Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Similar documents
User s manual and Technical description. Self-Powered Feeder Protection REJ603

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Relion 605 series. Self-Powered Feeder Protection REJ603 Application manual

Overcurrent Protection / 7SJ45

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Stabilized Differential Relay SPAD 346. Product Guide

SPAD 346 C Stabilized differential relay

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Compact current relay and protection assemblies RXHL 401 and RAHL 401

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

SPECIFICATION FOR OVERCURRENT RELAYS

Harmonic restraint earth fault or single-phase overcurrent protection

Time over/underfrequency relay with protection assemblies

ASHIDA Numerical OC/EF Protection Relay

Time relay RXKA 1. (xx jpg) RXKA 1

SPAE 010, 011 High Impedance Protection Relay

ASHIDA Numerical 3OC + 1EF Protection Relay

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

SAMSUNG ELECTRO-MECHANICS CO., LTD

Instantaneous Overcurrent Relay

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

Product Specification sheet

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Three-phase monitoring relays CM-PFE and CM-PFE.2

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

presentation contents application advantages

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Transformer differential protection

Three-phase monitoring relay CM-PBE

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Time-overcurrent relays and protection assemblies

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

EMC standards. Presented by: Karim Loukil & Kaïs Siala

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

SAMSUNG ELECTRO-MECHANICS CO., LTD

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

PART NUMBERING SYSTEM

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relay

Three-phase monitoring relay CM-PVE

PART NUMBERING SYSTEM

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Multi-voltage Multi-function. Wiring diagram (without control signal)

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

RS Pro ENGLISH. Datasheet

Electronic timer CT-MFS.21

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

C series Product brief

Test Specification for Type Approval

Electronic timer CT-SDS.22

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

ASHIDA Numerical Directional 3OC + 1EF Protection Relay

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

SWT 3000 Teleprotection technical data siemens.com

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Type: ADR233A (ADITYA V2 Series) (Preliminary) ASHIDA Numerical 3 Phase Tx. Differential Protection Relay

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

CP-T range Product group picture

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

N. TEST TEST DESCRIPTION

RS Pro ENGLISH. Datasheet

Electronic timer CT-TGD.22

Phase and neutral overcurrent protection

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Transcription:

Relion 605 series Relion 605 series Self-Powered Feeder Protection Product Guide

Contents 1 Description...3 2 Protection functions...3 3 Application...4 4 Self-supervision...4 5 Inputs and outputs...4 6 Testing................................. 4 7 LED and FLAG indications................. 4 8 Optional HMI...4 9 Technical data........................ 5-9 10 Connection and Terminal Diagram..... 10-11 11 Dimension and Mounting............ 12-13 12 Ordering Details........................ 14 Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB Ltd.. ABB Ltd. assumes no responsibility for any errors that may appear in this document. Copyright 2010 ABB Ltd. All rights reserved. Trademarks ABB is a registered trademark of ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. 2 ABB

Issue: Dec 22, 2010 1. Description 2. Protection Functions The feeder protection relay is part of the feeder protection series of relays, intended for the protection of secondary distribution network in utilities and industries. The relay principally offers three phase nondirectional overcurrent (low-set and high-set stage) and non-directional earth-fault protection (low-set and high-set stage). The feeder protection relay is designed to be an integral part of the most popular Safering Ring Main Unit (RMU) and Safeplus compact switchgear. The relay is a selfpowered numerical relay, which derives power from the main current transformers. This way relay ensures complete installation protection even without an auxiliary supply and hence is suitable for unmanned distribution substations having no auxiliary services. Protection Functions of Protection IEC ANSI Three phase overcurrent protection, low-set stage 3I> 51 Three phase overcurrent protection, high-set stage 3I>> 50 / 51 Earth-fault protection, low-set stage I 0 > 51N Earth-fault protection, high-set stage I 0 >> 50N / 51N Three phase transformer inrush detector 3I 2f > 68 Fig. 1. Protection overview of Self-powered feeder protection with earth current measurement by internal calculation Fig. 2. Protection overview of Self-powered feeder protection with earth current measurement by external CBCT ABB 3

3. Application is intended to be used for the selective short-circuit and earth-fault protection of feeders in secondary distribution networks and for protection of transformers in utilities and industries. The relay is a self-powered Numerical relay, which does not require an external auxiliary supply voltage, making it an ideal choice for installation even in remote locations where auxiliary supplies are not available. The relay derives power for its operation from the current transformers. is primarily used in Ring Main Units (RMU) within distribution network. Relay provides earth current measurement through internal calculation or has the provision for measuring it from the external core balance current transformer (CBCT). 4. Self-supervision The relay s built-in self-supervision system continuously monitors the state of the relay hardware and the operation of the relay software. When a relay fault is detected, the IRF LED will glow red. In the event of a critical relay failure, all the protection functions of the relay will be completely blocked to prevent any incorrect relay operation. Additionally, the relay offers fail safe trip in the combined event of critical internal relay failure and phase currents exceeding twenty times the maximum nominal current value. 5. Inputs and outputs 6. Testing The special CT s for have a test winding to simulate primary current for testing of complete protection scheme including primary CT, relay, and trip coil. 7. LED and flag indications Ready LED IRF LED Trip Flag: Built-in hand-reset electromechanical flag for overcurrent or earthfault trip indication Reset pushbutton for trip flag 8. Optional HMI As a primary user interface, the has DIP switches, few LEDs and a electromechanical flag for trip indication. Although this interface is sufficient for basic self-powered protection applications, certain installations may require a interface like conventional auxilary powered relays. Such requirement can be fullfilled with the optional battery powered HMI (Human Machine Interface) which features a unique touch screen display. The available functionality with HMI, includes segregatted trip indication, events with time stamp, fault record, display of primary values, fault codes etc., which help in post fault analysis. The HMI also overcomes the limitation of setting resolution posed by DIP switches and allows finer settings as well as setting of additional parameters. Three CT inputs for phase current and internally calculated earth-fault measure ment One core balance current transformer (CBCT) input for earth fault measurement One binary input for remote trip One impulse output for low energy trip coil 4 ABB

Issue: Dec 22, 2010 9. Technical data Dimensions Width Height Depth 96 mm 160 mm 149 mm (w/o HMI), 150 mm (with HMI) Energizing Inputs Rated Frequency Phase inputs Nominal primary current 50/60 Hz ± 5 Hz CT type Rated CT current range I s (I smin - I smax ) -CT1 8-28 A -CT2 -CT3 -CT4 -CT5 Thermal withstand capability Continuously For 1 s For 3 s Dynamic current withstand: Half-wave value Earth input Rated current, I n 1 A Binary inputs Rated voltage Thermal withstand capability Continuously For 1 s Dynamic current withstand: Half-wave value Input impedance 16-56 A 32-112 A 64-224 A 128-448 A 2.5 x I smax 25 ka primary current 20 ka primary current 62.5 ka primary current 4 A 100 A 250 A < 100 mω 24-240 V AC/DC Operating range -15% +10% for AC, -30% +20% for DC Current drain Power consumption Threshold voltage Impulse voltage trip output Rated output voltage Pulse time Energy 2...15 ma < 0.8 W 13 V AC/17 V DC 12 V 30 ms 50 mj ABB 5

Setting range and accuracy Setting range of nominal current I s -CT1 8 9 10 11 12 13 14 15 16 17 18 20 22 24 26 28 -CT2 16 18 20 22 24 26 28 30 32 34 36 40 44 48 52 56 -CT3 32 36 40 44 48 52 56 60 64 68 72 80 88 96 104 112 -CT4 64 72 80 88 96 104 112 120 128 136 144 160 176 192 208 224 -CT5 128 144 160 176 192 208 224 240 256 272 288 320 352 384 416 448 Low-set phase over-current protection stage I> Measuring range Setting range of pick-up current I> Setting resolution/steps Accuracy of pick-up current Setting range of definite time delay t> 0.9 x I smin...20 x I smax 0.9...2.5 x I s I s x 0.9...2.5 (31 steps), exit ±5% of set value in the temperature range 0...70ºC ±7.5% of set value in the temperature range -40...85ºC 0.05...3.0 sec Setting resolution/steps 0.05, 0.07, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.6, 0.8, 1.0, 1.4, 1.8, 2.2, 2.6, 3.0 Accuracy of operate time Setting of inverse time characteristics Setting range of time multiplier k 0.05...3.0 ±1% or 10 ms, whichever is greater IEC 255-3: Normal Inverse, Very Inverse, Extremely Inverse, Long time Inverse Special Curves: RI Inverse Time, HR-Fuse, FR-Fuse Setting resolution/steps 0.05, 0.07, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.6, 0.8, 1.0, 1.4, 1.8, 2.2, 2.6, 3.0 Accuracy of operate time IEC characteristics RI characteristics HR, FR curve characteristics High-set phase overcurrent protection stage I>> Setting range of pick-up current I>> Setting resolution/steps Accuracy of pick-up current Setting range of definite time delay t>> class E(5) or ±35 ms, whichever is greater As per NI(IEC) curve ±20% of set value or ±35 ms, whichever is greater 0.04...3.0 sec Setting resolution/steps 0.04, 0.07, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.6, 0.8, 1.0, 1.4, 1.8, 2.2, 2.6, 3.0 Accuracy of Operate time 1...20 x I s I s x 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14,16, 18, 20, exit ±5% of set value in the temperature range 0...70ºC ±7.5% of set value in the temperature range -40...85ºC ±1% or 10 ms, whichever is greater 6 ABB

Issue: Dec 22, 2010 (continued) Low-set earth-fault protection stage I 0 > Nominal value of earth current Internal measurement External measurement Measurement range I s I n : 1 A 0.9 x I smin...20 x I smax / 0.1...20 x I n Setting range of pick-up current I 0 > 0.1...1 x I s / 0.1-1 x I n Setting resolution/steps I s or I n x 0.1 1.0 (31 steps), exit Accuracy of pick-up current Internal measurement External measurement Setting range of definite time delay t 0 > ±3% of I s in the temperature range 0...70ºC ±7.5% of I s in the temperature range -40...85ºC ±5% of I n in the temperature range 0...70ºC ±20% of I n in the temperature range -40...85ºC 0.05...3.0 sec Setting resolution/steps 0.05, 0.07, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.6, 0.8, 1.0, 1.4, 1.8, 2.2, 2.6, 3.0 Accuracy of operate time Setting of inverse time characteristics ±1% or 10 ms, whichever is greater IEC 255-3: Normal Inverse, Very Inverse Extremely Inverse, Long time Inverse Special Curves: RI Inverse Time, HR-Fuse, FR-Fuse Setting range of time multiplier k 0 0.05 3.0 Setting resolution/steps 0.05, 0.07, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.6, 0.8, 1.0, 1.4, 1.8, 2.2, 2.6, 3.0 Accuracy of operate time IEC characteristics RI characteristics HR, FR curve characteristics High-set earth-fault protection stage I 0 >> Setting range of pick-up current I 0 >> Setting resolution/steps Accuracy of pick-up current Internal measurement External measurement Setting range of definite time delay t 0 >> class E(5) or ±35 ms, whichever is greater As per NI(IEC) curve ±20% of set value or ±35 ms, whichever is greater 1...20 x I s / 1...20 x I n I s or I n x 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14,16, 18, 20, exit ±3% of set value in the temperature range 0...70ºC ±7.5% of set value in the temperature range -40...85ºC ±5% of set value in the temperature range 0...70ºC ±15% of set value in the temperature range -40...85ºC 0.04...3.0 sec Setting resolution/steps 0.04, 0.07, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.6, 0.8, 1.0, 1.4, 1.8, 2.2, 2.6, 3.0 Accuracy of operate time ±1% or 10 ms, whichever is greater ABB 7

Degree of protection by enclosure Front portion with cover IP 54 Side with connection terminals IP 20 Environmental conditions and tests Environmental conditions Service temperature range Relative humidity < 93% Atmospheric pressure Altitude Transport and storage temperature range Environmental tests Dry heat test According to IEC 60068-2-2 16 h at +70ºC 96 h at +85ºC Dry cold test According to IEC 60068-2-1 16 h at -25ºC 96 h at -40ºC Damp heat test, cyclic According to IEC 60068-2-30 2 cycles at +25...55ºC humidity 95...97% Damp heat test, steady state According to IEC 60068-2-78 96 h at +40ºC humidity 94% Storage test According to IEC 60068-2-48 96 h at +85ºC 96 h at -40ºC Electromagnetic compatibility tests The EMC immunity test level meets the requirements listed below: 1 MHz burst disturbance test Common mode Differential mode Electrostatic discharge test Contact discharge Air discharge -25...+85ºC (relay without HMI) -25...+70ºC (relay with HMI) 86...106 kpa up to 2000 m -40...+85ºC According to IEC 61000-4-12 and IEC 60255-22-1 2.0KV, 1MHz, 400 pulses/sec 1.0KV, 1MHz, 400 pulses/sec According to IEC 60255-22-2, class III, 6kV, 150 pf/330 Ω 8kV, 150 pf/330 Ω Radiated, electro-magnetic field immunity test According to IEC 60255-22-3, level III, 10 V/m, f = 80 1000 MHz 8 ABB

Issue: Dec 22, 2010 (continued) Electrical fast transient disturbance test According to IEC 60255-22-4, class A, 4 kv, 2.5 khz Surge immunity test Common mode Differential mode Immunity to conducted disturbances induced by radio frequency fields Conducted and radiated radio-frequency emission tests Conducted emission (mains) Radiated emission Power frequency magnetic field immunity test Continuous Short duration (10 s) According to IEC 60255-22-5, and IEC 61000-4-5 1 kv, 1.2/50 μs, R s =42 Ω 0.5 kv, 1.2/50 μs, R s =42 Ω According to IEC 60255-22-6, level III, 10V, f=150 KHz 80 MHz 27MHz and 68 MHz (spot freq.) According to IEC 60255-25, EN550 11-CISPR II Frequency range: 30-230 MHz, Limits db(μv/m):40 Frequency range: 230-1000 MHz, Limits db(μv/m):47 According to IEC 61000-4-8 level V, 100 A/m 300 A/m Pulse magnetic field immunity test According to IEC 61000-4-9, 1000 A/m, 6.4/16 μs Tr/Th Insulation and mechanical tests Insulation tests Dielectric test According to IEC 60255-5, 2 KV, 50 HZ for 1 min. Impulse voltage test According to IEC 60255-5, 5 kv, 1.2/50 μs, 0.5 J Insulation resistance test >100 M Ω at 500 V DC Mechanical tests Vibration tests Response Endurance Shock test Response Withstand Bump test According to IEC 60255-21-1, class 1, Test values 10...150 Hz, 0.035 mm/0.5 g, 1 sweep/axis 10...150 Hz, 1 g, 20 sweeps/axis According to IEC60255-21-2, class 2, 10 g, 3 pulses in each direction 30 g, 3 pulses in each direction According to IEC60255-21-2, class 2, 20 g, 1000 bumps in each direction ABB 9

10. Connection and terminal diagram S1 S2 C D Meas urement Test X2-3 / S1 X2-4 / S2 X2-1 / C X2-1 / D X1-7/ TC(+ ) X1-8/ TC(-) L3 S1 X2-7 / S1 Meas urement S2 C D Test X2-8 / S2 X2-5 / C X2-6 / D L2 N S1 Meas urement X1-4 / S1 S2 C Test X1-3 / S2 X1-5 / C L1 D X1-6 / D X1-2 / S1 X1-2 / S2 E X1-9 / BI (+) X1-10 / BI(-) X2-9 / E X2-10 / E Fig. 3. Connection diagram of Self-powered feeder protection 10 ABB

Issue: Dec 22, 2010 X1 X2 10 BI (-) Binary Input 10 Earth N 9 BI (+) Binary Input 9 Earth 8 TC (-) Trip Coil 8 S2 CT Input, Phase L2 7 TC (+) Trip Coil 7 S1 CT Input, Phase L2 6 D Test Winding L1 6 D Test Winding L2 L1 5 C Test Winding L1 L2 5 C Test Winding L2 4 S1 CT Input, Phase L1 4 S2 CT Input, Phase L3 3 S2 CT Input, Phase L1 3 S1 CT Input, Phase L3 2 S1 CT Input, Earth 2 D Test Winding L3 E 1 S2 CT Input, Earth L3 1 C Test Winding L3 Test socket Fig. 4. Terminal arrangement of Self-powered feeder protection ABB 11

11. Dimensions and mounting Fig. 5. Dimension and mounting details of Self-powered feeder protection without HMI 12 ABB

Issue: Dec 22, 2010 Fig. 6. Dimension and mounting details of Self-powered feeder protection with HMI ABB 13

11. Ordering details Relay Order Codes : For with HMI : BBB10NN31C For without HMI : BBB10NN3XC For Add-on HMI kit : BNNNNNNBZA Current Transformer Note: The requires specific ring CT s to be used for phase current measurement. It is not compatible with conventional 1 A/ 5 A CT s. The primary current setting range is adequately covered by following 4 variants of CT s. CT type -CT1 -CT2 -CT3 -CT4 -CT5 Rated CT current range Is 8-28A 16-56 A 32-112 A 64-224 A 128-448 A For further technical information on current transformers and ordering information, please refer to the datasheet ref. 1YMA583791R0001-4. 14 ABB

Contact us ABB Ltd, Distribution Automation Maneja Works Vadodara-390013, India Phone: +91 265 2604386 Fax: +91 265 2638922 www.abb.com/substationautomation 1MDS07208-YN Rev C DEC 2010 Copyright 2010 ABB. All rights