ALIGNMENT SENSITIVITY AND CORRECTION METHODS FOR MILLIMETER- WAVE SPHERICAL NEAR-FIELD MEASUREMENTS

Similar documents
SPHERICAL NEAR-FIELD SELF-COMPARISON MEASUREMENTS

REFLECTION SUPPRESSION IN LARGE SPHERICAL NEAR-FIELD RANGE

IMPROVING AND EXTENDING THE MARS TECHNIQUE TO REDUCE SCATTERING ERRORS

MISSION TO MARS - IN SEARCH OF ANTENNA PATTERN CRATERS

Accurate Planar Near-Field Results Without Full Anechoic Chamber

High Accuracy Spherical Near-Field Measurements On a Stationary Antenna

A COMPOSITE NEAR-FIELD SCANNING ANTENNA RANGE FOR MILLIMETER-WAVE BANDS

A CYLINDRICAL NEAR-FIELD VS. SPHERICAL NEAR-FIELD ANTENNA TEST COMPARISON

PROBE CORRECTION EFFECTS ON PLANAR, CYLINDRICAL AND SPHERICAL NEAR-FIELD MEASUREMENTS

Sub-millimeter Wave Planar Near-field Antenna Testing

Millimetre Spherical Wave Antenna Pattern Measurements at NPL. Philip Miller May 2009

RAYTHEON 23 x 22 50GHZ PULSE SYSTEM

33 BY 16 NEAR-FIELD MEASUREMENT SYSTEM

PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES

Accuracy Estimation of Microwave Holography from Planar Near-Field Measurements

Near-Field Antenna Measurements using a Lithium Niobate Photonic Probe

Antenna Measurement Uncertainty Method for Measurements in Compact Antenna Test Ranges

Structural Correction of a Spherical Near-Field Scanner for mm-wave Applications

IMPLEMENTATION OF BACK PROJECTION ON A SPHERICAL NEAR- FIELD RANGE

Upgraded Planar Near-Field Test Range For Large Space Flight Reflector Antennas Testing from L to Ku-Band

ANECHOIC CHAMBER EVALUATION

HIGH ACCURACY CROSS-POLARIZATION MEASUREMENTS USING A SINGLE REFLECTOR COMPACT RANGE

Estimating Measurement Uncertainties in Compact Range Antenna Measurements

A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION

APPLICATIONS OF PORTABLE NEAR-FIELD ANTENNA MEASUREMENT SYSTEMS

ANECHOIC CHAMBER DIAGNOSTIC IMAGING

SPHERICAL NEAR-FIELD MEASUREMENTS AT UHF FREQUENCIES WITH COMPLETE UNCERTAINTY ANALYSIS

A DUAL-PORTED PROBE FOR PLANAR NEAR-FIELD MEASUREMENTS

ADVANTAGES AND DISADVANTAGES OF VARIOUS HEMISPHERICAL SCANNING TECHNIQUES

HOW TO CHOOSE AN ANTENNA RANGE CONFIGURATION

Further Refining and Validation of RF Absorber Approximation Equations for Anechoic Chamber Predictions

METHODS TO ESTIMATE AND REDUCE LEAKAGE BIAS ERRORS IN PLANAR NEAR-FIELD ANTENNA MEASUREMENTS

PRACTICAL GAIN MEASUREMENTS

MEASUREMENT OF THE EARTH-OBSERVER-1 SATELLITE X-BAND PHASED ARRAY

An introduction to Mobile Station Over-the-Air measurements

The Importance of Polarization Purity Author: Lars J Foged, Scientific Director at MVG (Microwave Vision Group)

GAIN COMPARISON MEASUREMENTS IN SPHERICAL NEAR-FIELD SCANNING

Software. Equipment. Add-ons. Accessories. Services

WIESON TECHNOLOGIES CO., LTD.

Millimeter Spherical µ-lab System from Orbit/FR

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION

AN AUTOMATED CYLINDRICAL NEAR-FIELD MEASUREMENT AND ANALYSIS SYSTEM FOR RADOME CHARACTERIZATION

Characterization of a Photonics E-Field Sensor as a Near-Field Probe

Implementation of a VHF Spherical Near-Field Measurement Facility at CNES

NUMERICAL OPTIMIZATION OF A SATELLITE SHF NULLING MULTIPLE BEAM ANTENNA

Using measured fields as field sources in computational electromagnetic (CEM) solvers

System configurations. Main features. I TScan SOLUTION FOR

> StarLab. Multi-purpose Antenna Measurement Multi-protocol Antenna Development Linear Array Antenna Measurement OTA Testing

Keywords: cylindrical near-field acquisition, mechanical and electrical errors, uncertainty, directivity.

The CDT Ultra Wide-Band Anechoic Chamber. Félix Tercero, José Manuel Serna, Tim Finn, J.A.López Fernández INFORME TÉCNICO IT - OAN

Uncertainty Considerations In Spherical Near-field Antenna Measurements

Comparison of antenna measurement results in disturbed environment using a VHF spherical near field system

Main features. System configurations. I Compact Range SOLUTION FOR

A TURNKEY NEAR-FIELD MEASUREMENT SYSTEM FOR PULSE MODE APPLICATIONS

Conventional measurement systems

T- DualScan. StarLab

Non-Ideal Quiet Zone Effects on Compact Range Measurements

Antenna and RCS Measurement Configurations Using Agilent s New PNA Network Analyzers

SAGE Millimeter, Inc.

The CReSIS Anechoic Chamber is located at: The University of Kansas. M2SEC building W 15 th St. Lawrence, KS

TRADITIONAL ANTENNA MEASUREMENTS AND CTIA OTA MEASUREMENTS MERGING THE TECHNOLOGIES

ESTIMATING THE UNCERTAINTIES DUE TO POSITION ERRORS IN SPHERICAL NEAR-FIELD MEASUREMENTS

60 GHz antenna measurement setup using a VNA without external frequency conversion

Agilent Antenna and RCS Measurement Configurations Using PNA Microwave Network Analyzers. White Paper

Millimeter Wave Measurement System

Vehicle Level Antenna Pattern & ADAS Measurement

ON THE DEVELOPMENT OF GHZ ANTENNAS FOR TOWED DECOYS AND SUITABILITY THEREOF FOR FAR-FIELD AND NEAR-FIELD MEASUREMENTS

High Performance Dual Polarized Near-Field Probe at V-Band Provides Increased Performances for Millimeter Wave Spherical Near-Field Measurements

Antenna Measurement Theory

Spherical Scanning Measurement Challenge for Future Millimeter Wave Applications

Part No. ETH-MMW-1000 (version 1A) Millimeter Measurement System Frequency Range: 18 GHz 75 GHz

A SIMPLE ANALYSIS OF NEAR-FIELD BORESIGHT ERROR REQUIREMENTS

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

A LARGE SPHERICAL NEAR-FIELD ARCH SCANNER FOR CHARACTERIZING LOW-FREQUENCY PHASED ARRAYS

Design, Trade-Off and Advantages of a Reconfigurable Dual Reflector for Ku Band Applications

HScan. Horizontal Scanner

EHF Rotman Lens Fed Linear Array Multibeam Planar Near-Field Range Measurements CST 5 th NORTH AMERICAN USERS FORUM 4th FEBRUARY 2008 SANTA CLARA, CA

A Method for Gain over Temperature Measurements Using Two Hot Noise Sources

Advanced Waveform Generator For Integrated Phased Array Testing

A Reconfigurable Antenna Based on an Electronically Tunable Reflectarray

Dual Polarized Near Field Probe Based on OMJ in Waveguide Technology Achieving More Than Octave Bandwidth

Introduction to Measurement Techniques

System configurations. Main features I SG 64 SOLUTION FOR

Exercise 1-3. Radar Antennas EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION OF FUNDAMENTALS. Antenna types

Radiation Pattern of Waveguide Antenna Arrays on Spherical Surface - Experimental Results

DTU-ESA millimeter-wave validation standard antenna requirements and design

Uncertainty Analysis of Spherical Near Field Antenna Measurement System at VHF

PRIME FOCUS FEEDS FOR THE COMPACT RANGE

Dr. John S. Seybold. November 9, IEEE Melbourne COM/SP AP/MTT Chapters

SPHERICAL NEAR-FIELD ANTENNA MEASUREMENTS: A REVIEW OF CORRECTION TECHNIQUES

Truncation Error Mitigation in Free-Space Automotive Partial Spherical Near Field Measurements

MAKING TRANSIENT ANTENNA MEASUREMENTS

CHARACTERIZATION OF PHASE SHIFTERS ON A KU-BAND PHASED ARRAY ANTENNA ESA/ESTEC, NOORDWIJK, THE NETHERLANDS 3-5 OCTOBER 2012

A NEW WIDEBAND DUAL LINEAR FEED FOR PRIME FOCUS COMPACT RANGES

Chapter 5. Array of Star Spirals

Keysight Technologies PNA Receiver Reduces Antenna/RCS Measurement Test Times

Reflector antennas and their feeds

Full-Wave Analysis of Planar Reflectarrays with Spherical Phase Distribution for 2-D Beam-Scanning using FEKO Electromagnetic Software

18th International Symposium on Space Terahertz Technology. Measurement of a high-gain antenna at 650 GHz in a hologram-based CATR

Transcription:

ALIGNMENT SENSITIVITY AND CORRECTION METHODS FOR MILLIMETER- WAVE SPHERICAL NEAR-FIELD MEASUREMENTS Greg Hindman, Allen Newell Nearfield Systems Inc. 1973 Magellan Drive Torrance, CA 952, USA Luciano Dicecca Teleinformatica e Sistemi s.r.l. (a Space Engineering Company) Via di Tor Tre Teste 229, I-155 Roma, Italy Jean Christophe Angevain European Space Agency/ESTEC Keplerlaan 1 - P.O. Box 299-22 AG Noordwijk ZH - The Netherlands ABSTRACT Millimeter-wave measurements on spherical nearfield scanning systems present a number of technical challenges to be overcome to guarantee accurate measurements are achieved. This paper will focus on the affect of mechanical alignment errors of the spherical rotator system on the antenna s measured performance. Methods of precision alignment will be reviewed. Sensitivity to induced mechanical alignment errors and their affect on various antenna parameters will be shown and discussed. Correction methods for residual alignment errors will also be described. The study includes 38 and 48 GHz data on the Alphasat EM model offset reflector antenna measured by TeS in Tito, Italy on a NSI-7S-6 Spherical Nearfield system, as well as a 4 GHz waveguide array antenna measured by NSI on a similar NSI-7S-6 Spherical Nearfield System at its factory in Torrance, CA, USA. Keywords: near-field, spherical, alignment 1. Introduction The described alignment sensitivity and correction method have been carried out in the NSI Spherical Near Field in the TeS - Teleinformatica e Sistemi plant located in Tito (Pz), South Italy. The TeS is a company belonging to Space Engineering Group. The AUT is the ALPHASAT EM antenna operating in the Q and V bands. In this frame, we have carried out the RF tests to tune the alignment of the NSI-7S-6 Spherical Near-Field system. The EM antenna is a single parabolic off-set reflector shown in Figure 1, during the integration, Figure 1 QVCA EM integration and in Figure 4 installed in the SNF. This antenna is representative of the complete PFM antenna farm shown in Figure 2. The antenna system has been designed in the frame of the ESA/ASI ALPHASAT/INMARSAT I-XL program. The TDP#5 (Technology Demonstration Payload 5) part of this program, includes the Q/V -band Communications Antenna (QVCA) and the Q and Ka propagation experiment. The project finality is to assess the feasibility of these bands for future commercial applications. Space Engineering S.p.A is responsible for the TDP#5 of the complete activities flow from the design to the delivery of the qualified space hardware.

2. Near-field Test Range The detailed description of the design and test activities on this antenna farm is reported in [1] The test range is a combination near-field / far-field system with a NSI-7S-6 spherical near-field scanning system installed in a 12 m x 7 m x 6.5 m rectangular anechoic chamber provided by Siepel. Figure 4 shows the Alphasat QVCA EM antenna installed on the NSI-7S-6 positioner in the chamber. The system includes a probe tower in close proximity that is used for near-field measurements, and a far-field probe tower at a distance of about 7 m away used for far-field measurements as shown in Figure 5 The system uses an Agilent PNA, combined with NSI s 5 GHz Distributed Frequency Converter and 5 GHz mixers to provide excellent signal sensitivity at the required frequencies. Figure 6 shows the scanner and RF subsystem configuration. Figure 2- QVCA PFM sketch The QVCA PFM make use of three off-set reflector antennas installed on the same base-plate to illuminate three earth stations in Europe (Figure 3) 8 7.5 7 IT2 EU1 Figure 4 QVCA EM in the Tito plant NSI SNF V [deg] 6.5 IT1 6 5.5 5-3.5-1.5-1 -.5 U [deg] Figure 3 QVCA PFM coverage The high alignment accuracy requirement comes from the required RF antenna link performances. Figure 5 NSI-7S-6 Spherical Near-field / Far-field

between these two geometries are instructive in evaluating the range alignment and reflection performance, and combining the results from both datasets in what we call a redundant dataset can be used to improve range performance. Further information on this technique is described in [6] Figure 6 System Block Diagram 3. Alignment Issues The system was aligned by NSI during installation, using the 5-axis laser alignment system described in [2]. This alignment is done prior to the antenna and probe being installed. NSI has also developed an RF alignment technique that can be done with the antennas installed and is useful to check and optimize the alignment with the weight of those devices included. Some studies of alignment sensitivity are shown in [3] and [4]. The 5-axis laser alignment technique can achieve system alignment to better than about.5 and 1 mm for all key alignment parameters, and the RF alignment technique is used to refine the pointing and intersection errors further. For the Alphasat requirement, at such a high frequency, we have recently performed additional studies of sensitivity of the alignment on the boresight measurements of high frequency antennas. The prior sensitivity studies in [3] primarily focused on sidelobe and directivity errors. In the NSI-7S-6 SNF system with 4 GHz waveguide array antenna, we conducted an alignment perturbation study, where we misaligned the theta-zero error (angle from the phi rotation axis to the probe) in.2 increments up to.12 and observed the resulting far-field alignment error. The NSI software allows measuring antenna performance on spherical near-field systems with two different geometries, that we typically designate 18phi and 36phi (Figure 7). In one case the Antenna Under Test (AUT) is rotated thru 36 about its axis and the theta stage is only rotated on one side -18,and in the other case, 18phi case, the AUT is only rotated 18 in phi, and the theta stage is rotated over ±18. Comparison Figure 7 Redundant data set through full rotation of theta and phi rotators, versus the two full spheres that can be derived for the 36 phi or 18 phi configurations In the following figures, we show the alignment sensitivity of the 4 GHz WG array to the theta-zero misalignment induced as described above. Pointing error (deg).1.8.6.4.2. -.2 -.4 -.6 -.8 -.1 Azimuth Pointing Error vs Theta Error..2.4.6.8.1.12 Theta error (deg) redundant 18phi 36phi Figure 8 WR28 WG Array Azimuth beam pointing error vs Theta-zero error for different SNF measurement geometries

Pointing error (deg) Elevation Pointing Error vs Theta Error.2. -.2 -.4 -.6 -.8 -.1 -.12 -.14 -.16..2.4.6.8.1.12 Theta error (deg) redundant 18phi 36phi 4. Alphasat Near-field Measurements Before starting the test activity all the required SNF measurement parameters have been defined. The Maximum Radial Extent (MRE) is.36 m as shown in Figure 11. The angular acquisition step size for this MRE at the test frequency of 48.4 GHz for the Alphasat QVCA EM reflector is.49. The near-field acquisition angular sector is shown in Figure 12, with the truncation of data beyond ±25 having been determined to have a negligible affect on system parameters of interest. Figure 9 WR28 WG Array Elevation beam pointing error vs Theta-zero error for different SNF measurement geometries Note that two different vertical scales are used in the figures. The azimuth beam pointing sensitivity to the theta-zero errors are small about.8 worst case for the 36phi geometry,.4 for the 18phi geometry, and only.2 for the redundant test. The elevation beam pointing is seen to be much more sensitive to the 18phi geometry. This is because the AUT is only rotated 18 in phi in this measurement geometry, which can magnify this particular error, whereas the 36phi and redundant measurements rotate the AUT the full 36 in phi. The elevation error with the 18phi geometry is almost directly proportional to the theta-zero error induced, however the 36phi and redundant tests show only a negligible beam pointing error of less than.2. So the conclusion from these measurements is to use the redundant measurement technique for best performance or the 36phi geometry if the double test time of the redundant technique is undesirable. Similar tests were conducted on the Alphasat QVCA EM and we saw very similar results for 38 GHz and 48 GHz frequencies (see Figure 1). Again, the use of the redundant data measurement scheme is seen to help to minimize sensitivity to alignment errors..2 Alphasat QVCA EM - Elevation Pointing Error vs Theta Error Relative power (db) -5-1 -15 Figure 11- QVCA EM MRE V band Near Field = scan acquisition. -.2 5 Pointing error (deg) -.4 -.6 -.8 -.1 redundant -= 38 GHz 18phi - 38 GHz 36ph - 38 GHz redundant - 48 GHz 18phi - 48 GHz 36phi - 48 GHz -3 5-15 -1-5 5 1 15 2 25 Theta (deg) -.12 -.14 -.16..1.2.3.4.5.6.7.8.9.1 Theta error (deg) Figure 12- QVCA EM scan window (including practically all the antenna energy) Figure 1 Alphasat QVCA EM Elevation beam pointing error vs Theta-zero error for different SNF measurement geometries

To check the positioner alignment, the RF alignment test (classic flip test) has been performed making use of a dedicated NSI script showing the azimuth misalignment and the intersection error. Result is shown in Figure 13. Relative amplitude db -4-6 -8-1 -12-14 -16-18 2 4 6 8-3 -32-34 -36-38 -4 H plane 48 GHz -1.9-1.8-1.7-1.6-1.5-1.4-1.3-1.2-1.1-1 -.9 -.8 -.7 -.6 -.5 -.4 -.3 -.2 -.1.1.2.3.4.5.6.7.8.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 Theta deg Co H plane measured Co H plane computed Figure 13 QVCA flip test In Figure 14 and in Figure 15 are shown the measured radiation patterns (after the alignment activity) superimposed to the computed radiation patterns E plane 48 GHz Figure 15- QVCA H plane measured and computed patterns From these last 2 figures appear clearly that excellent alignment and measurement accuracy have been achieved. The E field cut is almost perfect while in the H plane appears more a pattern distortion starting 1 db down than a beam misalignment. The beam alignment requirement was.3 corresponding to the allowable losses of.3 db as shown in Figure 16. Relative amplitude db -4-6 -8-1 -12-14 -16-18 2 4 6 8-3 -32-34 -36-38 -4-1.9-1.8-1.7-1.6-1.5-1.4-1.3-1.2-1.1-1 -.9 -.8 -.7 -.6 -.5 -.4 -.3 -.2 -.1.1.2.3.4.5.6.7.8.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 Theta deg Co E plane measured Cx E plane computed Co E plane computed Cx E plane measured Figure 14- QVCA E plane measured and computed patterns Figure 16 QVCA link losses Vs. beam misalignment

5.. Summary This paper has briefly described some of the challenges to achieving high accuracy spherical near-field measurements on millimeter wave antennas. Results of some alignment perturbation studies on millimeter wave antennas at two different spherical near-field ranges have been shown. The use of the redundant spherical measurement geometry technique has been shown to reduce sensitivity to alignment errors. The alignment methods have proved useful to the success of the ALPHASAT EM antenna measurement campaign conducted by TeS in Q and V bands. 6. REFERENCES [1] Gabellini P., D Agristina L., Dicecca L., Di Lanzo D., Gatti N., Falzini S., Codispoti G., Angevain J.C, "The Electrical Design and Verification of the Alphasat TDP#5 Antenna Farm", 32nd ESA Antenna Workshop on Antennas for Space Applications, 5-8 October 21 [2] Demas, J.N., "Low Cost and High Accuracy Alignment Methods for Cylindrical and Spherical Nearfield Measurement Systems ", AMTA 27th Annual Meeting & Symposium, Newport, RI, Oct. 25 [3] Newell, A. C., Hindman, G., "The alignment of a spherical near-field rotator using electrical measurements" In the proceedings of the 19th annual AMTA Meeting and Symposium, Boston, MA, 1997. [4] Newell, A. C., Hindman, G., "Quantifying the effect of position errors in spherical near-field measurements", In the proceedings of the 2th annual AMTA Meeting and Symposium, pp 145-149, Montreal, Canada, 1998. [5] Newell, A.C., "The effect of measurement geometry on alignment errors in spherical near-field measurements", AMTA 21st Annual Meeting & Symposium, Monterey, California, Oct. 1999. [6] Hindman, G., Newell, A.C., "Spherical Near-Field Self-Comparison Measurements", AMTA 26th Annual Meeting & Symposium, Atlanta, GA, Oct. 24. 7. ACKNOWLEDGMENTS The authors gratefully acknowledge Gianfranco Sordetti for his precious help during the test activity and Luis Rolo from the Antenna and Sub-Millimeter Wave Section of ESA for his fruitful suggestions regarding the antenna testing.