Indoor, outdoor and duct resistance thermometers

Similar documents
Screw-in resistance thermometers with plug connector

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

Screw-in resistance thermometers with terminal head Form B

JUMO dtrans T03 J, B, T Analog 2-wire transmitter with digital adjustment. JUMO dtrans T03 BU, TU Analog 3-wire transmitter with digital adjustment

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Mineral-insulated resistance thermometers to EN

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Electronic Thermostat TE-1 Version according to EN

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

Resistance thermometers for process technology

Miniature resistance thermometer Model TR33, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR31, miniature design

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Analogue Temperature Transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

J IPC IGBT power converter

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Analog outputs (option) Outputs 1 + 2: 0(4) - 20 ma or 0-10 V

ecotrans Lf 01/02 Transmitter / Switching Device for Conductivity Type B Operating Instructions 02.07/

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Relative Humidity & Temperature Transmitters

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

dtrans Lf 01 µp transmitter / controller for electrolytic conductivity

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

JUMO Wtrans Receiver with Wireless Data Transmission

Technical Information itemp TMT180

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

P5201 Universal Programmable Transmitters with Galvanic Isolation

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

JUMO di 32 / di 08. Brief description. Block structure

Analog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

dtrans Az 01 µp Indicator/Controller for analytical measurement

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Inductive conductivity transmitter JUMO CTI-Junior

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

for installation into terminal head form B and for installation on DIN rail Output signals : 4 to 20 ma : 4 to 20 ma 0 to 10 V

Temperature Transmitters TMT 136, TMT 137

Resistance thermometer Model TR30, compact design

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Resistance thermometer Model TR30, compact design

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Operating instructions Measured signal converter for temperature sensors TP / / 2010

Temperature Measurement

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp PCP TMT 181

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

ph or ORP Transmitter

dtrans Rd 01 µp Transmitter / Controller for redox potential (ORP)

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

MODEL: M2DYS SEN TRONIC AG

Digital indicator for panel mounting With multi-function input Model DI25

Technical Information Barrier RB223

Temperature Measurement

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor for Build-In System G3/8" FLEXadapt

Pressure transmitter for general industrial applications Model A-10

0 2 1 â Ó. itemp HART TMT182. Technical Information

Temperature Transmitter itemp RTD DIN rail TMT 127

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Temperature sensor. Graphics LC display.

Resistance thermometer Model TR30, compact design

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Conductivity Transmitter

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

dtrans ph 01 µp Transmitter / Controller for ph or redox potential (ORP)

A new approach to static electricity countermeasures

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits

Digital flow ELEMENT transmitter for continuous flow measurement

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

JUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description.

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

20 General technical data XI/ON

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Transcription:

Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 1/6 Indoor, outdoor and duct resistance thermometers for temperatures from 30 to 80 C (200 C) for use in HVAC IP20 to IP65 protection for 2wire, 3wire or 4wire connections fitted transmitter option 4 20mA or 0 10V Indoor, outdoor and duct resistance thermometers for HVAC applications are mainly used for temperature measurement in rooms, air ducts and outdoors. Different instrument versions with plastic housings for different protection ratings are available to suit the particular measurement task. The measuring insert is normally fitted with a Pt100 temperature sensor to EN 60 751, Class B, in 2wire circuit. Versions with Pt500, Pt1000 or Ni 1000 can also be supplied. An extension in 3 or 4wire circuit, starting from the terminals, is possible. A transmitter can optionally be integrated. Technical data Terminal box Protection tube Measuring insert Transmitter plastic PC housing (material PP on Type 902523/11), IP20 to IP65, Type 902523/25: IP54 and IP65 protection stainless steel 1.4571; 5.4mm and 6mm dia. Pt100 temperature sensor, EN 60 751, Class B, 2wire circuit analog transmitter, output signal 4 20mA or 0 10V

Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 2/6 Transmitter Output 4 20mA Output 0 10V Input Measurement input Pt100 (EN 60 751) Sensor current 0.5mA Sampling rate continuous measurement because of analog signal path Measurement circuit monitoring Underrange falling to 3.6mA 0V Overrange 1. All data refer to the endofrange value 20mA. 2. The larger value applies. rising to 22mA to < 28mA (24mA typical) Connection example with supply unit, 4 20mA output Connection example with supply unit, 0 10V output rising to 11V to < 14V (12V typical) Probe short circuit 3.6mA 0V Probe and lead break 22mA to < 28mA (24mA typical) 11V to < 14V (12V typical) Output Output signal proportional DC current 4 20mA DC voltage 0 10V Transfer characteristic linear with temperature Transfer accuracy ±0.1% ±0.2% Damping of ripple on 37dB 40dB 24V supply voltage, amplitude 10V/50Hz, burden 470Ω/load 10MΩ Burden (Rb) Rb = (Ub 7.5V) / 22mA Burden error ±0.02% / 100Ω 1 Load/load error 10kΩ / ±0.1% Settling time on temperature change 10msec Calibration conditions 24V DC / approx. 22 C Calibration accuracy ±0.2% 1,2 or ±0.2 C Overall accuracy: sensor/calibration ±0.4 C (typical) at 20 C / 24V supply voltage Supply Supply voltage (Ub) 7.5 30V DC 15 30V DC Reverse polarity protection yes Supply voltage error ±0.01% per V deviation from 24V 1 Ambient conditions Operating temperature range 40 to 85 C Storage temperature range 40 to 100 C Temperature error ±0.01% per C deviation from 22 C 1 Climatic conditions similar to EN 60 654, Class C1 EMC interference emission/immunity relative humidity 95% annual mean, no condensation EN 61 326, Class B / to industrial requirements Controller Indicator 2wire transmitter Controller 4 20mA Indicator Supply unit 7.5 30V DC 3wire transmitter 0 10V Supply unit 15 30V DC N 0 10V L1 Connection diagram Output 4 20mA Output 0 10V Connection for Terminal Connection for Terminal 81 82 83 Supply voltage 7.5 30V DC Current output 4 20mA 81 82 R B = U b 7.5V 22mA R B = burden resistance U b = supply voltage 81 82 Supply voltage 15 30V DC Voltage output 0 10V 81 82 82 83 Load 10kΩ 81 82 83

Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 3/6 Dimensions Type 902523/10 Type 902523/11 Type 902523/12 Type 902523/13 Type 902523/20 Type 902523/25

Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 4/6 Order details: Indoor, outdoor and duct resistance thermometers (1) Basic version 902523/10 Indoor resistance thermometer, Protection IP20 902523/11 Indoor and outdoor resistance thermometer, Protection IP54 902523/12 902523/13 Indoor and outdoor resistance thermometer, Protection IP65 Indoor and outdoor resistance thermometer with stepped protection tube, Protection IP65 (2) Operating temperature in C x x 568 30 to 60 C (range only in conjunction with extra code 330 or 333) x x x 572 30 to 80 C (standard) x 635 20 to 80 C (standard) x x x 803 0 to 40 C (range only in conjunction with extra code 330 or 333) x x x 807 0 to 60 C (range only in conjunction with extra code 330 or 333) (3) Measuring insert x x 1001 1 x Pt100 in 3wire circuit x x x x 1003 1 x Pt100 in 2wire circuit x x x x 1005 1 x Pt1000 in 2wire circuit x x x x 1009 1 x Ni 1000 in 2wire circuit x 2001 2 x Pt100 in 3wire circuit x x x 2003 2 x Pt100 in 2wire circuit (4) Tolerance class to EN 60 751 x x x x 1 Class B (standard) x x 2 Class A (not for Type 902523/10 in conjuction with transmitter) x x 3 Class 1/3 DIN (not for Type 902523/10 in conjunction with transmitter) (5) Extra codes x x x x 000 no extra code x x x 330 analog transmitter, 4 20mA 2 output (in conjunction with 1 x Pt100) x x x 333 analog transmitter, 0 10V 2 output (in conjunction with 1 x Pt100) (1) (2) (3) (4) (5) Order code /,... Order example 902523/10 572 1001 1 / 000 1 1. List extra codes in sequence, separated by commas. 2. Please specify range in plain text.

Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 5/6 Order details: Indoor, outdoor and duct resistance thermometers (1) Basic version 902523/20 Duct resistance thermometer with stepped protection tube, Protection IP65 902523/25 Duct resistance thermometer with plain protection tube, Protection IP54 (2) Operating temperature in C x 380 50 to 200 C (standard) x 568 30 to 60 C (range only in conjunction with extra code 330 or 333) x 572 30 to 80 C (standard) x 807 0 to 60 C (range only in conjunction with extra code 330 or 333) (3) Measuring insert x x 1003 1 x Pt100 in 2wire circuit x x 1005 1 x Pt1000 in 2wire circuit x x 1009 1 x Ni 1000 in 2wire circuit x 2003 2 x Pt100 in 2wire circuit (4) Tolerance class to EN 60 751 x x 1 Class B (standard) x x 2 Class A x 3 Class 1/3 DIN (5) Protection tube diameter D in mm x x 6 6mm (Type 902523/20: stepped down from 6mm dia. to 3.3mm dia.) (6) Nominal length NL in mm (50 NL 500) x x 100 100mm x 150 150mm x 200 200mm x... please specify in plain text (in 50mm steps) (7) Process connection x x 000 no process connection x x 252 screwed pipe joint G 1/4 (1/4" pipe) x x 254 screwed pipe joint G 1/2 (1/2" pipe) x x 662 stop flange 6mm dia. (8) Extra codes x x 000 no extra code x 310 protection tube stepped down from 6mm dia. to 3.3mm dia. x 330 analog transmitter, 4 20mA 2 output (in conjunction with 1 x Pt100)* x 333 analog transmitter, 0 10V 2 output (in conjunction with 1 x Pt100)* x 404 Protection IP65 (1) (2) (3) (4) (5) (6) (7) (8) Order code /,... Order example 902523/20 572 1003 1 6 100 252 / 000 1 1. List extra codes in sequence, separated by commas. 2. Please specify range in plain text

Phone: 49 661 60030 Fax: 49 661 6003607 email: mail@jumo.net Phone: 44 1279 635533 Fax: 44 1279 635262 email: sales@jumo.co.uk 1800554JUMO Data Sheet 90.2523 Page 6/6 Stock versions (1) (2) (3) (4) (5) Sales No. / 902523/10 572 1001 1 / 000 90/00065671 902523/10 803 1003 1 / 330 (0 to 40 C) 90/00064003 902523/10 807 1003 1 / 330 (0 to 60 C) 90/00065717 902523/11 635 1003 1 / 000 90/00055723 902523/12 572 1003 1 / 000 90/00064881 902523/12 807 1003 1 / 330 (0 to 60 C) 90/00064883 902523/13 572 1003 1 / 000 90/00419733 902523/13 572 2003 1 / 000 90/00419734 902523/13 568 1003 1 / 330 (30 to 60 C) 90/00419736 (1) (2) (3) (4) (5) (6) (7) (8) Sales No. / 902523/20 572 1003 1 6 100 662 / 000 90/00064894 902523/20 568 1003 1 6 100 662 / 330 (30 to 60 C) 90/00065087