CFMRI Mock Scanner User s Manual. (Last Updated 10/23/2014)

Similar documents
MRI SIMULATOR PST OPERATOR MANUAL

Fire CR Calibration Guide

Basic Recording. Start --> Programs --> Panopto --> Panopto Recorder. Logging In

Faculty Lecture Capture Guide

Your Visits to the Magnet Machine!

INSTALLATION HANDBOOK

PHYSICS 220 LAB #1: ONE-DIMENSIONAL MOTION

Logging into Five9 Telephony

Patient transport. D.1 Patient table D.1-1. Patient table positions Layout of coil sockets Connections at the patient table

Operating Rausch ScanCam within POSM.

Mobile Application Training

Table of Contents. Vizit s Carousel Menu Gallery Play Favorite Remove Rotate Fill Screen Friends Block Lock Screen Settings Reply Share

is designed from the ground up for an exceptional sensory experience for both YOU and YOUR patients.

The Eyetracker. Bruno Bonet

Operating Procedures for MICROCT1 Nikon XTH 225 ST

Operating Checklist for using the Scanning Electron Microscope, JEOL JSM 6400.

Learning to use your easypod. [somatropin (rdna origin) for injection]

Sony Soloist will allow you to do all of these same operations digitally, that is to say, on a computer & without a cassette!

How to: Make a room booking

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

DRCR.net Image Acquisition Protocol

IDEXX-PACS * 4.0. Imaging Software. Quick Reference Guide

Reviewing Your Tax Return In Your Portal

S! Applications & Widgets

Doc #: 2100 AD Revision: MOSAIC Removal Procedure. Author(s): Hillary Mathis, Bill McCollam

Shadowtracker User Manual

After completing this lesson, you will be able to:

Panorama TELEPACK 608

PCM MIDMARK ECG ACQUISITION MODULE As of PCM to be used with Midmark Controls.msi

FEI Quanta 200 ESEM Basic instructions

How to Pair AbiBird Sensor with App and Account

3D Capture. Using Fujifilm 3D Camera. Copyright Apis Footwear

MIX SUITE + VOCAL BOOTH BASICS

1.1. Log on to the TUMI system (you cannot proceed further until this is done).

Progeny Imaging. User Guide V x and Higher. Part Number: ECN: P1808 REV. F

KM-4800w. Copy/Scan Operation Manual

Figure 1 The Raith 150 TWO

4.0 How to Turn On the Selenia Dimensions

LSM 510 Training Notes

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

P2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT

Apple Photos Quick Start Guide

Scorer with BridgePads Quick Guide to Teams Scoring

3D Capture. Using Fujifilm 3D Camera. Copyright Apis Footwear

Printing for Professionals

Progeny Imaging Veterinary

R PROFLAME Instruction Book Collection

RDworks and Basic Rabbit Laser Operation Tutorial

Guidelines to Using a Three Phase Voltage Monitor

Olympus LEXT OLS 4000 Confocal Laser Microscope

INTRODUCTION TO DATA STUDIO

Olympus Digital Microscope Camera (DP70) checklist

Live Agent for Support Supervisors

Online Check-in Information for 2018 Sunnyvale Alliance Medina Fall Classic

Digital Storytelling...a powerful tool!

General Help. Last revised: Winter When I try to print something on the computer, it appears to work, but nothing comes out of the printer.

HAAS LATHE PANEL TUTORIAL

Running the PR2. Chapter Getting set up Out of the box Batteries and power

MAKING THE FAN HOUSING

Office of Physical Resources & Planning

Kobra Manual. Forsslund Systems

Nikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol

Create a Simple Architectural Structure (Architectural CAD)

2012 Monitored Rehab Systems E1201 Manual Kneelax. Installation and user manual

Davis Art Images: Create and Share Slideshows

Photo Story Tutorial

1.3 Using Your BoXZY

Live Agent for Support Supervisors

Assessment: Reverse Engineering

Minolta Scanner Plugin

Widefield 1. Switching on

WELCOME TO BINGO CALLER

Prezi : Software redefining how Presentations are created.

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

Omniverse Setup Instructions

Welcome to Weebly. Setting up Your Website. Write your username here:

Live Agent for Support Supervisors

Zeiss Deconvolution Microscope: A Quick Guide

LSM 510 Meta Training Notes

PERSONAL RECORD KEEPING

Exercise 2-2. Four-Wire Transmitter (Optional) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Ultrasonic level transmitter DISCUSSION

Intro to 3D Printing. Anatomy of the Printer. Intro to 3D Printing & Certification imagine create learn grow

ADVANCED USER S GUIDE

Thanks for shopping with Improvements! Mandarin Tansu Step Cabinet Item #512735

С 800 CASSIDA C 800 HIGH SPEED COIN COUNTER

Magnetic Resonance Research Facility (MRRF) Resources

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).

Warehouse Instruction Guide

SCHLAGE SENSE. Smart Deadbolt. Installation Instructions. Download the Schlage Sense app to get started!

An Introduction to Programming using the NXT Robot:

Standard Operating Procedure (SOP) for Shared Equipment: Spinning Disk Confocal Microscope

Inventory Manual. Version 3. Hart ID = Have a question? Call Hart Client Care at , or us at

Title: Forces, Friction and Motion

Network Scanner Guide for Fiery S300 50C-KM

reference guide reference guide reference guide

Standard Operating Procedure

Nikon D7100 Camera Kit. -Checklist and Operations Manual-

Air Navigation Race Scoring & Visualisation Software

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10

ThermaSkirt User Manual

Transcription:

CFMRI Mock Scanner User s Manual (Last Updated 10/23/2014) Page 1 of 6 CFMRI 2014

UCSD Center for functional MRI (CFMRI) provides a mock Scanner that simulates the look and feel of a real MRI scanner. The mock scanner allows research subjects to be prepared for functional MRI scans prior to going into the real MRI scanner, increasing the rate of successful data acquisition and the quality of fmri data. The mock scanner also helps scan operators to become familiar with setting up for running a study at the 3T scanners. This manual contains basic instructions on how to operate the mock scanner. Please note that this manual does not replace the hands-on training which is mandatory for all mock scanner operators. Step by-step Instructions 1. Turn on the POWER. a. POWER switch (switch on the right) controls power to all the electronics including the patient table electronic foot pedal, fans, motion tracking device, patient alarm, and the video projector. b. You may selectively turn on/off the in-bore fan using the switch labeled FAN. c. The middle switch powers the motion tracking device. If you don t plan on using the motion tracking device for your session, leave this switch at off position. N.B. This switch must be turned on before opening the motion tracking program on the desktop computer to avoid software error. If you get an error message saying MoTrak Console not connected, please turn off the program, power on the switch, then restart the program. 2. Position subject on the table. a. Make sure that the patient table is fully out from the bore. b. Lower the table using the foot pedal near the floor. c. Remove the top of the bird cage coil using the two release buttons on the side of the bird cage. d. Ask the subject to lie down on the table and center the head in the bird cage coil. e. Put on headphones if desired. Disposable headphone covers and ear plus are available in the storage cabinet above the desktop computer. f. Attach motion sensor if motion tracking is desired (see details in the notes below). g. Place top half of the bird cage back on. h. Use pads to help keep subject s head in place. Page 2 of 6 CFMRI 2014

i. Raise the table using the electronic foot pedal. j. Provide the patient alarm ball to the subject to hold in his/her hand. k. Turn the release handle bar at the end of the table to unlock the table and push subject/table to the isocenter of the bore. Once the table is at the isocenter the lock will automatically engage to prevent further moving of the table. To take the subject/table out turn the release handle bar and pull. Release handle Notes: Attach the motion sensor a. The motion tracking sensor should be put on before the subject lies down on the table. b. Sensor should be placed in the center of the forehead using the supplied head band. Adjust the head band for a good fit. The wire coming out of the sensor should be pointing towards the bore and away from the subject. 3. Turn projector on if desired. a. Use the projector remote to turn on the projector. b. Pull down the screen. c. Ask the subject to adjust the mirror on top of the coil for a clear and unobstructed view of the screen. 4. Login to the computer. a. Password is posted on the LCD screen. b. Load Scanner Sound Simulator software for recorded MRI sound effects (See Scanner Simulator section below). c. Load MoTrak for motion tracking (see MoTrak section below). 5. End the session. a. Bring the table/subject fully out. b. Turn off the projector (press the power button on the remote twice while pointing it at the projector) and retract the screen. c. Turn off the main POWER. d. Log out on the computer. e. Put back pads, motion sensor, head phones etc, and put used sheets in the laundry basket. f. Clean up any mess. g. Lock the door behind you. Page 3 of 6 CFMRI 2014

Scanner Sound Simulator Scanner Sound Simulator is a software program that plays recorded sounds of MRI scans. 1. Load the Mock Scanner Sound Simulator 2.0 from the desktop. 2. Select the type the scan for the sound you would like to play. a. The sound track will play immediately after you select a scan. b. The duration and current position of each sound track is displayed at the bottom of the window. c. The volume can be adjusted by using the sliding volume bar on the right side of the window. 3. To stop the sound push pause button or wait for the soundtrack to finish. Page 4 of 6 CFMRI 2014

MoTrak MoTrak is a motion tracking software that measures and displays a subject s head motion while the subject is lying in the mock scanner. The program can be used to help subjects practice staying still for the duration of the MRI scan. Basic Controls A. Save the current configuration and settings. B. Load a previously saved configuration. C. Start motion tracking. D. Reset the current cross hair position to zero. E. Go to full screen mode F. Open the options window. G. Select what is displayed to the subject on the screen (Target or Movie). H. Select what is displayed in the active target window (Angle or Position). Getting Started 1. Load MoTrak from the desktop. 2. Click on the Run button to start tracking and a data logging message will pop up. 3. Click on yes if you desire to record data to a file. 4. Click on the Center button to zero the cross hairs Target Options 1. Click on the Options Button. 2. The Options window should open up. 3. Click on the Target tab. 4. Target has two different sets of configuration, one for Position and one for Angle. 5. Make the desired changes to Sensitivity, Size Ratios and other options as desired. 6. Click on OK. Page 5 of 6 CFMRI 2014

Target Sensitivity In Position target mode, Sensitivity is in millimeters from center to the edge or the outer circle or radius of the circle. In Angle target mode, sensitivity is in rotation degrees from the center to the edge of the outer circle. Movie Display You can display a movie to the subject instead of the target. The movie will pause if the subject has moved out of the center target and will resume when the subject moves back. The program plays only movies in avi or mpeg formats and does not support any plugins. 1. Click on the Options button. 2. In the Movie Settings select your movie. 3. Click on OK. 4. Change the User Display window to Movie. 5. Click on Run and choose to save data if desired. 6. Click on play button on the lower left of the main window. Questions?? Please contact the Center by email: ddshin@ucsd.edu Page 6 of 6 CFMRI 2014