10Km Gigabit Ethernet SFP Transceiver

Similar documents
SFP Bi-Directional Transceiver

P/N: SPC-MR-LR-xx Multi-Rate CWDM SFP Transceiver (LR)

SPL EBX-IDFM SPL EBX-IDFM

Features. Feature Standard Performance. MIL-STD-883E Method

Features. Feature Standard Performance. MIL-STD-883E Method FDA 21CFR and EN (IEC) ,2 2002/95/EC 4.1&4.

Features. Method GR-1089-CORE. Immunity IEC Compatible with standards. FDA 21CFR and Compatible with Class I laser

SPG-FE-FX-IDFC SPG-FE-FX-CDFC

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

1.25Gbps SFP Optical Transceiver, 550m Reach

CWDM SFP 1.25G 40KM LC Duplex

10Gbps 1310 nm MQW-DFB Laser Diode Module-TOSA

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

Features. Feature Standard Performance Electrostatic Discharge. Class 1(>1000V for SFI (ESD) to the Electrical Pins Method

10Gbps 1270/1330nm SFP+ BIDI TRx 40km

GP C(D) 155Mbps SFP Optical Transceiver, 2km Reach

XSS311-20LY. 1.25Gbps SFP Optical Transceiver, 20km Reach. Features. Applications. Description

Single Fiber 1.25Gbps Bi-directional Optical Transceiver SFP with Digital Diagnostics

LX21 100Mb/s to 1.25Gb/s BX-U

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

Product Datasheet GLC-LH-SM-SE-TAA. ClearSourceIT. Product Features. Applications. Description. Statement of TAA Compliance EMC

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

Features. Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins. MIL-STD-883E Method

1G SFP CWDM nm 80km Optical Transceivers

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

1.25Gbps SFP Optical Transceiver, 550m Reach

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

4.25 Gb/s Fibre Channel Single Mode Transceiver

SPQ-10E-SR-CDFG 40G QSFP+ Transceiver

Features. MIL-STD-883E Method FDA 21CFR and Compliant with Class I laser product. RoHS 2011/65/EU Compliant with RoHS

GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

10Gbps 1330/1270nm SFP+ BIDI TRx 80km

155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

SFP+ 16G 1310nm Single mode Optical Transceiver

RoHS Compliant Small Form Factor Pluggable Transceiver for Gigabit Ethernet and Fiber Channel

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

1.25Gb/s 160km DWDM SFP Transceiver (OP340GD-D ) Hot Pluggable, Duplex LC, 100GHz, DWDM DFB & APD, Single-mode, DDM

SFP Optical Transceivers

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

GPB-5303x-L2x(D) 155Mbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

LCP-1250A4FDRx RoHS Compliant Multimode SFP Transceiver for GbE and Fiber Channel

Multimode 1.25Gbps 850nm Optical Transceiver SFP with MSA

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

Product Features Applications Descriptions Ordering Information

Product Features. Applications. Descriptions. Ordering Information. Pin Description

SFP-LX 1.25Gb/s Single-Mode SFP Transceiver 1000BASE-LX Gb/s Fiber Channel

XSB531-20xx Gbps SFP Bi-Directional Transceiver, 20 km Reach, 1550 nm TX/1310 nm RX. Features. Applications. Description

RoHS Compliant Multi-Rate CWDM SFP Transceiver for SONET OC-48/SDH STM-16 with DDM Function

Fiber Channel 2.125Gbps Multimode Optical Transceiver SFP with MSA

Singlemode 1.25Gbps Optical Transceiver SFP with MSA

RoHS Compliant SFP Transceiver for SONET OC-48/SDH STM-16 with Digital Diagnostic Monitoring Function

SFP 4.25G 850nm Multi mode Optical Transceiver

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

2.67Gbps CWDM SFP Optical Transceiver, 40km Reach GPC-xx48-04X(D)

SFP CWDM 1.25G nm Single mode Optical Transceiver

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

Multimode 155Mbps Optical Transceiver SFP with Digital Diagnostic

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

PRE-SFP-OC Mb/s Transceiver, 1310 nm, 15 km (IR1), DDM

2 Mb/s IEEE C37.94 Multi-Mode Transceiver

1.25Gbps SFP Optical Transceiver, 20km Reach GP L2x(D)

TPP3XGDS0x000E2G 850nm SFP+ Transceiver

RoHS Compliant SFP Transceiver for ATM, SONET OC-3/SDH STM-1 with Digital Diagnostic Monitoring Function

MGS-MM MODULO GBIC SFP 500M 4.25GBPS LC MM 850NM VCSEL PIN TRANSCEIVERS

Multi-Rate Gigabit Ethernet & Fiber Channel SFP Transceivers with Digital Diagnostics

AA E6-A AA E6-A. Features. Up to 1.25Gb/s Data Links. Hot-Pluggable. Duplex LC connector. Up to 10km on 9/125μm SMF

PRE-SFP-OC Gb/s Transceiver, 1310 nm, 15 km (IR1), DDM

10Gb/s CWDM SFP+ 20Km RT-P10LCM-C00-xx. Optical Transceiver

SFP-GE-LX Gigabit Ethernet-Singlemode Transceiver SFP, Duplex LC Connector, 1310nm DFB 40km for Single Mode Fiber, RoHS Compliant

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

155Mbps 850nm Multimode Optical Transceiver Small Form Pluggable (SFP)

3.3V / 1310 nm / 1.25 Gbps Digital Diagnostic LC SFP SINGLE-MODE TRANSCEIVER

Parameter Symbol Min Typ Max Unit Remarks Data Rate DR GBd IEEE 802.3ae Bit Error Rate BER Input Voltage V CC

SFP+ Series SFP-10G-SR

Parameter Symbol Min Max Unit Storage Temperature T ST Case Operating Tempature Tc Supply Voltage V CC V

F i n i s a r. Product Specification. Long-Reach DWDM SFP Transceiver FWLF1631Rxx PRODUCT FEATURES

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

Singlemode 155Mbps Optical Transceiver SFP with MSA

TRPUFEALXx000E1G Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers With Digital Diagnostics

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

JD061A-C. 1.25Gbps SFP Transceiver

Singlemode 155Mbps Optical Transceiver SFP with Digital Diagnostic

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

ProLabs LX-SFP-1G-C 1.25GBd SFP (Small Form Pluggable) Long Wavelength (1310nm) Transceiver

Multi-rate Gigabit Ethernet & Fibre Channel SFP Transceivers with Digital Diagnostics

Features. RX Sensitivity (dbm) TX Power (dbm) Voltage (V) SFP-Dual-LC 1.25G MMF 2Km ~ -9 < AC/AC TTL N -5 ~ +70 A56L-BN13-A6MA

Transcription:

Features Data Rate 1.062 to 1.25 Gb/s Single 3.3V Supply 10km Reach 13dB Typical Link Budget Commercial, Reduced and Industrial Temp. Operation 1310nm FP Laser Fibre Channel 100-SM-LC-L Compliant Gigabit Ethernet IEEE 802.3ah Compliant SFP MSA SFF-8074i Compliant Telcordia GR-468 Compliant Digital Diagnostic SFF-8472 Compliant Color code Bail Latch : Blue RoHS-5/6 compliant product (lead exemption) (-xxa) RoHS-6/6 compliant product (no exemption) (-xxc) General Operation Parameter Symbol Min. Typ. Max. Unit Supply Voltage V cc 3.135 3.3 3.465 V Total Current I CC - - 300 ma Power Supply Rejection a PS00 - - mvp-p Operating Case Temperature (-CXX) T opr -5-70 ºC Operating Case Temperature (-RXX) T opr -20-85 ºC Operating Case Temperature (-TXX) T opr -40-85 ºC Storage Temperature T stg -40-85 ºC Data Rate GbE DR - 1250 - Mbps Data Rate FC DR - 1062.5 - Mbps a) 20Hz to 155MHz Transmitter Specifications (Optical) Optical Power P op -9-5 -3 dbm Average Launch Power (Tx:Off) P off - - -30 dbm Extinction Ratio ER 9 - - db Eye Mask IEEE 802.3ah compliant Total Jitter TJ - - 200 ps Optical Rise Time b t r - - 260 ps Optical Fall Time b t f - - 260 ps Mean Wavelength λ 1270 1310 1355 nm Spectral Width (RMS) λ IEEE 802.3ah 1000BASE-LX10 Compliant Relative Intensity Noise RIN - - -120 db/hz b) 20%-80% values 1

Transmitter Specifications (Electrical) Input Differential Impedence R in 80 100 120 Ω PECL Single Ended Data Input Swing V in, p-p 250-1200 mv TxFault_Fault V fault 2 - V cc V TxFault_Normal V normal V ee - V ee + 0.5 V TxDisable_Disable V d 2 - V cc V TxDisable_Enable V en V ee - V ee + 0.8 V Receiver Specifications (Optical) Receiver Power Low c R sens,low - -24-22 dbm Receiver Power High c R sens,high -3 0 - dbm Damage Threshold for Receiver P in, damage 6 - - dbm Wavelength d λ 1270-1355 nm Maximum Reflectance of Receiver RX_r - - -12 db LOS Assert - -38 - - dbm LOS De-Assert - - - -22 dbm LOS Hysteresis - 0.5 - - db c) Measured at BER of 10-12, PRBS of 2 7-1, at eye center d) Operational over 1200-1625nm range Receiver Specifications (Electrical) PECL Single-Ended Data Output Swing V out,p-p 185-800 mv Data Output Rise Time t r - - 260 ps Data Output Fall Time t f - - 260 ps Timing and Electrical Timing and Electrical Timing and Electrical Tx Disable Negate Time t_on - - 1 ms Tx Disable Assert Time t_off - - 10 µs Time to Initialize, Including Reset of Tx Fault t_init - - 300 ms Tx Fault Assert Time t_fault - - 100 µs Tx Disable to Reset t_reset 10 - - µs LOS Assert Time t_loss_on - - 100 µs LOS De-assert Time t_loss_off - - 100 µs Serial ID Clock Rate f_serial_clock - - 100 KHz RX_LOS Voltage (high) Rx_LOS H 2 - V cc V RX_LOS Voltage (low) RX_LOS L - - 0.8 V LOS Output Voltage-Fault V LOS fault 2 - V cc V LOS Output Voltage-Normal V LOS normal V ee - V ee + 0.5 V MOD_DEF (0:2)-High V h 2 - Vcc V MOD_DEF (0:2)-Low V I V ee - V ee + 0.5 V 2

Diagnostics Parameter Range Accuracy Unit Calibration Formula Temperature (-CDA) -5 to 70 ±3 ºC Internal Tc(C) = Tad(16 bit signed twos complement)/256 Temperature (-RDA) -20 to 85 ±3 ºC Internal Tc(C) = Tad(16 bit signed twos complement)/256 Temperature (-TDA) -40 to 85 ±3 ºC Internal Tc(C) = Tad(16 bit signed twos complement)/256 Voltage 0 to Vcc 0.1 V Internal V(Volts) = Vad(16 bit unsigned integer)*0.1 Bias Current 0 to 120 5 ma External I(mA) = Islope * Iad(16 bit unsigned integer)+ioffset Tx Power -9 to -3 ±3dB dbm External Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+tx_pwroffset Rx Power -22 to -3 ±3dB dbm External Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 Pinout Definitions Pin Function Notes 1 V ee T TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 V ee R RX Ground 10 V ee R RX Ground 11 V ee R RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 V ee R RX GND 15 V CC R RX Power 16 V CC T TX Power 17 V ee T TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 V ee T TX GND 3

EEPROM Serial ID Name of Field Discription of Field Address Hex ASCII 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N Vendor Name SFP Vendor name (ASCII) 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C Vendor OUI IEEE vendor OUI code for LuminentOIC Inc. 37 00 38 06 39 B5 Vendor P/N Part number in ASCII, e.g. -CDA 40 53 S 41 50 P 42 47 G 43 42 B 44 4C L 50 58 X 51 43 C 52 44 D 53 41 A 4

Outline Drawing Units in mm(inch) 5

Suggested Transceiver interface Vcc 1 H 10 F 0.1 F 1 H VCC T Protocol IC 10K LuminentOIC SFP TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT Laser Driver SerDes TD + 100 TD - VEE T VCC R 10 F 0.1 F Receiver Amplifier RD + 100 RD - RX_LOS RX_LOS Vcc R 1 VEE R EEPROM =4.7K to 10K MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 6

Ordering Information Available Options: -CDA -CNA -CDC -CNC -TDA -TNA -TDC -TNC -RDA -RNA -RDC -RNC Part numbering Definition: SP - GB - LX Temperature Diagnostic Revision - Customer Specific SP = Small Form Pluggable GB = 1.25Gbps LX = IEEE 802.3 LX Interface C = Commercial (-5 to 70ºC) R = Reduced (-20 to 85ºC) T = Industrial (-40 to 85ºC) D = Digital Diagnostic N = No Digital Diagnostic Design Revision A = RoHS-5/6 compliant product (lead exemption) C = RoHS-6/6 compliant product (no exemption) Blank = Standard Procedure Labelling, Serial number, or Shipping Instructions, etc. Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company s standard one-year warranty; however, specifications designated as preliminary are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN AS IS BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. LuminentOIC, Inc. 2003 All rights reserved 7