MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Similar documents
Extract from the online catalog

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

MACX MCR-EX-SL-RPSSI-I

Signal conditioner - MACX MCR-UI-UI-NC

DEK-OV- 12DC/ 24DC/ 3

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

AKG 4 GNYE. Extract from the online catalog. Order No.:

PSR-SCP- 24DC/ESD/5X1/1X2/300

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-I-LP-NC

KDS10/SO. Extract from the online catalog. Order No.:

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

UTTB 4. Extract from the online catalog. Order No.:

UTTB 2,5. Extract from the online catalog. Order No.:

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

VC-MEMV-S1. Extract from the online catalog. Order No.:

KDSP 4. Extract from the online catalog. Order No.:

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

VC-MEMV-K3. Extract from the online catalog. Order No.:

VC-MP-K1. Extract from the online catalog. Order No.:

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

SAC-3P- 5,0-PUR/M12FR SH

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

SAC-5P- 1,5-PUR/M12FS SH

MACX MCR-UI-UI-UP(-SP)(-NC)

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Extract from the online catalog

MINI MCR-SL-UI-f(-SP)

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MKDS 3/ 4. Extract from the online catalog. Order No.:

SLKK 5. Extract from the online catalog. Order No.:

QUINT-PS-24DC/24DC/10

MINI-PS AC/24DC/1.3

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Safety relays - PSR-SCP- 24DC/ESD/4X1/

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Technical Information Barrier RB223

Temperature Input Module for Zone 1 Series 9482/32

CompactLogix 5370 L3 Control System

Analog Universal Module HART for Zone 2 Series 9468/33

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Temperature transmitter itemp RTD DIN rail TMT 127

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

High-current terminal block - UKH

Temperature transmitter itemp PCP DIN rail TMT 121

Coupling Relays and Converters

0 2 1 â Ó. itemp HART TMT182. Technical Information

Temperature Transmitter itemp RTD DIN rail TMT 127

Isolators A3/1. Vibration Transducer Supply Unit Series

Temperature head transmitter itemp TC TMT 188

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

0 2 1 â Ó. itemp HART TMT182. Technical Information

Feed-through terminal block - PT 10-TWIN

VariTrans P D1 TRMS

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2DYS SEN TRONIC AG

5 years! Modular Housings. VariTrans P Warranty

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Miniature resistance thermometer Model TR33, thread-mounted

Assembly. Front view. Parametrization interface. Power Bus

Rail mounted Temperature Transmitter TH102/TH102-Ex

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

MINI-PS AC/2X15DC/1

Field indicator for current loops with HART communication Models DIH50, DIH52

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Type CP-S, CP-C & CP-A Switch mode

Isolating Repeater Input Series 9163

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

itemp HART DIN rail TMT112

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Positioner with HART Communication Type 3780

VariTrans P V. Safe and Sound.

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Resistance thermometer Model TR31, miniature design

Transcription:

Extract from the online catalog MCR-C-UI-UI-DCI Order No.: 2810913 MCR 3-way isolating amplifier, with configurable I/O, for the electrical isolation of analog signals, with GL approval, preconfigured. For information about permissible signal combinations, please refer to the data sheet. Commercial data Pack 1 pcs. Customs tariff 85437090 Weight/Piece 0.1426 KG Catalog page information Page 360 (IF-2009) Product notes WEEE/RoHS-compliant since: 06/30/2006 http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Product description The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals. The device provides electrical isolation of analog standard signals. The module input and output are supplied via integrated DC/DC converters, which are electrically isolated from the mains (3-way isolation). The required auxiliary voltage is indicated via a green power LED. This clearly indicates whether or not auxiliary voltage is available. PHOENIX CONTACT Inc., USA Page 1 / 7

The MCR module ensures the safe decoupling of a sensor circuit from the evaluation circuit and also prevents the negative effects of several sensor circuits connected with one another. 3-way isolation enables the universal use of modules both locally and close to the control system for signal conversion and electrical isolation, as well as on the transmission path for jumpering high load resistors. Signals are converted by an inductive transmission method. In addition, a filter connected downstream of the transmitter reduces possible interference. Technical data Input data Configurable/programmable Voltage input signal Max. input voltage Max. input current Input resistance of voltage input Input resistance current input Yes, preconfigured 0 V... 10 V (please indicate any different setting when ordering) 30 V 50 ma 1 MΩ 50 Ω Output data Configurable/programmable Voltage output signal Max. output voltage Max. output current Load/output load voltage output Load/output load current output Yes, preconfigured 0 V... 10 V (please indicate any different setting when ordering) 15 V 30 ma 10 kω 500 Ω Power supply Range of supply voltages Max. current consumption 18 V DC... 30 V DC < 30 ma (without load) Connection data Type of connection Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 14 Stripping length 8 mm Screw thread M3 Connection method COMBICON PHOENIX CONTACT Inc., USA Page 2 / 7

General data No. of channels 1 Width 17.5 mm Height 99 mm Depth 114.5 mm Transmission error, max. 0.1 % (of end value) Maximum temperature coefficient 0.0075 %/K Limit frequency (3 db) 30 Hz Alignment zero ± 2 % Alignment span ± 2 % Step response (10-90%) 11 ms Protective circuitry Transient protection Ambient temperature (operation) -20 C... 65 C Degree of protection IP20 Electromagnetic compatibility Conformance with EMC directive 2004/108/EC Emitted interference EN 61000-6-4 Immunity to interference EN 61000-6-2:2005 Color green Housing material Polyamide PA non-reinforced Mounting position Any Conformity CE compliant UL, USA / Canada Class I, Div. 2, Groups A, B, C, D or non-hazardous locations GL Germanischer Lloyd Certificates / Approvals Certification CUL, GL, GOST, UL Certification Ex: CUL-EX LIS, UL-EX LIS PHOENIX CONTACT Inc., USA Page 3 / 7

Configuration options Input signal Output signal Plant calibration certificate 0...20 ma [IN01] 4...20 ma [IN02] 0...10 V [IN03] 0...5 V [IN05] 1...5 V [IN06] -60...+60 mv [IN13] -100...+100 mv [IN14] -200...+200 mv [IN15] -300...+300 mv [IN16] -500...+500 mv [IN17] -1...+1 V [IN18] -2...+2 V [IN19] -2.5...+2.5 V [IN20] -5...+5 V [IN21] -10...+10 V [IN22] -20...+20 V [IN23] 0...60 mv [IN24] 0...100 mv [IN25] 0...200 mv [IN26] 0...300 mv [IN27] 0...500 mv [IN28] 0...1 V [IN29] 0...2 V [IN30] 0...2.5 V [IN31] 0...20 V [IN32] -5...+5 ma [IN33] -10...+10 ma [IN34] -20...+20 ma [IN35] 0...5 ma [IN36] 0...10 ma [IN37] 0...20 ma [OUT01] 4...20 ma [OUT02] 0...10 V [OUT03] 0...5 V [OUT05] 1...5 V [OUT06] -5...+5 V [OUT13] -10...+10 V [OUT14] 0...5 ma [OUT15] 0...10 ma [OUT16] No plant calibration certific. [NONE] Certificate without test data [YES] Certificate with test data [YESPLUS] PHOENIX CONTACT Inc., USA Page 4 / 7

Diagrams/Drawings Application drawing Application example: Level measurement Dimensioned drawing Circuit diagram PHOENIX CONTACT Inc., USA Page 5 / 7

Approbationslogos (EX-Bereich) PHOENIX CONTACT Inc., USA Page 6 / 7

Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com 2010 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA Page 7 / 7