Model 3116 Double-Ridged Waveguide Horn

Similar documents
Model 3106 Double-Ridged Waveguide Horn

Model 3110B Biconical Antenna

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Model 3148 & Log-Periodic Dipole Array Antenna

Model 3142B BiConiLog Antenna

Model Series. Current Probes MANUAL L L. ETS-Lindgren February 2005 Rev D PN

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

Double-Ridged Waveguide Horn Antennas

Log Periodic Dipole Array Antenna

MODEL 3810/2 Line Impedance Stabilization Network

Double-Ridged Waveguide Horn Model 3115 User Manual

Advanced Test Equipment Rentals ATEC (2832)

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

AK-18G Antenna Kit Operation Manual

Model 3104C. Biconical Antenna. User Manual

Model 3180B Mini-Bicon Antenna User Manual

Current Probe Fixture Instruction Manual

SAS-543 Biconical Antenna Operation Manual

Model Biconical Antenna. User Manual

SAS Log Periodic Antenna Operation Manual

Model BiConiLog Antenna. User Manual

Bulk Current Injection Probe Test Procedure

Model 3140B BiConiLog Antenna User Manual

Broadband Current Probe Series Operation Manual

Broadband Current Probe Series Operation Manual

Model Biconical Antenna. User Manual

TDS-535 Tuned Dipole Set Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

AK-285R Shielding Effectiveness Antenna Kit Operation Manual

SAS-563B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

Double-Ridged Waveguide Horn

Double-Ridged Waveguide Horn

o-ring grease can be used to hold the o-ring in the groove during installation.

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

o-ring grease can be used to hold the o-ring in the groove during installation.

Current Probes. User Manual

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

MANUAL. PCD - Precision Conical Dipole Antenna

Double-Ridged Waveguide Horn

SAS-551 Passive Monopole Antenna Operation Manual

Model 935A Current Source Operation Manual

Log Periodic Antenna

USER GUIDE. WR284 Waveguide TRL Calibration Kit GHz. Models: WR284C30\32 Series (Rev A) 03/16

PARABOLIC ANTENNA MODEL MTA GHz 10.0 GHz

Advanced Test Equipment Rentals ATEC (2832)

MaxLite LED Self-Driven LiteBars

supplied o-ring grease can be used to hold the o-ring in the groove during installation.

GNSS-750 ANTENNA GUIDE SITE SELECTION GUIDELINES. Additional Equipment Required. Accessories

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Type N Coaxial Calibration Kit

USER GUIDE 2.92mm Coaxial Calibration Kit

AMP-13 OPERATOR S MANUAL

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

PARALLEL ELEMENT ANTENNA MODEL PEA-30

Portable HF Magnetic Loop Antenna System Model HF-315

Instruction Manual Model M Switch, DPDT, Manual Select

GPS-701-GGL and GPS-702-GGL

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Broadband Step-Up Transformer. User Manual

THANK YOU FOR PURCHASING OUR STUDIO RTA CREATION STATION

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

Single Flex and Double Flex Couplings (i)

ADJUSTABLE MOUNTING POST

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

OMNI-DIRECTIONAL WIDEBAND ANTENNA MODEL EM GHz - 18 GHz

LUDLUM MODEL ALPHA SCINTILLATOR DETECTOR. May 2017

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 1792 VHF Radio. User s Manual. Rev. B FAA APPROVED NOT FAA APPROVED. ECP Dec 30

LUDLUM MODEL Low Energy Beta-Gamma Detector. December 2012 Serial No. PR and Succeeding Serial Numbers

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Unirac Flat Flashing INSTALLATION MANUAL

3M Shielded Controlled Impedance (SCI) Latch/Eject Header 2 mm Development Kit Instructions

Model 1791 VHF Radio User's Manual

PTT- Z or PTT-U PUSH-TO-TALK Specification

THANK YOU FOR PURCHASING OUR STUDIO RTA PROJECT STATION

GPS-703-GGG and GPS-703-GGG-N

Installation Instructions Hustler Collinear Two Meter Fixed Station Antenna Master Gainer Model G6-144B

3M Locator Plate

TENNADYNE TD-160HP800

EMC Precompliance Systems and Accessories Catalog

Soil Moisture Smart Sensors (S-SMx-M005)

LUDLUM MODEL ALPHA SCINTILLATOR DETECTOR. April 2011

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

Signal Integrity Test Report

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

AIS 300 Installation Instructions

TIA-3000 Optical/Electrical Converter. Operating Instructions

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

SRS-200 Solar Radiation Sensor Installation and Setup Instructions. SRS-200 with optional Leveling Plate and Mounting Bracket. Revision 2.0.

UNCONTROLLED WHEN PRINTED

LUDLUM MODEL BGO Scintillator. June 2018

INSTALLATION & OPERATING INSTRUCTIONS

Transcription:

Model 3116 Double-Ridged Waveguide Horn MANUAL EMC TEST SYSTEMS, L.P. MARCH 2002

EMC Test Systems, L.P. reserves the right to make changes to any product described herein in order to improve function, design or for any other reason. Nothing contained herein shall constitute EMC Test Systems, L.P. assuming any liability whatsoever arising out of the application or use of any product or circuit described herein. EMC Test Systems, L.P. does not convey any license under its patent rights or the rights of others. Copyright 2002 by EMC Test Systems, L.P. All Rights Reserved. No part of this document may be copied by any means without written permission from EMC Test Systems, L.P. E-MAIL & INTERNET Support@ets-lindgren.com http://www.ets-lindgren.com USA 1301 Arrow Point Dr., Cedar Park, TX 78613 P.O. Box 80589, Austin, TX 78708-0589 Tel 512.531.6400 Fax 512.531.6500 FINLAND Euroshield OY Mekannikontie 1 27510, Eura, Finland Tel 358.2.838.3300 Fax 358.2.865.1233 SINGAPORE Lindgren RF Enclosures Asia-Pacific 87 Beach Road #06-02 Chye Sing Building Singapore 189695 Tel 65.536.7078 Fax 65.536.7093 EMC TEST SYSTEMS, L.P. MARCH 2002

Table of Contents INTRODUCTION... 1 MOUNTING INSTRUCTIONS... 2 APPLICATION... 4 TYPICAL DATA... 5 SPECIFICATIONS... 7 MAINTENANCE... 8 WARRANTY STATEMENT... 9 EMC TEST SYSTEMS, L.P. MARCH 2002

EMC TEST SYSTEMS, L.P. MARCH 2002

Introduction INTRODUCTION The ETS-Lindgren EMCO brand Model 3116 Double- Ridged Waveguide Horn Antenna is a linearly polarized broadband antenna covering the frequency range of 18 GHz up to 40 GHz. The Model 3116 was designed and built specifically for emissions and susceptibility testing. The antenna is precision machined from aluminum. A 50 Ω type K female connector is mounted on the base block of the antenna for increased performance at high frequencies. Although the type K connector mates with type SMA connectors when used with SMA connectors the high frequency performance will be limited to the rating of the SMA connector. It is recommended that cables with type K connectors be used to ensure optimal performance. EMC TEST SYSTEMS, L.P. MARCH 2002 1

Mounting Instructions MODEL 3116 DOUBLE-RIDGED WAVEGUIDE HORN MOUNTING INSTRUCTIONS The Model 3116 can easily be mounted on a variety of tripods including the ETS-Lindgren Model 4-TR. The Model 3116 consists of the following: 1 ea Double Ridged Waveguide Horn 1 ea Mounting Bracket drilled to accept ETS-Lindgren or other tripod mount with ¼-20 threads 2 ea Thumb screws for attaching the horn to the mounting bracket NOTE When removing the Model 3116 from its mounting bracket, take care to ensure that the antenna is supported while removing the thumbscrews. Failure to support the antenna when removing the thumbscrews could result in damage to the antenna. Step 1. Before the antenna is mounted on a tripod the user will need to unscrew the thumbscrews and separate the antenna from the mounting bracket and set it to the side. Step 2. To mount the antenna on the tripod, attach the mounting bracket to the tripod with the ¼-20 bolt. To attach the antenna to the mounting bracket, with the connector facing downward and while holding the antenna with one hand, line up the holes on the back of the horn with the holes on the bracket and insert and tighten both thumbscrews. Back Plate of Model 3116 Thumbscrew Holes 2 EMC TEST SYSTEMS, L.P. MARCH 2002

Mounting Instructions Step 3. To rotate the antenna, while holding the antenna with one hand remove both thumbscrews from the mounting bracket. Rotate the antenna so the bracket holes line up with the two horizontal mounting holes on the back of the antenna. Reinsert and tighten the thumbscrews. Thumbscrews Mounting Bracket Type K Connector NOTE This illustration shows the Model 3116 vertically polarized for the purpose of introducing the primary mounting components. Typically the horn will be mounted in the horizontally polarized position for testing. EMC TEST SYSTEMS, L.P. MARCH 2002 3

Application MODEL 3116 DOUBLE-RIDGED WAVEGUIDE HORN APPLICATION Each Model 3116 Double-Ridged Waveguide Antenna is individually calibrated during the manufacturing process. Apparent gain at 1 meter from the end of the antenna is determined and included in this manual. This factor should be used in specification compliance testing to convert receiver reading (dbuv) to field intensity units (dbuv/m). This conversion is accomplished by adding the antenna factor in db to the receiver reading in db above 1 microvolt. To produce specific field strengths at one meter spacings see the Forward Power data on page 6. 4 EMC TEST SYSTEMS, L.P. MARCH 2002

Typical Data TYPICAL DATA 60 56 52 db 1/m 48 44 40 15 20 25 30 35 40 Frequency (GHz) Model 3116 Antenna Factor 20 18 16 db 14 12 10 15 20 25 30 35 40 Frequency (GHz) Model 3116 Gain EMC TEST SYSTEMS, L.P. MARCH 2002 5

Typical Data MODEL 3116 DOUBLE-RIDGED WAVEGUIDE HORN 10.0 8.5 7.0 VSWR 5.5 4.0 2.5 1.0 15 20 25 30 35 40 Frequency (GHz) Model 3116 VSWR 100 10 1 V/m CW 1 V/m 80%AM 3 V/m CW 3 V/m 80%AM 10 V/m CW 10 V/m 80%AM Forward Power (W) 1 0.1 0.01 1E-3 15 20 25 30 35 40 Frequency (GHz) Model 3116 Forward Power at 1 meter 1V/m to 10 V/m Maximum Continuous Power for the Model 3116 is 50 Watts The Maximum Peak Power Rating for this model is 70 Watts 6 EMC TEST SYSTEMS, L.P. MARCH 2002

Specifications SPECIFICATIONS Electrical Frequency Range 18-40 GHz VSWR Ratio (AVG) <1.6:1 Maximum Continuous Power Peak Power Impedance Connector Front to Back Ratio Cross Polarization 50 Watts 70 Watts 50 Ω Type K female 20 db 20 db minimum Physical Width Depth Height Weight 13 cm 5.2 in 10 cm 4.0 in 6 cm 2.4 in 135.0 g 4.7 oz EMC TEST SYSTEMS, L.P. MARCH 2002 7

Maintenance MODEL 3116 DOUBLE-RIDGED WAVEGUIDE HORN MAINTENANCE To ensure reliable and repeatable long-term performance, annual recalibration of your antenna by ETS-Lindgren s experienced technicians is recommended. Our staff can recalibrate almost any type or brand of antenna. Please call to receive a Service Order Number prior to sending an antenna to us for calibration. For more information about our calibration services or to place an order for antenna calibration visit our calibration website at http://www.antennacalibration.com. 8 EMC TEST SYSTEMS, L.P. MARCH 2002

Warranty Statement WARRANTY STATEMENT EMC Test Systems, L.P., hereinafter referred to as the Seller, warrants that standard EMCO products are free from defect in materials and workmanship for a period of two (2) years from date of shipment. Standard EMCO Products include the following: Antennas, Loops, Horns GTEM cells, TEM cells, Helmholtz Coils LISNs, PLISNs, Rejection cavities & Networks Towers, Turntables, Tripods & Controllers Field Probes, Current Probes, Injection Probes If the Buyer notifies the Seller of a defect within the warranty period, the Seller will, at the Seller s option, either repair and/or replace those products that prove to be defective. There will be no charge for warranty services performed at the location the Seller designates. The Buyer must, however, prepay inbound shipping costs and any duties or taxes. The Seller will pay outbound shipping cost for a carrier of the Seller s choice, exclusive of any duties or taxes. If the Seller determines that warranty service can only be performed at the Buyer s location, the Buyer will not be charged for the Seller s travel related costs. This warranty does not apply to: Normal wear and tear of materials Consumable items such as fuses, batteries, etc. Products that have been improperly installed, maintained or used Products which have been operated outside the specifications Products which have been modified without authorization Calibration of products, unless necessitated by defects THIS WARRANTY IS EXCLUSIVE. NO OTHER WARRANTY, WRITTEN OR ORAL, IS EXPRESSED OR IMPLIED, INCLUDING BUT NOT LMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE REMEDIES PROVIDED BY THIS WARRANTY ARE THE BUYER S SOLE AND EXCLUSIVE REMEDIES. IN NO EVENT IS THE SELLER LIABLE FOR ANY DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO, DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY. Note: Please contact the Seller s sales department for a Return Materials Authorization (RMA) number before shipping equipment to us. EMC TEST SYSTEMS, L.P. MARCH 2002 9