Tougher than any challenge. Transformers for highcurrent. industrial applications. siemens.com/transformers

Similar documents
Power Transformers Basics

Industrial Applications

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Liquid-Filled Transformers

TRANSFORMER TECHNOLOGY GPT

Power transformers for Network, Rectifiers, Furnace

Repair & Retrofit new life for old transformers. Repair and retrofitting through TLM Transformer Lifecycle Management. Answers for energy.

LIQUID IMMERSED INDUSTRIAL TRANSFORMERS. For metallurgical, steel, chemical, glass plants and VSD TRANSFORMING THE FUTURE. seatrasformatori.

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

SHUNT REACTOR CORES Up to 765 kv MVAR

Basic Principles and Operation of Transformer

INTERNATIONAL STANDARD

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Siemens Transformer Technology Seminar Insulation & Thermal Design

nical catalogue Tech

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Convincing technology creates compact performance

Power Safety Quality

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

ABB Power Products Service

Electrical Design Process

K Factor Power Transformers

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Optimization of power transformers based on operative service conditions for improved performance

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

Transformers. GE Digital Energy. Three Phase up to 1500MVA. with Primary Plus TM

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Shunt Reactors for Medium and High-Voltage Networks

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

TECHNICAL INFORMATION

Problems connected with Commissioning of Power Transformers

Vacuum Interrupters for Medium Voltage

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Pomona, CA May 24 & 25, LTC Applications - Location, Series & Preventative Auto Transformers

PCS Working Group on General Requirements C

(2) New Standard IEEE P (3) Core : (4) Windings :

Ritz Instrument Transformers GmbH. Welcome

(

The Polytransformer. The Multivoltage Substation Power Transformer

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

POWER TRANSFORMERS CATALOGUE

CAST RESIN DRY TRANSFORMER

Hands-On Transformer Testing and Maintenance

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

PRODUCTS & ACCESSORIES FOR DISTRIBUTION TRANSFORMERS.

Aftermarket services, spares and retrofit. World-class support for world-leading variable pitch axial fans

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

Introduction. Centrado leading-edge transformer. Introduction

Phase Shifting Transformers. Presented by

Custom Power Supplies, Transformers, Chokes & Reactors

VARIAX AXIAL FLOW FAN AFTERMARKET SERVICES, SPARES AND RETROFIT HOWDEN DENMARK

TRAFO ELECTRIC P. LTD.

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

TMC Transformers TMC

MADE IN GERMANY INDUSTRIAL ENAMELLING DIES

Primary Test Manager (PTM) Testing and management software for primary assets

Content. Hot-dip galvanized narrow strip. Areas of application. Product information

Regional Technical Seminar SHORT CIRCUIT FORCES

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

Transformer Protection

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

HPS Universal BUCK-BOOST TRANSFORMERS

Transformer Technology Seminar What to consider at Design Reviews

HOW TO SAFE GUARD THE TRANSFORMER..???

Basic principles and operation of a transformer

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Recent Development of SFCL in the USA

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

On-Load Tap Changer Type M

OIL-IMMERSED ARC-SUPPRESSION COILS

siemens.com/transformers Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Western Mining Electric Association San Antonio TX Layer vs. Disk Windings Discussion NOVEMBER 15, SPX Transformer Solutions, Inc.

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System

Power Transformer Products & Services INCREASED PERFORMANCE & UPTIME

TRANSFORMER SERVICES OUR KNOWLEDGE. YOUR EXPERTS.

Transformer Protection

GOVERNMENT COLLEGE OF ENGINEERING, BARGUR

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

VACUTAP VR THE ALL-AROUND ON-LOAD TAP-CHANGER. TRANSFORMER CONTROL

Martin Stoessl R&D Manager Siemens Transformers Austria - Weiz

Electrical Submersible Pumping Systems

Totally Integrated Power SIVACON 8PS LDM busbar trunking system siemens.com/ldm-system

Design Improvement by Diagnostics of Transformers still in Operation and of Apparatuses taken out of Service

Mechanical Design. Brian Brinson Mechanical Design Manager.

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

2013 Applied Power Electronics Conference (APEC) Page 1 of 8

Transcription:

Tougher than any challenge Transformers for highcurrent and large drive industrial applications siemens.com/transformers

Powering industry Water-cooled LV-side high-current U-tube bushings Metallurgical and other industrial plant processes and large drive procedures depend on reliable highly specialized transformers. In steel plants, for example, it is crucial to supply high currents for AC and DC electric as well as ladle furnaces. Electrolysis processes to produce aluminum, copper, zinc, chlorine, and carbon operate with heavy-duty rectifiers, fed by rectifier transformers. Large drive mining applications and variable electrical speed drives depend on converter transformers to supply power to blast furnaces, pump stations, or rolling stock. Global demand and production capacities increase together. This calls for higher voltages and currents from powerful transformers to accommodate the most demanding requests and severe working conditions. The transformers are exposed to cyclic load and high thermal stress. They must withstand frequent overcurrent and overvoltage caused by short circuits in the furnace or tripped high-voltage circuit breakers. Because high currents cause enormous electromagnetic fields, special attention must be paid to prevent transformer overheating and system malfunctions. An outage can cause a total loss of industrial production, such as when pots or furnaces freeze. The outage costs can quickly threaten even large industries. Every single transformer must be precisely tailored to meet individual demands. Low-cost standard solutions can later become very costly for the industrial customer. Siemens industrial transformers have led the field for more than six decades, thanks to more than 100 years of experience in transformer technology and our unique expertise throughout the entire energy conversion chain. Our industrial customers rely on our transformers. In turn, they are the reason why we are here. Working conditions in a steel plant are tough even for transformers 2

Engineered for high performance Siemens transforms your individual requirements into the very highest quality power transformers that are well known worldwide for their many years of reliable operation. The open secret behind our reliability: quality Our high-quality standards are internationally recognized. All Siemens transformer manufacturing plants work with consistently certified quality management systems, including DIN ISO 9001:2000 and ISO 14001 among others. We manufacture all units in accordance with IEC or IEEE (ANSI) or other local standards. Upon customer request, we also adhere to ATEX certifications for our units. Above all, our high-quality standards are based on more than a century of experience in transformers, continual research, and unending development work. The competence center for special transformers in industrial applications is based in Germany. The selection, qualification, audit, and approval of global suppliers and materials as well as research and development are done here. This enables us to deliver made in Germany quality from all our plants. For more than 100 years, we ve partnered with well-known power supply and industrial companies around the world. We re ready to support you from transformer planning, design, and production to transport and commissioning. Naturally, we will continue to provide support and service after delivery and commissioning. Siemens Transformer Lifecycle Management efficiently and precisely carries out special customer requests, significantly increasing transformer service life. Minimizing risks by maximizing quality When industrial plants depend on transformer reliability as the starting point of their value chain, outage risk evaluation is a decisive buying factor. This is where Siemens excellent failure rates (FRe) history comes into play. The mean time between failure (MTBF) statistics of our transformer plants are impeccable and prove our excellence in the field. By selecting Siemens, you are choosing the safest solutions available. Cheaper transformers are expensive when they fail. The safety and reliability records of our products provide peace of mind. Ask for our latest MTBF figures and you ll see why. 3

Furnace transformers for steel plants Siemens offers AC and DC electric arc furnace transformers to provide high currents (up to 180 ka) for the electric arc. They are specifically designed to withstand the exceedingly severe conditions of the metallurgical steel melt processes in: foundries secondary steelmaking ferroalloy production Technical features: ratings up to 300 MVA secondary voltage up to 2 kv electrode current for steel up to 120 ka electrode current for ferroalloy up to 180 ka Low-voltage connection copper plate Producing 80 tons of steel requires more than 35,000 kwh of power and 44,000 amperes of current. It takes 50 minutes to charge, melt, refine, de-slag, and tap each batch of steel. Following each cycle, it should take 60 minutes or less to repeat the process, tap-to-tap. Melting processes require enormous currents and have extraordinarily severe working conditions. They work under high operation currents that are often close to their short-circuit values. At the same time, melting processes face frequent on- and off-switching and tap changes during operation. But, despite being stressed to their limits, an unplanned outage of a furnace transformer has enormous financial impact and should be prevented at all costs. This calls for extremely robust and reliable transformers. Design options: Direct or indirect regulation or booster On-load or off-load tap changer Oil or vacuum type OLTC (also reactor type OLTC) Series reactor (built-in or separate) for long arc stability Air or water-cooled secondary bushing arrangements and designs Internal secondary phase closure (internal closed delta) Special magnetic shield design for each project OF- or OD-cooling Combining with a series reactor is recommended for improved efficiency and clear and stable reactance, either as a stand-alone unit or incorporated into the tank of the EAF transformer. 4

Rectifier transformers for electrolysis processes To produce 1,000 kg of 99.99% aluminum, a furnace of 1,200 C is required to achieve a 950 C melting temperature. The precondition to achieve the melting point is 100,000 amperes direct current and 1,000 voltage power provided by a 120 MVA rectifier transformer. Technical features: Ratings up to 225 MVA Secondary voltage 2 kv to nearly 0 V depending on the application Design options: Direct or indirect voltage regulation Double-star or double-bridge connection Double-tier design and/or keel line arrangement Double-tier with or without intermediate yoke On-load or off-load tap changer Filter connection or filter winding Additional phase-shifting windings for 12 or higher pulse systems Interphase reactor, saturable reactors (transductors) Air-cooled secondary bushing arrangements and designs Numerous different vector groups and phase shifts Rectifier transformer in test field 5

Converter transformers for large drive applications HV-side of a converter transformer ready to be shipped Transformers for large drive applications supply the input for variable speed drives, such as in large-scale industry drives, pump stations, rolling stock applications, or blast furnaces. Multi-pulse rectifier operation (up to 36) is required. When operating large drives, each converter transformer has a specific voltage and insulation level, depending on the industry application. Harmonics must be reduced and shortcircuit currents limited. The output frequency requires flexibility, including the transformer s ability to cope with different load cycles and ability to adapt to meet the drive input voltage. Technical features: Ratings up to 200 MVA Secondary voltage between 800 V and 36 kv depending on the drive Additional winding enables filter for harmonics to be added Combined with a frequency converter Design options: Double- or multiple-tier design On-load or off-load tap changer Filter winding and/or earth screen Numerous different vector groups and phase shifts Variable-speed drive design ATEX certification Operation in harsh environment Pfisterer Connex LV bushings 6

Your benefits at a glance: Tailor-made industry transformers for every kind of application Comprehensive rating range Superior technical design including cost-saving delta connection Low failure rate Outstanding quality (we welcome a challenge) Exceptionally long service life Extended warranty periods possible Global production and service network, including delivery 7

Built to last: components and accessories The core The iron core forms the central element of every Siemens transformer. Highgrade, cold-rolled, and laser-treated metal sheets, with thicknesses of 0.3 mm or less, are precision-cut with computer-controlled machines to comply with even the smallest tolerance requirement. The individual sheets are then manually assembled into cores using the step-lap technique. This provides an especially good flux distribution at the joints, resulting in exceptionally low losses and minimal no-load noise. For heavy duty rectifier and converter transformers with multi-pulse winding systems in a double-tier arrangement, the core can be designed with an intermediate yoke for winding system decoupling. When the transformer core is ready for installation, a hydraulic platform moves the core into a vertical position where the windings are then assembled. The windings Transformer windings are subject to continuously high electrical and mechanical loads. Disk and cylindrical coils with transposed copper wire conductors guarantee high mechanical strength and highly reliable operation. Disk coils for high voltages consist of continuously wound coils that are divided by radial and axial channels for oil cooling. They are manufactured on vertical and horizontal winding lathes. Thanks to the continuous winding of the disk coils, the number of soldering points is reduced to a minimum. Precise control systems ensure constant contact pressure and winding tension. Experienced coil winders monitor every step. Multilayer windings for low voltages consist of concentrically superimposed cylindrical coils separated by axial oil ducts. Furnace transformer windings can be cooled directly (OD-cooling method) by specially arranging the oil ducts, optimizing heat dissipation out of the windings. This also provides a compact design. After winding, the coils are pressed, dried under constant pressure, impregnated with oil, measured exactly, and geometrically adjusted if required. Voltage control Grid and generator voltages can vary significantly from the rated values because of external influences. Siemens transformers facilitate adapting the voltage to grid conditions. The voltage can be changed in the de-energized state with a de-energized tap changer or adjusted in steps under load using on-load tap changers. High ratings or high HV voltage levels can put the switching capacity and the step voltage of the OLTCs to extremes. However, when a technical solution for direct regulation is either not economically viable, or impossible, an auto-transformer or booster and OLTC within an intermediate circuit can be used as the solution. On-load tap changers and optionally de-energized tap changers are fitted with motorized drives and can be controlled on-site or remotely. 8

The tank High-grade, quality-assured tanks define the appearance of our transformers. This protective shell accommodates the core, winding assembly, and insulating oil. When combined, these components often weigh more than 100 tons. Therefore, the tank should not add unneeded weight. However, the tank must be structurally sound, leak-proof, and must withstand mechanical stress. First-class corrosion protection is therefore a basic requirement for long tank life. Special attention is paid to prevent impermissible transformer heating or monitoring system malfunction due to internal and external magnetic fields. This requires special shielding. Cooling The cooling system ensures heating levels do not reach maximum levels and avoids hot spots in the transformer. Various methods of cooling can be used, depending on the individual service conditions, to guarantee reliable and problem-free operation for many years. Most noteworthy are the ONAN, ONAF, OFAF, and ODAF oil-air cooling and OFWF and ODWF oil-water cooling systems. Radiator banks and oil-air and oil-water coolers can be attached to the transformer or installed separately. Financing Siemens Financial Services offers customized financial solutions. It clears the way for liquidity-preserving investments in innovative products, as well as complete solutions, service, and consulting guidance. There are different options including leasing, hire purchase, structured financing, private equity, project and equity participations, as well as project and expert financing. Siemens Transformers and Financial Services offer the benefits our customers require around the world, including attractive technical solutions and perfectly tailored financing. Together, we ensure our customers are successful in their business. 9

References Furnace transformers 33 kv ladle furnace transformer for steel plants in India. Main technical features: 20 MVA, forced oil cooling with an oil-to-water heat exchanger, max. secondary currents > 40 ka Rectifier transformer 110 kv transformer with interphase reactors and saturable reactors and a rating of 42.5 MVA for an electrolysis process in the chemical industry. Converter transformer ATEX-certificated 33/4x2 kv 24-pulse converter transformer for oil and gas application in Abu Dhabi. Main technical features: 16/4x4 MVA, biodegradable insulation fluid for high fire safety, and core with intermediate yokes. Furnace transformers 34.5 kv furnace transformer at 100 MVA for a steel plant in the United States. The challenge in this project was to achieve a higher performance level than the previous unit had by maintaining the dimensions. Rectifier transformer Three units with several ratings (132 kv / 10 kv) at 46.8 / 23 MVA. The units include an interface reactor and two rectifiers with six transductors each as well as an autotransformer with a 3-to-1 phase on-load tap changer in one tank. 10

11

Published by Siemens AG 2017 Energy Management Freyeslebenstrasse 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.energy@siemens.com Printed in Germany Dispo 19200 fb 7491 WS 0417 Printed on elementary chlorine-free bleached paper. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.