Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230

Similar documents
Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Energy Management Energy Meter Type EM110

05/09/2012

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8

Instruction manual. art Installation manual

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

02/11/2015

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

08/07/2015

02/11/2015

02/11/2015

Type CP-S, CP-C & CP-A Switch mode

EIB/KNX Switch Actuators. User manual

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Energy Management Energy Meter Type EM340

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

LED Driver Compact dimming

22/10/2012

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Output Voltage Range (V) PF-P250CC-C105-S(U)-ND 90 ~ ,0 UL CE ENEC CB

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Universal Radio Cord Dimmer Order No.: Function

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Power Factor (2) Efficiency (2) 25~ 49 Vdc 66 W 87 % 0.96 LUC-066T045DDM(SDM) 20~ 40 Vdc 66 W 86 % 0.96 LUC-066T056DDM(SDM)

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

Electronic timer CT-TGD.22

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

HEC-100RTA-48QSCA Rev A1.0

LED Driver Compact dimming

Output Voltage Range ma ma 700 ma 176~305 Vac 160~357 Vdc 250W 93% 0.98 EBD-255S105DV

User Manual 3X300 DIMMER MODULE DM03B02KNX

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Power Factor (1) Efficiency (1)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

LED control gear Compact dimming. Uconverter LCBI 10 W 180/350/500 ma phase-cut/1 10 V lp BASIC series

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Energy Management Energy Meter Type EM110

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL series. PCA TCL EXCEL one4all lp Y, 55 W Compact and T5c fluorescent lamps

Power Factor (2) Efficiency (2) 25~ 49 Vdc 66 W 87 % 0.96 LUC-066T045DDM(SDM) 20~ 40 Vdc 66 W 86 % 0.96 LUC-066T056DDM(SDM)

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 97~214 Vdc 150 W 93.0% 0.98 EBD-150S105DVA

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Energy Management Energy Meter GM3T E GM3T-RS485 E

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

LED converter Linear / area dimming. Uconverter LCAI 80 W 350 ma one4all V ECO

Soft starters with internal by-pass

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

LED Driver Linear / area fixed output

50W Constant Current (700mA) Dimming LED Driver

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 60~120Vdc 42 W 90.0% LUC-042S035DTG(STG)(2)

CP-E range Benefits and advantages

RS Pro ENGLISH. Datasheet

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

MINI-PS AC/2X15DC/1

Power Factor (1) Efficiency (1) Parameter Min. Typ. Max. Notes A Measured at full load and 100 Vac input

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Features. Models Output Current Range. LUD-060SxxxDSF. 60W Programmable IP20 Driver. Dim-to-off with Standby Power 0.5 W

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

PCA T8 EXCEL one4all lp Y, W T8 fluorescent lamps

Inputs/Outputs dimmer outputs 700W 2 inputs 0-10V or 1-10V for emergency operation or standalone operation

C-Bus DSI Gateway. 5508DSIP Series. Installation Instructions

Power supply CP-E 24/2.5

08/07/2015

Power Factor (1) 350 ma 176 ~ 264 Vac Vdc 24 W 84% 0.95 LHC-024S035RSP. Efficiency (1)

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

Power supply CP-D 24/4.2 Primary switch mode power supply

Energy Management Energy Analyzer Type EM111

Power supply CP-E 24/20.0

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Max. Output Power. Efficiency (2) 350 ma 90~305 Vac 14~29 Vdc 10 W 80% 0.94 LUC-010S035DSM(SSM)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

PACSystems* RX3i IC695MDL765

CP-T range Benefits and advantages

Transcription:

Smart-house Dimmer Power dimmer up to 500W Type SH2D500W230 Universal dimmer switch for R, L, C up to 500W and LED loads Automatic load detection for L, R, C loads Integrated heat sink for temperature dissipation 1 dimmable output Addressing via BGP-COBAT 2 DI housing Soft start/stop Protected against short circuit, overload and high temperature Minimum load 3 W Product Description This 500W universal dimmer is designed for DI-rail mounting and is 2 DI wide. This universal dimmer is suitable for dimming resistive, inductive and capacitive loads and LED lamps (see LED lamps table). The maximum connected load is 500W depending on the temperature: the reduction is described according to the trend in derating curve. The dimmer automatically detects if the connected load is resistive, capacitive or inductive, but if a LED lamp is to be driven, the user has to select the right curve as described below. The dimmer is provided with memory for the last selected scenario. The technology used enables to electrically protect the dimmer against short circuit, overload and over-temperature. Thanks to the internal bus, it can be easily connected to adjacent dimmers (see wiring diagram ) without the need of cabling the Dupline BUS. Futhermore, the integrated sink allows you to mount the dimmers adjacently without any reduction of the load due to the increased temperature. Ordering Key Smart-house DI housing 2 modules Dimmer Maximum load Power supply S H 2 D 500W 230 Type Selection Housing Mounting Max. load Output type Supply: 115 to 230 VAC 2 DI DI-rail 500W Power mosfet SH2D500W230 Output Specifications Maximum load 500 W ote: this is the maximum power supplied to the load: if an inductive transformer is used, the efficiency of about 60% has to be considered before connecting the lamps. If a capacitive transformer is used, the efficiency is about 90%. Minimum load 3 W @ 230 V, 6 W @ 115V Protections Overload, short circuit, thermal Output type Power mosfet Rated operational voltage 115/240 VAC Operational voltage range 90 to 260 VAC Rated operational frequency 50/60 Hz Dimming speed Programmable Types of dimmable lamps Incandescent (R) Different types of outputs (L,C) LV halogen lamps with can not be mixed electronic ballast (C) LV halogen lamps with conventional transformer (L) HV halogen lamps (R) 115/230V dimmable LED lamp ESL (Electron Stimulated Luminescence) lamps otes: if energy saving lamps are used, attention has to be paid to the maximum inrush current at start-up: it must not be greater than 3.5A otherwise the overload protection will be activated. Specifications are subject to change without notice (27.06.12) 1

Input Specifications Key Pad One push button on local dimmer Dupline Output Specifications Voltage Maximum dupline voltage Minimum dupline voltage Maximum dupline current 8.2 V 10 V 4.5 V 2 ma Supply Specifications Power supply Overvoltage cat. II (IEC 60664-1, par. 4.3.3.2) Rated operational voltage 115/240 VAC Operational voltage range 90 to 260 VAC Rated impulse voltage 2.5 kv Rated operational power 1 W Connection 6 x 6 mm2 Power on delay Typ. 2 s General Specifications Installation category Dielectric strength Power supply to Dupline and Dupline to Output Channel Programming Fail-safe mode Cat. II 4 KV AC for 1 min. 6 KV impulse 1.2/50 s (IEC60664-1, TAB. A.1) By BGP-COBAT and special cable GAP-THL-CAB In case of interruption of the connection, the light will be switched O at the memorized level or it will be switched OFF according to the status programmed with BGP-COBAT. Fail-safe bit = 0 (default condition) memory of the previous state. Fail-safe bit = 1 output OFF Environment Degree of protection Front IP 50 Screw terminal IP 20 Pollution degree 2 (IEC 60664-1, par. 4.6.2) Operating temperature -20 to +50 C (-4 to 122 F) Storage temperature -50 to +85 C (-58 to 185 F) Humidity (non-condensing) 20 to 80% RH LED s indication Unlock 1 green Dupline status 1 yellow Output status 1 red Connection Terminal 6 Screw-type Cable cross-section max. 6 mm 2, min. 0,5 mm 2 Tightening torque 0.4 m / 1 m Housing Dimensions 2 DI module Material oryl Weight 150 g CE Marking Yes EMC Immunity E 61000-6-2 - Electrostatic discharge E 61000-4-2 - Radiated radiofrequency E 61000-4-3 - Burst immunity E 61000-4-4 - Surge E 61000-4-5 - Conducted radio frequency E 61000-4-6 - Power frequency magnetic fields E 61000-4-8 - Voltage dips, variations, interruptions E 61000-4-11 Emission E 61000-6-3 - Conducted and radiated emissions CISPR 22 (E55022), cl. B - Conducted emissions CISPR 16-2-1 (E55016-2-1) - Radiated emissions CISPR 16-2-3 (E55016-2-3) Mode of Operation Push button The push button can be used with a short or long pulse (>2 seconds) and its behavior is the same of channel1. Short pulse: the light is switched O/ OFF (toggle function) with the set value. Factory settings is 100%, so the first time this push button is pressed with a short pulse, the light is switched O to 100%. If a different light scene is memorised in the module, the light is switched O at that level. Long pulse: once the light is O, by keeping the key pressed for more than 2 seconds, the light will be increased up to 100% and then decreased down to 5%. This will be repeated until the key is kept pressed. Every time the button is pressed, the ramp is inverted. The push button is also used to enable/disable the programming access (see below). Coding With the BGP-COBAT programming unit, each switching channel can be assigned any address between A1 and P8: this is retained permanently, but may be overwritten at any time. To access the pins for programming, open the cover on the front of the dimmer module (see fig. on the left). Pay attention to connect the BGP-COBAT without supply voltage on the dimmer. 2 Specifications are subject to change without notice (27.06.12)

Mode of Operation (cont.) The allocation of the channels is as follows: I/O Channel Description 1 O/OFF/Dimming 2 Light scene 1 (3) 3 Light scene 2 (4) 4 Dimmer output status 5 OFF 6 LED curves 7 Soft start/stop speed 8 Dimming speed Functions which are not required should remain uncoded. The dimmer output is configured in such a way at the factory that it will be switched off in case of a fault. Functions and programming The dimmer is programmed with the BGP-COBAT programming unit. Up to 8 addresses can be programmed, (I/ 1-3 of the BGP-COBAT) are dedicated to control the dimmer itself (light level) - see the following table "Channel Programming". One address (I/ 4 of the BGP-COBAT) is the output signal on the bus and indicates if the dimmer is active. The addresses are selected in the configuration software as push button channels. Address 6, 7 and 8 are special functions and are described below. The light levels 3 and 4 can be programmed by combining 2 addresses. With the second to last combination (only channel 5 active) the user switches the load OFF. The shown values are factory settings and are consequently protected against accidental resetting. evertheless, it is possible to disable the protection to change the default values. The following steps 1-4 explain how the protection can be disabled, the values changed, the protection reestablished and default settings restored. 1. Programming access (Unlock) a) When the output is OFF, keep the push button pressed for 10 seconds. b) When the green LED will be flashing the programming access is open. 2.ew light level a) Open for the programming access according to 1. Programming access. b)use address 1 to set the required light level. c) Activate, for approx. 3 seconds, the address to which the chosen light level is to be allocated. d)when the light starts dimming fast up to 100%, down to 5% and back to actual value, the new light level is stored. Undesirable changes of the programmed parameters can be avoided by re-establishment of the programming protection see 3. Protection. 3. Protection (Lock) a) When the output is OFF, keep the push button pressed for 10 seconds. When the green LED is always O, the programming access is closed. 4.Restoring of factory settings a) Open for the programming access according to 1. Programming access. b)activate address 1, 2 and 3 for approx. 9 seconds. c) When the light starts dimming fast up to 100%, down to 5% and back to the actual value, the factory settings are restored. When the factory settings are restored the programming protection is not active. Channel 6 programming According to the LED lamps used, the right curve has to be selected following the table LED curve selection. If a resistive, inductive or capacitive load is used, channel 6 must not be programmed. Advanced settings A switch off function has been added on channel 5, so that the dimmer can be switched off directly from the master function without using logic programming in the controller. In addition, the ramp time (soft start/stop and dimming speed) has been made adjustable, so that each of these two functions can be set to four additional ramp times (apart from the default times). This can be done individually for each type of ramp. If other ramp times are desired, these are set by means of the channels 7 and 8 (See tables below). Soft start/stop Ch.7 0-100% (seconds) - 2 P1 4 (standard) P2 8 P3 16 P4 32 Dimming Ch.8 0-100% (seconds) - 1.8 (standard) P1 3.6 P2 7.2 P3 14.4 P4 26.7 This means that if a start/stop ramp time of 8 secs is desired, then channel 7 is set to P2. The Channel programming addresses P1-P4 can, of course, be used for any other purpose, since they are only used to state ramp times. Hardware short circuit protection As described in the Lighting Circuit Design, if more capacitive transformers have to be connected in parallel for a total load higher than 180W @20, the hardware short circuit protection has to be disabled. To disable this protection, keep the pushbutton pressed during the power up of the dimmer: after two seconds the green LED will start blinking according to what is described in paragraph LED indications. If the hardware short circuit protection is enabled, it is always active when the output is both on and off. If the protection is disabled, it is active only when the load is off, in this situation care have to be taken to avoid short circuits when the output is active, otherwise the dimmer will be damaged. Channel combination Activation 1 2 3 5 Short Long O/OFF Dimming UP/DOW, 5%..100% Light scene #1 (40%) Store light scene #1 Light scene #2 (80%) Store light scene #2 Light scene #3 (20%) Store light scene #3 Light scene #4 (60%) Store light scene #4 100% OFF (*)Factory settings 0% / OFF (0%) OFF Set light scene back to factory settings Specifications are subject to change without notice (27.06.12) 3

LED Lamp Dimming When using the SH2D500W230 dimmer with LED lamps, channel 6 needs to be programmed with address P1 when the LED manufacture recommends trailing edge dimming (capacitive) or P2 when the LED manufacturer recommends leading edge dimming (inductive). The selection of P1 or P2 also implements a different response curve. This curve is the relationship between lamp brightness and the power supplied to it. LED lamps have a different curve compared to standard inductive loads. If channel 6 is given a blank address, automatic load detection and the standard curve are restored. Please see table here for manufacturer s recommendation. If your LED lamp is not listed, please refer to the manufacturer for advice on their preference for leading or trailing edge dimming. If many LED lamps are connected in parallel, we suggest the following rule to define the maximum number of LED lamps, the maximum total LED lamp power 1/10th of dimmer s maximum rated power. The maximum load depends on the capacitive input impedence of the LED lamps, so it can vary according to the LED lamps type. If the red LED on the SH2D500W230 dimmer starts blinking continuously as soon as the load is applied, this suggests that the total load has become more capacitive than inductive (the total capacitance is done by the sum of the capacitance of each connected LED lamp) and can not be driven anymore by setting channel 6 to P2. The explanation of this is as follows, as previously described most LED lamps have to be dimmed as an inductive load with leading edge dimming (P2), but if more LED lamps are connected in parallel, the load becomes more capacitive (total capacitance is the sum of capacitance for each connected). Since a capacitive load can not be dimmed with leading edge dimming (because of the currents peaks) channel 6 has to be set trailing edge dimming (P1). In this situation the dimming performance may be reduced. A compromise between dimming performance and the total load that can be connected has to be decided by the installer. LED curve selection www.productselection.net/manuals/uk/led_curve_selection.pdf LEDs Indication Red LED: Always O: Load O, no error - 1 short blink every 4 seconds: High current warning (> 2.5A). The dimmer goes on working but high temperature might occur. This depends on the time the output stays on and on the room temperature. - 2 short blinks every 4 seconds: Overvoltage error. To reset it, switch the dimmer OFF. If the error appears again, the load must be modified. - 3 short blinks every 4 seconds: High temperature error: this error will be triggered if the internal temperature raises above 90 C. Please wait until the inside temperature goes below 70 C. The reset of the error is automatic once the temperature is within operating range. - 4 short blinks every 4 seconds: Wrong frequency error. If the frequency of the power supply is correct, this error indicates a hardware failure. The reset of the error is automatic once the frequency is ok. - 5 short blinks every 4 seconds: Short circuit software protection active. As soon as the dimmer detects the short circuit, it starts counting a timeout of 30 seconds during which you have to wait. Once this timeout is elapsed, the green LED blinks synchronously with the red one: at this point, reset the error by removing the short circuit and press the push button on the dimmer. If the error is still present, the above procedure should be repeated. Always blinking: Hardware short circuit protection active. To reset it, switch the dimmer OFF, remove the short circuit and switch the dimmer O again. Green LED: Always O: Hardware short circuit protection active, lock condition - 1 short blink every 2 seconds: Hardware short circuit protection disabled, lock condition - 2 short blinks every 2 seconds: Hardware short circuit protection disabled, unlock condition - 3 short blinks every 2 seconds: Hardware short circuit protection enabled, unlock condition - 5 short blinks every 4 seconds: software short circuit protection active (this visualization overwrites the previous ones). Yellow LED: if the Dupline Bus is working properly, it is always O. If there is a fault on the Bus it will be flashing. It is OFF if the Bus is OFF or not connected. 4 Specifications are subject to change without notice (27.06.12)

Lighting Circuit Design Some general rules have to be taken into consideration when designing lighting circuits. Ferromagnetic transformers: When using halogen lighting with ferromagnetic transformers, pay attention to the output of the transformers. To maximise efficiency, load these transformers with at least 80% of their normal power. Pay attention to the output of the transformer when determining the total load of the dimmer. The transformer has to be suitable for dimming. Electronic transformers: Electronic transformers present a capacitive load to the dimmer but if the cable between the transformer and the dimmer is significant this will introduce an additional inductive load, and the dimmer would see a combination of the two types of load (inductive and capacitive). It is recommended that an electronic transformer is loaded to at least 75% of it s maximum rated loading, this reduces the possibility of lamp flicker when dimming, as is common with electronic transformers. Refer to the manufacturer s specifications for the electronic transformer being used. Pay attention to the output of the transformer when determining the total load of the dimmer (average efficiently is around 90%). The transformer has to be suitable for dimming. When a capacitive load is initially connected there may be a substantial surge of current through the primary winding called the inrush current. This inrush current may last for 2-3 seconds and can have a peak of 10 times the RMS current stated by the manufacturer of the transformer (this is also valid for CFL fittings). If many electronic transformers are connected in parallel, the value of the total current is given by the sum of the current peaks generated by each transformer. If the total inrush current is higher than 3.5 A, the dimmer s hardware short circuit protection will be activated. As a general rule if the short circuit protection is enabled, a total load of 30% of the nominal dimmer output power can be connected to the dimmer (180W@20 C). If the short circuit protection is disabled, a total load of 90% of the nominal dimmer output power can be connected (540W@20 C). Derating Curve Specifications are subject to change without notice (27.06.12) 5

SH2D500W230 Wiring Diagrams 1-phase load To other Dupline devices 3-phase load To other Dupline devices O SH2D500W O O O O O L L L L L L L L L L L L L L1 L2 L3 Dimensions 35 35 44,0 14,5 90,0 45,0 5 5 90,0 45,0 T O O UWP -DIM SH2D500W O L L 14,5 44,0 6 Specifications are subject to change without notice (27.06.12)