TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Similar documents
Temperature transmitter itemp PCP DIN rail TMT 121

Temperature head transmitter itemp PCP TMT 181

Technical Information itemp TMT180

itemp HART DIN rail TMT112

0 2 1 â Ó. itemp HART TMT182. Technical Information

Temperature head transmitter itemp PCP TMT 181

Temperature Transmitter itemp RTD DIN rail TMT 127

0 2 1 â Ó. itemp HART TMT182. Technical Information

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Temperature head transmitter itemp TC TMT 188

itemp PA TMT184 Technical information

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Temperature transmitter itemp RTD DIN rail TMT 127

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Temperature Transmitters - Head Mounted

Temperature Transmitters - DIN Rail Mounted

Miniature resistance thermometer Model TR33, thread-mounted

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Temperature transmitter with local display RIT 261

Temperature Transmitters TMT 136, TMT 137

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Technical Information Barrier RB223

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Resistance thermometer Model TR31, miniature design

Temperature measurement TMD 832 head transmitter

OPTITEMP TT 20 Technical Datasheet

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

Temperature Transmitters

for installation into terminal head form B and for installation on DIN rail Output signals : 4 to 20 ma : 4 to 20 ma 0 to 10 V

RMA42. Technical Information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Resistance thermometer Model TR30, compact design

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Resistance thermometer Model TR30, compact design

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Temperature Input Module for Zone 1 Series 9482/32

Assembly. Front view. Parametrization interface. Power Bus

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Isolators A3/1.

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Screw-in resistance thermometers with plug connector

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

4 Ó 5 â. Easytemp TMR31, TMR35. Technical information

High-precision process calibrator Model CED7000

Electronic Thermostat TE-1 Version according to EN

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

P5201 Universal Programmable Transmitters with Galvanic Isolation

Paperless Recorder PR20

Technical Information RMS621

E+H Model PT TMT184. Temperature head transmitter with PROFIBUS-PA -interface. Supply and digital communication using PROFIBUS-PA

Technical Information RMA42

Process display RIA 261

OPTITEMP TT 10 C/R Technical Datasheet

SITRANS T measuring instruments for temperature

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

SINEAX V 604s Programmable multifunctional transmitter

Indoor, outdoor and duct resistance thermometers

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Level Limit Switch nivotester FTL 325 P

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

TxBlock-USB Transmitter

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Temperature Measurement

Two-Wire Programmable Transmitter for:

Analog Universal Module HART for Zone 2 Series 9468/33

Temperature Measurement

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

prosonic T FMU230, FMU231

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Remote Switching Unit nivotester FTL 320

Digital indicator for panel mounting With multi-function input Model DI25

Transcription:

Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de TT2780 Data Sheet TT2780 Page 1/5 Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H Application area PC programmable (PCP) Temperature head transmitter for converting a Pt100 input signal into an scalable 4 to 20 ma analog output signal Input: Resistance thermometer Pt100 Online configuration using a PC with configuration kit Features and benefits Universal PC programmable for Pt100 input signal 2 wire technology, 4 to 20 ma analog output High accuracy in total ambient temperature range Fault signal on sensor break or short circuit, presettable to NAMUR NE43 EMC to IEC 61326-1, CE Online configuration during measurement using SETUP connector Customer specific measurement range setting 4 TI088R/09/en 51003515

Data Sheet TT2780 Page 2/5 Operation and system construction Measurement principle Measurement system Electronic measurement and conversion of Pt100 input signals in industrial temperature measurement. The TT2780 temperature head transmitter is a two wire transmitter with an analog output. It has measurement input for resistance thermometer Pt100 in 2-, 3- or 4-wire connection. Setting up of the TT2780 is done using the configuration kit. Input values Measurement value Measurement range Temperature Type Measurement ranges min. measurem. range Pt100 accord. to IEC 60751-200 to 650 C (-328 to 1202 F) -50 to 250 C (-58 to 482 F) Connection type: 2-, 3- or 4-wire connection cable resistance compensation possible in the 2-wire system (0 to 20 Ω) Sensor cable resistance: max. 11 Ω per cable Sensor current: 0.6 ma 10 K 10 K Output values Output signal Transmission behaviour Signal on alarm Load Input current required Current limit Switch on delay analog 4 to 20 ma, 20 to 4 ma temperature linear Measurement range undercut: Linear drop to 3.8 ma Exceeding measurement range: Linear rise to 20.5 ma Sensor breakage; Sensor short circuit: 3.6 ma or 21.0 ma (if setting 21.0 ma output 21.5 ma is guaranteed) max. (V power supply - 10 V) / 0.022 A (Current output) 3.5 ma 23 ma 4 s (during power up I a = 3.8 ma)

Data Sheet TT2780 Page 3/5 Auxiliary energy Electrical connection Head transmitter terminal connections Supply voltage U b = 10 to 35 V DC, polarity protected Residual ripple Allowable ripple U ss 3 V at U b 13 V, f max. = 1 khz Performance characteristics Response time 1 s Reference conditions Calibration temperature +25 C (77 F) ± 5 K (± 9 K) Maximum measured error Resistance thermometer (RTD) Type Pt100-200 to 650 C (-328 to 1202 F) Pt100 b -50 to 250 C (-58 to 482 F) Measurem. accuracy a 0.2 K or 0.08% 0.1 K or 0.08% a. % is related to the adjusted measurement range (the value to be applied is the greater one) b. as option Influence of power supply ± 0.01%/V deviation from 24 V 1 Influence of ambient temperature (temperature drift) Resistance thermometer (Pt100): T d = ± (15 ppm/k * (range end value + 200) + 50 ppm/k * preset meas. range) * Δ ϑ Δ ϑ = Deviation of the ambient temperature according to reference condition (+25 C (77 F) ± 5 K (± 9 K)). Long term stability 0.1K/Year 2 or 0.05%/Year 3 2 Influence of load ±0.02%/100 Ω 1 1. All data is related to a measurement end value. 2. according to reference conditions 3. % is related to the adjusted measurement range (the value to be applied is the greater one).

Data Sheet TT2780 Page 4/5 Installation Installation conditions Installation angle: No limit Installation area: Connection head accord. to DIN 43 729 Form B; TAF10 field housing Environment Ambient temperature range Storage temperature range Climate class Condensation Ingress protection Shock and vibration resistance Electromagnetic compatibility (EMC) 40 to +85 C (-40 to 185 F) -40 to +100 C (-40 to 212 F) according to IEC 60 654-1, Class C allowable IP 00, IP 54 (installed in sensor head) 4g / 2 to 150 Hz according to IEC 60 068-2-6 Interference immunity and interference emission according to IEC 61 326-1 Mechanical construction Design, dimensions Dimensions of the head transmitter in mm (inch) Weight Material Terminals approx. 40 g (1.41 oz) Housing: PC Potting: PUR Cable up to max. 1.75 mm 2 (AWG 16) - secure screws or 1.5 mm 2 (AWG 16) with wire end ferrules Human interface Remote operation Configuration Configuration kit, configurable on PC software programme Starting from version R2.00.00 of the TT2780 A the temperature head transmitter is configurable without voltage supply.

Data Sheet TT2780 Page 5/5 Ordering information How to order Head transmitter TT2780 PC programmable temperature transmitter, configurable measurement range for Pt100, analog output 4 to 20 ma, 2-wire technology, failure mode to NAMUR NE43, for mounting in Form B head to DIN 43729 Certification A Non-hazardous areas Programming 1 PC-programmable Max. range, accuracy 1-200 to 650 C (-328 to 1202 F), 0.08% of span or 0.2 K 2-50 to 250 C ( -58 to 482 F), 0.08% of span or 0.1 K Configuration transmitter connection 3 RTD 3-wire 4 RTD 4-wire 2 RTD 2-wire Configuration range AA 0 to 50 C (32 to 122 F) AB 0 to 100 C (32 to 212 F) AC 0 to 150 C (32 to 302 F) AD 0 to 250 C (32 to 482 F) AE 0 to 200 C (32 to 392 F) KA -40 to 140 F MB 0 to 200 F MC 0 to 300 F MD 0 to 500 F XX Customised range (min. span 10 K) Model A Standard model TT2780- Order-Code