TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Similar documents
Three-Phase Winding Ohmmeter TWA25K

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Winding Ohmmeter RMO-TW

Winding Ohmmeter RMO-TW

Three-Phase Transformer Demagnetizer DEM60

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Winding Ohmmeter & Tap Changer Test Set RMO10TW

Three-Phase Transformer Turns Ratio Tester TRT03C

True Three-Phase Transformer Turns Ratio Tester TRT63B

True Three-Phase Transformer Turns Ratio Tester TRT30A

True Three-Phase Transformer Turns Ratio Tester TRT400

True Three-Phase Transformer Turns Ratio Tester TRT63

Three-Phase Transformer Turns Ratio Tester TRT03

True Three-Phase Transformer Turns Ratio Tester TRT4x

True Three-Phase Transformer Turns Ratio Tester TRT3x

True Three-Phase Transformer Turns Ratio Tester TRT4x

Three-Phase Transformer Turns Ratio Tester TRT03B

True Three-Phase Transformer Turns Ratio Tester TRT30A

Motor Winding Ohmmeter RMO50M

RMO-A series Micro Ohmmeters

True Three-Phase Transformer Turns Ratio Tester TRT40A

Product Catalog 2014

TRAX Transformer and Substation Test System

TRAX Transformer and Substation Test System

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

TRAX Transformer and Substation Test System

TRM-203/403 transformer resistance meters

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577 Insulation Multimeters

Automatic Transformer Winding Analyser

Battery Analyzers BA6010 Series

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Importance of Transformer Demagnetization

RMO500 M I C R O O H M M E T E R

N. TEST TEST DESCRIPTION

TRM-203/TRM-403. transformer resistance meters. Vanguard Instruments Company, Inc.

N. TEST TEST DESCRIPTION

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

DC Resistance Meters 2840 Series

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

FRAX Series Sweep Frequency Response Analyzers

MIKO-9(A) MIKO-8M(A) MIKO-7M(A)

TESTRANO 600. Three-phase test system for comprehensive power and distribution transformer testing

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

High-precision portable RESISTANCE METER

METRAClip87 and 88 Clamp Multimeters

TESTRANO 600. Three-phase test system for comprehensive power transformer testing

DM-5 Power Quality Analyzer

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

GAMMA 20 DIGITAL MULTIMETER

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Wide-band Models from DC to 100 MHz

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

DC Electronic Loads 8500 Series

VFRA-25 transformer frequency response analyzer

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

True RMS Bench Multimeters 2831E and 5491B

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

SVERKER 900 Relay and Substation Test System

TORKEL 900-series Battery Load Unit

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

World-Class Accuracy & Measurement Range (40 Conventional Models)

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

ODEN AT Primary Current Injection Test System

Specifications. 744 Users Manual

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

CPC 100. Multi-functional Primary Test System for Substation Commissioning and Maintenance

TORKEL 900-series Battery Load Unit

Advanced Test Equipment Rentals ATEC (2832)

FRAX Series Sweep Frequency Response Analyzers

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

NI SCXI Specifications

High-precision process calibrator Model CED7000

1507/1503. Insulation Testers. Technical Data. Features and benefits:

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Advanced Test Equipment Rentals ATEC (2832)

SPECIFICATIONS. STS + TD 5000 FAMILY for the test of CT, VT and PT

Analog Digital Multimeter with Insulation Resistance Measurement

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Power Meter Series PM3200 Functions and characteristics

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

PCT200 SERIES CT/PT TEST SYSTEM USER MANUAL

Power supply CP-E 24/2.5

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

High precision measurement system for current and voltage IHC-A/B-RM01/03

Transcription:

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers Resistance measurement of all tap positions in all six windings performed in a single test True three-phase on-load tap changer dynamic resistance measurement Extremely quick measurement, single-step cable setup Automatic discharge process Rapid automatic demagnetization Built-in tap changer control unit Temperature measurement channel Description The TWA series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings (provided by the TWA40 model). This is performed with a one single-step cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated. Application The list of the instrument application includes: A six-winding measurement of transformer winding resistances with a one-time cable connection Quick YN mode, which enables measuring the resistances of three transformer windings in the YN configuration simultaneously (TWA40D) Dynamic resistance measurement (DVtest) of on-load tap changers, which can be performed simultaneously on all three phases, or on a single phase (TWA40D) An evaluation of synchronization between on-load tap changer phases (TWA40D) A measurement of on-load tap changer motor current by using a dedicated channel (TWA40D) A three-phase or single-phase automatic transformer demagnetization 1

Connecting the TWA to a Transformer Using two sets of four cables, all bushings of the primary and the secondary sides are connected only once. The connection to the transformer is made using two-contact clamps that provide the four-wire Kelvin test method. The figure presents the simultaneous testing of both windings (high side and low side) on a three-phase transformer. The setup time is minimized and the test is performed very quickly. The speed is increased by saturating the magnetic core through the HV and LV windings at the same time, so the total test time is very short. The TWA test leads are interchangeable with the test leads for the TRT Three-Phase Transformer Turns Ratio Testers. Benefits and Features Six-Winding Resistance Measurement The TWA injects the current with a voltage value as high as 55 V. This ensures that the magnetic core is saturated quickly and duration of the test is as short as possible. All transformer windings, both primary and secondary, can be measured with a single cable setup. The TWA has internal memory capacity to store up to 500 measurements. All measurements are time and date-stamped. The instrument is equipped with thermal and overcurrent protection. The TWA has very high ability to cancel electrostatic and electromagnetic interference that exists in HV electric fields. It is achieved by a proprietary solution applied to both the hardware construction and the application software implementation. A special mode is provided for the resistance measurement in multiple de-energized tap changer (DETC) positions. On Load Tap Changers Simultaneous Dynamic Resistance Measurement (DRM) of All Three Phases The TWA40D can be used to measure the winding resistance of the individual taps of a power transformer without discharging between the tests. The unit also checks whether the on-load tap changer (OLTC) switches without an interruption. The moment a tap position is changed from one tap to another, the device detects a sudden, very short drop of the test current. These drops called "Ripple" should be consistent, where any drop out-of-line should be investigated. Tap changer malfunctions can be detected by analyzing the measurements of transition ripple, transition time, and visualizing DRM graphs, can be observed too. The currents in all three phases are recorded simultaneously. Test currents can reach up to 40 A in total during the test. Dynamic resistance graphs are recorded for all three phases simultaneously, so the synchronization is verified using the cursors provided in the DV-Win software. All three phase traces are plotted on the same graph. In addition, the tap changer motor current is recorded, and displayed on the same graph. The built-in tap changer control unit enables remote control of the tap changer operation from the instrument's keyboard. 2

DV-Win Software The Windows-based DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It pro-vides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. The software provides an OLTC (tap changer) condition assessment through analysis of the graphs representing dynamic resistance values during the tap changer transitions. Additionally, the DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The standard interface is USB. RS232 is optional. Additional testing mode, Quick YN, is enabled by the DV-Win software for the TWA40D model. In this mode, it is possible to measure the resistances of three transformer windings in the YN configuration simultaneously. It is also possible to test the resistances of all tap changer positions of all three phases in a single pass through the tap changer positions. Tap Changer Motor Current Monitoring Channel The AC and/or DC current monitoring channel enables monitoring and recording the OLTC mechanical drive motor current during the tap changer operation on the TWA40D model. The motor current waveform (or another useful signal) is printed on the same DV-Wingenerated DRM graph, and can help in detecting OLTC mechanical problems. Motor recording allows for DRM recording using the motor operation trigger, which is useful for reactance tap changers. An AC/DC current clamp is available as an optional accessory. Automatic Transformer Demagnetization After a DC current test, such as a winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized. Also, when disconnecting a transformer from a service, some amount of magnetic flux trapped in the core could be present. The remnant magnetism can cause various problems such as erroneous measurements on a transformer, or an inrush current at start-up of a power transformer, or an incorrect operation of the protective relays due to the magnetized CT cores. To eliminate this source of potential problems, demagnetization should be performed. When the discharging process has been completed, the TWA can perform fully automatic demagnetization. Demagnetizing the magnetic core of a transformer requires alternating current applied with decreasing magnitude down to zero. The TWA provides this alternating current by 3

internally changing the polarity of a controlled DC current. During the demagnetization process the TWA supplies current at decreasing magnitude for each step, following the proprietary developed program. The TWA40D enables performing both single-phase and threephase demagnetization. Technical Data Winding Resistance Measurement Test currents: 5 ma 25 A DC (TWA25A) 5 ma 40 A DC (TWA40D) Output voltage: up to 55 V DC Measurement range: 0,1 μω - 10 kω Typical accuracy: ± (0,1 % rdg + 0,1 % F.S.) Resolution 0,1 μω 999,9 μω: 0,1 μω 1,000 mω 9,999 mω: 1 μω 10,00 mω 99,99 mω: 10 μω 100,0 mω 999,9 mω: 0,1 mω 1,000 Ω 9,999 Ω: 1 mω 10,00 Ω - 99,99 Ω: 10 mω 100,0 Ω 999,9 Ω: 0,1 Ω 1 000 Ω 9 999 Ω: 1 Ω AC Current Measurement Channel (TWA40D) Resolution: 0,1 ms Amplitude resolution: 16 bit Current Clamp Meter Specifications Nominal current: 300 A RMS or 450 A DC PK Measuring ranges: 30/300 A Frequency range: DC to 20 khz (-3 db) Resolution: ± 50 / ± 100 ma Accuracy: ± 1% of the reading Computer Interface USB Optional: RS232 Warranty Three years Data Storage 1000 internal memory positions USB flash drive feature enables storage of a huge number of measurements OLTC Dynamic Resistance Measurement Sampling rate: 0,1 ms for TWA40D, 4 ms for TWA25A Automatic open circuit detection and warning Transition current ripple measurement Transition time measurement using DV-Win software Timing measurement of different transition changes using DV-Win graph analysis tool Environmental Conditions Operating temperature: -10 ºC - + 55 ºC / 14 ºF - +131 ºF Storage & transportation: -40 ºC - + 70ºC / -40 ºF - +158 ºF Humidity 5 % - 95 % relative humidity, non-condensing Dimensions and Weight Dimensions (W x H x D): 480 mm x 197 mm x 395 mm 18.9 in x 7.8 in x 15.6 in Weight:12,8 kg / 28.3 lbs 4

Mains Power Supply Connection according to IEC/EN60320-1; UL498, CSA 22.2 Mains supply: 90 V - 264 V AC Frequency: 50/60 Hz Mains supply voltage fluctuations up to ±10 % of the nominal voltage Input power: 2 250 VA Fuse 15 A / 250 V, type F, not user replaceable Temperature Measurement One temperature measurement channel Thermometer Pt100-50 ºC +180 ºC / -58 ºF +356 ºF 50 mm x 6 mm Applicable Standards Installation/overvoltage: category II Pollution: degree 2 Low voltage directive: Directive 2014/35/EU (CE Conform) Applicable standards, for a class I instrument, pollution degree 2, installation category II : IEC EN 61010-1 Electromagnetic compatibility: Directive 2014/30/EU (CE Conform) Applicable standard EN 61326-1 CAN/CSA-C22.2 No. 61010-1, 2nd edition, including Amendment 1 All specifications herein are valid at ambient temperature of + 25 C and recommended accessories. Specifications are subject to change without notice Specifications are valid if the instrument is used with the recommended set of accessories H winding test cable set X winding test cable set Cable plastic case Current clamp 30/300 A (TWA40D) Test shunt Transport case 5

TWA Series Models TWA25A TWA40D Six-winding resistance measurement DC test current 5 ma 25 A 5 ma 25 A; up to 25 A for winding resistance measurement and up to 40 A for the 3-phase synchronization test Measurement accuracy ± (0,1 % rdg + 0,1 % FS) ± (0,1 % rdg + 0,1 % FS) Simultaneous 3-phase winding resistance measurement No (Quick YN test) DVtest sampling resolution 4 ms 0.1 ms Simultaneous 3-phase DVtest No Tap changer motor current measurement 3-phase demagnetization Interchangeable test leads with TRT turns ratio testers Resistance measurement range 0,1 µω - 10 kω 0,1 µω - 10 kω USB flash drive feature Built-in tap changer control unit No 6

Order Info Instrument with included accessories Built-in Tap Changer Control Unit DV-Win PC software including USB cable Tap Changer Control cable 5 m (16.4 ft) Mains Power cable Ground (PE) cable Recommended H winding test lead set, 4 x 10 m (32.8 ft) with TTA clamps X winding test lead set, 4 x 10 m (32.8 ft) with TTA clamps Current clamp 30/300 A power supplied from the instrument with 5 m (16.4 ft) extension (TWA40D) Cable plastic case Transport case Article No Article No HC-10-4LMCWC XC-10-4LFCWC CACL-0300-06 CABLE-CAS-03 HARD-CASE-LC Optional H winding test lead set, 4 x 15 m (49.2 ft) with TTA clamps X winding test lead set, 4 x 15 m (49.2 ft) with TTA clamps H winding test lead set, 4 x 20 m (65.6 ft) with TTA clamps X winding test lead set, 4 x 20 m (65.6 ft) with TTA clamps Test shunt 1 mω (150 A / 150 mv) Temperature sensor 1 x 50 mm (1.97 in) + 5/10/15 m (16.4/32.8/49.2 ft) External thermal printer 112 mm Bluetooth communication module Article No HC-15-4LMCWC XC-15-4LFCWC HC-20-4LMCWC XC-20-4LFCWC SHUNT-150-MK TEMP1-050-XX EPRNT-112-00 BLUETOOTH-00 IBEKO Power AB Contact Stockholmsvägen 18 Phone: +46 70 0925 000 181 50 Lidingö, Sweden E-mail: sales@dv-power.com 7