Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

Similar documents
A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC Test report for LED Panel Light Models , , , , ,

2620 Modular Measurement and Control System

Australian Standard. Electricity metering equipment (AC) Particular requirements. Part 22: Static meters for active energy (classes 0.2 S and 0.

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC Test Report. Report Number: M030826

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

ARBITER 1133A POWER SENTINEL TEST IEC 687 CERTIFICATION TESTS DTC LABORATORY TEST REPORT

LS200 TEST DATA IEC61000 SERIES

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

Communication Certification Laboratory

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

FCC & IC Certification. Test Report. FCC & Industry Canada Certification. Test Report. for Hetronic USA FCC ID: LW9-CS434TXN IC ID: 2219A-CS434TXN

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Test Report GUANGDONG EAST POWER CO., LTD

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC standards. Presented by: Karim Loukil & Kaïs Siala

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

For the National Voluntary Laboratory Accreditation Program

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

TEST REPORT... 1 CONTENT...

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

EMC VERIFICATION SUMMARY Report No.: SZHH

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

TEST REPORT. Power Spout PLT V. tested to the specification

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

FCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB

Test Laboratory No Accredited by CAI for Electromagnetic Compatibility, Electrical Safety and Electrical Cable Tests

PT. SARANA KARYA SOLUSINDO.

FISCHER CUSTOM COMMUNICATIONS, INC.

Australian Standard. Electricity metering equipment (ac) Particular requirements. Part 23: Static meters for reactive energy (classes 2 and 3)

FCC PART 15 B MEASUREMENT AND TEST REPORT

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

EMC TEST REPORT. Report No.: CE10-LIE040101E

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EN v2.1.1 EN 55022: A1:2007 TEST REPORT FOR b/g/n 1x2 SISO NETWORKING DEVICE MODEL NUMBER: UNIFI AP MINI

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

Verification of Conformity On Behalf of

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

Report Of. Shielding Effectiveness Test For. DefenderShield. Test Date(s): September 1 October 2, 2012

Test Report GUANGDONG EAST POWER CO., LTD

Appendix A: Specifications

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

CONFORMANCE TEST REPORT FOR EN /-6

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer)

FCC 47 CFR PART 15 SUBPART B

TABLE OF CONTENTS 1.GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY...4

Satec Ltd. 3-Phase Power Meter PM135

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

Global EMC Labs EMC / EMI Test Report

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

TEST REPORT. Report Number: MPK-007 Project Number: Report Date: August 31, 2007

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Test Report According to EN V1.9.2; EN V Starcom GPS Systems Ltd.

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

TRANSMITTER MODEL: KAS-2030M

Emerging Standards for EMC Emissions & Immunity

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

RF Test Report. Report No.: AGC EE13 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Transcription:

PSL Standards Lab 980 Atlantic Avenue Alameda, CA 94501 USA TEL ++1-510-522-4400 FAX ++1-510-522-4455 www.standards.com Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report IEC 62053-22 Electricity metering equipment (a.c.) Particular requirements Static meters for active energy (classes 0,2 S and 0,5 S) Section 8: Accuracy Requirements

IEC Class 0,2 S Accuracy Certificate PSL Standards Lab 980 Atlantic Avenue Alameda, CA 94501 USA TEL ++1-510-522-4400 FAX ++1-510-522-4455 www.standards.com Sensors Ltd. PQube 3 AC Analyzer IEC 62053-22, Section 8 (accuracy requirements) Equipment Under Test was equipped with the following accessories or options: CTI-5A module and PM1 power supply module Certified at 230V L-N, 50 Hz, 5A rated IEC 62053-22 Section Test Result 8.1 Variation of with balanced load (positive energy flow) 8.1 Variation of with balanced load (negative energy flow) 8.1 Variation of with single-phase load (positive energy flow) 8.1 Variation of with single-phase load (negative energy flow) 8.1 Difference in between single-phase load and balanced polyphase load 8.2 Influence quantity: ambient temperature 8.2 Influence quantity: voltage variation 8.2 Influence quantity: frequency variation 8.2 Influence quantity: reversed phase sequence 8.2 Influence quantity: auxiliary voltage (does not apply to ) 8.2 Influence quantity: harmonic components 8.2 Influence quantity: sub-harmonics 8.2 Influence quantity: magnetic induction (dc) 8.2 Influence quantity: magnetic induction (ac) 8.2 Influence quantity: electromagnetic RF fields 8.2 Influence quantity: operation of accessories (does not apply to ) 8.2 Influence quantity: conducted disturbances 8.3.1 Initial start-up 8.3.2 No-load condition 8.3.3 Starting 8.4 Meter constant (does not apply to ) Tests were performed on a single sample of PSL PQube 3 AC Analyzer, S/N P3001592. Manufacturer states that the tested sample is representative of Model PQube 3. Contact the manufacturer for further information regarding Section 8.2 fast transient burst and damped oscillatory waves immunity. This Class 0,2 S Accuracy Certificate summarizes the results of the PSL IEC Class 0,2 S Accuracy Compliance Report, document #PSL IEC 62053-22 Ed 1 Test Report PQube 3, dated 12 May 2015. Signed: PSL PQube 3 AC Analyzer Name: Matthew Muh Title: Senior Engineer, Standards Lab Date: 12 May 2015 Page 2 of 19

Test category IEC 62053-22 Ed. 1, Class 0,2 S and Class 0,5 S Accuracy (Section 8) Equipment under test manufacturer: Sensors Ltd. model: PQube3-PQ-E08N-0000 with CTI-5A module serial number: P3001592 (PQube-3), M3002120 (CTI-5A) firmware version: 3.3ZCR9, 3.3ZCR10 Accessories included in test: PM1 power supply module (S/N M3001019) Test parameters Test locations: Standards Lab, Alameda, California, U.S.A. ITC Engineering Services, Sunol, California, U.S.A. Test dates: April 14, 2015 to April 27, 2015 Ambient temperature: 21 C to 25 C Supervising engineer: M. Muh Connection type: Wye (three-phase plus neutral), CTI-5A outputs connected to PQube-3 channels L1, L2, L3 Loading for accuracy tests: Polyphase or series-parallel (where noted) Duration of Wh measurement: 2 minutes minimum (unless otherwise noted) Wh/pulse value: 1.0 Basic specifications for test voltage (Un): Rated (In): Maximum (Imax): Rated frequency: 230 V L-N 5 A 6 A (= 1.2 In) 50 Hz Testing notes The CTI-5A module under test is a pre-production unit which is representative of, but not identical to, the forthcoming production unit. According to our engineering judgment, any differences between the preproduction unit and the forthcoming production units have a negligible effect on the performance and accuracy of the CTI-5A module. The accuracy of the s watt-hour pulse output is dependent upon the duration of the watt-hour measurement. Except where otherwise noted, a two-minute measurement was taken, which results in a maximum uncertainty of less than 0.02% due to the pulse output. This uncertainty is minimal relative to the typical limits of IEC 62053-22. The typical accuracy of the reference energy standard is 0.01%, with a maximum worst-case specification of 0.04% across its entire operating range. This specification is sufficient to meet the accuracy requirements of IEC 62053-22. Page 3 of 19

Description of test setup See Figure 1 below. A multi-channel 16-bit analog output board (NI PCI-6733), coupled to PSL-written waveform generation software, is used to generate balanced, three-phase sinusoidal voltage signals. These voltage signals are applied to the inputs of three high-voltage amplifiers (Trek 2210), creating programmable voltage sine waves at 230V, 50Hz. The outputs of these amplifiers are applied to the voltage measuring terminals of the. The same 16-bit analog output board is used to generate another set of three-phase sinusoidal voltages signals, which are applied to the inputs of three transconductance amplifiers (Fluke 5220A). These amplifiers convert the applied voltage inputs to three proportional outputs, which are connected to the inputs of the CTI-5A module. The three voltages applied to the voltage measuring terminals, as well as the three s applied to the module, are connected to the reference energy standard (Radian RD-30). The energy (Wh) readings from the are compared to the reference meter reading by means of the watt-hour pulse (KY) output. Figure 1: Simplified diagram of test setup for polyphase loading Page 4 of 19

Due to practical equipment limitations, the tests performed at the external testing site (ITC Engineering Services) were carried out with the and reference meter configured for series-parallel loading (i.e., connections in series and voltage connections in parallel). See Figure 2 below. Figure 2: Simplified diagram of test setup for series-parallel loading Page 5 of 19

Photo 1: Test setup Photo 2: Close-up of in test environment Page 6 of 19

Photo 3: Example of test setup for magnetic induction (d.c.) influence quantity test Photo 4: Example of test setup for magnetic induction (a.c.) influence quantity test Page 7 of 19

8.1 Limits of due to variation of the Table 4 Percentage limits (single-phase meters and polyphase meters with balanced loads) Positive energy flow Percentage limits for meters of class 0.01 I n 0.11% ±0.40% ±1.00% 0.02 I n 0.07% 0.05 I n 0.04% 0.1 I n 1 0.02% 0.5 I n -0.02% ±0.20% ±0.50% I n -0.03% I max -0.04% 0.02 I n 0.17% ±0.50% ±1.00% 0.05 I n 0.12% 0.1 I n 0.5 0.11% 0.5 I n inductive -0.01% ±0.30% ±0.60% I n 0.02% I max 0.04% 0.02 I n 0.07% ±0.50% ±1.00% 0.05 I n 0.04% 0.1 I n 0.8 0.02% 0.5 I n capacitive -0.05% ±0.30% ±0.60% I n -0.07% I max -0.07% Negative energy flow Percentage limits for meters of class 0.01 I n 0.04% ±0.40% ±1.00% 0.02 I n 0.04% 0.05 I n 0.04% 0.1 I n 1 0.02% 0.5 I n -0.04% ±0.20% ±0.50% I n -0.04% I max -0.02% 0.02 I n 0.10% ±0.50% ±1.00% 0.05 I n 0.09% 0.1 I n 0.5 0.06% 0.5 I n inductive -0.01% ±0.30% ±0.60% I n 0.01% I max 0.02% 0.02 I n 0.05% ±0.50% ±1.00% 0.05 I n 0.02% 0.1 I n 0.8-0.01% 0.5 I n capacitive -0.06% ±0.30% ±0.60% I n -0.07% I max -0.08% Page 8 of 19

Table 5 Percentage limits (polyphase meters carrying a single-phase load, but with balanced polyphase voltages applied to voltage circuits) Current phase L1 L2 L3 Current phase L1 L2 L3 Positive energy flow Percentage limits for meters of class 0.05 I n 0.04% 0.5 I n -0.01% 1 ±0.30% ±0.60% I n -0.03% I max -0.02% 0.1 I n 0.03% 0.5 I n -0.01% 0.5 inductive ±0.40% ±1.00% I n 0.02% I max 0.02% 0.05 I n 0.06% 0.5 I n -0.05% 1 ±0.30% ±0.60% I n -0.06% I max -0.06% 0.1 I n 0.06% 0.5 I n -0.03% 0.5 inductive ±0.40% ±1.00% I n -0.04% I max -0.02% 0.05 I n 0.04% 0.5 I n -0.03% 1 ±0.30% ±0.60% I n -0.03% I max -0.03% 0.1 I n 0.08% 0.5 I n -0.01% 0.5 inductive ±0.40% ±1.00% I n 0.04% I max 0.06% Negative energy flow Percentage limits for meters of class 0.05 I n 0.06% 0.5 I n -0.03% 1 ±0.30% ±0.60% I n -0.02% I max -0.02% 0.1 I n 0.06% 0.5 I n -0.02% 0.5 inductive ±0.40% ±1.00% I n -0.01% I max 0.03% 0.05 I n 0.03% 0.5 I n -0.06% 1 ±0.30% ±0.60% I n -0.05% I max -0.05% 0.1 I n 0.04% 0.5 I n -0.06% 0.5 inductive ±0.40% ±1.00% I n -0.02% I max 0.01% 0.05 I n 0.07% 0.5 I n -0.01% 1 ±0.30% ±0.60% I n -0.03% I max -0.04% 0.1 I n 0.07% 0.5 I n 0.01% 0.5 inductive ±0.40% ±1.00% I n 0.05% I max 0.08% Page 9 of 19

The difference between the when the meter is carrying a single-phase load and a balanced polyphase load at rated In and unity power shall not exceed 0.4% and 1.0% for meters of classes 0,2 S and 0,5 S respectively. Positive energy flow Percentage limits for Difference between Current phase with single-phase with balanced meters of class s load polyphase load L1-0.03% -0.00% L2-0.06% -0.03% -0.03% ±0.40% ±1.00% L3-0.03% -0.00% Negative energy flow Percentage limits for Difference between Current phase with single-phase with balanced meters of class s load polyphase load L1-0.02% 0.03% L2-0.05% -0.05% 0.00% ±0.40% ±1.00% L3-0.03% 0.02% Page 10 of 19

8.2 Limits of due to influence quantities Ambient temperature variation at 65 C at 45 C Mean temperature coefficient from 65 C to 45 C Limit for meters of class 0.05 I n 0.18% 0.12% -0.003 %/ C I n 1 0.10% 0.02% -0.004 %/ C ±0.01 %/ C ±0.03 %/ C I max 0.11% 0.01% -0.005 %/ C 0.1 I n 0.28% 0.16% -0.006 %/ C 0.5 I n 0.18% 0.06% -0.006 %/ C ±0.02 %/ C ±0.05 %/ C inductive I max 0.16% 0.11% -0.003 %/ C at 45 C at 25 C Mean temperature coefficient from 45 C to 25 C Limit for meters of class 0.05 I n 0.12% 0.02% -0.005 %/ C I n 1 0.02% -0.08% -0.005 %/ C ±0.01 %/ C ±0.03 %/ C I max 0.01% -0.07% -0.004 %/ C 0.1 I n 0.16% 0.04% -0.006 %/ C 0.5 I n 0.06% -0.03% -0.005 %/ C ±0.02 %/ C ±0.05 %/ C inductive I max 0.11% -0.01% -0.006 %/ C at 40 C at 20 C Mean temperature coefficient from 40 C to 20 C Limit for meters of class 0.05 I n 0.09% -0.01% -0.005 %/ C I n 1-0.01% -0.10% -0.005 %/ C ±0.01 %/ C ±0.03 %/ C I max 0.01% -0.10% -0.006 %/ C 0.1 I n 0.13% 0.03% -0.005 %/ C 0.5 I n 0.07% -0.05% -0.006 %/ C ±0.02 %/ C ±0.05 %/ C inductive I max 0.10% -0.02% -0.006 %/ C at 20 C at 0 C Mean temperature coefficient from 20 C to 0 C Limit for meters of class 0.05 I n -0.01% -0.12% -0.006 %/ C I n 1-0.10% -0.24% -0.007 %/ C ±0.01 %/ C ±0.03 %/ C I max -0.10% -0.22% -0.006 %/ C 0.1 I n 0.03% -0.08% -0.006 %/ C 0.5 I n -0.05% -0.19% -0.007 %/ C ±0.02 %/ C ±0.05 %/ C inductive I max -0.02% -0.15% -0.007 %/ C at 0 C at -20 C Mean temperature coefficient from 0 C to -20 C Limit for meters of class 0.05 I n -0.12% -0.29% -0.009 %/ C I n 1-0.24% -0.40% -0.008 %/ C ±0.01 %/ C ±0.03 %/ C I max -0.22% -0.38% -0.008 %/ C 0.1 I n -0.08% -0.19% -0.006 %/ C 0.5 I n -0.19% -0.37% -0.009 %/ C ±0.02 %/ C ±0.05 %/ C inductive I max -0.15% -0.35% -0.010 %/ C Page 11 of 19

Voltage variation Voltage variation variation in Limit of variation in for meters of class 0.06% +10% 0.05 I n 0.06% 0.00% ±0.10% ±0.20% -10% 0.07% 0.01% -0.05% +10% -0.04% 0.01% ±0.10% ±0.20% +15% -0.02% 0.03% ±0.30% ±0.60% I n 1-10% -0.03% 0.02% ±0.10% ±0.20% -20% -0.04% 0.01% ±0.30% ±0.60% -50% -0.05% 0.00% +10/-100% +10/-100% -0.05% +10% I max -0.03% 0.02% ±0.10% ±0.20% -10% -0.04% 0.01% 0.06% +10% 0.1 I n 0.06% 0.00% ±0.20% ±0.40% -10% 0.08% 0.02% 0.00% +10% 0.01% 0.01% ±0.20% ±0.40% +15% 0.5 0.01% 0.01% ±0.30% ±0.60% I -10% n inductive 0.02% 0.02% ±0.20% ±0.40% -20% 0.03% 0.03% ±0.30% ±0.60% -50% 0.03% 0.03% +10/-100% +10/-100% 0.02% +10% I max 0.05% 0.03% ±0.20% ±0.40% -10% 0.04% 0.02% Frequency variation Frequency variation variation in Limit of variation in for meters of class 0.05% +2% 0.05 I n 0.07% 0.02% ±0.10% ±0.20% -2% 0.07% 0.02% -0.03% +2% I n 1-0.02% 0.01% ±0.10% ±0.20% -2% -0.04% -0.01% -0.05% +2% I max -0.04% 0.01% ±0.10% ±0.20% -2% -0.06% -0.01% 0.08% +2% 0.1 I n 0.06% -0.02% ±0.10% ±0.20% -2% 0.14% 0.06% 0.00% 0.5 +2% I n 0.02% 0.02% inductive ±0.10% ±0.20% -2% 0.00% 0.00% 0.05% +2% I max 0.06% 0.01% ±0.10% ±0.20% -2% 0.05% 0.00% Page 12 of 19

Reversed phase sequence Phase sequence variation in Limit of variation in for meters of class 0.04% 0.1 I n 1 Reversed 0.04% 0.00% ±0.05% ±0.10% Voltage unbalance Phase(s) interrupted variation in Limit of variation in for meters of class -0.05% L1-0.05% 0.00% L2-0.04% 0.01% L3 I n 1-0.04% 0.01% ±0.50% ±1.00% L1 and L2-0.02% 0.03% L2 and L3-0.03% 0.02% L3 and L1-0.05% 0.00% Note: Since the reference meter requires a voltage on L3 for accurate energy measurements, L1 or L2 voltage and were connected to L3 on the reference meter for the tests in which L3 is interrupted. Auxiliary voltage ±15% This test is not applicable since the is powered by an external power supply (PM1 module) which has a worst-case line regulation of ±0.50%, i.e., the output voltage of the external power supply does not vary by more than ±0.50% across its entire specified input voltage range. Harmonic components in the and voltage circuits Test condition With harmonic components 0.5 I max 1 variation in Limit of variation in for meters of class -0.02% -0.05% -0.03% ±0.40% ±0.50% Sub-harmonics in the a.c. circuit Test condition With subharmonics 0.5 I n 1 variation in Limit of variation in for meters of class -0.02% 0.31% 0.33% ±0.60% ±1.50% Page 13 of 19

Continuous magnetic induction of external origin Test condition variation in Limit of variation in for meters of class -0.05% Electromagnet applied to rear input -0.04% 0.01% terminals Electromagnet applied to display -0.04% 0.01% Electromagnet applied immediately above display -0.05% 0.00% Electromagnet applied immediately below display -0.05% 0.00% Electromagnet applied to front input terminals -0.04% 0.01% Electromagnet applied to top of module -0.04% 0.01% Electromagnet applied to rear output I n 1-0.05% 0.00% terminals of module ±2.00% ±2.00% Electromagnet applied to front output terminals of module -0.03% 0.02% Electromagnet applied to module output cable -0.05% 0.00% Electromagnet applied to left side of module -0.05% 0.00% Electromagnet applied to rear terminals of power supply module -0.05% 0.00% Electromagnet applied to right side of power supply module -0.04% 0.01% Electromagnet applied to front terminals of power supply module -0.05% 0.00% Magnetic induction of external origin 0.5 mt Test condition variation in Limit of variation in for meters of class -0.04% facing up, display parallel to loop -0.06% -0.02% facing up, display perpendicular to loop -0.04% 0.00% facing up, display diagonal to loop I n 1-0.06% -0.02% ±0.50% ±1.00% upright, display parallel to loop -0.04% 0.00% upright, display perpendicular to loop -0.05% -0.01% upright, display diagonal to loop -0.05% -0.01% Page 14 of 19

Electromagnetic RF fields See attached ITC test report for description of test parameters. Test condition (Frequency, antenna orientation) Page 15 of 19 variation in Limit of variation in for meters of class -0.04% 80 MHz, horizontal -0.02% 0.02% 100 MHz, horizontal -0.08% -0.04% 120 MHz, horizontal -0.01% 0.03% 140 MHz, horizontal -0.03% 0.01% 160 MHz, horizontal -0.08% -0.04% 180 MHz, horizontal -0.14% -0.10% 200 MHz, horizontal -0.15% -0.11% 220 MHz, horizontal -0.01% 0.03% 240 MHz, horizontal -0.06% -0.02% 260 MHz, horizontal -0.07% -0.03% 280 MHz, horizontal -0.06% -0.02% 300 MHz, horizontal -0.05% -0.01% 320 MHz, horizontal -0.05% -0.01% 340 MHz, horizontal 0.00% 0.04% 360 MHz, horizontal -0.10% -0.06% 380 MHz, horizontal -0.03% 0.01% 400 MHz, horizontal -0.03% 0.01% 450 MHz, horizontal -0.09% -0.05% 500 MHz, horizontal -0.03% 0.01% 550 MHz, horizontal -0.09% -0.05% 600 MHz, horizontal -0.09% -0.05% 650 MHz, horizontal -0.03% 0.01% 700 MHz, horizontal -0.03% 0.01% 750 MHz, horizontal -0.03% 0.01% 800 MHz, horizontal -0.02% 0.02% 850 MHz, horizontal -0.02% 0.02% 900 MHz, horizontal -0.02% 0.02% 950 MHz, horizontal -0.02% 0.02% I n 1 1000 MHz, horizontal -0.02% 0.02% ±1.00% ±2.00% 1100 MHz, horizontal 0.01% 0.05% 1200 MHz, horizontal -0.03% 0.01% 1300 MHz, horizontal -0.01% 0.03% 1400 MHz, horizontal -0.07% -0.03% 1500 MHz, horizontal 0.00% 0.04% 1600 MHz, horizontal -0.07% -0.03% 1700 MHz, horizontal -0.01% 0.03% 1800 MHz, horizontal 0.00% 0.04% 1900 MHz, horizontal -0.06% -0.02% 2000 MHz, horizontal -0.06% -0.02% 80 MHz, vertical 0.01% 0.05% 100 MHz, vertical -0.36% -0.32% 120 MHz, vertical -0.07% -0.03% 140 MHz, vertical -0.09% -0.05% 160 MHz, vertical -0.12% -0.08% 180 MHz, vertical -0.10% -0.06% 200 MHz, vertical -0.07% -0.03% 220 MHz, vertical -0.05% -0.01% 240 MHz, vertical -0.10% -0.06% 260 MHz, vertical -0.02% 0.02% 280 MHz, vertical -0.04% 0.00% 300 MHz, vertical -0.10% -0.06% 320 MHz, vertical -0.07% -0.03% 340 MHz, vertical -0.06% -0.02% 360 MHz, vertical -0.06% -0.02% 380 MHz, vertical -0.05% -0.01% 400 MHz, vertical -0.05% -0.01% 450 MHz, vertical -0.05% -0.01%

Test condition (Frequency, antenna orientation) variation in Limit of variation in for meters of class 500 MHz, vertical -0.05% -0.01% 550 MHz, vertical -0.04% 0.00% 600 MHz, vertical -0.04% 0.00% 650 MHz, vertical -0.04% 0.00% 700 MHz, vertical -0.04% 0.00% 750 MHz, vertical -0.04% 0.00% 800 MHz, vertical -0.04% 0.00% 850 MHz, vertical -0.04% 0.00% 900 MHz, vertical -0.04% 0.00% 950 MHz, vertical -0.04% 0.00% 1000 MHz, vertical I n 1-0.04% 0.00% ±1.00% ±2.00% 1100 MHz, vertical 0.01% 0.05% 1200 MHz, vertical -0.03% 0.01% 1300 MHz, vertical -0.01% 0.03% 1400 MHz, vertical -0.07% -0.03% 1500 MHz, vertical 0.00% 0.04% 1600 MHz, vertical -0.07% -0.03% 1700 MHz, vertical -0.01% 0.03% 1800 MHz, vertical 0.00% 0.04% 1900 MHz, vertical -0.06% -0.02% 2000 MHz, vertical -0.06% -0.02% Note: For all the tests in the table above, except for the reference measurement, the measurement duration was reduced to 30 seconds to reduce the overall duration of this set of tests. This increases the measurement uncertainty to a worst-case value of approximately 0.07%, which is well within the limit for these tests. Operation of accessories Per engineering review, this influence quantity is not applicable to the. Conducted disturbances, induced by radio-frequency fields See attached ITC test report for description of test parameters. Test condition Page 16 of 19 variation in Limit of variation in for meters of class -0.04% 150 khz, applied to conductors -0.07% -0.03% 200 khz, applied to conductors 0.01% 0.05% 250 khz, applied to conductors -0.03% 0.01% 300 khz, applied to conductors -0.01% 0.03% 350 khz, applied to conductors 0.00% 0.04% 400 khz, applied to conductors -0.05% -0.01% 450 khz, applied to conductors 0.02% 0.06% 500 khz, applied to conductors -0.04% 0.00% 600 khz, applied to conductors I n 1-0.02% 0.02% ±1.00% ±2.00% 700 khz, applied to conductors -0.07% -0.03% 800 khz, applied to conductors 0.00% 0.04% 900 khz, applied to conductors -0.05% -0.01% 1 MHz, applied to conductors -0.04% 0.00% 2 MHz, applied to conductors -0.03% 0.01% 3 MHz, applied to conductors -0.09% -0.05% 4 MHz, applied to conductors -0.01% 0.03% 5 MHz, applied to conductors -0.01% 0.03% 6 MHz, applied to conductors -0.07% -0.03%

Test condition variation in Limit of variation in for meters of class 7 MHz, applied to conductors 0.00% 0.04% 8 MHz, applied to conductors -0.07% -0.03% 9 MHz, applied to conductors -0.05% -0.01% 10 MHz, applied to conductors 0.07% 0.11% 20 MHz, applied to conductors 0.03% 0.07% 30 MHz, applied to conductors -0.03% 0.01% 40 MHz, applied to conductors -0.03% 0.01% 50 MHz, applied to conductors 0.06% 0.10% 60 MHz, applied to conductors -0.03% 0.01% 70 MHz, applied to conductors -0.11% -0.07% 80 MHz, applied to conductors 0.01% 0.05% 150 khz, applied to voltage conductors -0.05% -0.01% 200 khz, applied to voltage conductors -0.02% 0.02% 250 khz, applied to voltage conductors 0.03% 0.07% 300 khz, applied to voltage conductors -0.05% -0.01% 350 khz, applied to voltage conductors -0.08% -0.04% 400 khz, applied to voltage conductors -0.04% 0.00% 450 khz, applied to voltage conductors -0.09% -0.05% 500 khz, applied to voltage conductors -0.06% -0.02% 600 khz, applied to voltage conductors -0.04% 0.00% I n 1 ±1.00% ±2.00% 700 khz, applied to voltage conductors -0.02% 0.02% 800 khz, applied to voltage conductors 0.00% 0.04% 900 khz, applied to voltage conductors -0.01% 0.03% 1 MHz, applied to voltage conductors -0.01% 0.03% 2 MHz, applied to voltage conductors 0.00% 0.04% 3 MHz, applied to voltage conductors -0.06% -0.02% 4 MHz, applied to voltage conductors -0.07% -0.03% 5 MHz, applied to voltage conductors -0.03% 0.01% 6 MHz, applied to voltage conductors -0.05% -0.01% 7 MHz, applied to voltage conductors 0.00% 0.04% 8 MHz, applied to voltage conductors -0.02% 0.02% 9 MHz, applied to voltage conductors -0.03% 0.01% 10 MHz, applied to voltage conductors -0.03% 0.01% 20 MHz, applied to voltage conductors 0.01% 0.05% 30 MHz, applied to voltage conductors -0.08% -0.04% 40 MHz, applied to voltage conductors -0.02% 0.02% 50 MHz, applied to voltage conductors -0.01% 0.03% 60 MHz, applied to voltage conductors -0.07% -0.03% 70 MHz, applied to voltage conductors -0.07% -0.03% 80 MHz, applied to voltage conductors 0.03% 0.07% Note: For all the tests in the table above, except for the reference measurement, the measurement duration was reduced to 30 seconds to reduce the overall duration of this set of tests. This increases the measurement uncertainty to a worst-case value of approximately 0.07%, which is well within the limit for these tests. Fast transient burst Contact the manufacturer for further information regarding this influence quantity test. Damped oscillatory waves immunity Contact the manufacturer for further information regarding this influence quantity test. Page 17 of 19

8.3 Test of starting and no-load condition 8.3.1 Initial start-up of the meter The meter is functional within 5 s after the reference voltage is applied to the meter terminals. 8.3.2 Test of no-load condition The minimum test period Δt shall be Δt (900 10 6 )/(k m Un Imax) [min] for meters of class 0,2 S Δt (600 10 6 )/(k m Un Imax) [min] for meters of class 0,5 S where k is the number of pulses emitted by the output device of the meter per kilowatthour (imp/kwh) m is the number of measuring elements Un is the reference voltage in volts Imax is the maximum in amperes For this test, the Wh/pulse value of the was set to 0.1, resulting in a value of k equal to 10000. This results in a minimum test period of 22 minutes for meters of class 0,2 S, and 15 minutes for meters of class 0,5 S. Voltage Number of pulses produced by meter over minimum test period Δt, class 0,2 S Number of pulses produced by meter over minimum test period Δt, class 0,5 S Maximum number of pulses allowed 115% U n 0 0 1 8.3.3 Starting The meter starts and continues to register at 0.001 In and unity power, with balanced load. This test was applied with energy flowing in each direction, and was conducted over a period of greater than 30 minutes, with the Wh/pulse value of the set to 0.1. 8.4 Meter constant This requirement is not applicable since the meter does not carry a name-plate. Page 18 of 19

List of test equipment used Description Manufacturer Model number Serial number Calibration due date NIST trace path High-speed analog output, 16-bit, 8 channels National Instruments PCI-6733 0x134B48F N/A High-voltage amplifier Trek 2210 149 N/A High-voltage amplifier Trek 2210 160 N/A High-voltage amplifier Trek 2210 158 N/A Transconductance amplifier Fluke 5220A 5330005 N/A Transconductance amplifier Fluke 5220A 4610014 N/A Transconductance amplifier Fluke 5220A 4340119 N/A Programmable AC power source Chroma 61601 616010002652 N/A energy standard Radian Research RD-30 301182 06/05/2015 Radian Research Cert. #28257 Page 19 of 19

Test Data Summary issued under the responsibility of: ITC ENGINEERING SERVICES, INC. Report No.... : IEC 62052-11:2003, Electricity Metering Equipment General Requirements, Tests and Test Conditions Part 11: Metering Equipment Date of Issue... : May 6, 2015 Total Number of Pages... : 11 Testing Laboratory... : 20150427-01R Quality Monitor ITC Engineering Services, Inc. Address... : 9959 Calaveras Road, Box 543, Sunol, CA 94586 Applicant s Name... : Standards Lab Address... : 980 Atlantic Ave., Alameda, CA 94501 Contact... : Phone... : Mr. Matthew Muh 510-522-4400 x826 Fax... : 510-522-4455 Test Specification Standard... : IEC 62052-11:2003 Test Procedure... : Judgment... : Test Item Description... : Trade Mark... : Manufacturer... : Immunity Model/Type... : PQube 3 Input Voltage Rating... : (IEC 61000-4-3:2010, IEC 61000-4-4:2012 & IEC 61000-4-6:2013) Complies as Tested Quality Monitor Standards Lab 230V~, 50Hz ISO/IEC 17025:2005 Accredited Laboratory

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor TABLE OF CONTENTS TABLE OF CONTENTS... 2 1 DOCUMENTATION... 2 1.1 SUMMARY OF TESTS... 2 1.2 GENERAL TEST REMARKS: CUSTOM... 2 2 IMMUNITY TESTS... 3 2.1 RADIATED RF ELECTROMAGNETIC FIELDS PER IEC 61000-4-3:2010... 3 Test Specification... 3 Test Setup Photo... 5 2.2 ELECTRICAL FAST TRANSIENT PER EN 61000-4-4:2012... 6 Test Specification... 6 Test Setup Photo... 7 2.3 CONDUCTED IMMUNITY PER EN 61000-4-6:2013... 8 Test Specification:... 8 Test Setup Photo:... 10 3 APPENDIX... 11 3.1 TECHNICAL SPECIFICATIONS... 11 3.2 MODIFICATION LETTER... 11 1 DOCUMENTATION 1.1 SUMMARY OF TESTS ITC Engineering Services, Inc. as an independent testing laboratory, declares that the equipment specified above was tested to the requirements of : IMMUNITY REGULATIONS: IEC 62052-11:2003 (IEC 61000-4-3:2010, IEC 61000-4-4:2012 & IEC 61000-4-6:2013) 1.2 GENERAL TEST REMARKS: CUSTOM REVISION HISTORY Rev. # Date Prior Rpt. No. Rev. Rpt. No. Revision 1 6 May 2015 20150427-01 20150427-01R Inserted test setup photos. Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 2 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor 2 IMMUNITY TESTS 2.1 RADIATED RF ELECTROMAGNETIC FIELDS PER IEC 61000-4-3:2010 Date: 4/27/15 Client: Standards Lab Tester s Name: D.E. Waldbeser Name of Equipment (): PQube Model No: 3 Serial No.: P3001567/P3001592 Joblog: 20150427-01 Temperature/Humidity: 25/45 Test Voltage: 230 Vac, 50 Hz Equipment Description Manufacturer Model Name Serial Number Calibration Due Date RF Amplifier Amplifier Research 250A250 29034 N/A RF Amplifier IFI SMX200 L387-0407 N/A RF Amplifier OphirRF 5163F 1030 N/A Synthesized Sweeper Gigatronics 2550B 919003 12/1/16 Log Periodic Antenna Amplifier Research AT1100 10537 N/A DRG Horn Antenna A.H. Systems SAS-571 887 10/14/16 Isotropic Field Probe ETS LINDGREN HI-4455 00060849 10/15/16 TEST SPECIFICATION Frequency Range 80 MHz 2 GHz 1 GHz 2.7 GHz Field Strength 1 V/m 3 V/m 10 V/m V/m Distance Antenna 1 m 3 m Modulation AM 80 % 1 khz FM % khz Sine Wave Unmodulated Polarization of Antenna Horizontal Vertical Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 3 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 4 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor Test Setup Photo: RADIATED SUSCEPTIBILITY Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 5 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor 2.2 ELECTRICAL FAST TRANSIENT PER EN 61000-4-4:2012 Date: 4/29/15 Client: Standards Lab Tester s Name: D.E. Waldbeser Name of Equipment (): PQube Model No: 3 Serial No.: P3001567/P3001592 Joblog: 20150427-01 Temperature/Humidity: 20/40 Test Voltage: 230 Vac, 50 Hz Equipment Description Manufacturer Model Name Serial Number EFT Burst Tester Haefely PEFT.1 081 879-0 N/A Coupling Clamp Haefely-Trench IP4A 083 839-11 N/A TEST SPECIFICATION Calibration Due Date Pulse Ampl. - AC Port - source 0.5 kv 1.0 kv 2.0 kv 4.0 kv Pulse Ampl. - AC Port - 0.5 kv 1.0 kv 2.0 kv 4.0 kv measure Pulse Amplitude - Signal/Data 0.5 kv 1.0 kv 2.0 kv kv Burst Frequency 5 khz 100 khz khz Burst Duration 15 ms 0.75 ms ms Burst Period 300 ms ms Time of Coupling 60 seconds seconds Coupling Method Coupling Clamp Coupling./Decoupling. Network Polarity Positive Negative Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 6 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor Test Setup Photo: ELECTRICAL FAST TRANSIENT Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 7 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor 2.3 CONDUCTED IMMUNITY PER EN 61000-4-6:2013 Date: 4/29/15 Client: Standards Lab Tester s Name: D.E. Waldbeser Name of Equipment (): PQube Model No: 3 Serial No.: P3001567 & P3001592 Joblog: 20150427-01 Temperature/Humidity: 23/40 Test Voltage: 230 Vac, 50 Hz Model: Equipment Used: Serial No.: Calibration Due: Agilent 8648C RF Signal Generator 3847A05285 Verified Before Use Amplifier Research RF Amplifier 29034 Verified Before Use 250A250 Tektronix Oscilloscope B020599 1/9/16 TDS7104 Fischer Calibration Fixture 464 Verified Before Use FCC-BCICF-1 A.H Systems ICP-521 Injection Current Probe 191 Verified Before Use Clock frequency & harmonics: TEST SPECIFICATION: Frequency Range 150 khz 80 MHz 26 MHz 80 MHz Field Strength 1 Vrms 3 Vrms 10 Vrms _ Vrms Modulation AM 80 % 1 khz FM khz Rate Sine Wave Unmodulated Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 8 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor HP 8648C AR250A250 20dB before amp driving ICP-521 Frequency khz Level dbm Frequency MHz Level dbm Frequency MHz Level dbm U o = 10 V rms * 2 2 = 28.3 V p-p U mr = U o /2 = 28.3 V p-p /2 = 14.1 V p-p U mr = U o /2 = 10 V rms /2 = 5 V rms 150 3 1.0 0 10-2 200 2 2.0-1 20-1 250 2 3.0-1 30-1 300 2 4.0-2 40-3 350 1 5.0-2 50-1 400 1 6.0-2 60-3 450 1 7.0-2 70-2 500 1 8.0-2 80-1 600 1 9.0-2 700 0 800 0 900 0 Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 9 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor Test Setup Photo: CONDUCTED IMMUNITY Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 10 of 11 Product: Quality Monitor Model: PQube 3

Applicant: Standards Lab Report No. 20150427-01R Quality Monitor 3 APPENDIX 3.1 TECHNICAL SPECIFICATIONS Manufacturer: Standards Lab General Description: The, PQube 3, is a High Speed Analyzer Description: Quality Monitor Model: PQube 3 Rated Voltage: 230V~, 50Hz 3.2 Modification Letter To Whom It May Concern: Standards was tested to: IEC 62052-11:2003 Immunity Test Methods: IEC 61000-4-3:2010 IEC 61000-4-4:2012 IEC 61000-4-6:2013 For further information, please contact the manufacturer at: Mr. Matthew Muh POWER STANDARDS LAB 980 Atlantic Ave. Alameda, CA 94501 Phone: 510-522-4400 x826 Fax: 510-522-4455 Email: matthew@powerstandards.com Prepared By: ITC Engineering Services, Inc. 9959 Calaveras Road, PO Box 543 Sunol, California 94586-0543 Tel: +1(925) 862-2944 Fax: +1(925) 862-9013 Email: itcemc@itcemc.com Web: www.itcemc.com Page 11 of 11 Product: Quality Monitor Model: PQube 3