MDC VAC Input Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Similar documents
MBC Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA

MDC V, 2A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

DPFHP451 HIGH PERFORMANCE BILEVEL STEP MOTOR / MANUAL PRESET INDEXER DRIVER PACK

Section 2: Functions... 7 PI Tuning... 8

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

MBC10P31 Series. Programmable Pulse Generator. User s Guide. 910 East Orangefair Lane, Anaheim, CA

DSB810A Digital DC Servo Driver Manual V1.0

Copyright 2014 by Minarik Drives

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

SSR-150xxx-40VL-12P-xC-xxxCS

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

Silencer Series Brushless Controllers

EDE1204 Bi-Polar Stepper Motor IC

SRVODRV REV7 INSTALLATION NOTES

Digital Lighting Systems, Inc.

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

DMX-K-DRV-23 Integrated Step Motor Driver & Basic Controller

LS7362 BRUSHLESS DC MOTOR COMMUTATOR / CONTROLLER

7I25 H-BRIDGE MANUAL

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

DMX-K-DRV-17 Integrated Step Motor Driver & Basic Controller

DynaDrive INFORMATION MANUAL SDFP(S)

C5000 & C5000NF PULSE INITIATOR. Introduction

USER S MANUAL PROCESS CONTROL MODULE PCM3

Logosol Intelligent Hall-Servo Drive LS-173U Doc # / Rev. C, 02/12/2008

Installation Tech Note Dallas, Texas

Analog Servo Drive 100A40

PKG-341-MLA-CBL System Diagram and Specifications

Analog Servo Drive 30A8

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Independent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

BCM Array TM BC384R120T030VM-00

Analog Servo Drive 20A20

Analog Servo Drive 30A20AC

R208 Microstepping Driver. User Manual Version 1.3. Lin Engineering Vineyard Blvd, Morgan Hill, CA 95037

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

DA4303. User Manual DA Q Linear Servo 03 A

INSTRUCTION MANUAL TIMER -X UNIVERSAL TIMER

SSR VL-12P-xC-NCS

PKG-232-MBC12-PS-CBL System Diagram and Specifications

µservo drive user s guide

Servo Amplifier PMA 90 / 180

301 & 601 Mic/Line Mixers Operation Manual

Instruction Manual Model M Switch, DPDT, Manual Select

ADVANCED MICRO CONTROLS INC. Manual #: 940-0D043

Analog Servo Drive 30A8

EA4709 / EA4718. User Manual EA4709 / EA Q PWM Servo 09 / 18 A

BMC 6C & 7D HARDWARE INSTALLATION MANUAL. MCG Inc. BMC 6C & 7D Hardware Installation Manual ZN2UDB6799-4

Protected against over temperature and over current Continuous current up to 3 A

AxCent Servo Drive A25A100

DeviceCraft Revision #1 11/29/2010

AxCent Servo Drive A50A100

SCA-SS User Manual SCA-SS Q PWM Servo 06 A

SixPac Series of SCR AC Controller and DC Converters

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

PKG-171-MBC25-PS-CBL System Diagram and Specifications

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Analog Servo Drive. Continuous Current. Features

IAP200T120 SixPac 200A / 1200V 3-Phase Bridge IGBT Inverter

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

Amplified High Speed Photodetectors

DigiSpeed DC-03. Isolated Control Voltage Generator User s Guide. PCB: DC-03 V3.0 Firmware: Ver: 3.0 Mach3: Ver: 1.84

BC145 SIGNAL ISOLATOR BOARD

AMP-13 OPERATOR S MANUAL

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

SC-FI Series Frequency to Current Signal Conditioner

Glass Electrode Meter

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

Precision Frequency To Voltage Converter Card

User's Manual PDO 2035

Integrated Easy Servo

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Preliminary Data Sheet!

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

G201X STEP MOTOR DRIVE REV 5: SEPTEMBER 13, 2010

Logosol AC/DC Servo Amplifier LS-58P Doc # / Rev D, 07/17/2008

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Data Acquisition Modules/ Distributed IO Modules

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

SS421 Series. Solid State Hall-effect Sensors Adjustable Hall-Effect Under-speed Detectors

ies-2309 Integrated Easy Servo

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

TRANSDUCER IN-LINE AMPLIFIER

INSTRUCTION MANUAL. C1701 Relay Kit. December Copyright 2007 Campbell Scientific (Canada)Corp.

Transcription:

MDC200-048051 110VAC Input Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

MDC200-048051 Driver Features Maximum Current Limit Setting from 1-5Amps (peak) up to 100W Power Output Internal or External Potentiometer Speed Control 48VDC Motor Voltage Bus 2-Quadrant Operation Sensor Feedback Constant Velocity Mode Short Circuit Protection Requires 85-135 VAC Power Input Speed Output Fault Output Brake, Disable and Direction Inputs Selectable Ramp Up/Down Optically Isolated Inputs and Outputs Compact Size ( 6.25 x 4.35 x 1.93 ) Dual Mounting Option Detachable, Screw type Terminal Blocks General The MDC200-048051 driver is a velocity control driver designed to drive DC Brushless Motors from a supply of 120 VAC. With a motor bus voltage of 48V, maximum phase current of 5 A (peak) and power output of 100 W, this driver eliminates the need for an external power supply. Using hall sensor feedback, a constant velocity mode can be selected. The driver is protected against over current (cycle-by-cycle or latched), hall sensor error and under voltage. When an error occurs, a fault light is turned on to notify the user. Included on the driver is an internal potentiometer to control the maximum phase current allowed into the motor and an internal potentiometer to control the speed of the motor. An optional external potentiometer (10K) can be used to control the speed as well. The direction of the motor can be preset by the direction control input. Other inputs to the drive include a run/stop and a motor freewheel input. When using the run/stop input, there are three ramp up/down profiles from standstill to select from. The run/stop input overrides all other inputs into the driver. Pin s The inputs on the MDC200-048051 are optically isolated with the anode (+) and cathode (-) both brought out to the user. With no current going through the Direction, Freewheel, and Run/Stop opto-diodes, the input is considered high. To enable the motor to Run, current must go through the Run/Stop input optodiode. To Freewheel (remove energy from the motor) the motor, current must go through the Freewheel input opto-diode. To enable the input a minimum of 1.0 ma needs to be sourced or sinked through the optodiode. This is done simply by placing a voltage of +5 to +7 VDC across the two inputs of the opto-diode. If sourcing current into the inputs, then all three cathodes (-) should be tied together and grounded. If sinking current, then all three anodes (+) should be tied together to the +voltage. The PG Out and Fault output on the MDC200-048051 are an opto-decoupled open collector output. When normal operation occurs, this output will conduct current into the emitter. Care must be taken not to pass more than 50mA through this transistor.

Optically Isolated Inputs and Output The following inputs and output to the MDC200-048051 are Optically Isolated. I tem Pin # PG Out 1 & 2 Direction 3 & 4 Freewheel 5 & 6 Run Stop 7 & 8 Fault Out 9 & 10 To enable an input, apply a DC voltage source of +5VDC to +7VDC across the inputs. The Anodes (+) are pins 3, 5, and 7 and the Cathodes (-) are pins 4, 6, and 8. Absolute Maximum Ratings Output Current Rating: Adjustable 1.0-5.0 amperes per phase maximum operating peak current. (0.5-2.5 amperes per phase maximum operating continuous current) Power Requirements: (TB4, Pins 1 and 2) 85VAC (min) - 135VAC (max) Operating Temperature: Heat Sink: 0-70 C Sensor Power Output: 6.25V @30mA maximum. Typical current draw from hall sensors is 20mA. All three Sensor inputs are pulled up through 20K ohm resistors. The external speed control potentiometer must be 10K Ohms. Open Loop/ Closed Loop (Constant Velocity Mode) The driver can either be set for Open Loop or Closed Loop operation. Open Loop operation is used for applications where the speed of the motor needs to change according to the load. Closed Loop operation is used for applications where speed regulation is needed. Under closed loop operation, the speed is regualted despite changes to the load and the power supply voltage. To operate Open Loop, the O/C LOOP switch (SW1 - pos1) must be in the on position. To operate Closed Loop, the O/C LOOP switch must be in the off position and the CL ADJ potentiometer (R3) and CL ADJ dip switches (SW1 - pos2-4) must be set to optimize the driver for each application. The Closed Loop adjustments are needed for faster and slower motor operation, within the restrictions of the motor rated speed. The adjustments provide a direct duty cycle to the driver with respect to the required motor speed. The following tables show Closed Loop potentiometer and dip switch settings for each motor. These adjustments will set the maximum setting of the internal/external speed potentiometer to the motors maximum running speed. If operation at slower speeds is needed for the application, CL POT can be adjusted toward 100% until desired motor speed is achieved. The motor speed can be monitored by measuring the pulse rate of PG OUT (TB2 - pin 1 & 2)

4-pole motors Motor CL1 CL2 CL3 BLWR110S-15V-8000 BLWR111S-24V-10000 BLWR112S-24V-3700 BLWR231D-36V-4000 BLWR232D-36V-4000 BLWR233D-36V-4000 BLWR234D-36V-4000 BLWR235D-36V-4000 BLWR232S-24V-1350 BLWS231D-36V-4000 BLWS231S-36V-4000 BLWS232D-36V-4000 BLWS232S-36V-4000 BLWS233S-36V-4000 BLWS234D-36V-4000 BLWS234S-36V-4000 BLWS235S-36V-4000 CL POT MAX SPD (RPM) MIN SPD (RPM) O n 80% 8000 500 O n 50% 10050 825 O n 100% 3735 450 O ff 0% 1600 200 8-pole motors Motor BLY171S-17V-8000 BLY172S-17V-9500 BLY171S-24V-4000 BLY172D-24V-4000 BLY172S-24V-4000 BLY173D-24V-4000 BLY174D-24V-4000 BLY174S-24V-4000 BLY341D-48V-3200 BLY341S-48V-3200 BLY342D-24V-3000 BLY342D-30V-3000 BLY342S-30V-3000 BLY342D-48V-3200 BLY342S-48V-3200 BLY343D-48V-3200 BLY343S-48V-3200 BLY343S-30V-3000 BLY344D-48V-3200 BLY344S-48V-3200 BLZ362S-36V-3500 BLZ362S-160V-3500 BLZ482S-160V-3500 BLZ242S-24V-3500 CL1 CL2 CL3 CL POT MAX SPD (RPM) MIN SPD (RPM) O n 0% 7500 500 O n 0% 9000 500 O n 80% 4000 O n 80% 4000 O n 80% 4000 O n 80% 4000 O n 40% 3200 O n 40% 3000 O n 40% 3000 O n 30% 3200 O n 30% 3200 O n 40% 3000 O n 30% 3200 O n 10% 3500 330 O n 10% 3500 330 O n 10% 3500 330 O n 10% 3500 330

Commutation Sequence Step Step 1 2 3 4 5 6 1 2 3 4 5 6 P hase A + Z - - Z + A - Z + + Z - B Z + + Z - - B Z - - Z + + C - - Z + + Z P hase C + + Z - - Z A 1 1 0 0 0 1 A 1 1 0 0 0 1 B 0 1 1 1 0 0 B 0 1 1 1 0 0 C 0 0 0 1 1 1 C 0 0 0 1 1 1 120 Spacing Sequence Forward 120 Spacing Sequence Reverse Step 1 2 3 4 5 6 P hase A + Z - - Z + B Z + + Z - - C - - Z + + Z A 1 1 1 0 0 0 B 0 1 1 1 0 0 C 0 0 1 1 1 0 Step 1 2 3 4 5 6 A - Z + + Z - B Z - - Z + + P hase C + + Z - - Z A 1 1 1 0 0 0 B 0 1 1 1 0 0 C 0 0 1 1 1 0 60 Spacing Sequence Forward 60 Spacing Sequence Reverse + = Top Transistor ON, Bottom Transistor OFF, Current flows into this wire - = Top Transistor OFF, Bottom Transistor ON, Current flows out of this wire Z = Top Transistor OFF, Bottom Transistor OFF, No current into or out of this wire (High Impedance) Motor Connection Refer to the hookup diagram for typical driver applications. When connecting a motor for the first time, connect the hall sensor wires (5 of them) to the driver. DO NOT CONNECT THE PHASES YET. Turn on power and rotate the motor by hand. If the RED FAULT LED comes on, the hall phases are incorrectly wired. If the RED FAULT LED does not come on then the hall wires are connected correctly. Power the unit down and proceed to connect the motor phases. If the motor does not run or runs erratically, power down and check the speed potentiometer and make sure the phases are connected correctly. There are six different ways to connect the phase wires, and normally only two will allow the motor to rotate, but only one is correct. If the direction of the motor is changed and the no-load current of the motor is approximately the same and the motor runs smoothly in both directions then the phase wires are correct. The wiring of the motor phases should be separated from the hall and input connections to not allow a possible source of interference.

Terminal and Dip Switch s Pin # 1 Sensor Power 2 Sensor A 3 Sensor B 4 Sensor C 5 Sensor Ground TB1: Motor Terminals Pin # SW # 1 O/C LOOP 2 CL1 3 CL2 4 CL3 1 A 2 B 3 C TB4: Motor Terminals SW1: Dip Switch Pin # SW # 1 PG OUT(collector ) 2 PG OUT(emitter ) 3 Direction (+) 4 Direction (-) 5 Freewheel (+) 6 Freewheel (-) 7 Run/Stop (+) 8 Run/Stop (-) 9 Fault Out (collector) 10 Fault Out (emitter) TB2: Opto-isolated Control Inputs and Outputs 1 INT/EXT SPEED 2 FLT LATCH 3 RAMP 1 4 RAMP 2 5 60/120 SW2: Dip Switch Pin# 1 AC Hot 2 AC Neutra l 3 EARTH GND (must be connected) TB3: AC Voltage In Terminals T B# Pin # 1 1 Pot (+) To p 3 6 Pot Wiper 3 7 Pot (-) Bottom P1: 10K External Pot Dip Switch Settings Function SW 1 SW2 SW3 SW4 SW5 Internal External Speed Control (R46) Speed Control (P1) Over Current Latching Over Current Cycle by Cycle Ramp Profile1 (4 Sec) Ramp Profile 2 (2 Sec) Ramp Profile 3 (1 Sec) Ramp Profile 4 (500mSec ) 60 Sensor Spacing 120 Sensor Spacing Standard Product (Ready to Ship) SW2: Speed Adjustment, Over Current, and Ramp settings

Dip Switch Settings (cont.) Function SW 1 SW2 SW3 SW4 Constant Voltage Speed Mode (Closed Looped) Controlled Speed Mode (Open Loop) Closed Loop Compensation 1 Closed Loop Compensation 2 Closed Loop Compensation 3 Stnadard Producy (Ready to Ship_ SW1: Open Loop and Closed Loop. If Closed Loop selected, Closed Loop compensation switches must be set according to motor speed desired. Motor Freewheel The motor freewheel feature allows the de-energizing of the motor phases. Zero current into this input causes the motor to run at the given speed, while ~1mA into this input causes the motor to coast to a stop. Motor Run/Stop The motor run/stop feature allows the stopping of a motor by shorting out the bottom drives of the three phases. A low at this input allows the motor to run, while a high (open) input does not allow motor operation and if operating causes rapid deceleration Motor Direction The motor direction feature allows the changing of the rotation of the motor. This input should not be changed while motion is in progress. Zero current into this input causes the motor to turn in the CW direction, while ~1mA into this input causes the motor to turn in the CCW direction. Speed Adjust Setting There are two ways to set the speed on this drive. e is to use the on board or external potentiometer. To use the on board potentiometer, set INT/EXT SPD switch to the off position (default). To use the external 10K potentiometer, set INT/EXT SPD switch to the on position. If an external potentiometer is used to control the speed of the motor, connect the pot wiper to P1 - pin W, the positive end of the potentiometer to P1 - pin H and the negative end to P1 - pin L. Fault Protection and Fault Output Over current protection can be provided by means of an over current latch function by setting the FLT LATCH dip switch. If a motor current level exceeding the current limit set by the internal or external current limit potentiometer is produced, an over current latch is activated, shutting off the output. This driver is equipped with a FAULT LED to alert the user of the following conditions. 1. Invalid Sensor Input code 2. Over Current. The driver is equipped with cycle-by-cycle current limiting or over current latch. 3. Under-voltage Lockout activation at 9.1VDC for the input voltage and 4.5VDC for Sensor voltage. The Fault output on the MDC200-048051 is an opto-decoupled open collector output. When a latched fault condition occurs, no current conducts into the emitter. When normal operation occurs, this output will conduct current into the emitter. Care must be taken not to pass more than 50mA through this transistor.

Speed Output The PG OUT terminal (TB2 - pin 1 and 2) is used to determine the speed of the motor shaft. An optodecoupled open collector output is shown at a rate of 4 pulses for 1 revolution of an 8-pole motor, 3 pulses for 1 revolution of a 6-pole motor, and 2 pulses for 1 revolution of a 4-pole motor. Care must be taken not to pass more than 50mA through this transistor. # Poles RPM 8 15 * PG OUT (in Hz) 6 20 * PG OUT (in Hz) 4 30 * PG OUT (in Hz) Heating Considerations The temperature of the heat sink should never be allowed to rise above 70 degrees Celsius. If necessary, mount the unit to an additional heat sink or air should be blown across the heat sink to maintain suitable temperatures. Dimensions Figure 1: Dimensions

Typical Hookup Drawing Figure 2: Hook up for current sinking inputs Figure 3: Hook up for current sourcing inputs

COPYRIGHT Copyright 2006 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. DISCLAIMER Though every effort has been made to supply complete and accurate information in this manual, the contents are subject to change without notice or obligation to inform the buyer. In no event will Anaheim Automation be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation. Anaheim Automation s general policy does not recommend the use of its products in life support applications wherein a failure or malfunction of the product may directly threaten life or injury. Per Anaheim Automation s Terms and Conditions, the user of Anaheim Automation products in life support applications assumes all risks of such use and indemnifies Anaheim Automation against all damages. LIMITED WARRANTY All Anaheim Automation products are warranted against defects in workmanship, materials and construction, when used under Normal Operating Conditions and when used in accordance with specifications. This warranty shall be in effect for a period of twelve months from the date of purchase or eighteen months from the date of manufacture, whichever comes first. Warranty provisions may be voided if products are subjected to physical modifications, damage, abuse, or misuse. Anaheim Automation will repair or replace at its option, any product which has been found to be defective and is within the warranty period, provided that the item is shipped freight prepaid, with previous authorization (RMA#) to Anaheim Automation s plant in Anaheim, California. TECHNICAL SUPPORT If you should require technical support or if you have problems using any of the equipment covered by this manual, please read the manual completely to see if it will answer the questions you have. If you need assistance beyond what this manual can provide, contact your Local Distributor where you purchased the unit, or contact the factory direct. ANAHEIM AUTOMATION