www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

Similar documents
www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

These drawings and single line diagrams provide an outlook of Basler Electric solutions for Excitation System installations and retrofit

Hands On Relay School Open Lecture Transformer Differential Protection Scott Cooper

Centralized busbar differential and breaker failure protection function

PD300. Transformer, generator and motor protection Data sheet

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

Generator Protection M 3420

Bus Protection Fundamentals

Unit Protection Differential Relays

g GE POWER MANAGEMENT

Power System Protection Manual

System Protection and Control Subcommittee

Transformer protection IED RET 670

PROTECTION OF TRANSFORMERS M-3311A TEST PLAN

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

Protective Relays Digitrip 3000

Generator Protection M 3425

Catastrophic Relay Misoperations and Successful Relay Operation

Transformer Protection Principles

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Multimeter 500CVD21 RTU500 series

Differential Protection with REF 542plus Feeder Terminal

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

Transformer Protection

2015 Relay School Bus Protection Mike Kockott March, 2015

BUS2000 Busbar Differential Protection System

Generator Protection GENERATOR CONTROL AND PROTECTION

EASUN REYROLLE LIMITED

Improving Transformer Protection

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner

Transformer Protection

Phase and neutral overcurrent protection

Stabilized Differential Relay SPAD 346. Product Guide

Instruction Book. M-3425A Generator Protection

Instruction Book. M 3425A Generator Protection

EEL 3086 SWITCHGEAR AND PROTECTION EXPERIMENT 2 DIFFERENTIAL PROTECTION OF A THREE-PHASE TRANSFORMER

SIPROTEC. Multi-Functional Generator Protection Relay 7UM61. Preface. Contents. Introduction 1. Functions 2. Mounting and Commissioning 3

Power systems Protection course

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

ENOSERV 2014 Relay & Protection Training Conference Course Descriptions

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

Relaying 101. by: Tom Ernst GE Grid Solutions

FMR. Ultra Line FEEDER MANAGER RELAY

7PG2113/4/5/6 Solkor Feeder Protection Answers for energy

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Digital Line Protection System

889 Advanced Generator Protection Technical Note

Type: ADR233A (ADITYA V2 Series) (Preliminary) ASHIDA Numerical 3 Phase Tx. Differential Protection Relay

PROTECTION of electricity distribution networks

Protecting Large Machines for Arcing Faults

NERC Protection Coordination Webinar Series July 15, Jon Gardell

Substation applications

Modular range of digital protection relays

Waterpower '97. Upgrading Hydroelectric Generator Protection Using Digital Technology

Transformer Fault Categories

Detecting and Managing Geomagnetically Induced Currents With Relays

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

Distributed busbar differential protection function and breaker failure protection

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Generator Protection M 3425A

Power System Protection Part VII Dr.Prof.Mohammed Tawfeeq Al-Zuhairi. Differential Protection (Unit protection)

Overcurrent Elements

COPYRIGHTED MATERIAL. Index

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Impact of transient saturation of Current Transformer during cyclic operations Analysis and Diagnosis

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

FUJI Inverter. Standard Specifications

g GE POWER MANAGEMENT

489 Generator Management Relay Instruction Manual

MiCOM P642, P643 and P645

Transformer differential protection

3 Pole high impedance differential relay 7VH83

Pinhook 500kV Transformer Neutral CT Saturation

ULTRA RAPID POWER QUALITY ANALYZER

Motor Protection. May 31, Tom Ernst GE Grid Solutions

Digital Motor Bus Transfer System M 4272

489 Generator Management Relay

DPX³ 250 Electronic 4P - ModbusTable LGR EN v1.01.xls

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

High-Tech Range. IRI1-ER- Stablized Earth Fault Current Relay. C&S Protection & Control Ltd.

Inrush3 Three-Phase Transformer Inrush and Motor Start-Up Current Detector

Capacitor protection relay

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

High speed bus transfer function block description Operation Manual

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

GPM. Field and Stator Ground Fault Protection Modules. Instruction Manual AF1. GE Grid Solutions

- Protective & control functions

Supplemental Motor Protection Devices Specifications

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Minnesota Power Systems Conference 2015 Improving System Protection Reliability and Security

Impact of Incipient Faults on Sensitive Protection

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

Transcription:

Generator Differential Relay The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor based protective relays. The MD3G relay offers the following functions: Differential elements (87G) for each phase with multi-slope bias characteristics and selectable slope breakpoint. Trip response time of less than cycles. The MD3G is suitable for protecting generators or other rotating machines. Phase overcurrent for stator protection (51P). Restricted ground fault element. Instantaneous and low set ground fault protection. Depending upon the input circuit configuration, either stator ground fault (51GN) or sensitive ground fault (87N) protective functions may be implemented. Breaker fail (50BF). 16 cycle oscillographic records of trip events. An oscillographic record may also be triggered externally. The MD3G also shares the following features common to all Edison relays: Simple five button man machine interface (MMI) allows access to all functions, settings, and stored data without the need for a computer. Bright electroluminescent display easily visible even in brightly lit environments. August 1997 New Issue Printed in USA Draw-out design permits relay testing without disturbing connections to case. Modbus communication protocol and RS485 terminal on rear. Modular design allows the draw-out module to be fitted to a variety of space saving cabinet styles. Three programmable Form C (SPDT) output contacts and one Form A/B contact. Pick-up (start-time) elements. Programmable reset characteristics. Dedicated power supply/relay fail output contacts. Electrical Apparatus MD3G Rotating Machine Differential Relay 150-3 Figure 1. Front View of the MD3G Generator Differential Relay Applications The MD3G is ideally suited for the protection of generators and large motors against two or three phase internal faults, inter-turn faults, and ground faults in equipment with low-impedance or solidly grounded neutrals. Its multi-slope percentage bias characteristic allows for compensation of CT ratio error mismatch and differences in CT response. For autotransformer-started motors, some differential protection schemes include the autotransformer in the zone of protection. In this case rotating machine differential relays such as the MD3G are not suitable as the nd and 5th harmonic restraint functions common to transformer differential relays are required. For this application, the MD3T relay should be used. 1

MD3G Rotating Maching Differential Relay Figure. Dual Slope Bias Characteristic of the MD3G Differential Relay Multi-slope Biased Differential Element Each phase is provided with its own differential element having a characteristic as shown in Figure. The relay internally calculates the RMS value of the differential current compensated for any CT ratio and phase angle mismatch. The minimum differential current required for operation is adjustable between 0.0 and 0. pu of the machine s rated current. This setting is fixed up to 0.5 pu of the machine s rated current. Above 0.5 pu compensation of the set point is required for CT saturation which may occur at higher current levels. The slope of each of the two sloping portions of the characteristic are adjustable, as is the breakpoint between the two slopes. The first slope may be adjusted from % to 0%, and applies from 0.5 pu of the machine s rated current, up to the Is/In 8 0. 0.1 Id/In 0 1 I R 0.5 1 P 3 3 I R Id Is= Effective relay s operation differential current Id= Relay s setting differential current Id IRIn breakpoint, which may be set from 1 to 3 pu. Above the setpoint the slope of the differential element is adjustable between 5% and 50%. Overcurrent Protection A single definite time delay phase overcurrent element is provided to act as overload backup protection. Ground Fault Protection To provide greater coverage for ground faults, the MD3G monitors the fundamental frequency component of current fed into the ground element inputs. Depending upon the connection, this element can perform: Sensitive ground fault protection (87GN). Neutral current protection (stator ground fault) (51N). 4 The 87GN connection is suitable for large generators, or for situations where a number of smaller Id R% = (I 100 = 1 -I ) 100 I R (I 1 -I )/ 1 3 4 Is = I7 In In Is I = d In In Is = In Is In I R + ( In 1R% 0.5) 100 I d (P-0.5)1R% + + ( In 100 8 generators are connected in parallel through a common step up transformer. This connection (shown in Figure 3) allows for very sensitive settings to be made and restricts the element to operate within the zone of the differential element. This ground fault element consists of a definite time high set element. Breaker Fail I R -P) In 1 A programmable time delay is set equal to the breaker clearing time. If the fault is not cleared (i.e., the trip element has not dropped out), before this timer expires, a breaker fail is indicated. The breaker fail element may also be programmed to monitor any combination (or none) of the following elements; differential, phase overcurrent, or ground fault. The breaker fail function may be assigned to operate one or more of the output relays.

Targets Eight bright LED targets are provided as follows: One red LED for each of the three phase differential elements. One red LED for the restricted ground fault element. One red LED for the breaker fail element. One red LED for the phase overcurrent element. For all of the above, the LEDs flash when the element is picked up, and constantly illuminate upon trip. In addition, one yellow LED is provided which illuminates when the blocking input is active. A second yellow LED flashes when the relay is in programming mode, and illuminates constantly upon relay or power supply failure. Blocking Input An opto-isolated programmable blocking input is provided. This input may be programmed so that when activated, any combination of the differential, phase overcurrent, or ground fault elements may be blocked. While the blocking input is active, the pickup of any element associated with the blocking input is prevented. Sensing of the input quantities and the countdown of any timers begins only when the blocking is removed. Reset Characteristic The programmable output relays may be programmed to reset in one of two manners. Instantaneously upon the input or calculated quantities dropping below the pickup value. Manual reset (by front panel or computer command) only. Measurements and Inrush Values The following quantities are continuously monitored and are available for display at the relay and are accessible by software: RMS values of each phase s differential current. Fundamental frequency component of the neutral current in per unit of the rated phase current. RMS values of the three high side currents. RMS values of the three low side currents. In addition, the maximum values of each of these quantities during the first 100 msec after transformer energization is also recorded. This makes it convenient to quickly review the inrush currents associated with the most recent energization. Last Trip Record The following parameters are stored in non-volatile memory, providing details of the last five trip events: Which element was the cause of the last trip. The values of all measured currents at the time of trip. In addition, the relays keep a cumulative total of the cause of all breaker trips. Oscillography The MD3G stores two oscillographic records which are made available for downloading to a PC for graphing. All six input phase currents are recorded. Each oscillographic record consists of 8 pre-trigger and 8 post-trigger cycles, for a total of 16 cycles. The waveform is sampled at 1 samples per cycle. Storage of an oscillographic record may be programmed to occur automatically every time a protective element trips, or to occur only upon an external trigger. 150-3 Output Elements The following functions may be programmed to one or more of the output relays. The only limitation is that pick-up and time delay functions may not be assigned to operate the same output relay(s). Differential element. Phase overcurrent pickup element. Phase overcurrent time delayed element. Ground fault pickup element. Ground fault time delayed element. Breaker fail element. Diagnostics Complete memory and circuit diagnostics are run upon powering the relay. The revision level of the firmware is displayed at this time. The relay runs a comprehensive set of diagnostics every 15 minutes that includes memory checksum, test of the A/D converters by injection of an internally generated reference voltage, and a check of the ALU. The relay provides two manual test routines which may be run at any time. The first routine performs the same 15 minute test and in addition checks the target LEDs and the control circuitry to the output relays without operating the output relays. The second test is identical but also operates the output relays. Dimensions and Electrical Specifications See Catalog Section 150-05 for electrical specifications and dimensional information on all Edison relays. 3

Figure 3. Wiring Diagram for the MD3G Rotating Machine Differential Relay used for 87G and 87GN Protection 4

150-3 Figure 4. Wiring Diagram for the MD3G Rotating Machine Differential Relay used for 87G and 51N Protection 5

MD3G Rotating Maching Differential Relay TABLE 1 Functional Specifications Nominal system frequency setting range...50 or 60 Hz Programmable rated primary input current of phase CTs...1-9999A in 1A steps Breaker fail (50BF) time delay...0.05 to 1.00 seconds in 0.01 second steps Differential Element (87G) Minimum pick-up level of low set differential element...0.0 to 0.0 pu of rated CT current in 0.01 pu steps Bias percentage slope from 0.5 pu to P pu of rated CT current... - 0% in 1% steps Bias percentage slope at greater than P pu of rated CT current...5-50% in 1% steps Bias slope break point P...1.00 to 3.00 pu of rated CT current in 0.01 pu steps Overcurrent Element (51P) Minimum pick-up level...0.50 to 10.00 pu of rated CT current in 0.01 pu steps Time delay...0.05 to 99.00 seconds in 0.01 second steps Ground Fault Element Minimum pick-up level...0.01 to 1.00 pu of rated CT current in 0.01 pu steps Time delay...0.0 to 9.99 seconds in 0.01 second steps Ordering Information Construct catalog number from Table. Example: MD3GL5JS is an MD3G with low range power supply, 5A CT inputs, in a single relay case. If ordering two or more relays to be fit in a common case, the first relay ordered should indicate the case style desired. This relay will be located in the leftmost bay of the case. Subsequent relays should use the C, C3, or C4 suffixes to denote their position in the case using the leftmost bay as a C1 reference. TABLE Catalog Numbers Description Base Relay 1997 Cooper Power Systems, Inc. Edison is a registered trademark of Cooper Industries, Inc. Catalog Number MD3G To the above add one each of the following applicable suffixes Power Supply 1 4-110V AC/DC L 90-0V AC/DC H Rated CT Input 1A 1 5A 5 Modbus Protocol Case Style Draw out relay only, no cabinet supplied D Single relay case S Double relay case T 19" Rack mount cabinet N Mounting Position Denotes mounting position in either a double case or 19" Rack along with other relays ordered at the same time. 1 The power supplies are user replaceable and interchangeable. See Catalog section 150-99. The relay itself may be drawn out of any of the listed cases and plugged into any of the other case styles. The catalog number specified during ordering denotes the type of cabinet in which the relay will be shipped. Printed on Recycled Paper J C C3 C4 P.O. Box 1640, Waukesha, WI 53187 http://www.cooperpower.com/