Product Manual SE1000. Description The SE1000 is a microprocessor-based pulse monitoring interface designed to monitor up to four pulse inputs.

Similar documents
The MFT B-Series Flow Controller.

ELKOR MOC1 TRANSDUCER SET - MANUAL

Smartzone LCD TOUCHPAD USER GUIDE.

2015 Northwest Electric Meter School. A division of Brayden Automation Corp. Introduction to Pulse Metering, Pulse Initiators & Isolation Relays

Installation and Operating Instructions

DO NOT USE UNIT POWER

RM-2000-RTDW Remote Monitor User s Guide

METERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

SVM F22. Calculator for heating or cooling applications. Data sheet

Energy Management Energy Meter GM3T E GM3T-RS485 E

PM 305 Operating Guide

INSTALLATION INSTRUCTION SHEET MPG-1 Metering Pulse Generator

INSTALLATION INSTRUCTION SHEET MPG-1C Metering Pulse Generator

Microprocessor Control Board Set Up Procedures (OR PLC)

MODEL 421 Over/Under Motor Load Monitor

INTELLIMETER REGISTER

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

User s Manual. F2 Calculator. A metering component for thermal energy applications

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Energy Management Energy Meter Type EM21 72R Retro-Fit

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

SolarEdge Feed-in Limitation Application Note

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

EPM Single-point submetering system. imagination at work. Engineered for retrofit and new construction with power line communication capability

OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Product Specification for model TT Transducer Tester Rev. B

SolarEdge Feed-in Limitation Application Note

Global Water Instrumentation, Inc.

ET Water SmartWorks Panel Installation Guide

Model: 3283N 3283N. Demand Control Module (Interface with Utility Pulse Meter) FEATURES: APPLICATIONS:

Energy Management Energy Analyzer Type EM210 MID

Integra 1560 and 1580 Digital Transducer Systems

RISH Master 3440i/3440iDL 0.2S

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

Ziegler EM 1320/30/40

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

Energy Management Energy Analyzer Type EM210

3-phase meter with direct connection and pulse or Modbus RS485 output

ULTRA RAPID POWER QUALITY ANALYZER

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

ALPTEC POWER FACTOR CONTROLLER

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

DPF-MAC Auto power factor controller

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

Technical Specifications. Single Phase AC Static Utility Meter

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

SolarEdge Export Limitation Application Note

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM111

SUNDIAL Light Dimmer. User's Manual

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Series 962. Operation Manual. Electronic Stager Control TIME OF DAY TIME OF REGEN HARDNESS FLOW SERIES 962 CAPACITY REGEN TIME REMAINING

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management Energy Analyzer Type EM111

RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones

Wireless Analog Output Modules

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Kurz Instruments Inc. 19 August 2010

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

Polaris 2000 User s Manual

+GF+ SIGNET Temperature Transmitter Instructions

Energy Management Energy Analyzer Type EM112

NEC Display Solutions of America, Inc. UM361X & UM351W Installation Guide Desktop and Ceiling Mount v1.0

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

TRWinProg 101by Chris Bowman October 10

Owner s Manual S5 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

BOILER MANAGEMENT SYSTEM

MFJ ENTERPRISES, INC.

Din-Mon Smart Meter. Advanced kwh/demand Meters with Communication INSTALLATION INSTRUCTIONS

MultiCube Multi-Function Electricity Meter. Installation and Operation

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

M 140i. Multifunction Calibrator. Operation Manual

Energy Management Energy Analyzer Type EM280-72D

Contents. Introduction and description Package contents Device identification PM Options... 80

WIRELESS Energy Monitor - Smart Meter

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

Tarocco Closed Loop Motor Controller

NETWORK ANALYZERS Analyzers

Eltek TU GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions

APPLICATION NOTE DA-100

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x G TIMER OUTPUTS INTRODUCTION SPECIFICATIONS AUXILIARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

Printing Humidity/Temperature Meter

Issue Date: Effective Date: Supersedes: S-E-06 (rev. 6)

BCV-1203 Barcode Verification System Users Guide Version 1.2

WLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

Operator Manual 1.4 FRACSIM MINI

FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Jet Central Sequencer Plus

Model # PCYFC-10kW-250A PCYFC-20kW-250A PowerCycle Battery Conditioner Operation Manual

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

TEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.

Multi-power meter Type TMW Instruction manual digest version

BandMaster V Manual. Installation

Transcription:

Product Manual SE1 Utility Meter Pulse Transducer Communicating Controls Description The SE1 is a microprocessor-based pulse monitoring interface designed to monitor up to four pulse inputs. Features Stand-alone or network operation Independently programmable inputst 32 character LCD display Four pulse inputs Contents Description.................................. 1 Features.................................... 1 Mounting.................................... 1 Wiring...................................... 2 Programming................................ 3 Operation................................... 5 Checkout & Troubleshooting.................... 6 LED Description.............................. 7 Mounting The SE1 is designed for mounting using two #1 sheet metal screws.

Wiring The SE1 uses terminal designations for wiring. See diagram below. Powering the se1 The SE1 is powered from 24 VAC +/- 2 %. If wiring for communications, dedicated power must be used to power the SE1. Several S series controllers may be powered from the same transformer, provided that the transformer has sufficient power. (Supertrols require 5 VA @ 24 VAC.) Caution: Do not connect to 12 VAC. When multiple TCS Basys Controls devices are using a single transformer, the polarity of the power wiring must be maintained because all TCS devices are half-wave rectified and have common return paths. se1 UTILITY METER PULSE TRANSDUCER M e te r 1 D e m a n d 2 + R C P O W E R B a ref PULSE INPUTS A B R S 4 8 5 R E F D A T A 1 M E T E R 1 M E T E R 2 M E T E R 3 M E T E R 4 K/y Z K/y Z K/y Z K/y Z 3 3 3 3 1 2 3 F o r co m m u n ica tio n w irin g, u se tw iste d, sh ie ld e d 1 8 AW G. Must be run separately. 24 VAC transformer. See powering instructions. Pulse input from local utility. 2

Programming The SZ1 may be programmed through the display and keypad, or with a PC. 5. METER 1 TYPE: Meter 1 Type Screen. Select either, BTU, WATER, show if was selected in step 4. If programming with a PC, the following must be set through the keypad prior to programming: Address (step #2) Baud rate (step #3) For more information on programming through the PC, consult your TCS software manual. Programming through the Keypad To access the programming screens, press both the Scroll and Next keys simultaneously. Scroll Key - The "Scroll" key is also used to save any changes to the "current" screen and advance to the next screen while programming. The "Scroll" key is used to enter the Programming Mode when pressed with the "Next" key. Next Key - Used to enter Programming Mode when pressed with the Scroll key. Also used to exit programming without saving changes to the current screen. Increment/Decrement Keys - Used to select the desired value. Meter 1 Demand Main Monitoring Screen 6. 7. 8. 9. METER 1 CT VALUE:.6 METER 1 P/REV: 4. METER 1 CONSTANT: METER 1 CU FT/P: 5. Meter 1 CT Value Screen. input 1 (this value should be provided on selected in step 4 or if BTU, Water or Gas was selected in step 5. Meter 1 Pulse Per Revoltion Screen. for meter input 1, (this value should be provided on the CT or Energy Meter from the Utility). This screen does not show if was selected in step 4. Meter 1 Constant Screen. input 1 (this value is provided from utility was selected in step 4. Meter 1 Cubic Feet Per Pulse Screen. This only applies to Water, GAS and BTU (this value is provided from utility was selected in step 4.. kw 1. + ENTER ACCESS CODE: Access Code Entry Screen. Enter the access code. If the wrong access code is entered, the program reverts to the main screen. 248 is the default access code. 1. 11. METER 1 MULT: SETUP METER 2: Meter 1 Multiplier Screen. Enter the multiplier for meter input 1 (this selected in step 4. Meter 2 Setup Screen. input two. If no is selected skip to step 18. 2. SET ADDRESS: 1 Controller Address Screen. If using a PC to access the SE1, set a unique address from to 255, excluding 248. 12. METER 2 TYPE: Meter 2 Type Screen. Select either, BTU, WATER, show if was selected in step 11. 3. 4. SET BAUD RATE: SETUP METER 1: 9.6K Communication Baud Rate Screen. Is using a PC to access SE1, all controllers on a network must be set to the same baud rate. Choose between 2.4K, 4.8K, 9.6K and 19.2K. Setup Meter 1 Screen. input one. If no is selected skip to step 11. 13. METER 2 CT VALUE:.6 Meter 2 CT Value Screen. input 2 (this value should be provided on selected in step 11 or if BTU, Water or Gas was selected in step 12. 3

14. METER 2 P/REV: 4. Meter 2 Pulse Per Revoltion Screen. for meter input 2 (this value should be provided on the CT or Energy Meter from the Utility). This screen does not show if was selected in step 11. 23. METER 3 CU FT/P: 5. Meter 3 Cubic Feet Per Pulse Screen. This only applies to Water, GAS and BTU (this This screen does not show if was selected in step 18. 15. METER 2 CONSTANT: Meter 2 Constant Value Screen. input 2 (this value is provided from utility was selected in step 11. 24. METER 3 MULT: Meter 3 Multiplier Screen. Enter the multiplier for meter input 3 (this selected in step 18. 16. METER 2 CU FT/P: 5. Meter 2 Cubic Feet Per Pulse Screen. This only applies to Water, GAS and BTU (this value is provided from utility was selected in step 11. 25. SETUP METER 4: Meter 4 Setup Screen. input two. If no is selected skip to step 32. 17. METER 2 MULT: Meter 2 Multiplier Screen. Enter the multiplier for meter input 2 (this selected in step 11. 26. METER 4 TYPE: Meter 4 Type Screen. Select either, BTU, WATER, show if was selected in step 25. 18. SETUP METER 3: Meter 3 Setup Screen. input two. If no is selected skip to step 25. 27. METER 4 CT VALUE:.6 Meter 4 CT Value Screen. input 4 (this value should be provided on selected in step 25 or if BTU, Water or Gas was selected in step 26. 19. METER 3 TYPE: Meter 3 Type Screen. Select either, BTU, WATER, show if was selected in step 18. 28. METER 4 P/REV: 4. Meter 4 Pulse Per Revoltion Screen. for meter input 4 (this value should be provided on the CT or Energy Meter from the Utility). This screen does not show if was selected in step 25. 2. METER 3 CT VALUE:.6 Meter 3 CT Value Screen. input 3 (this value should be provided on selected in step 18 or if BTU, Water or Gas was selected in step 19. 29. METER 4 CONSTANT: 1.6 Meter 4 Constant Value Screen. input 4 (this value is provided from utility was selected in step 25. 21. METER 3 P/REV: 4. Meter 3 Pulse Per Revoltion Screen. for meter input 3 (this value should be provided on the CT or Energy Meter from the Utility). This screen does not show if was selected in step 18. 3. METER 4 CU FT/P: 5. Meter 4 Cubic Feet Per Pulse Screen. This only applies to Water, GAS and BTU (this value is provided from utility was selected in step 25. 22. METER 3 CONSTANT: 1.6 Meter 3 Constant Value Screen. input 3 (this value is provided from utility was selected in step 18. 31. METER 4 MULT: Meter 4 Multiplier Screen. Enter the multiplier for meter input 4 (this selected in step 25. 4

32. SET ACCESS CODE: 248 Access Code Screen. Enter an access code ( to 255) that will be used to enter the programming mode. The default is 248. In the following picture, both Type A and C are shown. Three pulses are shown, labeled 1, 2, and 3. Notice how the Type A output closes and opens for each pulse, where the Type C output simply changes state. 33. Meter 1 Demand Main Monitoring Screen.. kw Operation METER INPUTS There are four meter inputs available. Each one is setup for a dry contact and cannot be changed. Each input (Meter 1, Meter 2, Meter 3 & Meter 4) can be configured to accept signals representing electrical, BTU, water or gas usage. The required parameters will be provided by either the utility company involved or on the current transducer (CT) used to generate the pulse signal. METER TYPES The SE1 supports various meter types. Selecting a meter type changes the default values as they are used to calculate meter consumption and demand for that particular meter. For each of the four SE1 meter inputs, there are five selectable options: : Electric single phase meter. ELEC 3 PH: Electric three phase meter. GAS: Gas meter. WATER: Water meter BTU: BTU meter Utility pulse meters can be one of two different types, depending on whether they count the leading and trailing edges of the pulse or only the leading edge of the pulse as a single count. A pulse output can be either a mechanical relay or solid state device. The pulse output corresponds to a unit/time of a monitored quantity. The amount of time between states of a pulse output corresponds to the meter demand and the number of pulses is proportional to the meter s consumption. Below is a diagram depicting two types of utility meter pulse outputs. Meter Type A counts only the leading edge as a single pulse and the trailing edge is ignored. Meter Type C is known as a true KYZ meter and counts both the leading and trailing edges as a pulse, effectively doubling the number of pulses as seen by Meter Type A. The SE1 measures Type A output only; however, KYZ functionality can be mimicked by using a Meter Multiplier value of 2. If you have a Type C device (3 terminals KYZ), you will need to double the multiplier. The SE1 only counts the contact closures for the K and Z terminals. Doubling the multiplier will correct this problem. PROGRAMMING THE METER CONSTANTS: CT Value: The value of the CT wired to the meter. This value is usually provided on the CT or on the utility output meter. This value is only used for and electric meter. P/REV: The Pulses per revolution for the meter. This value is usually provided from the utility company. CONSTANT: The value of the constant for the meter is usually provided from the utility company and many times is located on the electric or gas bill. CU FT/P: The value for Cubic Feet per pulse. This only applies to Water, GAS and BTU, and is usually found on the utility meter itself. MULT: The multiplier for the meter can be used to scale the meter output or correct for KYZ meter. The multiplier is used to convert the pulses to engineering unit data. For example, if your meter provides one pulse per.1kwh, then a constant of.1 is required. MULTIPLIER: Each model of power meter is different and has a different multiplier. For example, if the meter is a Type A and reports 1/1 kwh per pulse, set the input multiplier to.1. If the meter is a Type C and reports 1/1 kwh per pulse, set the input multiplier to.2. You must obtain the correct pulse multiplier from the meter manufacturer prior to configuring the SE1. Some power meters have an option to configure the multiplier. Options often include 1,.1,.1, kwh per pulse. The best method to configure the pulse is to select the smallest multiplier available, considering the maximum load and pulse rate. To calculate the pulse rate, use the following formula: Pulses = KW*36*multiplier Second In general, the SE1 calculates electric meter consumption and demand as follows: R 5

Demand = ((CTValue*MtrConst*MtrMult)) (PPRValue*PulseTimeDiff) Consumption = ((PulseCount*CTValue*MtrConst*MtrMult)) PPRValue Incorrect Monitoring Value Displayed If any of the meter inputs are showing incorrect values, verify the programming parameters for that meter. If any of the meter inputs are showing, verify the pulse signal is working. See checkout for details. MONITORING Screens Continually pressing the scroll button or next button and the increment/decrement button allow more extensive monitoring. The screens are shown below. METER 1 DEMAND Main Monitoring Screen. kw The above diagram depicts how a single pulse and the pulse time difference are represented on a pulse waveform input into the SE1. Checkout & Troubleshooting Checkout 1. METER 1 DEMAND.kW Meter 1 Demand Screen. You may verify the status of each meter input by pressing the "Scroll" key and then using the "Increment" and "Decrement" keys to cycle through the various screens. 1. Verify all wiring prior to powering the controller. 2. Turn power on. The controller will display a momentary screen with the model and version number, and then the main monitoring screen. 2. METER 1 COUNT Meter 1 Count Screen. *SE1* TCS V3.(C) 3. CONSUMPTION 1. kwh Meter 1 Consumption Screen. vary Meter 1 Demand 3. Take note of the current readings for all meters. Since the SE1 is used only for monitoring, and if the readings appear to be correct, you are done. 4. METER 2 DEMAND.kW Meter 2 Demand Screen. 4. If a value does not appear to be correct, scroll through the meters to view the desired input and verify that a value (other than ) is being shown. 5. Go back into programming mode and adjust various parameters as required to make the value appear correctly. 5. METER 2 COUNT Meter 2 Count Screen. 6 If a value shown as, the SE1 is not retrieving a pulse signal. Verify the pulse signal is being generated at the meter or CT and check the input wiring. 6. CONSUMPTION 2. kwh Meter 2 Consumption Screen. vary Troubleshooting No Display Check for 24 VAC on terminals R and C. 6

7. METER 3 DEMAND.kW Meter 3 Demand Screen. 8. METER 3 COUNT Meter 3 Count Screen. 9. CONSUMPTION 3. kwh Meter 3 Consumption Screen. vary 1. METER 4 DEMAND.kW Meter 4 Demand Screen. 11. METER 4 COUNT Meter 4 Count Screen. 12. CONSUMPTION. kwh Meter 4 Consumption Screen. vary METER 1 DEMAND. kw Main Monitoring Screen LED Description PROGRAM/DATA This LED will be lit when the controller is within the programming setup menus. It will blink when the unit is being accessed by a PC. C3679 R Rev:31 7