CT-7Ra Development of Gyrotron and JT-60U EC Heating System for Fusion Reactor

Similar documents
Development of the 170GHz gyrotron and equatorial launcher for ITER

2. Achievement of reliable long pulse operation of 1 MW 170 GHz gyrotron

A High-Power Gyrotron and high-power mm wave technology for Fusion Reactor

The report includes materials of three papers:

Progress of Gyrotron Development for ITER

Development of the long-pulse ECRF system for JT-60SA

Operational progress of 170GHz 1MW ECH system in KSTAR

Experimental results and Upgrade plan of ECH/CD system in KSTAR

GA A24691 STATUS OF THE ELECTRON CYCLOTRON HEATING SYSTEM ON DIII D

Study of Elliptical Polarization Requirement of KSTAR 84-GHz ECH System

Recent progress of 170 GHz Gyrotron in KSTAR

Development in Russia of Megawatt Power Gyrotrons for Fusion

Experimental Results of Series Gyrotrons for the Stellarator W7-X

2.2 MW Operation of the European Coaxial-Cavity Pre-Prototype Gyrotron for ITER

INFRARED MEASUREMENTS OF THE SYNTHETIC DIAMOND WINDOW OF A 110 GHz HIGH POWER GYROTRON

Development of High Power Gyrotron and Power Modulation Technique using the JT-60U ECRF System )

Tendencies in the Development of High-Power Gyrotrons

Development of a Multi-Purpose, Multi-Frequency Gyrotron for DEMO at KIT

PERFORMANCE OF THE 110 GHz SYSTEM ON THE DIII D TOKAMAK

Design study for JT-60SA ECRF system and the latest results of JT-60U ECRF system

INITIAL RESULTS FROM THE MULTI-MEGAWATT 110 GHz ECH SYSTEM FOR THE DIII D TOKAMAK

National Fusion Research Institute a. Princeton Plasma Physics Laboratory

GA A26150 PROGRESS ON DESIGN AND TESTING OF CORRUGATED WAVEGUIDE COMPONENTS SUITABLE FOR ITER ECH AND CD TRANSMISSION LINES

GA A26816 DESIGNS OF NEW COMPONENTS FOR ITER ECH&CD TRANSMISSION LINES

Recent Development Results in Russia of Megawatt Power Gyrotrons for Plasma Fusion Installations

Testing of ITER-Class ECH Transmission Line Components at the JAEA Radio-Frequency Test Stand

ECRF Heating on CS Reactors

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

Installation of 84-GHz, 500-kW KSTAR ECH system

INITIAL TESTS AND OPERATION OF A 110 GHz, 1 MW GYROTRON WITH EVACUATED WAVEGUIDE SYSTEM ON THE DIII D TOKAMAK

RECENT UPGRADES AND EXTENSIONS OF THE ASDEX UPGRADE ECRH SYSTEM

Design and experimental study of a high power 140 GHz, TE22.6 mode gyrotron for EAST

Estimation of the Loss in the ECH Transmission Lines for ITER

RF Heating and Current Drive in the JT-60U Tokamak

US ITER Electron Cyclotron System White Paper

GA A22963 RECENT DEVELOPMENTS ON THE HIGH POWER ECH INSTALLATION AT THE DIII D TOKAMAK

J.Shafii, J.N. Talmadge, R.J. Vernon, HSX team HSX Plasma Laboratory, University of Wisconsin-Madison T. S. Bigelow, ORNL K.M.

Max-Planck-Institut für Plasmaphysik

AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES

Summary: Gyrotron Development

THE 110 GHz MICROWAVE HEATING SYSTEM ON THE DIII D TOKAMAK

PRESENT STATUS OF THE NEW MULTI-FREQUENCY ECRH SYSTEM FOR ASDEX UPGRADE

High Frequency Gyrotrons and Their Applications

GA A25793 CW OPERATION OF CORRUGATED WAVEGUIDE TRANSMISSION LINES FOR ITER ECH AND CD SYSTEM

GA A22776 THE DESIGN AND PERFORMANCE OF WAVEGUIDE TRANSMISSION LINE COMPONENTS FOR PLASMA ELECTRON CYCLOTRON HEATING (ECH) SYSTEMS

MITER BEND MIRROR DESIGN FOR CORRUGATED WAVEGUIDES

GA MICROWAVE WINDOW DEVELOPMENT

PARAMETRIC STUDY OF OHMIC WALL HEATING IN COAXIAL CAVITY

H. Y. Lee, J. W. Lee, J. G. Jo, J. Y. Park, S. C. Kim, J. I. Wang, J. Y. Jang, S. H. Kim, Y. S. Na, Y. S. Hwang

Research and Development of 2-frequency (110/138 GHz) FADIS for JT-60SA ECHCD system

PRACTICAL EXPERIENCES WITH THE 6 GYROTRON SYSTEM ON THE DIII D TOKAMAK

Active Control for Stabilization of Neoclassical Tearing Modes

Heating Issues. G.Granucci on behalf of the project team

HIGH-POWER CORRUGATED WAVEGUIDE COMPONENTS FOR mm-wave FUSION HEATING SYSTEMS

Handling Technology of Mega-Watt

GA A25836 PRE-IONIZATION EXPERIMENTS IN THE DIII-D TOKAMAK USING X-MODE SECOND HARMONIC ELECTRON CYCLOTRON HEATING

3.10 Lower Hybrid Current Drive (LHCD) System

Design and R&D for an ECRH Power Supply and Power Modulation System on JET

Development of Collective Thomson Scattering System Using the Gyrotrons of Sub-Tera Hz Region

SUPPRESSION OF NEOCLASSICAL TEARING MODES IN THE PRESENCE OF SAWTEETH INSTABILITIES BY RADIALLY LOCALIZED OFF-AXIS

An overview of the ITER electron cyclotron H&CD system

FaDiS, a Fast Switch and Combiner for High-power Millimetre Wave Beams

System Upgrades to the DIII-D Facility

1 ITER India, Institute of Plasma Research, 2 Continental Electronics

Abstract. G.D. Garstka 47 th APS-DPP Denver October 27, Pegasus Toroidal Experiment University of Wisconsin-Madison

TESTS AND PERFORMANCE ON THE SIX GYROTRON SYSTEM ON THE DIII-D TOKAMAK

Development Status of KSTAR LHCD System

Development of a 20-MeV Dielectric-Loaded Accelerator Test Facility

Non-inductive Production of Extremely Overdense Spherical Tokamak Plasma by Electron Bernstein Wave Excited via O-X-B Method in LATE

Power-stabilization of high frequency gyrotrons using a double PID feedback control for applications to many high power THz spectroscopy

NEW OPPORTUNITIES IN VACUUM ELECTRONICS USING PHOTONIC BAND GAP STRUCTURES

Neoclassical Tearing Mode Control with ECCD and Magnetic Island Evolution in JT-60U

Presented by Rob La Haye. on behalf of Francesco Volpe. at the 4 th IAEA-TM on ECRH for ITER

Gyroklystron Research at CCR

Increased Stable Beta in DIII D by Suppression of a Neoclassical Tearing Mode Using Electron Cyclotron Current Drive and Active Feedback

Towards a 0.24-THz, 1-to-2-MW-class gyrotron for DEMO

Development of ITER Equatorial EC Launcher

ECRH Beam Optics Optimization for ITER Upper Port Launcher

Improved core transport triggered by off-axis ECRH switch-off on the HL-2A tokamak

3D full wave code modelling of ECRF plasma heating in tokamaks and ITER at fundamental and second harmonics

GA A25780 STABILIZATION OF NEOCLASSICAL TEARING MODES IN TOKAMAKS BY RADIO FREQUENCY CURRENT DRIVE

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

High-power microwave diplexers for advanced ECRH systems

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

A NEW MULTI-POINT, MULTI-PULSE THOMSON SCATTERING SYSTEM FOR THE MST RFP

Helicon Wave Current Drive in KSTAR Plasmas

Control of Induction Thermal Plasmas by Coil Current Modulation in Arbitrary-waveform

The 140-GHz 1-MW CW Gyrotron for the Stellarator W7-X

Stability Analysis of C-band 500-kW Klystron with Multi-cell. Output cavity

Module IV, Lecture 2 DNP experiments and hardware

FIR Center Report. Gyrotron FU CW VII for 300 MHz and 600 MHz DNP-NMR spectroscopy

DESIGN OF A 60 GHz, 100 kw CW GYROTRON FOR PLASMA DIAGNOSTICS: GDS-V.01 SIMULATIONS

QPR No SPONTANEOUS RADIOFREQUENCY EMISSION FROM HOT-ELECTRON PLASMAS XIII. Academic and Research Staff. Prof. A. Bers.

6 Electromagnetic Field Distribution Measurements using an Optically Scanning Probe System

Observation of Electron Bernstein Wave Heating in the RFP

Launcher Study for KSTAR 5 GHz LHCD System*

THE MEASURED PERFORMANCE OF A 170 GHz REMOTE STEERING LAUNCHER

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

EXW/10-2Ra. Avoidance of Disruptions at High β N in ASDEX Upgrade with Off-Axis ECRH

Transcription:

Development of Gyrotron and JT-6U EC Heating System for Fusion Reactor K. SAKAMOTO 1), A. KASUGAI 1), YO. IKEDA 1), K. HAYASHI 1), K. TAKAHASHI 1), K. KAJIWARA 1), S. MORIYAMA 1), M. SEKI 1), T. KARIYA 2), Y. MITSUNAKA 2), M. TSUNEOKA 1), T. FUJII 1) AND T. IMAI 1) 1) Naka Fusion Research Establishment, JAERI, Naka-machi, Ibaraki-ken 311-1 Japan 2) Display Devices & Components Company, Toshiba Co., Ootawara-shi, Tochigi, 324-855 Japan e-mail: sakamotk@naka.jaeri.go.jp Abstract. The progress of ECH technology, for ITER and JT-6U tokamak, are presented. In the development of gyrotron,.9mw/9.2sec,.5mw/3sec,.3mw/6sec, etc. have been demonstrated at 17GHz. At 11GHz, 1.3MW/1.2sec, 1.2MW/4.1sec, 1MW/5sec were obtained. It is found that the reduction of the stray radiation and the enhancement of cooling capability are keys for CW operation. Four 11GHz gyrotrons are under operation in the ECH system of JT-6U. The power up to approximately 3MW/2.7sec was injected into the plasma through the poloidally movable mirrors, and contributed to the electron heating up to 26keV(n e ~.5x1 13 cm -3 ), and the suppression of the neo-classical tearing mode. 1. Introduction The Electron Cyclotron (EC) wave is an effective method of on- and off-axis current drive and plasma profile control for fusion reactors. Injection of 2 MW EC power is planned in the ITER design to suppress the Neo-Classical Tearing Modes (NTMs). A 17GHz, 1 MW gyrotron is a key R&D technology of the ITER EC system and intensive efforts have been made in JAERI to develop the 17GHz gyrotron. During ITER EDA, successes of introducing the depressed collector[1], high order mode oscillation at 17GHz/1MW[2] and installation of a CVD diamond window on the gyrotron[3-5] opened a new stage of gyrotron development. Further advancement to suppress unnecessary modes like parasitic oscillations was achieved[6]. Together with these, integration efforts of the key EC technologies have also been devoted in the 11GHz EC system on JT-6U. The construction had been started in 1998 by use of the technology outcomes of ITER R&D and the system with four 1MW gyrotrons started its operation in 21[7]. In the following sections, the latest results of development of gyrotrons and ECH system on JT-6U are described. 2. Gyrotron Development 2.1 17GHz gyrotron A photograph of the 17GHz gyrotron and a cross sectional view of the gyrotron are shown in Fig.1 and Fig.2, respectively. A triode type electron gun (magnetron injection gun: MIG) and mirror magnetic field makes a rotating electrons with an energy of 7keV~ 85keV, which are injected into a cylindrical cavity and generate TE 31, 8 mode RF of more than 1MW. Q-factor of the cavity is 153. The oscillation power is converted to the Gaussian beam using a quasi-optical mode converter and outputted through the low loss diamond window. The design value Fig.1: Appearance of of the radiation power from the window is 94%. A gyrotron 17GHz gyrotron. experiment was carried out on a gyrotron test stand (RFTS). The Height is ~3m. capability of RFTS is 9kV/5A for long pulse operation, and

CPD Main DC Deceleration Acceleration Cavity Diamond Window RF DC Break Quasi-optical mode converter SCM Electron gun Fig.2: Cross sectional view of depressed collector gyrotron. 183mm 28.5mm 51mm Magnetron Injection Gun Cavity Cathode Anode Fig.4: SiC cylinder at beam tunnel for suppression of parasitic oscillation. Gaussian output ( at Window) After MOU 9kV/8A up to a few milliseconds. A power supply is consisted of main power supply (MPS) and beam acceleration power supply (APS). The difference between MPS and APS appears as a retarding potential on the spent electron beam at a ceramic insulator (DC break) for a depressed collector operation. A switching of the MPS is done by IGBT (Insulated Gate Bipolar Transistor). The output power is focused to the corrugated waveguide of 31.75mm in diameter using two phase-correction mirrors in the matching optics unit (MOU). As the rf power is radiated as a Gaussian beam through the diamond window, high efficiency coupling is expected. The MOU and transmission line should be evacuated to avoid the breakdown. In the experiment, the Gaussian beam was formed at the window as shown in Fig.3. The transmitted power to the dummy load placed after 12m corrugated waveguide via three miter bends was 95% of the gyrotron power. In the previous 17GHz gyrotron, oscillation efficiency was ~24% at most because a parasitic oscillation occurred in the beam tunnel (a region between the electron gun and the cavity). The frequency of the parasitic oscillation was ~14GHz, which indicates the beam instability due to the cyclotron resonance. The power of the parasitic oscillation was sometimes in the order of a few tens kw, which causes an electron energy broadening and consequently decrease of the main oscillation efficiency. To suppress the parasitic oscillation, SiC cylinders were installed on the surface of the beam tunnel as shown in Fig.4. Since the SiC is a good mm wave absorber, the growth of the instability is anticipated to be suppressed. The adopted SiC cylinders have a finite resistivity, no electrification would occur. As a result, the parasitic oscillation power was suppressed and the output of 1.3 MW with High efficiency coupling Transmission line 31.75mm Waveguide MOU Gyrotron RF beam Focusing mirror 95% (Dummy load/gyrotron) Fig.3: Gyrotron and matching optics unit (MOU) for coupling with waveguide. Measured wave patterns at the gyrotron window and at the waveguide mouth are shown. Power (MW) 1.5 1.5 Power Efficiency 1 2 3 4 5 6 7 Beam Current (A) (A) 4 3 2 1 Efficiency (%) Efficiency (%) Fig.5: Beam current dependence of Power and efficiency at 17GHz. Beam is ~74.5kV.

31% of oscillation efficiency was achieved. In Fig.5, a beam current dependence of the output power and of efficiency (without depressed collector) is shown. The beam is 74.5kV. The quasi-cw operations have been demonstrated as listed in table 1. Figure 6 is typical waveforms of 47sec operation at.45mw output. It is noteworthy that the temperatures of major components like cavity, window and collector stabilized within 5s and operation was quite stable. It took almost no conditioning time to extend the pulse duration from 1 s to 3 s at 5 kw, which gives a promising view to the ITER CW gyrotron. A key point of this fast conditioning is an active extraction of stray radiation power inside the gyrotron through the DC break ceramic and a sub-window. The aperture of the sub-window is 12mm. A material of the DC break Pressure (Torr) CPD Voltage(29kV) Anode Voltage(-3.3kV) Cathode Voltage(-46kV) Beam Current (25.8A -> 22.3A) RF Power (45kW) 47 sec Fig.6: x1-8 Waveforms of 45kW operation 2 at 17GHz No need of 15 Conditioning 1 5 5 1 152 25 Time (Sec.) ceramic and sub-window is silicon nitride (SN287, Kyocera Co., tanδ~2x1-4 ). The stray radiation was absorbed by water in the Teflon tube and the FX-33 (3M), which flew around the DC break. The total power of the stray radiation that was extract through the DC break and the sub-window is ~8% of the output power. A power deposition of the stray radiation to the SiC cylinder at the beam tunnel was.35% of the output power (mainly to upper one). The pulse extension was prevented by pressure increase in the gyrotron. In Fig.7, the typical behavior of the pressure is shown. Basically, pressure is kept in very low level, but sudden increase of the pressure occurs. The cause was confirmed that the temperature increase of the component of poor cooling (bellows behind the steering mirror that is made of SUS), which absorbed the stray radiation, and probably exceeded a baking temperature 45 C. Further extension of the pulse duration will be achieved by enhancing the cooling capability of the minor sub-components. 2.2 11GHz gyrotron The 11GHz gyrotron has a same appearance with 17GHz. The oscillation mode is TE 22, 6. Q-value of the cavity is 13. The heat load on the cavity wall is Fig.7: Behavior of pressure in the gyrotron during.2mw operation. 1.2kW/cm 2 at 1MW operation, that is well below the criteria of the heat load of 2kW/cm 2. The MIG is triode, oscillation power of TE 22,6 mode is converted to Gaussain beam using the quasi-optical mode converter. The thickness of the diamond disk is 1.715mm. At the beam tunnel, SiC cylinder that has a same size with 17GHz gyrotron is installed. The gyrotron experiment was carried out RFTS using the same magnet. Fig.8 is a beam current dependence of the output power and efficiency at 1msec operation. The beam is 84.5kV. At I b =57A, the output power was 1.56MW. The maximum efficiency was 33% (1.3MW) at I b =47A. As with the 17GHz experiment, 94% of the output power was transmitted to the dummy load after three miter bends using a same transmission line. Long pulse operation is underway. Up to now, 1.3MW/1.2sec (efficiency of 48% with depressed collector), 1.2MW/4.1sec 1.MW/5sec were obtained (Table 1). Since the heat load on the cavity wall has enough margins at 1MW, long pulse operation with higher power such as 1.5MW could be possible.

3. JT-6U EC System CT-7Ra The EC system in JT-6U has similar configuration to the ITER except a launcher. The RF power from the gyrotron is transmitted through evacuated corrugated waveguide and the CVD diamond torus window to the launcher. The RF beam is steered by movable mirrors and injected into plasma. The key points of EC system technology are 1) gyrotrons; 2) high efficiency and high power transmission; 3) fast and accurate scanning of RF beam direction to the plasma. On the first point, the performance of the gyrotron was proved as described in the previous section. However, when the gyrotron is operated in the EC system, where the several gyrotrons and other apparatus are simultaneously operated, some unexpected 1 2 3 4 5 6 7 Beam Current (A) effects arise. As the power supply is converted from that of lower hybrid system, the of the main power supply V main is not regulated. The stabilized of the accelerating DC Table 1: Long pulse operation Frequency Power Duration (GHz) (kw) (sec) 17 11 9 9.2 75 17. 5 3. 45 47. 3 6. 2 132. 13 1.2 12 4.1 1 5. Power (MW) 1.6 1.2.8.4 Power Efficiency Power Supply (APS), which determines the beam energy of the gyrotron V b, guarantees the gyrotron operation itself. The perturbation of the MPS appears on the retarding potential for the depressed collector V dp. Here, V dp =V b -V main. When ev dp deeply exceeded the minimum energy of the spent beam, electron trapping becomes a problem. The electron trapping cause an increase of a leak current to the anode of MIG, which seems to be a cause of the trip of the power supply. In particular, it was frequent when the four gyrotrons start at same timing by a mutual coupling of the perturbation. The influence of the perturbation could be reduced by setting a ramp-up of the electron beam slow and V dp lower. As a result, the simultaneous operation of four gyrotrons has been 8 6 4 2 Efficiency(%) Fig.8: Beam current dependence of power and efficiency at 11GHz. Beam is 84.5kV. Pulse duration is 1msec. Te (kev) angle ( ) Injected power (MW) 6 55 35 4 Te() Te(.3) 3 4 5 6 7 8 9 time(s) on-axis off-axis Z (m) Injected angle of EC beams 1-1 37 51 w ce Rw ec 2 3 4 R (m) Antenna A Antenna B Fig.9: Real time control of electron temperature using antennas.

succeeded. For an EC system of many gyrotrons, stabilized main power supply is desired to obtain a stable and high efficiency operation. Present issue for simultaneous operation is a trip of power supply caused by a noise from other apparatus. On the second point, the coupling of the gyrotron output power with the waveguide was optimized by the careful adjustment of two mirrors in MOU, which is important for excitation of HE 11 mode. And periodic sag of the waveguide has been minimized using the laser beam alignment technique. Present value of the transmission efficiency is ~8 %. The transmission line is composed of corrugated waveguide of 31.75mm in diameter, 7 miter bends and pair of polarizers are included. Total length is ~6m. The pressure inside the transmission line is kept in vacuum ~ 1x1-3 Pa, and a breakdown was not observed. The torus CVD diamond windows of 31.75mm and 6.5mm in aperture have shown a capability of stable 1 MW transmission. The performance of the launching system has been studied with two antennas for the last point. The dynamic beam steering capability was confirmed as shown in Fig. 9. Two antennas control the RF beam injection independently in a poloidal direction and the change of electron heating in the center is observed. The maximum central heating is obtained in case of the onaxis heating of antenna A. The maximum injection performance of approximately 3 MW for 2.7 s was achieved. As a result, the EC system contributed to realize high electron temperature plasma of 26keV [8], a suppression of neoclassical tearing mode [9] and current drive [1]. 4. Concluding Remarks The recent progresses of ECH technology development in JAERI are presented. The development of high power 17GHz and 11GHz gyrotrons has attained remarkable progress for ITER and JT-6U, respectively. At 17GHz, power outputs of.9mw/9.2sec,.75mw/17sec,.5mw/3sec,.45mw/47sec,.3mw/6sec,.2mw/133sec, etc have been demonstrated. And at 11GHz, 1.2MW/4.1sec, 1MW/5sec were obtained. These powers and pulse durations are limited by the temperature increase of the inner components, which was caused by the stray radiation from the built-in mode converter. The reduction of the stray radiation and the enhancement of cooling capability are essential for CW operation. Using four 11GHz gyrotrons, the EC system is under operation on JT-6U. High power operation of the gyrotrons with simultaneous operation and high efficiency transmission enabled a 3MW/2.7sec injection. By the power deposition control using movable mirrors, the EC system contributed to the electron temperature of 26keV(n e ~.5x1 13 cm -3 ), and the suppression of the neo-classical tearing mode. These results give a prospect for the ITER EC system. References [1] Sakamoto, K., et al., Phys.Rev.Lett., 73, (1994) 3532. [2] Sakamoto,K., et al., J.Phys.Soc.Jpn., 65, (1996) 1888. [3] Braz,O., et al., Int.J.Infrared and millimeter Waves, 18, (1997) 1495. [4] Kasugai,A., et al., Rev. Sci. Instrum, 69, (1998) 216. [5] Sakamoto,K., et al., Rev. Sci. Instrum., 7, (1999) 28. [6] Shoyama,H.,et al., Jpn. I. Appl. Phys., 4, (21) 96. [7] Ikeda,Y.,et al., Fusion Science and Technology, 42, (22) 435. [8] Ishida,S., and the JT-6 Team, Proc. of IEEE 19th Symp. on Fusion Engineering, Atlantic,NJ, USA,22. [9] Isayama,A., et al., Plasma Phys. and Contr. Fusion, 42, L37 (2). [1] Suzuki,T., et al., Plasma Phys. And Contr. Fusion, 44, (22) 1.