M5028 Precision Tuned Magnetron

Similar documents
E2V Technologies MG6028 Fast Tuned Magnetron

MG7095 Tunable S-Band Magnetron

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

MG5223F S-Band Magnetron

MG5193 Tunable S-Band Magnetron

MG6090 Tunable S-Band Magnetron

MG MW S-Band Magnetron

E2V Technologies MG5223F S-Band Magnetron

E2V Technologies M5187F X-Band Magnetron

E2V Technologies MG5222 X-Band Magnetron

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

M5187 X-Band Magnetron

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

CX1140 Hydrogen Thyratron

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

S-band 500kW Magnetron

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

ABSOLUTE MAXIMUM RATINGS These ratings cannot necessarily be used simultaneously and no individual ratings should be exceeded.

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

9007 Power Tube. VHF Linear Power Amplifier Tube 33 Kilowatt Peak Sync Output Thru VHF-TV Band

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE DOD-011

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943

Power Tube. Beam Power Tube

CCD42-10 Back Illuminated High Performance AIMO CCD Sensor

CCD30-11 NIMO Back Illuminated Deep Depleted High Performance CCD Sensor

CCD97-00 Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor

8121 Power Tube. Linear Beam Power Tube

STA3318 Series StellarMini TM 180 W, Ku-Band Antenna Mount TWTA

CCD47-10 NIMO Back Illuminated Compact Pack High Performance CCD Sensor

Fig.1 Heater dissipation test circuit

8984 Power Tube. VHF Linear Beam Power Tube

8988 Power Tube. Linear Beam Power Tube

4665 Power Tube UHF Pulsed Power Amplifier Tube

RADIAL BEAM POWER CPI RADIAL 4CW50,000J BEAM POWER TETRODE 4CX20,000C

HIGH-MU POWER TRIODE 3CW40,000A7

6884 Power Tube. Beam Power Tube

CCD30-11 Front Illuminated Advanced Inverted Mode High Performance CCD Sensor

MA2709A Thyratron Trigger System

MEDIUM-MU AIR-COOLED POWER TRIODE 3CX15,000H3

Current Probes. User Manual

CCD Back Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor

Siemens Aktiengesellschaft 211

R S / R 100ppb 0.1. Fig. 1: R S /R 0 as a function of gas concentration at 50% RH and 25 C.

Svetlana 4CX7500A Radial Beam Power Tetrode

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

YC-179 / YC-179A CPI HIGH-MU 4CW50,000J POWER TRIODE YC-179 / YC-179A

CCD30 11 Back Illuminated High Performance CCD Sensor

TECHNIlCAL DATA. Amperes Cathode Heating Time..300

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

Transmitter Triode RS 2041 V YD 1262

Siemens Aktiengesellschaft 137

8792 Power Tube. Linear Beam Power Amplifier Tube

CCD67 Back Illuminated AIMO High Performance Compact Pack CCD Sensor

8807 Power Tube. Beam Power Tube

General Data Electrical Heater for Oxide-Coated Unipotential Cathode: Voltage (AC or DC) 26.5 ± 10% Current at 26.5 volts

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

Rotating Anode X-Ray Tube Housing Assembly. General Data

CCD47-20 Back Illuminated NIMO High Performance NIMO Back Illuminated CCD Sensor

L A B O R A T O R I E S 9740 COZYCROFT AVENUE * CHATSWORTH * CALIFORNIA (800) * (818) * FAX: (818)

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 6410A

Marconi Applied Technologies CCD30-11 Inverted Mode Sensor High Performance CCD Sensor

4662 Power Tube. Linear Beam Power Tube

CCD55-30 Inverted Mode Sensor High Performance CCD Sensor

Transmitter Tetrode RS 1034

CCD42-40 NIMO Back Illuminated High Performance CCD Sensor

CCD97 00 Front Illuminated 2-Phase IMO Series Electron Multiplying CCD Sensor

Instruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER. OM POWER, s. r. o Bác 126 SLOVAKIA

CCD42-40 NIMO Back Illuminated High Performance CCD Sensor

90 Siemens Aktiengesellschaft

E2V Technologies CCD42-80 Back Illuminated High Performance CCD Sensor

E2V Technologies CCD42-10 Inverted Mode Sensor High Performance AIMO CCD Sensor

1 SAFETY INSTALLATION OPERATION COMPONENTS FAULT DIAGNOSTICS FUNCTIONS TECHNICAL SPECIFICATIONS...

4X150A/7034 Radial Beam Power Tetrode

CCD42-80 Back Illuminated High Performance CCD Sensor

8791 Power Tube. Linear Beam Power Amplifier Tube

Siemens Aktiengesellschaft 299

Transmitter Tetrode TH 347

CUSTOMER S ACCEPTANCE SPECIFICATIONS

Product Information PI

PL8877/ 3CX1500A7 High-Mu Power Triode

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

CCD77-00 Front Illuminated High Performance IMO Device

MAIN FEATURES OVERVIEW GENERAL DATA ORDERING INFORMATION

HIGH-MU AIR-COOLED POWER TRIODE 3CX1500D7

CBA 400M MHZ to 400 MHZ

4CM500,000G MULTIPHASE-COOLED POWER TETRODE

Marconi Applied Technologies

Transmitter Tetrode. Approx. weight 1,1 kg Packing dimensions: approx. 310 mm 310 mm 320 mm. Siemens Aktiengesellschaft 375

> Microwave Ovens and their Hazards

Marconi Applied Technologies CCD47-20 High Performance CCD Sensor

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Marconi Applied Technologies CCD39-01 Back Illuminated High Performance CCD Sensor

8072 Power Tube. VHF Linear Amplifier Tube. Coaxial-Electrode Structure Ceramic-Metal Seals Full Input to 500 MHz Conduction Cooled

1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03

+Vin. Input Return. +Vin. Input Return

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

Transcription:

M5028 Precision Tuned Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Precision tuned pulse magnetron for linear accelerators. The tuning drive will mechanically tune the tube to within 50 khz of any point in the frequency range and has been designed to be driven remotely by an electric motor. Frequency range (see note 1)... 2856 to 2859 MHz Peak output power (nominal)... 5.0 MW Magnet and launching section...separate electromagnet and launching section assembly MG6030 Isolator (see note 2)... use of an isolator is recommended Output... no. 10 waveguide (72.14 x 34.04 mm internal) Cooling... water and forced-air, or water and SF 6 GENERAL DATA Electrical Cathode... indirectly heated Heater voltage (see note 3)... 13 V Heater current... 14 A Heater starting current, peak value, not to be exceeded... 40 A max Cathode pre-heating time (minimum)... 6.0 minute Mechanical Overall dimensions... see outline Net weight... 8 kg approx Mounting position... any Tuning drive... splined shaft, to mate with S.S. White EX977 remote control flexible shaft Tuner turns between stops... 346 turns Accessories Electromagnet/launching section... MG6030 Sidearm radiation absorber... MA761 1 F coaxial capacitor (see note 3)... MA997A Cooling The magnetron anode and the electromagnet have integral water jackets. The magnetron requires a water flow of 18 to 27 litres/minute; the pressure drop across the water jacket is 103 kpa maximum. The electromagnet requires a water flow of 4.5 litre/minute at a pressure drop of 14 kpa. The magnetron output window may be cooled by either high pressure air or an arc suppressant gas such as SF 6. When the output window is cooled by high pressure air, a flow of not less than 0.085 m 3 /minute (NTP) into the air inlet at the base of the launching section is required. If SF 6 is used, then no gas flow is required to cool the window. See note 4. Low pressure air cooling may be required for the cathode terminal. Whilst e2v technologies has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. e2v technologies accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein. e2v technologies (uk) limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU United Kingdom Holding Company: e2v technologies plc Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492 Contact e2v by e-mail: enquiries@e2v.com or visit www.e2v.com for global sales and operations centres. e2v technologies (uk) limited 2013 A1A-M5028 Version 7, June 2013 Template: DF764388A-7 115046

MAXIMUM AND MINIMUM RATINGS (Absolute values) These ratings cannot necessarily be used simultaneously, and no individual rating should be exceeded. Min Max Magnetic field (see note 5)... 120 164 mt Heater voltage (see note 3)... 12.0 13.5 V Anode voltage (peak)... 34 55 kv Anode current (peak): at 5.0 MW, 3.0 s, 158 mt... - 265 A at 2.5 MW, 5.0 s, 153 mt... - 160 A at 1.0 MW, 5.0 s, 135 mt... - 100 A Input power (peak) (see note 9)... - 14 MW Input power (mean) (see note 10)... - 7.0 kw Duty cycle... - 0.003 TYPICAL OPERATION Operating Conditions Min Max Pulse duration: at 5.0 MW peak... - 3.0 s at 2.5 MW peak... - 5.0 s at 1.0 MW peak... - 5.5 s Rate of rise of voltage pulse (see note 11)... 100 150 kv/ s VSWR at the output coupler (see note 3)... - 1.3:1 Anode water outlet temperature... - 70 C Tuner torque... - 0.21 Nm Pressurising of waveguide (see note 7)... - 448 kpa Heater voltage... 6.0 6.0 6.0 V Magnetic field... 135 153 158 mt Anode current (peak)... 60 130 240 A Pulse duration... 5.0 4.0 2.3 s Duty cycle... 0.003 0.0012 0.00055 Rate of rise of voltage... 125 125 125 kv/ s Typical Performance Anode voltage... 36.5 46 51 kv Output power (peak)... 1.0 2.7 5.5 MW Output power (mean)... 3.0 3.2 3.0 kw TEST CONDITIONS AND LIMITS The magnetron is tested in electromagnet and launching section type MG6030 to comply with the following electrical specification at 2856, 2857.7 and 2859 MHz. Test Conditions Heater voltage (for test)... 8 V Output window cooling air flow (max)... 0.08 m3/minute Waveguide air pressure (max)... 310 kpa abs. Electromagnet current... 32 A Anode current (peak)... 210 A Duty cycle... 0.0006 Pulse duration (see note 12)... 3.0 ms VSWR at the output coupler... see note 10 Rate of rise of voltage pulse (see note 11)... 140 to 150 kv/ s Test Limits Anode voltage (peak)... 46 50 kv Output power (mean)... 2180 - W Frequency (see notes 11 and 12)... 2856 2859 MHz RF bandwidth at 6 db...- 1.0 MHz Stability (see notes 13 and 14)...- 0.5 % Frequency pulling (see note 13)...- - MHz Heater current... see note 15 Temperature coefficient of frequency... see note 16 Min Max e2v technologies (uk) limited 2013 Document subject to disclaimer on page 1 A1A-M5028 Version 7, page 2

END OF LIFE CRITERIA (Under the above Test Conditions, see note 17) Output power (mean) (see note 18)... 2180 W min RF bandwidth at 6 db... 2.0 MHz max Frequency (see note 14)... 2856 to 2859 MHz Stability... 1.0 % max NOTES 1. The frequency range 2856 to 2859 MHz is achieved under all conditions. The total available tuning range is 10 MHz. The frequency at any tuner setting will increase by 630 khz per kw reduction in mean input power. For other conditions, contact e2v technologies. 2. The magnetron must be protected from the load by an isolator or circulator. The maximum VSWR at 2856 MHz is 1.3:1 and must not exceed 2:1 over the range 2800 to 3500 MHz. 3. With no anode input power. Prior to the application of anode voltage, the cathode must be heated to the required initial temperature by the application of 13 V to the heater for at least six minutes. Within 30 seconds after the application of anode voltage the heater must be reduced as follows: Mean input power Heater voltage (kw) (V) 0-2 12.0 2-4 10.0 4-6 8.0 6-7 6.0 The heater voltage must be maintained within 5% of the specified value. A rectified supply is recommended for operating the magnetron. The use of any AC supply may cause frequency modulation. e2v technologies should be consulted if the magnetron is to be operated with any supply other than DC. A coaxial lead must be used to connect the magnetron to the filament transformer or pulse transformer, the outer being the cathode pulse connection. Capacitors must be used to prevent pulse voltages being applied to the heater, either from unbalance of a bifilar pulse transformer or by induction from the pulse current; this protection must be effective both for normal operation and in the event of the magnetron sparking. Capacitors up to 10 F may be required, shunted by small high frequency capacitors. 4. The minimum air pressure in the output waveguide can vary with the peak power level at which the magnetron is operated. It should not be less than 172 kpa at 1 MW, 241 kpa at 3 MW and 310 kpa at 5 MW. At the maximum pressure of 448 kpa the leakage will not exceed 0.03 litre (NTP) per minute. The output waveguide may also be filled with an arc suppressant gas, such as SF 6 to a minimum static gauge pressure of 28 kpa. When using such a gas, it is mandatory that the waveguide be emptied and refilled with new arc suppressant gas at regular intervals to avoid possible dilution or contamination. The interval should not exceed 2 months or 100 hours of high voltage application, whichever is reached first. The gas should also be replaced immediately if arcing in the output waveguide is suspected, as such arcing may cause loss of stability in the magnetron. 5. Measured at the point indicated on the electromagnet outline drawing; the axial distribution must be that produced by the MG6030 electromagnet or authorised equivalent. 6. The modulator must have an efficient overswing damping system, such that the pulse energy delivered to the magnetron following an arcing pulse does not appreciably exceed the normal pulse energy. An interlock relay must be used to trip the modulator in the event of excessive magnetron arcing, preferably operated by the overswing diode current. The trip should operate if the magnetron arcs for 25 consecutive pulses. Positive overswing at the end of the voltage pulse should be less than 10% of drive voltage. 7. The various parameters are related by the formula: Pi = i apk x V apk x Du where Pi = mean input power in watts i apk = peak anode current in amperes v apk = peak anode voltage in volts and Du = duty cycle 8. The rate of rise of voltage is defined as the steepest tangent to the leading edge of the voltage pulse above 80% amplitude. 9. Tolerance 10%. 10. The load termination of the magnetron during this test is a waveguide with a VSWR of less than 1.1:1 at the oscillation frequency and less than 1.5:1 between 3200 and 3500 MHz. 11. The magnetron tuning range includes the two limits given. 12. Using test conditions with a duty cycle of 0.00008 (1 kw mean input power), the lowest frequency obtained will not be greater than 2855 MHz). 13. Measured with a VSWR of 1.3:1 at the frequency of oscillation, varied through all phases. 14. Pulses are defined as missing when the RF energy level is less than 70% of the normal energy level in the frequency range 2852 to 2861 MHz. Missing pulses are expressed as a percentage of the number of input pulses applied during any 5 minute interval of a 10 minute test period. 15. Measured with a heater voltage of 13 V and no anode input power, the heater current limits are 13 A minimum, 15 A maximum. 16. Design test only. The maximum frequency change with anode temperature change (after warming) is 0.05 MHz/ C. 17. The heater will be operated at 8.0 V for the duration of the life test and for subsequent specification tests. 18. If the mean output power falls below 2500 W, the duty cycle may be reduced to 0.0005; end of life is reached when the magnetron is unable to deliver 5.0 MW peak power with a maximum mean current of 133 ma. e2v technologies (uk) limited 2013 Document subject to disclaimer on page 1 A1A-M5028 Version 7, page 3

TYPICAL PERFORMANCE CHART e2v technologies (uk) limited 2013 Document subject to disclaimer on page 1 A1A-M5028 Version 7, page 4

OUTLINE (All dimensions without limits are nominal) Ref Millimetres A 254.0 max B 222.3 max C 146.7 max D 33.02 3.18 E 57.15 max F 120.7 G 76.2 max H 116.2 J 144.5 K 101.6 max L 94.0 max M 190.5 Outline Notes 1. Heater-cathode connector is a UHF 50 coaxial socket; the corresponding plug is MIL STD PL259 with PTFE insulator. The cathode connection is the outer shell of the socket. 2. Splined shaft, to mate with S.S. White EX977 remote control flexible shaft. 3. Water connections 1/2-inch BS screwed pipe to BS 2051 part 2. 4. Radiation absorber MA761 optional accessory. e2v technologies (uk) limited 2013 Document subject to disclaimer on page 1 A1A-M5028 Version 7, page 5

HEALTH AND SAFETY HAZARDS e2v technologies magnetrons are safe to handle and operate, provided that the relevant precautions stated herein are observed. e2v technologies does not accept responsibility for damage or injury resulting from the use of electronic devices it produces. Equipment manufacturers and users must ensure that adequate precautions are taken. Appropriate warning labels and notices must be provided on equipments incorporating e2v technologies devices and in operating manuals. High Voltage Equipment must be designed so that personnel cannot come into contact with high voltage circuits. All high voltage circuits and terminals must be enclosed and fail-safe interlock switches must be fitted to disconnect the primary power supply and discharge all high voltage capacitors and other stored charges before allowing access. Interlock switches must not be bypassed to allow operation with access doors open. RF Radiation Personnel must not be exposed to excessive RF radiation. All RF connectors must be correctly fitted before operation so that no leakage of RF energy can occur and the RF output must be coupled efficiently to the load. It is particularly dangerous to look into open waveguide or coaxial feeders while the device is energised. Screening of the cathode sidearm of high power magnetrons may be necessary. X-Ray Radiation High voltage magnetrons emit a significant intensity of X- rays not only from the cathode sidearm but also from the output waveguide. These rays can constitute a health hazard unless adequate shielding for X-ray radiation is provided. This is a characteristic of all magnetrons and the X-rays emitted correspond to a voltage much higher than that of the anode. Toxic Material This device contains fluorinated elastomers (Viton O-rings). If exposed to temperatures above 400 C these degrade and form hydrofluoric acid. This is a serious health hazard if skin contact occurs. Access to these components is not possible unless the device is damaged or dismantled. e2v technologies (uk) limited 2013 Document subject to disclaimer on page 1 A1A-M5028 Version 7, page 6