Ⅱ Ⅱ IP67
SPECIFICATION MODEL OUTPUT INPUT PROTECTION OTHERS NOTE DC VOLTAGE RATED CURRENT RATED POWER 12V 7.A 90W 24V 3.7A 90W 36V 2.A 90W 48V 1.88A 90.24W DIMMING RANGE 0 ~ 100% PWM FREQUENCY (Typ.) 300Hz VOLTAGE TOLERANCE ±4.0% ±3.0% ±2.0% ±1.0% SETUP, RISE TIME Note.2 00ms, 80ms 11VAC / 230VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 16ms/11VAC at full load VOLTAGE RANGE 90 ~ 30VAC 127 ~ 431VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.98/11VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) TOTAL HARMONIC DISTORTION THD< 20% when output loading 60% at 11VAC/230VAC input and output loading 7% at 277VAC input EFFICIENCY (Typ.) 88% 90.% 90.% 90.% AC CURRENT (Typ.) 0.9A / 11VAC 0.A / 230VAC 0.4A / 277VAC INRUSH CURRENT (Typ.) COLD START 60A(twidth=0 μs measured at 0% Ipeak) at 230VAC LEAKAGE CURRENT OVER LOAD SHORT CIRCUIT OVER VOLTAGE OVER TEMPERATURE <0.2mA / 277VAC 108 ~ 120% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 1 ~ 17V 28 ~ 34V 41 ~ 46V 4 ~ 60V Protection type : Shut down o/p voltage, repower on to recover Shut down o/p voltage, repower on to recover WORKING TEMP. 40 ~ 70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 9% RH noncondensing ENVIRONMENT STORAGE TEMP., HUMIDITY 40 ~ 80, 10 ~ 9% RH TEMP. COEFFICIENT ± 0.03%/ (0 ~ 0 ) VIBRATION 10 ~ 00Hz, G 12min./1cycle, period for 72min. each along X, Y, Z axes UL870, CSA C22.2 No. 20. 1312, ENEC EN613471, EN61347213, EN62384 independent, IP67 approved ; SAFETY STANDARDS Design refer to EN60331 SAFETY & EMC MAX. NO. of PSUs on 16A CIRCUIT BREAKER WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY PWM9012 PWM9024 PWM9036 PWM9048 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC I/PO/P:3.7KVAC I/PO/P:100M Ohms / 00VDC / 2 / 70% RH Compliance to EN01, EN6100032 Class C ( 60% load) ; EN6100033 Compliance to EN6100042,3,4,,6,8,11; EN6147, light industry level(surge L N : 2KV), criteria A MTBF 224.2K hrs min. MILHDBK217F (2 ) DIMENSION 171*63*37.mm (L*W*H) PACKING 0.77Kg; 18pcs/14.9Kg/0.82CUFT File Name:PWM90SPEC 2011017
Block Diagram PFC fosc : 0~120KHz PWM fosc : 60~130KHz I/P EMI FILTER & RECTIFIERS PFC CIRCUIT O.T.P. O.L.P. POWER SWITCHING PWM & PFC CONTROL RECTIFIERS V & DIMMING V FILTER CIRCUIT O.L.P. DIM DIM DETECTION CIRCUIT O.V.P. Derating Curve Static Characteristics 100 100 90 LOAD (%) 80 60 0 40 20 230VAC Input only LOAD (%) 80 70 60 0 40 40 2 10 0 1 30 0 60 70 AMBIENT TEMPERATURE ( ) (HORIZONTAL) 90 100 12 13 14 1 16 17 180 200 230 30 INPUT VOLTAGE (V) 60Hz Power Factor Characteristic PF Constant Voltage Mode 1.00 0.90 0.80 0.70 0.60 0.0 0.40 0.30 0.20 0.10 0.00 10% 20% 30% 40% 0% 60% 70% 80% 90% 100% (90W) LOAD 277V 230V 11V File Name:PWM90SPEC 2011017
EFFICIENCY vs LOAD (48V Model) PWM90 series possess superior working efficiency that up to 90.% can be reached in field applications. EFFICIENCY (%) 94 92 90 88 86 84 82 80 78 76 10% 20% 30% 40% 0% 60% 70% 80% 90% 100% LOAD 277V 230V 11V DIMMING OPERATION The PWM style output is a simple switching of supply ON/OFF at a rate so fast that the human eye cannot see led flickering. Duty cycle describes the proportion of time when output voltage is on relative to the entire period of time. It is expressed in percentage, 100% being fully on (maximal brightness) and a low duty cycle corresponding to lower brightness. Builtin 3 in 1 dimming function. The duty of the PWM style output can be adjusted through output cable by connecting a 0~10Vdc or 10V PWM signal or resistance between DIM and DIM. Connection V LED Strips V DIM 0~10Vdc or 10V PWM or resistance control dimmer DIM DO NOT connect "DIM to V" File Name:PWM90SPEC 2011017
Duty cycle of output current VS Dimming input Duty cycle of output current 100% 90% 80% 70% 60% 0% 40% 30% 20% PWM Style Output Output DC current ON TON T OFF 100% when DIM/DIM are open circuit. 10% Note 0% 0V 1V 2V 3V 4V V 6V 7V 8V 9V 10V 0~10V 0% 10% 20% 30% 40% 0% 60% 70% 80% 90% 100% Short 10K/N 20K/N 30K/N 40K/N 0K/N 60K/N 70K/N 80K/N 90K/N 100K/N Duty cycle of 10V PWM (frequency range = 100~3KHz) Short~100K Ω/N resistance (N=driver quantity for synchronized Dimming input dimming operation ) TON Duty cycle(%) = 100% T Output PWM frequency : 300Hz fixed (Typ.) Mechanical Specification AC/L(Brown) AC/N(Blue) T case: Max. Case Temperature. Case No. PWM90P 300± 20 300± 20 SJTW 18AWG 2C UL2464 18AWG 2C SJTW 16AWG 2C Unit:mm 37. Note : 1. Min. dimming level is about 6% 2. The output current is not defined when 0%< Iout<6% 3. The output current could drop down to 0% when dimming input is about 0KΩor 0Vdc, or 10V PWM signal with 0% duty cycle 63 2 ψ 4. 31. 171 8. DIM(Blue) DIM(White) V(Red) V(Black) Recommend Mounting Direction File Name:PWM90SPEC 2011017
Installation Manual Connection AC/L(BROWN) AC/N(BLUE) DIM(WHITE) DIM(BLUE) V(BLACK) V(RED) 0~10Vdc or 10V PWM or resistance Dimmer LED Strip Cautions Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure that it cannot be reconnected inadvertently! Keep proper ventilation around the unit and do not stack any object on it. Also a 101 cm clearance must be kept when the adjacent device is a heat source. Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a derating in output current. Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its specification. For LED power supplies with waterproof connectors, verify that the linkage between the unit and the lighting fixture is tight so that water cannot intrude into the system. For dimmable LED power supplies, make sure that your dimming controller is capable of driving these units.pwm series require 0.1mA each unit. Tc max. is identified on the product label. Please make sure that temperature of Tc point will not exceed limit. DO NOT connect "DIM to V". Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must requalify EMC Directive on the complete installation again. For more information about installation, please refer to www.meanwell.com/webnet/search/installationsearch.html for details. File Name:PWM90SPEC 2011017