Intelligent Power Stabilizer & Up-converter

Similar documents
Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

REVISION DESCRIPTION:

Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

CNV-ALT2. Introduction. 1 Features. RS232 serial altitude to parallel Gillham code for mode C transponders. Operating Manual English 1.

Earth Fault Indicator EFI-BLZ-50 User Manual

MGL Avionics Garrecht VT-0102 mode-s transponder Interface installation manual

Trinity-1 Power Controller

Howard Smart Transformer Specification Guide

MGL Avionics. SP-9 AHRS and magnetometer. User and installation manual

SP-6 magnetometer. User manual. Installation and in-flight calibration

Automotive Surge Suppression Devices Can Be Replaced with High Voltage IC

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM. Unit Objectives. Unit Objectives 2/29/2012

Instructions for Continued Airworthiness Supplement

Installation Manual. AG-NAV Platinum. Differential GPS Guidance System. AG-NAV Inc. 30 Churchill drive Barrie, Ontario CANADA, L4N8Z5

Chapter 12 Electric Circuits

Sportsman Service Bulletin 66A - Corrective Action

Post-Installation Checkout All GRT EFIS Models

IA SERIES OWNER'S MANUAL

Garmin GNS430/530 Series Equipment Supplement

AUTO CAL II PO Box Sta Safety Road Houma, LA Tel # Fax #

SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System

POW-R-BLOK TM Dual Diode Isolated Module 600 Amperes / Up to 2400 Volts. LD41 60 Dual Diode POW-R-BLOK TM Module 600 Amperes / Volts

SC1000 DGPS USCG Dual Transmitter

ECE 454 Homework #1 Due 11/28/2018 This Wednesday In Lab

Digiflight II SERIES AUTOPILOTS

MASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT

MGL Avionics ibox V1 Installation manual Preliminary. Document date June

Substation: From the Outside Looking In.

Aircraft Radio Installation Guide Mgl Avionics

Power-IO

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

TECHNICAL PRODUCT DATASHEET

ENGINEERING STANDARD FOR INSTRUMENTS ELECTRICAL POWER SUPPLY AND DISTRIBUTION SYSTEMS FIRST EDITION MAY 2013

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

CIRRUS AIRPLANE MAINTENANCE MANUAL

High Frequency/Precision Drives by Design

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Product: GenX Mobile 5p Device

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Total Ionizing Dose Test Report. Z-Series DC-DC Converter

Page Type Resolution (mm) min. max. Output

Autopilot Servo Installation Guide

Operator's Manual. 2 Place Aircraft Trim Mixer

TOSHIBA International Corp

NCS3 Series Isolated 3W 4:1 Input Single Output DC-DC Converters

A53106 SERIES DC-TO-DC CONVERTER

Autopilot Servo Installation Guide

Operating Handbook For FD PILOT SERIES AUTOPILOTS

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

INSTALLATION MANUAL Multi-Function Digital Bus Reader Model IND-5000, P/N (XX) TACAN, Distance & Bearing June 1997

Direct Digital Control of package units, VAV boxes, and other terminal unit applications. The TCX 840

Power Quality Solutions

LDR3 Outline Dimensions. Dimension Inches Millimeters

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

-treme thread cutting. Tiny Tools. New Products. Metric

SPECIAL SPECIFICATION 1118 Data Fiber Optic Transceiver

VPTHVM-270 Series HIGH RELIABILITY COTS REGULATED BUS CONVERTER MODULE DESCRIPTION FEATURES

Pilot s Operating Handbook Supplement AS-21

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

Table of Contents. Introduction 3. Pictorials of the 40 and 50 Systems 4. List of Applicable Acronyms 6

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

02/11/2015

American Electrical Institute

RB single and dual-output DC/DC converters 14 32Vin & 18 32Vin, 5 28Vout, watts

Arbitrary power supplies. 160 W to 5200 W

Correlation of Voltage and Temperature Measurement

Modeling of Lightning Direct Effects Interaction of Continuing Current with Aluminum Skins

IB6 Series Solid-State Isolation Relay

POW-R-BLOK TM Dual SCR/Diode Isolated Module 150 Amperes / Up to 1800 Volts CD62 15B, CD67 15B

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

BUCK-BOOST TRANSFORMERS

C I R R U S EMERGENCY DESCRIPTION A. Emergency Locator Transmitter (ELT)

A 11/89. Instruction Manual and Experiment Guide for the PASCO scientific Model SF-8616 and 8617 COILS SET. Copyright November 1989 $15.

2. Power supply for equipment operated by AC (see Examples 1,2 and 3) 3. Power supply for equipment operated by DC (see Examples 4,5 and 6)

General Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation...

SAE5-35. Altitude Data System Installation Manual Rev. 4. SANDIA aerospace, Inc.

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment

High-impact resistant thermoplastic construction

Grounding and Bonding of Service Equipment

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

CAUTION. RXM5010 Touchscreen Remote Installation and Operation Manual MODEL: RXM5010

Harmonics, its Mitigation & Result of Case study of Spinning Mill

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Abstract. PEGASUS Toroidal Experiment University of Wisconsin-Madison

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

PD POW-R-BLOK TM Dual SCR Isolated Module 700 Amperes / Up to 1800 Volts

The Isolator/Surge Protector (ISP)

The Isolator/Surge Protector (ISP)

Rev J Automatic Pitch Trim

PSL - Power Sensors Ltd

FC Series Signal Conditioners

Transcription:

Intelligent Power Stabilizer & Up-converter Model: IPS-24v-5a The Intelligent Power Stabilizer, IPS, is an electronic power converter for critical electrical equipment found in general aviation aircraft. The IPS system provides aircraft bus voltage surge and sag protection for the connected electrical equipment. The IPS system will operate over an input voltage range from 10 volts to 30 volts and provides a regulated output voltage of 24 volts. The IPS system allows electronic equipment such as engine monitors, EFIS and GPS s and radios to be operational before and during engine starting. This important feature allows the pilot to load flight plan data into the aircraft GPS prior to starting the engine, thereby saving fuel and operating expense. When used with aircraft engine monitors it ensures the pilot can monitor critical engine operating parameters such as oil pressure during the engine starting process. The electronic power converter in the IPS system ensures the connected electronic equipment is provided with a stabilized source of power even when the aircraft battery voltage drops significantly. This is particularly important during engine starting or alternator out conditions. IPS additionally provides surge protection by actively clamping the regulated output voltage. The IPS-24V may also be used as an up converter for electronic equipment requiring 24 volts from a standard 12 volt aircraft power bus. The Intelligent Power Stabilizer system is suitable for use with equipment such as Garmin GNS-430/wa, GNS-530/wa, G900X, G3X systems. Advanced Flight System EFIS, Dynon EFIS, Grand Rapids EFIS, MGL EFIS, Tru-trak Autopilots. The IPS system may also be used for operating 24 volt radios and electronics such as those utilized in the Garmin G900x system and the GNS 430W-A / GNS-530W-A systems in 12 volt aircraft. No other uses of the IPS system are permitted except for those identified in this installation manual. IPS must be installed using the current aircraft standards and practices. Refer to AC 43.13-2A/1B. The installer/builder is solely responsible for determining the suitability of the installation and use of this product. 1

Installation instructions: 1. IMPORTANT NOTE: Consult the attached wiring diagrams to identify wiring connections similar to your particular installation. Please note, some equipment such as GPS s and EFIS systems may be provided with multiple power inputs. For these installations the IPS system must be connected on the back-up power input. It is strongly recommended that the main power input in these installations be provided from the aircraft avionics bus. The back-up power source should be provided through the IPS system and fed from a bus that is active during engine starting. This will typically be the master bus. For equipment having a single source of power, ensure the IPS system is fed from a bus that remains active during engine starting, such as the master bus. Garmin 430/530(w) GPS systems are available in versions with and without back-up power inputs. Consult the Garmin GPS installation manual to determine which model you are working with, wiring diagrams for connection of each type to the IPS system are shown at the end of this document. 2. Check the total connected load to be used with the IPS system and ensure that it is less than the following product ratings. IPS-24v-5a = 5 amps maximum continuous current, 10 amps peak 3. Mount the IPS power converter in a suitable location in the aircraft. The IPS must be mounted inside the aircraft, do not mount IPS in the firewall forward area. 4. Connect the aircraft wiring according to the wiring diagrams as shown. The IPS must be powered through a properly sized circuit breaker or fuse. ENSURE the proper size wire is utilized for the input feed and ground connection powering the IPS system Additionally, the output of the IPS must be fused as shown in the wiring diagrams. FUSING: For continuous loads: Input Fuse = 15 amps, Output Fuse= 5 amps For radios and transient loads: Input Fuse = 20 amps, Output Fuse= 7.5 amps 2

SPECIFICATIONS: Input Voltage: Output Voltage: Output Current: Converter: 10-30 volts DC >24.0 volts DC IPS-24v-5a 5 amps continuous, 10 amps peak True DC:DC converter with output over voltage, over current and over temperature protection Surge Protection: Wiring: Enclosure: Weight: 32 volt active clamp, 1500w 10/1000uS waveform IPS-24v-5a : insulated barrier strip, #6 screws Cast aluminum IPS-24v-5a : 4.6 x 3.7 x 1.18 IPS-24v-5a : 14 oz. Temperature range: -25 C to 55 C 4

Intelligent Power Stabilizer TM Wiring Diagram IPS-24v-5a UP-CONVERTER MODE V+in Grd V+Out 5-7.5 amp output fuse Main Power Input 15 amp fuse 12 volt Main Bus 24 Volt Equipment being powered via IPS Master Solenoid 12 volt Battery Example wiring for up-converting from 12 volt to 24 volts 5

Intelligent Power Stabilizer TM Wiring Diagram IPS-24v-5a Equipment with Back-up Power Input V+in Grd V+Out 5-7.5 amp fuse Back-up Power Input Avionics Bus Solenoid Equipment powered via IPS 15 amp fuse Avionics Bus Main Power Input Main Bus Master Solenoid 24 volt Battery Example wiring for systems with back-up power inputs 24 volt system utilizing IPS surge and sag protection 6