audionet amp II G2 Owner's Manual Mono - Amplifier

Similar documents
audionet 4 Channel Amplifier Owner's Manual

audionet AMP 1 V2 User s Manual Stereo - Amplifier

audionet PAM G2 User s Manual Phono Preamplifier for MC / MM

FM / AM - Stereo Tuner. User's Manual

audionet PAM G2 & EPC User's Manual Phono Preamplifier & External Power Controller

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

Amplifier Series BASIC. Installation & Operations Manual

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide

M-300 Mono power amplifier User s guide

Boulder W Class A Stereo Power Amplifier

POWER AMPLIFIER. Owner s Manual POWER AMPLIFIER R 20 CLIP POWER TEMP PROTECTION 6 POWER. Keep This Manual For Future Reference.

Hegel H2A High End Power Amplifier

Boulder W Mono Power Amplifier

TSA 4-700, TSA 1400, TSA 2200, TSA 4000, TSA 4-300, TSA power amplifier. user manual

D3400 digital power amplifier. user manual

AELIUS YPSILON POWER AMPLIFIER. OWNERS MANUAL V1 01/01/20010 All rights reserved

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

Q44/Q66 PROFESSIONAL AMPLIFIER OWNER S MANUAL

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

USER MANUAL. GOLDMUND TELOS 2500 NextGen Universal Power Amplifier

PROFESSIONAL POWER AMP

MODEL 3 MONO AMPLIFIER OWNER S MANUAL

OWNER S MANUAL CPS 3 / CPS 4 CONTRACTOR PRECISION SERIES

E-400 power amplifier. user manual

E-800 power amplifier. user manual

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

M 10 Mono Power Amplifier

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

Primare A32 Amplifier User Guide

3050 Stereo Power Amplifier

High Efficiency Power Amplifier Module

E-800 power amplifier. user manual

PHIL JONES BASS PJB BP-800

1160 Stereo Power Amplifier

E4-130, E4-250 power amplifier. user manual

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

MC2301. Features and Benefits. Promotional Highlights TUBE POWER AMPLIFIER MCINTOSH LABORATORY INC., 2 CHAMBERS STREET, BINGHAMTON, NEW YORK 13903

ASR Emitter II und Emitter II Exclusive

EPA152/252/502. User Manual.

Owner s Manual. MOON Series. Titan HT-200. Multi-Channel Power Amplifier

Registration 3. Owners Record Setup 4. Unit Connections 6. Front Panel Controls 8. Remote Control 9. Unit Care Technology 10. Designer s Note 12.

USER MANUAL GOLDMUND TELOS 600 Universal Power Amplifier

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

TSA 4-700, TSA 1400, TSA 2200, TSA 4000, TSA 4-300, TSA power amplifier. user manual

AX6220Z/AX6240Z. Energy-Efficient, DSP-Powered and Ethernet/USB-Controlled 1000/900-Watt 70/100 V High-Impedance Power Amplifier.

i3speakers LX503 MK2 User Manual

TOA PROFESSIONAL POWER AMP

F O R T H E L O V E O F M U S I C LP100 OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION

Audionet PRE I G3: A wide grin at the press of a button.

SOUNDMASTER VF 400 MOS-FET POWER AMPLIFIER OWNERS MANUAL

ECI 6D. Balanced Integrated Amplifier. Owner's Manual. (with a built-in DAC) ENGLISH

EPA104/254. User Manual.

PST 100 YPSILON PRE AMPLIFIER MKII. OWNERS MANUAL V2 01/01/2010 All rights reserved

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

USER MANUAL GOLDMUND MIMESIS 29M Millennium Edition Power Amplifier

2BSST POWER AMPLIFIER OWNER S MANUAL

Primare A31.2 Amplifier User Guide

XES-M50 Operating Instructions

SA 125 mixer amplifier. user manual

User Manual. ilive 2 Wireless microphone system

PB 700 PB 1000 PB 1100 PB 1500 PB 2600 PB 1200 PB 1700 PB 2200 PB 2700 USER'S MANUAL.

Owner s manual. SDA 2175 Semi Digital Amplifier

USER MANUAL. GOLDMUND TELOS 1000 Universal Power Amplifier

BRIDGEABLE MOSFET POWER AMPLIFIERS BZA-2290/BZA-2390 BZA-2490/BZA-4190 OWNER'S MANUAL

REVAMP2600 Instruction manual

AC/DC Resistance Standard DRR-112

USER MANUAL. GOLDMUND TELOS Universal Power Amplifier

A hi-fi system begins with the source and ends with the loudspeakers.

G Series Power Amplifier User Guide

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

SLP-2002 Stereo Balanced Vacuum Tube Preamplifier

Nº32 REFERENCE PREAMPLIFIER

Dodecahedron Speaker Set

Kaskode One Phono Preamplifier Owner s Manual

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

plifier D-501 otion Am Tactile M

CALRAD 25 series - potentiometers

ZOTL40 Mk.II POWER AMPLIFIER USER GUIDE. Linear Tube Audio Takoma Park, MD, USA

Owners Manual. Single Coupled Multi Purpose Professional Subwoofer. www. artcoustic.com

A Series Professional Power Amplifiers

PL 15 Sub A active subwoofer. user manual

JEFF ROWLAND D E S I G N G R O U P

HBAC-20 guitar combo. user manual

Block-800B bass head. user manual

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

PA 502 A active 2-wayfull-range-speaker. user manual

870A Evolution Series

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

Monolith. Subwoofer System OWNERS MANUAL

MANUAL. Champ - One. Audiophile Stereo Power Amplifier

FEATURES FRONT PANEL. INPUT : Use this jack to connect your instrument via a standard ¼ mono cable.

DD1-1300S. 500 Watts RMS Watts RMS Watts RMS- 1. Mono-Bloc Digital Power Amplifier

USER MANUAL. GOLDMUND SR150 2-CHANNEL Universal Power Amplifier

User Manual VOLUME PTT 1 MIC/LINE 2 MIC/LINE 3 MIC/LINE 4 MIC/LINE 5 MIC/LINE 6 MIC/LINE 7 MIC/LINE 8 MIC/LINE 9 MIC/LINE 10 LEVEL LEVEL TREBLE 6 MIC

D4-500 digital power amplifier. user manual

FEATURES FRONT PANEL. INPUT : Use this jack to connect your instrument via a standard ¼ mono cable.

441 DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER 451 SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER

Primare A33.2 Amplifier User Guide

Transcription:

audionet amp II G2 Mono - Amplifier Owner's Manual

Owner's manual The Audionet-Team would like to congratulate you to purchasing the Audionet AMP II G2! Your Audionet AMP II G2 is designed for absolutely natural music reproduction at highest user comfort embedding total system security. Please read this manual before first use to make sure that you are able to use all provided functions of your new amplifier. In case of occuring questions please do not hesitate to contact your local Audionet dealer or our factory directly. 2

Setting up your system Placing Your Audionet AMP II G2 have the perfect dimensions to be placed near your speakers. But positioned side by side both AMP II G2 are 43 cm in width (standard width). Do not cover the top to prevent the amplifiers from overheating! Power connections Please connect the power jack at the rear to your wall outlet using a suitable power cord. Using high quality power cords may increase sound quality. Please consult you local Audionet dealer. The voltage specified at the rear of your AMP II G2 must match your mains specifications. The AMP II G2 is a Class I unit and has to be earthed. Mains phase recognition The correct polarization of mains is important for reasons of audio clarity and stability. Please make sure that the pin labled "Phase" at your APC is connected to the "hot" pin of your wall outlet. The Audionet AMP II G2 indicates a wrong polarization of the mains lead. If you read: Attention: Mains Phase incorrect when powering up, switch off the AMP II G2 and flip the plug in your wall outlet. 3

Inputs and outputs For connecting or removing any units the AMP II G2 must be switched off. Please make sure that all cables are in absolute best condition. Broken shields or short-cut loudspeaker cables could damage loudspeakers or the amplifiers! Inputs At first please connect your pre amplifier to the inputs of your AMP II G2. For audio input you can use balanced (XLR) as well as unbalanced (cinch) cables. For connections longer than 10 m we recommend balanced cables. Please don't forget to activate the selected input in the set menu. Speakers Now connect your speakers to one pair of the gold plated output jacks of your AMP II G2. You may use pure wires or "banana" plugs. Check the polarization of the speakers cables: Usually the speaker jacks are labeled "+" and "-". You will find the same label at your AMP II G2. Wrong polarization will lead to severe loss of sound quality! The speaker impedance must not be less than 2Ω! Though your AMP II G2 is effectively protected against shorted speaker jacks it has to be switched off while working on speakers and speaker cables! Bi-Wiring Your Audionet AMP II G2 supports bi-wiring of loudspeakers. Connect your speaker with two separate cables to each AMP II G2. Using the biwiring method to connect your speakers can lead to enhanced sound quality. 4

Operating Switching on Switch on your AMP II G2 at the rear side. The switch is above the mains socket. After some short time the line Audionet will appear in the display. Now your AMP II G2 is in stand by mode. For switching on and off please press the power button at the front of the AMP II G2. The main switch at the back is only to be used if you are absent for a longer time. It must only be operated while the AMP II G2 is in stand by mode Remote power on Your mono amplifiers AMP II G2 can both be switched on remotely by several different ways: using "Audionet Link": You can switch on or off your AMP II G2 with your Audionet pre amplifier PRE G2, PRE I G2, MAP or MAP 1, using automatic detection of an input signal: "Auto On/Off", using a countdown of specified time. (If the unit is in stand by mode you enter the corresponding menu by pressing the button at the front for longer than 2 seconds.) Audionet Link For a remote controlled switching on by your Audionet pre amplifier two simple optical "Toslink" cables are necessary. Connect the output labeled "audionet link" at your pre amplifier with the "audionet link" input of the first AMP II G2. Then connect the "audionet link" output with the second optical cable to the "audionet link" input of the second AMP II G2 Auto On/Off The AMP II G2 is equipped with a multi-stage input signal detection circuit. If an input signal is detected at the input (XLR or cinch) crossing the user definable threshold your AMP II G2 will switch on automatically. Due to the nature of stereo signals it may occur that both AMP II G2 will switch on at different points of time. The amplifiers will function as usual. Of course you still be able to switch on and off the units manually. 5

The amplifiers will shut down automatically when no input signal is detected for a user definable time (30 seconds up to 2 hours). To activate and setup this feature please refer to chapter "Programming". Due to security concerns the "Auto-On" feature will only be available after first manual switching on! "Warm Up" Countdown While you are absent your AMP II G2 can switch on automatically and will be pre-heated for use when you get back. To activate this feature please use a long key press on the "power" button at the front. The display changes to show the countdown timer. A cursor will mark the number to be changed. A long key press will move the cursor one step to the right. Using a short key press you can change the desired number. Hours can be programmed in steps of one hour. Minutes can be programmed in steps of 15 min. The following diagram explains the possible countdown timer settings: 01 hour 15 min 01 hour 15 min 01 hour 15 min 11 hours 15 min 02 hours 15 min 01 hour 30 min 91 hours 15 min 00 hours 15 min 01 hour 00 min 10-hours-setting 1-hour-setting Min-setting Legend: long key press short key press Activate countdown by leaving the timer settings menu with a long key press. It will be activated automatically if you do not change any setting for longer than 10 seconds. If you want to use the countdown timer again it is activated by a single key press. Press the "power" button for more than 2 seconds and wait. After 10 seconds the previous set up countdown will start again. To deactive the countdown use a short key press at any time. 6

Protection system Your Audionet AMP II G2 and your loudspeakers are protected by a complex protection circuitry. The display will report in clear every detected error: Overload: Shorted loudspeaker cables or defective loudspeaker (your AMP II G2 is capable of driving even 1Ω loads) Temp Failure: Do not cover the ventilation slots HF-Failure: high frequency oscillation, e.g. defective pre amplifier DC-Failure: too high level of DC voltage at the output 7

Programming Overview Except the previous described feature of countdown timer controlled automatic power on your AMP II G2 can be setup to your preferences by menu selections. The settings will last after switching off the AMP II G2. Changing settings has to be done while the amplifier is switched on and in operating mode. List of settings to be adjusted to your preferences: Brightness of display (default: 50% brightness) Display mode: selected input, temperature, peak-level meter Input selection: Cinch or balanced (XLR) input Auto-On: threshold for level controlled automatic power on (see above) Auto-Off: time to automatic power down (see above) Choose between two texts to be displayed in stand by mode Operating To change settings use short or long key presses on the "power" button at the front of the AMP II G2. Switch on your AMP II G2 and hold the button pressed for at least 2 seconds to enter the menu. For further operating modes please consult graphic below. A long key press will enter a menu or sub-menu. Use short key pressings to move along the menu options. To save the changed settings use a long key press or wait for at least 10 seconds. For further changes to the settings re-enter the menu as described above. 8

Operating SET DIM 100% 80% 50% 25% Select display brightness (4 steps) *) SET DISPLAY STANDARD Standard display TEMPERATURE Temperature display PEAK-LEVEL Peak level meter SET INPUT CINCH Select cinch input BALANCED (XLR) Select balanced (XLR) input SET AUTO ON NEVER ON Never power on automatically FAST ON High sensitivity MEDIUM ON Medium sensitivity SLOW ON Maximum rudgeness SET AUTO OFF NEVER OFF Never power off automatically OFF IN 30 SECS OFF IN 5 MIN OFF IN 15 MIN When the music stops wait for the specified time until automatic power down OFF IN 60 MIN OFF IN 120 MIN SET OFF TEXT AUDIONET Select text to be displayed in stand by mode EXIT... Legend: long key press short key press *) WARNING: Long term usage of the display set to maximum brightness (setting 100%) may cause extended signs of wear resulting in a decay of contrast or brightness of individual dots in the display. Do not use the display with a brightness set higher than the factory default setting of 50% over a longer period of time 9

Technical information Construction The AMP II G2 is designed as a dual-mono amplifier. SMD techniques are used to optimize high-frequency characteristics. All signal paths are reduced to minimum length. No 'evil' elements (like coupling capacitors, coils, relays) are located in the signal path. The design is magnetically and capacitively optimized. Negative magnetic and electric influence and interaction between input, decoupling and power section are reduced to a residual minimum. Power supply Control, decoupling and power sections have separated transformers and rectifiers. The main transformer (850 VA) drives two high-current capacitors (80.000µF) especially manufactured for Audionet by Schottky diodes. Circuitry For the input section Audionet uses a low-noise, monolithic dual FET. The gain-bandwidth product of the succeeding dual-stage differential voltage amplifier exceeds 1 GHz. Input and output sections are decoupled using 'bootstrapped' emitter followers. The output section is equipped with power MOS-FETs. They can handle a pulse power up to 2.5 kw. The high bias current through that stage (0.4 Amperes) is regulated actively. Therefore, signals at normal volume level are handled in pure Class A mode. Peak level meter In order to determine the impulse peak level the AMP II G2 detects a voltage maximum and measures the current flowing at that point of time. By that impedance critical loudspeakers are processed automatically and according to that a higher peak level is displayed. You will get the exact effective power. If no loudspeaker connected only a small measuring error is displayed (e.g. 3.0W instead of 200W for a 4Ω-loudspeaker). The current number is displayed for about 2 seconds if not replaced by a higher peak level. 10

Security advice Avoid packaging material, especially plastic bags, to come into children s hands. Store and operate the unit in a dry room at a reasonable room temperature. Avoid moisture or any liquid to get into the unit. Set up the unit in a free position so that the air is allowed to flow through the unit slits. Do not cover, e.g. with a blanket. Do not open the case. Unauthorised opening will cause loss of guarantee. Use a dry cloth for cleaning. 11

Technical data Type Power Bridged operations Frequency response Damping factor Intermodulation THD Noise Inputs Output Mains Dimensions Weight Finish front Button Top Sides Chassis Microprocessor controlled power amplifier 200 Watt in 8Ω 350 Watt in 4Ω 550 Watt in 2Ω 750 Watt in 1Ω, all true RMS at 1% THD 1400 Watt in 4Ω, two AMP II G2 per channel 0-300.000Hz (-3dB) > 1.800 at 10kHz, (8Ω) > 10.000 at 100Hz, (8Ω) < -110dB SMPTE (100Hz:200kHz, 4:1), 50W/4Ω < -105dB at 1kHz, 35W/2Ω k2 typ. -117dB, k3 typ. -140dB, at 25W/4Ω > 110dB at 10V eff Cinch, WBT (gold plated): 37kΩ, 220pF XLR, Neutrik (gold plated): 3kΩ, 170pF (1: GND, 2: Pos, 3: Neg) 2 pair of gold plated WBT terminals 220..240 Volt / 50..60 Hz 5W Stand-By, 1000W max. 215mm x 190mm x 500mm (WxHxD) 22kg brushed Aluminum, 10mm (Front plate in alu nature or black availible) chrome or black brushed Aluminum, black, 6mm brushed Aluminium, black, 4mm Steel, black Engineered and produced by: Idektron GmbH & Co. KG, Herner Str. 299, Gebäude 6, 44809 Bochum www.audionet.de contact@audionet.de 12