RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

Similar documents
Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

Binary signal transmission adapter over the multimode fiber optic ELO E203, E204, E205, E206, E207. User manual

JZ878 RF Data Radio. User s Manual

Concept of Serial Communication

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Lecture #3 RS232 & 485 protocols

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

I-2533CS series User Manual

[ tima-datasheet-en v11.1 ]

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

Universal RS232/CMOS to RS422/RS485 Converter

The I-2532 CAN to Fiber Converter

There are many important factors when trying to achieve good, reliable communications between 2 devices.

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

OV-1000TSC OV-1000TLC/ Base-T to 1000Base-SX/LX Gigabit Ethernet Media Converter. User s Manual

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

SRWF-1021 Series Low Power Wireless Transceiver Data Module User Manual

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

Miniature Synchronous Multipoint Modems

FOM-4SF Sync/Async Single Fiber Modem

Catalog

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

New transmission technology on the bay/station level. ABB 1MRS WaveGuide 1

Instruction Manual MX-480 Bi-directional Multi-Protocol Data

900 MHz. Frequency Hopping RS-485 Master/Slave auto-sensing radio interface.

HAC-HM Series Data Radios

DUAL BAND FM WIRELESS TRANSCEIVER RXQ1. Applications

Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

TD_485 Transceiver Modules Application Guide 2017

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

M9606. FSK Modem. 5C Communications Inc.

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

TMX PRODUCT LINE: 4-Channel Multiplexer. CATEGORY: ISDN and T/E Carrier. S/T-Interface DS0, DS1, T1, E1, DS1C, T1C, DS2, T2, E2 FEATURES

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

4 Channel Contact Closure DIN Fiber Link System

Contents subject to revision without prior notice.

M-Bus Master MultiPort 250L Installation and User Guide

Ultrasonic Multiplexer OPMUX v12.0

Instruction Manual RT-93285SL RR-93285SL Thirty-two Channel Video Multiplexer With Two Bi-directional Data Channels

AT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

Cable and Port Specifications

Radio Data Modem MOD 02

RF7129 Ultra-low power Tranceiver module V2.0

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data

SFP Optical Transceivers

MODEL: DLS. Telemetering System

JBUS/MODBUS communication card

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

RS-232 Electrical Specifications and a Typical Connection

SWT 3000 Teleprotection technical data siemens.com

Lecture 5 Transmission. Physical and Datalink Layers: 3 Lectures

Week 2 Lecture 1. Introduction to Communication Networks. Review: Analog and digital communications

CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003

PLXDigi (v1.00) Instruction manual Configuration software manual

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

FOM-5A, 6A Asynchronous Fiber Optic Modems

FiberLink 4040 Series

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz

Industrial Automation

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

Low Power with Long Range RF Module DATASHEET Description

UK - SFP MONOMODO 20 KM 1310 NM. DTS3112L - C(D)

SPB-7920WG / SPB-7920BWG / SPB-7920AWG (SC BIDI SFP)

RF1276 Long Distance Transceiver module V2.0

CL4424. Industrial 2.4GHz ConnexLink. User s Manual Version 1.1

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

Since 1987 Developed, Created and Made in Spain NDR6 OPTIC DATA TRANSCEIVER

10/100BASE-TX to 100BASE-FX. Fast Ethernet Media Converter. Quick Installation Guide

SMARTALPHA RF TRANSCEIVER

RF ISM Transparent Transceiver Module V4.0

Catalogue

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

CM /100/1000BASE-T

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

DeltaV SISnet Fiber Components

The Price Performance Leader in 100% Compatible Optical Transceivers GBIC-GE-S40K Part Number: GBIC-GE-S40K PRODUCT FEATURES APPLICATIONS

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

AXGE Gbps Single-mode 1310nm, SFP Transceiver

ICF-1280I Series Quick Installation Guide

af i Instruction Manual MR-944C Four Channel Video Receiver With One Bi-Directional Multi-Protocol Data Channel american fibertek 11/30/2012 JPK

10/100Base. 100Base-FX Switching Converter. User s Manual

SV-MESH Mesh network series Catalogue

GCAN-208-1/-2. Fiber-CAN converter. User Manual

Product Specification RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver

FRnet Remote I/O Modules

SPB-9640G / SPB-9640BG / SPB-9640AG (SC BIDI SFP)

1 What s in the shipping package?

Transcription:

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245 Operation manual

1.0 Introduction 3 2.0 Operation principles 3 3.0 Installation 3 3.1 RS422 Interface Connection 4 3.2 RS485 Interface Connection 4 3.3 Two modems connection 5 3.4 Power Connection 6 4.0 Specification 6 4.1 Parameters 6 4.2 Other 7 5.0 Testing 7 6.0 Troubleshooting 7 7.0 Ordering Information 7 7.1 Related products 7 2

1.0 Introduction Fiber Optic (SINGLE MODE and/or MULTI MODE) has been used for signal transmission in automation for communication more and more often. The main advantage of Fiber Optic is its immunity to electromagnetic interference, slight radiation and high transmission capacity So they have been used for instance in high voltage distribution points, in the workrooms with high level of electromagnetic disturbances and in outdoor installations. 2.0 Operation principles The principles of ELO E243, E244 and E245 operation are identical. They differ as to the type of optical connector and the optical cable type. So the next parts will describe only ELO E243 and the other models will be meant just if it will be necessary to describe the differences. In duplex (RS422) mode ELO E243 transfers signal received from RS422 interface (TxD) to transmitting fiber of the optic cable and the signal from receiving fiber is transmitted to RS422 (RxD). In half-duplex (RS485) mode the data received from optics are transmitted to RS485 bus. After the end of data modem switches off its transmitter and starts listening if there is any signal from RS485 bus. In this data-flow direction switching mode only some data rates can be used. They must be set by the switches on the back side of modem. The lowest data rate is 4 800 bps and the highest one is 3 Mbps. If the modem is set correctly, the transmition is independent on communication protocol. ELO E243 and ELO E244 are designed for multimode optic fibers and ELO E245 for singlemode one. ELO E243 has optical connector ST, ELO E244 and ELO E245 have SC connectors. 3.0 Installation There are two different problems of installation to discuss: RS-485 or RS-422 link and fiber optic link connection and setting characteristics of the modem. In the RS485 mode modem needs data range and data format setting (asynchronous word length). There is the DIL switch on the back side of modem case. When the RS422 mode has been used, the setting is not necessary. 3

3.1 RS422 Interface Connection The RS422 is set when the switch No.3 is Off. The duplex interface needs 2 twisted pairs each for one direction of data flow. Contacts 3-8 are used to receive data from RS-422, 2-7 are transmitters. The terminators 120Ω can be set using the DIL switch No 1 and 2. contact signal meaning note 1 alarm optic line is out of order open collector output 2 Rx+ received data (with 7) output from modem 3 Tx+ transmitted data (with 8) input to modem 4 -- not used 5 GND signal ground 6 Vcc supply for terminator don t use as a source 7 Rx- received data (with 2) output from modem 8 Tx- transmitted data (with 3) input to modem 9 PWR alternative supply input GND contact is not used to data transfer. Despite of this fact it is useful to connect it to the opposite devices similar signal. Vcc contact is necessary to supply an active terminator which is not used in RS422 mode, but in RS485. The data rate can be any at the range from 0 to 5 Mbps. The RS422 cable length limits the maximum data rate. Mbps can be reached if the RS422 cable is about meters long. If the maximum cable length is applied the data rate can be up to 9500 bps. Signal ALARM is set if the optic line doesn t work properly. A 24 V relay can be applied if it doesn t take more than 100 ma. 3.2 RS485 Interface Connection The RS485 interface is half duplex. The signals are described below. contact signal meaning note 1 alarm optic line is out of order open collector output 2 -- not used 3 TxRx+ data (with 8) input/output - bus 4 -- not used 5 GND signal ground 6 Vcc supply for terminator see following text 7 -- not used 8 TxRx- data (with 3) input/output - bus 9 PWR alternative supply input 4

The switch No. 3 = On sets the half-duplex mode of the modem. The RS485 bus can be terminated with switch No.2 = On. The contacts 3-8 are connected to 120 Ω resistor. Some RS485 devices can have a problem how to interpret the third state of RS485 bus (the voltage between both wires is less than 200 mv). In that case it is useful to connect one external resistors 680 Ω between Vcc (+5V) and TxRx+ and second one No.5 6 7 8 data rate bps Off Off Off Off 4 800 On Off Off Off 9 600 Off On Off Off 19 200 On On Off Off 38 400 Off Off On Off 57 600 On Off On Off 62 500 Off On On Off 93 750 On On On Off 115 200 Off Off Off On 187 500 On Off Off On 230 400 Off On Off On 375 000 On On Off On 500 000 Off Off On On 750 000 On Off On On 1 000 000 Off On On On 1 500 000 On On On On 3 000 000 between SG (signal ground) and TxRx-. This active terminator will give a voltage higher than 200 mv with a polarity according to IDLE state (stop bit). For the correct operation the right data rate has to be set by the switches 5-8. Besides the data rate the data format must be set.> No.4 data parity Off 7 bit yes Off 8 bit no On 8 bit yes If the switches aren t set correctly, the data will not be damaged when they pass through the modem, but during the data flow direction switching (bad or inaccurate packet end indication). Warning!!! There is a disunity of the marks of the wires. Correctly the IDLE state (stop bit polarity) means that TxRx+ has a higher voltage than TxRx-. Some producers call the wires A-B, some B-A, but we can see also P-N, Data+ - Data- and so. If the wires aren t connected to modem correctly, the data are negated. In IDLE state modem has activated its RS485 transmitter and the other RS485 devices cannot transmit their data. 3.3 Two modems connection The fibre optic cable is connected through the ST (model E243), or SC (E244 and E245) connectors. To connect the ELO E243, the transmitter of the remote modem must be connected to the receiver of the local ELO E243 and the remote receiver must 5

be connected to the local transmitter (fibres cross). The connection is OK when the LINK indicator lights. In other case LINK doesn t shine and ALARM signal is activated. Both modems must be set to the right data range and data format in RS-485 mode. 3.4 Power Connection The external supply has to have the output voltage of 9-24V and it is connected via DC connector on the back side, or via the DB9 contacts 9 (+) and 5(-). So, one of inputs can be used for back-up supply connection. The supply take off is c.200 ma. If the supply is on operation the indicator PWR switches on. 4.0 Specification 4.1 Parameters Transmitted interface RS485/422 Transmit mode RS485 asynchronous, half-duplex Transmit mode RS422 duplex Type of RS485/422 connector DB9 female Optic connector E243 / E244 / E245 ST / SC / SC Range E243. E244 2 km typically Range E245 15 km typically Fibre optic cable two fibers E243, E244 multimode 50/125 µm (62/125µm) E245 singlemode 9/125 µm Maximum/minimum data rate RS485 3 Mbps / 4800 bps Maximum data rate RS422 5 Mbps Supply external DC supply 9-24V/260-100 ma Dimension: Length 120 mm Width 80 mm Height 25 mm Weight 160 g 6

4.2 Other Stocking temperature Working temperature Humidity -10 to +55 C +0 to +50 C 0 85% (non-condensing) 5.0 Testing In case of proper installation the PWR and LINK diode is alight. The yellow LED indicates the data transfer. 6.0 Troubleshooting Symptom ELO E24x does not work after installation In RS485 mode data are Transferred, but a part of them is lost. Connection in normal operation quit working Action Check if the PWR and LINK is alight. Check the power supply. Check the RS-485 /422 link connection. If necessary use the terminators. Check if the data rate and data format are set correctly Check how the wires are marked. Check the power supply Check if the cables are OK.. Turn off and on the power supply and detect if the modem starts again. 7.0 Ordering Information Supply codes are ELO E243 RS-485/422 / ST multimode, ELO E244 RS-485/422/ SC multimode, ELO E245 RS-485/422/ SC singlemode 7.1 Related products ELO E0Q6 DC supply 12V / 500 ma 7

8 ELOE243(45)ZKE001