR MATERIAL PROCESSING. Thomas Hardek Wayne Cooke. William P e r r y D a n i e l Rees

2. Achievement of reliable long pulse operation of 1 MW 170 GHz gyrotron

GA A23281 EXTENDING DIII D NEUTRAL BEAM MODULATED OPERATIONS WITH A CAMAC BASED TOTAL ON TIME INTERLOCK

GA A25824 A NEW OVERCURRENT PROTECTION SYSTEM FOR THE DIII-D FIELD SHAPING COILS

Installation of 84-GHz, 500-kW KSTAR ECH system

Estimation of the Loss in the ECH Transmission Lines for ITER

Design study for JT-60SA ECRF system and the latest results of JT-60U ECRF system

Active Control for Stabilization of Neoclassical Tearing Modes

Development of the 170GHz gyrotron and equatorial launcher for ITER

Recent Development Results in Russia of Megawatt Power Gyrotrons for Plasma Fusion Installations

Recent progress of 170 GHz Gyrotron in KSTAR

Measurements of edge density profile modifications during IBW on TFTR

SUMMARY OF THE EXPERIMENTAL SESSION EC-10 WORKSHOP

US ITER Electron Cyclotron System White Paper

RECENT UPGRADES AND EXTENSIONS OF THE ASDEX UPGRADE ECRH SYSTEM

The report includes materials of three papers:

+o GENEML ATOMfCS. RF POWER DIAGNOSTICS AND CONTROL ON THE DIII-D, 4 MW MHz FAST WAVE CURRENT DRIVE SYSTEM (FWCD)

GA MICROWAVE WINDOW DEVELOPMENT

GA A FABRICATION OF A 35 GHz WAVEGUIDE TWT CIRCUIT USING RAPID PROTOTYPE TECHNIQUES by J.P. ANDERSON, R. OUEDRAOGO, and D.

Max-Planck-Institut für Plasmaphysik

Nanosecond, pulsed, frequency-modulated optical parametric oscillator

UCRL-ID Broad-Band Characterization of the Complex Permittivity and Permeability of Materials. Carlos A. Avalle

AN ELM=RESlLlENT RF ARC DETECTION SYSTEM FOR DIII-D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

Introduction to Radar Systems. The Radar Equation. MIT Lincoln Laboratory _P_1Y.ppt ODonnell

ECRH Beam Optics Optimization for ITER Upper Port Launcher

Operational progress of 170GHz 1MW ECH system in KSTAR

GA A23983 AN ADVANCED COLLABORATIVE ENVIRONMENT TO ENHANCE MAGNETIC FUSION RESEARCH

Final. NO.Report CRADA. Date: September 11, 1997

Hardware-in-the-Loop Testing of Wireless Systems in Realistic Environments

ENLARGEMENT OF GLASS AND PLASTIC SHELLS TO 2 mm IN DIAMETER BY REDROPPING THROUGH A SHORT HEATED TOWER

Sandia National Laboratories MS 1153, PO 5800, Albuquerque, NM Phone: , Fax: ,

STP-PT-032 BUCKLING OF CYLINDRICAL, THIN WALL, TRAILER TRUCK TANKS AND ASME SECTION XII

Experimental results and Upgrade plan of ECH/CD system in KSTAR

Development of C-Mod FIR Polarimeter*

National Accelerator LaboratoryFERMILAB-TM-1966

GA A24463 CONTROL SYSTEM FOR THE LITHIUM BEAM EDGE PLASMA CURRENT DENSITY DIAGNOSTIC ON THE DIII D TOKAMAK

Construction of 0.5-MW prototype PAM for KSTAR LHCD system

J.Shafii, J.N. Talmadge, R.J. Vernon, HSX team HSX Plasma Laboratory, University of Wisconsin-Madison T. S. Bigelow, ORNL K.M.

Experimental Results of Series Gyrotrons for the Stellarator W7-X

MAPPING INDUCED POLARIZATION WITH NATURAL ELECTROMAGNETIC FIELDS FOR EXPLORATION AND RESOURCES CHARACTERIZATION BY THE MINING INDUSTRY

High Explosive Radio Telemetry System. Federal Manufacturing & Technologies. R. Johnson, FM&T; B. Mclaughlin, FM&T;

Armlication For United States Patent For HOT CELL SHIELD PLUG EXTRACTION APPARATUS. Philip A. Knapp Moore, ID. and. Larry K. Manhart Pingree, ID

Tendencies in the Development of High-Power Gyrotrons

MAPPING INDUCED POLARIZATION WITH NATURAL ELECTROMAGNETIC FIELDS FOR EXPLORATION AND RESOURCES CHARACTERIZATION BY THE MINING INDUSTRY

Development Status of KSTAR LHCD System

RF HIGH VOLTAGE PERFORMANCE OF RF TRANSMISSION LINE COMPONENTS ON THE DIII-D FAST WAVE CURRENT DRIVE (FWCD) SYSTEM

System Upgrades to the DIII-D Facility

Radio Frequency Current Drive for Small Aspect Ratio Tori

STP-NU ROADMAP TO DEVELOP ASME CODE RULES FOR THE CONSTRUCTION OF HIGH TEMPERATURE GAS COOLED REACTORS (HTGRS)

A High-Power Gyrotron and high-power mm wave technology for Fusion Reactor

' Institut fuer Kernphysik, Strahlenzentrum, JLU Giessen, Germany 3

Status Alcator C-Mod Engineering Systems. DoE Quarterly Review October 27, 2005

Diagnostic development to measure parallel wavenumber of lower hybrid waves on Alcator C-Mod

Development of the long-pulse ECRF system for JT-60SA

Progress of Gyrotron Development for ITER

Accelerator and Fusion Research Division Lawrence Berkeley Laboratory University of California Berkeley, CA 94720

MONITORING POWER PLANT EFFICIENCY USING THE MICROWAVE-EXCITED PHOTOACOUSTIC EFFECT TO MEASURE UNBURNED CARBON. Quarterly Technical Progress Report

Abstract. G.D. Garstka 47 th APS-DPP Denver October 27, Pegasus Toroidal Experiment University of Wisconsin-Madison

Introduction to Radar Systems. Radar Antennas. MIT Lincoln Laboratory. Radar Antennas - 1 PRH 6/18/02

Summary: Gyrotron Development

High Frequency Gyrotrons and Their Applications

Five-beam Fabry-Perot velocimeter

ECRH on the Levitated Dipole Experiment

National Accelerator Laboratory

Transcription:

GA A23714 PERFORMANCE OF THE 110 GHz SYSTEM ON THE DIII D TOKAMAK by J. LOHR, R.W. CALLIS, W.P. CARY, I.A. GORELOV, R.A. LEGG, R.I. PINSKER, and D. PONCE JULY 2001

This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe upon privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

GA A23714 PERFORMANCE OF THE 110 GHz SYSTEM ON THE DIII D TOKAMAK by J. LOHR, R.W. CALLIS, W.P. CARY, I.A. GORELOV, R.A. LEGG, R.I. PINSKER, and D. PONCE This is a preprint of a paper presented at the 14th Radio Frequency Topical Conference, May 7 9, 2001, Oxnard, California, and to be printed in the Proceedings. Work supported by U.S. Department of Energy Contract No. DE-AC03-99ER54463 GENERAL ATOMICS PROJECT 30033 JULY 2001

Performance of the 110 GHz System on the DIII D Tokamak J. Lohr, R.W. Callis, W.P. Cary, I.A. Gorelov, R. Legg, R.I. Pinsker, and D. Ponce General Atomics, P.O. Box 85608, San Diego, California 82186-5608, U.S.A. Abstract: The 110 GHz system on the DIII-D tokamak comprises three Gycom Centaur class gyrotrons producing 750 kw for 2.0 sec pulses and one CPI VGT8110 series gyrotron producing 800 kw for 2.0 ec pulses. Total injected power is in excess of 2 MW. An additional two CPI gyrotrons are being prepared for operation following failure of their diamond output windows and these failures have resulted in operational limits on power and pulse length for the operating CPI gyrotron. The system has poloidally steerable launchers for four gyrotrons, two with oblique launch for current drive and two with perpendicular launch for heating only. A fully articulating launcher with poloidal scan and ±19 deg toroidal scan is also operational. Radiatively cooled mirrors capable of 1 MW for 10 s pulses at 1% duty cycle are being tested on the oblique launcher. New dummy loads based on conversion of the HE 1,1 fundamental mode to surface modes and having fast time response and 80% absorption of the incident rf are now in service. A new single mirror coupling scheme for the diamond window gyrotrons has cut losses in the wave coupling process in half to about 6% of the generated power for focused Gaussian beams. The evacuated windowless waveguide lines are up to 100 m in length and are greater than 90% efficient. The performance of the dummy loads, output power modulation, polarization control and the transmission line will be presented. The history and analysis of the failures of the diamond windows will also be discussed. SYSTEM DESCRIPTION The DIII-D ECH system now consists of four gyrotrons, each of which generates in excess of 700 kw at 110 GHz, plus beam correction and focusing optics, transmission lines, dummy loads, polarization controls and launchers. Power injected into the DIII D tokamak is in excess of 2.0 MW and pulse lengths, which are limited in each case by the capabilities of the gyrotron output windows, are up to 2.0 s. The system in its present configuration is shown in Fig. 1. Three of the gyrotrons, using BN output windows, were manufactured by Gycom [1] and one, with an artificially produced diamond disk output window, was manufactured by CPI [2]. The evacuated transmission lines [3] are up to 100 m in length and are up to 85% efficient in the best and about 70% in the worst case. In order to pass safely through the BN output windows, which absorb about 4% of the incident rf power, the rf beam in the Gycom gyrotrons was intentionally broadened. In order then to couple to the HE 1,1 fundamental circular waveguide mode, the rf beam from these gyrotrons had to be phase corrected and focused at the waveguide input. This is done with a system of two GENERAL ATOMICS REPORT GA A23714 1

CPI Tin Man Gycom Boris 7 Gycom Natasha CPI Future CPI Future 8 4 6 Radiation Shield Penetration Transmission Lines ~38 To ~91 Meters Efficiency ~ 92% 5 Remote Controlled Waveguide Isolation Valves For Each Line GYCOM Katya Vacuum Pump Manual Waveguide Isolation Valves Polarizers Dummy Load 1 FWD/REV Power Monitor (Future Waveguides) DIII D FIGURE 1. Isometric view of the gyrotron installation on the DIII D tokamak. The lines are grouped in pairs at the tokamak. Each line includes dummy load, polarizer pair, power monitor, isolation valve, and pumping system. mirrors, the surfaces of which were calculated from phase retrieval calculations using beam profile measurements on the free space propagating beam. The low loss and high thermal conductivity of the diamond window permits the CPI gyrotron to produce a Gaussian beam directly and this beam can be focused to a waist at the waveguide input using a single ellipsoidal mirror with about 94% efficiency compared with about 84% for the phase correcting two mirror system. The two coupling schemes are compared in Fig 2. The transmission lines are windowless and the waveguide pressure near the tokamak is less than 1 10 6 Torr. Polarization control is provided by pairs of sinusoidally grooved mirrors in miter bends. Each system is equipped with a dummy load capable of handling 1 MW for up to 1.0 s. The loads are inconel cylinders with stainless steel water jackets. It was necessary to improve the long pulse power handling capability of these loads, so a second load is being installed on each of the waveguide lines in front of the inconel loads. These new loads, which operate on the principle of mode conversion in smooth wall waveguide [4], are Glidcop with a stainless steel water jacket carrying about 240 l/min cooling water flow and include a waveguide bellows to compensate for the thermal expansion of the copper. The mode conversion loads absorb about 75% of the incident power and have the additional advantages that the thermal time response for calorimetry is greatly reduced. The combination of the two loads in series is as black as the plasma from the standpoint of reflected power and should operate cw at 1 MW absorbed power. GENERAL ATOMICS REPORT GA A23714 2

Vacuum Chamber Ellipsoidal Focus Mirror Gaussian Beam Infrared Image Diamond window 65 mm dia. Water Cooled Stray RF Absorber 31.75 mm w/g FIGURE 2. Waveguide coupling schemes with phase correction using a two mirror system for non- Gaussian beams and with no phase correction using a single mirror for Gaussian beams have both been used. The losses with the single mirror system are less than half those for the two mirror system. The figure shows the beam trajectory for the single mirror configuration superimposed on the two mirror arrangement. OPERATIONAL EXPERIENCE The gyrotron system itself has been very reliable and all the gyrotrons operate with rf generation efficiencies between 30% and 35%. Both modulated and unmodulated injection had been used at pulse lengths up to 2.0 s. Although modulation frequencies up to 20 khz have been demonstrated, square modulation envelopes at 100% modulation depth have only been demonstrated up to about 1 khz. In practice it is rare to modulate faster than about 300 Hz due to the poor signal/noise ratio for the tokamak diagnostics for rf pulses with low total energy. The control system supplies an analog signal to the high voltage modulator/regulator to modulate the output rf. About 15% 20% decrease in the high voltage supplied to the gyrotrons is sufficient to turn off the rf output. The electron beam is not cut off during modulation, so changes in the internal electrodynamics are kept to a minimum during the separate modulated pulses and the gyrotron operation is quite stable. Artificially produced diamond windows are being introduced on gyrotrons. These windows have thermal conductivity about four times greater than copper and, for the 2λ/2 thickness used in the new group of CPI gyrotrons, absorb about 0.2% of the transmitted power. The earliest CVD diamond windows placed in service used an aluminum diffusion bond and were edge cooled by water in contact with the diamond material. Despite the use of anti-corrosive additives in the water, corrosion of the window seals was a problem, which led to the failure of the window on the first test and development gyrotron installed at DIII D. A new braze technique using Au/Cu material has been developed at CPI and is being used in place of the aluminum bond technique. In addition to leaks in the seals, another window failed due to excessive microwave absorption which was believed to have arisen from a thin lossy layer on the surfaces of the diamond, which apparently formed during the braze process. These layers can easily be removed by proper mechanical etching. GENERAL ATOMICS REPORT GA A23714 3

CONCLUSION The high power gyrotron system on DIII D now is reliably injecting over 2.0 MW for up to 2.0 second pulses. Both current drive and heating/transport experiments have been performed. Two additional gyrotrons will be available during the 2002 experimental campaign. ACKNOWLEDGMENT This is a report of work supported by the U.S. Department of Energy under Contract No. DE-AC03-99ER54463. REFERENCES [1] Gycom, 46 Ul. Ulyanova, Nizhny Novgorod, 603600 Russia. [2] Communications and Power Industries, 811 Hansen Way, Palo Alto, CA 94304, USA. [3] Doane, J.L., Int. J. Infrared and Millimeter Waves 13, 123 (1985). [4] Doane, J.L., Int. J. Infrared and Millimeter Waves 14, 363 (1993). GENERAL ATOMICS REPORT GA A23714 4