TE200S Solid State Relays. Two-phase control of three-phase loads. User manual

Similar documents
controller loads TE300 Three-phase User Manual

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

ESwitch. User Guide. Power Contactor

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

3B SCIENTIFIC PHYSICS

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Power supply CP-D 24/4.2 Primary switch mode power supply

HAWK5000 Operators Manual

Installation and Operational Instructions for ROBA -switch Type 017._00.2

MINI-PS AC/24DC/1.3

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

QUINT-PS/ 3AC/24DC/10

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

QUINT-PS-24DC/24DC/10

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

3B SCIENTIFIC PHYSICS

Essential Power Control

r ADDENDUM FOR REAR-OF-BOARD VERSION LFS - R

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

SEPARATOR P20G TYPE USER S MANUAL

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

QUINT-PS AC/24DC/40

Installation and Operating Instructions for Phase Demodulator Type _.2

Power supply CP-D 12/2.1

Zelio Control Measurement Relays

MINI-PS AC/2X15DC/1

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

RMO500 M I C R O O H M M E T E R

CCH400 & CCH600 Series

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Power supply CP-T 48/20.0 Primary switch mode power supply

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

CONTENTS XV300K GB r doc XV300K 2/13

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Power supply CP-T 24/20.0 Primary switch mode power supply

AC MASTER Switch mode sine wave inverter

To be automatically connected to the nearest North American Technical Sales Office:

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power supply CP-E 24/2.5

10-CH Digital Thermometer Module

QUINT-PS/ 3AC/24DC/40

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Power supply CP-E 24/20.0

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Power supply CP-D 24/1.3

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

MODEL 3810/2 Line Impedance Stabilization Network

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

MINI MCR-SL-UI-f(-SP)

Power supply CP-E 24/0.75

AC/DC Power Supply Series APPLICATION NOTE

J IPC IGBT power converter

Power supply CP-T 48/5.0 Primary switch mode power supply

MW3105 DIGITAL CLAMP MULTIMETER

Type CP-S, CP-C & CP-A Switch mode

QUINT-PS/ 1AC/24DC/20

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

02/11/2015

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DM-45 Digital Multimeter

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

References 1 for asynchronous motors 1

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Operating Instructions. for. Controller SMS 150 / 151

AC/DC Power Supply Series APPLICATION NOTE

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

02/11/2015

Instruction manual for STA 1 sectional door operator

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Power supply CP-E 24/2.5

Power Supplies 3. SDN-C Compact DIN Rail Series

Power supply CP-T 24/10.0 Primary switch mode power supply

Anacon Power & Controls

Electrical Specifications

USER'S MANUAL DMR-6700

AC/DC Power Supply Series APPLICATION NOTE

PRetrans Table of contents

30XR-A Professional Digital Multimeter Users Manual

Phase-sequence Phase-loss Relay

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Electrical Specifications

Instruction manual for STA 1 sectional door operator

Switching power supplies CP range, Linear power supplies CP-L range. Content

Transcription:

TE200S Solid State Relays Two-phase control of three-phase loads User manual Copyright Eurotherm Automation 1998 All rights reserved. All reproduction or transmission in any form or using any procedure (electronic or mechanical, including photocopying or recording) without written authorisation from EUROTHERM AUTOMATION is strictly prohibited. EUROTHERM AUTOMATION has made every effort to ensure that the specification given in this manual is as accurate and up to the minute as possible. However, in order to maintain our leading edge, it may be necessary to make certain changes or omissions to our specification. We cannot be held responsible for any damage to persons or property or for any financial loss or costs arising from this. HA175921ENG Iss 1.0 04/98 i

TE200A USER MANUAL CONTENTS Page EUROPEAN DIRECTIVES..........................iv CE MARKING AND SAFETY.......................iv ELECTROMAGNETIC COMPATIBILITY (EMC).......iv DECLARATION OF CE CONFORMITY...............v PRECAUTIONS...................................vi CHAPTER 1 IDENTIFYING THE TE200S SOLID STATE RELAYS...1-2 GENERAL INTRODUCTION TO THE TE200S SERIES.1-2 TECHNICAL SPECIFICATION.....................1-5 PRODUCT CODE................................1-7 EXAMPLE OF PRODUCT CODE...................1-8 SERIAL NUMBER LABELS.......................1-8 CHAPTER 2 INSTALLATION.................................2-2 INSTALLATION - SAFETY........................2-2 DIMENSIONAL DETAILS.........................2-3 MOUNTING DETAILS............................2-5 CHAPTER 3 WIRING........................................3-2 WIRING - SAFETY...............................3-2 CONNECTIONS.................................3-3 POWER WIRING DIAGRAM.......................3-4 USER TERMINAL BLOCKS.......................3-5 WIRING FOR CONTROL AND FAN SUPPLY.........3-8 ii

Page CHAPTER 4 COMMISSIONING PROCEDURE...................4-2 COMMISSIONING PROCEDURE - SAFETY..........4-2 CHECKING THE CHARACTERISTICS..............4-3 POWERING UP..................................4-4 CHAPTER 5 MAINTENANCE.................................5-2 FUSES..........................................5-3 TOOLS.........................................5-5 iii

EUROPEAN DIRECTIVES CE MARKING AND SAFETY TE200S products carry the CE mark in compliance with the essential requirements of the European Low Voltage Directive 73/23/EEC of 19/2/73 (amended by the Directive 93/68/EEC of 22/7/93). For safety reasons, TE200S products installed and used in compliance with this User Manual meet the essential requirements of the European Low Voltage Directive mentioned above. ELECTROMAGNETIC COMPATIBILITY (EMC) For an industrial environment only, must not be used in domestic environments. Eurotherm certifies that TE200S products, installed and used in compliance with these Instructions, meet the following EMC standards and enable the system which incorporates them to comply with the EMC Directive, as far as the TE200S products are concerned. EMC test standards Immunity Generic standard : EN 50082-2 Test standards : EN 61000-4-2, EN 61000-4-4, EN 61000-4-3, EN 61000-4-6,ENV 50204 Emission Generic standard : EN 50081-2 Test standard : EN 55011 Class A Product standard : IEC 1800-3 second environment (industrial environment) Internal EMC filters EMC filters are incorporated in the TE200S to reduce conducted emission in accordance with the corresponding test standard. EMC Guide In order to help reduce the effects of electromagnetic interference depending on the product installation, Eurotherm can supply the 'Electromagnetic Compatibility' Installation Guide (ref: HA 025464). This guide lists the rules generally applicable for EMC. iv

DECLARATION OF CE CONFORMITY A declaration of CE conformity is available on request. Validation by Competent Body Eurotherm has validated the compliance of TE200S products with the European Low Voltage Directive and with EMC standards through product design and laboratory testing. The tests carried out on TE200S products are listed in a Technical Construction File validated by the LCIE (Central Laboratory for the Electrical Industries), a Recognised Competent Body. Further information For any further information, or if in doubt, please contact Eurotherm Controls where qualified staff are available to advise or assist you with the commissioning of your installation. v

PRECAUTIONS Safety symbols Important safety precautions and special information are indicated in the text of the manual by two symbols: DANGER This symbol means that failure to take note of the information given in this manual may have serious consequences for the safety of personnel and may even result in electrocution.! WARNING This symbol means that failure to take note of the information may have serious consequences for the installation or lead to the incorrect operation of the power unit. These symbols must be observed for particular points. However the whole of the manual remains applicable. Personnel The installation, configuration, commissioning and maintenance of the power unit should only be carried out by personnel qualified and trained to work with low voltage electrical equipment in an industrial environment. Independent alarm Given the value of the equipment controlled by TE200S products it is the responsibility of the user, and it is highly recommended, that an independent safety device (alarm) should be installed. This alarm must be tested regularly. Eurotherm can supply suitable equipment vi

IDENTIFYING THE SOLID STATE RELAYS Chapter 1 IDENTIFYING THE TE200S SOLID STATE RELAYS Page GENERAL INTRODUCTION TO THE TE200S SERIES.......1-2 TECHNICAL SPECIFICATION...........................1-5 PRODUCT CODE......................................1-7 EXAMPLE OF PRODUCT CODE.........................1-8 SERIAL NUMBER LABELS.............................1-8 1-1

IDENTIFYING THE SOLID STATE RELAYS Chapter 1 IDENTIFYING THE TE200S SOLID STATE RELAYS GENERAL INTRODUCTION TO THE TE200S SERIES The TE200S series of solid state relays (SSRs) are thyristor units designed to control the electrical power in industrial three-phase loads. A TE200S series SSR is made up of two channels, each comprising a pair of thyristors connected in anti-parallel, and a direct (unswitched) channel. The TE200S series is designed to control three-phase resistive loads: elements with a low temperature coefficient short-wave infrared elements (except for the 63A model). Three-phase loads can be connected: in star without neutral in closed delta The power wiring is independent of the supply phase rotation. The nominal line-to-line voltage ranges from 200Vac to 500Vac depending on the product code of the unit. The nominal currents, defined at an ambient temperature of 45 C, of TE200S SSRs are between 16A and 63A per phase, depending on the rating of the unit. 70 I rms (A) I N = 63A (fan-cooled) 60 50 I N = 50A 40 30 I N = 40A I N = 25A 20 10 0 I N = 16A Operating temperature ( C) 20 25 30 35 40 45 50 55 60 Figure 1-1 Current derating per phase as a function of ambient temperature (dotted line: current limited by recommended fuse) 1-2

IDENTIFYING THE SOLID STATE RELAYS Supply terminal block Heatsink Upper protective cover TE200S 40A/400V EUROTHERM R (L1) S (L2) ε T (L3) U (T1) V (T2) W (T3) 9 8 LED firing indicator Control signal connector Load terminal block Figure 1-2 Overview of the TE200S solid state relay (non fan-cooled unit) 1-3

IDENTIFYING THE SOLID STATE RELAYS The firing mode for TE200S SSRs is Logic ON/OFF. The SSR can be controlled by DC or AC logic signals (configured at the factory depending on the order code). The electronics of TE200S SSRs are self-supplied from the power voltage and do not require external connections. A TE200S SSR is equipped with: A driver board A firing board which triggers thyristor firing. The filter which provides immunity against electromagnetic interference is located between the power phases. The user terminal block below the SSR is used for input signal connection without needing access to the inside of the unit. A green LED, labelled ON, indicates thyristor firing and is located on the front facia. TE200S SSRs are designed to be bulkhead or DIN rail mounted. The 63A rated unit must be permanently fan-cooled. The fan power supply is 115Vac or 230Vac (to be specified when ordering the SSR). In the event of the SSR overheating, a thermal switch stops thyristor firing in the 63A rated version of the TE200S. Firing becomes possible again after return to nominal thermal conditions. 1-4

IDENTIFYING THE SOLID STATE RELAYS TECHNICAL SPECIFICATION The TE200S series of SSRs is intended for two-phase control of an industrial three-phase load. Power Nominal current (per phase) 16A, 25A, 40A, 50A or 63A (at 45 C) Line-to-line voltage 200Vac to 500Vac (±10%) depending on the voltage code Supply frequency 50Hz and 60Hz (±2Hz) automatic selection Dissipated power 1.3W (approx.) per amp, per phase Insulation (1 min test) Between power and earth: In series 2000Vac, 50Hz Between power and control: In series and 3600Vac, 50Hz. Cooling Natural convection for 16A to 50A rated units Permanent fan-cooling for 63A rated unit Fan power supply 115Vac or 230Vac (selected in order code) Load Resistive three-phase load with a low temperature coefficient Short-wave infrared elements (except for 63A rated unit) Supply phases Wiring independent of the phase rotation Load configuration 3-wire: Closed delta or star without neutral Fuses External (order separately) see chapter 5 CE Marking Electrical safety TE200S SSRs carry the CE mark in compliance with the essential requirements of the European Low Voltage Directive 73/23/EEC (amended by the Directive 93/68/EEC) Electromagnetic compatibility Immunity and Emissions TE200S products comply with Electromagnetic Compatibility test standards (see page iv). 1-5

IDENTIFYING THE SOLID STATE RELAYS Thyristor firing Firing mode Switching Indication Control Signal type DC signal On state Off state AC signal 24 to 48 Vac On state Off state AC signal 100 to 230 Vac On state Off state Logic ON/OFF Firing starts and ends at zero voltage Thyristor firing is signalled by a green LED DC Logic or AC Logic The signal type (DC or AC) is configured at the factory according to the order code; it cannot be re-configured by the user Universal input: voltage or current. Polarity insensitive: + and - can be crossed Guaranteed conditions for firing: voltage greater than 5Vdc or current greater than 5mA Maximum voltage: 32Vdc. Maximum current (self-limited) 10mA at 32Vdc Voltage less than 2Vdc or current less than 0.5mA Typical input impedance 2.2kΩ (50Hz & 60Hz) Guaranteed conditions for firing: voltage from 20Vac to 53Vac Voltage less than 5Vac Typical input impedance 9.6kΩ (50Hz); 8.0kΩ (60Hz) Guaranteed conditions for firing: voltage from 85Vac to 253Vac Voltage less than 10Vac Environment Operating temperature 0 C to +60 C at maximum altitude of 2000m (see page 1-2 for derating curves) Storage temperature -10 C to +70 C Thyristor protection External high-speed fuses except for short-wave infrared application (see chapter 5) Internal MOVs (varistors) and RC snubbers Protection IP20 (in compliance with Standard IEC 529) External wiring To be carried out in compliance with Standard IEC 364 Operating atmosphere Non-explosive, non-corrosive, non-conductive Humidity RH: 5% to 95%, non-condensing, non-streaming Pollution Pollution degree 2 permissible, defined by IEC 664 Over-voltage category III, defined by IEC 664 1-6

IDENTIFYING THE SOLID STATE RELAYS PRODUCT CODE TE200S/Current/Voltage/Cooling/Input signal/mounting/manual/00 Nominal current Code 16 amps 16A 25 amps 25A 40 amps 40A 50 amps 50A 63 amps 63A Input signal Code Logic signal Universal DC LGC AC 24-48Vac LAC AC 100-230Vac HAC Mains voltage (line-to-line) Code 200V, 220V, 230V, 240V 240V 380V, 400V, 415V 440V, 480V 400V 500V 500V Fan supply Code Without fan-cooling (16A to 50A) 000 With fan-cooling (63A): 115Vac 115V 230Vac 230V Mounting Bulkhead DIN rail Manual language French English German* Italian* * Available shortly Code BKD DIN Code FRA ENG GER ITA 1-7

IDENTIFYING THE SOLID STATE RELAYS EXAMPLE OF PRODUCT CODE Solid state relay and installation parameters Nominal load current 35 amps Nominal supply voltage 415 volts line-to-line Input signal AC 48Vac Mounting On DIN rails User manual In English SSR code: TE200S / 40A / 480V / 000 / LAC / DIN / ENG / 00 SERIAL NUMBER LABELS Two identification labels provide all the information relating to the factory settings of the SSR. The identification labels are located on the sides of the unit. EUROTHERM 2.20 WORTHING, ENGLAND : 01903 268500 MODEL : TE200S/40A/480V/000/LAC/DIN/ENG/00 SERIAL No. : INT100/002/001/04/98 0F222935 CURRENT : 40A VOLTAGE : 480V AUX. POWER SUPPLY : SELF-SUPPLIED INPUT : 24-48Vac FAN POWER SUPPLY : NONE FUSE : FERRAZ B093910. ANY NON-SPECIFIED FUSE INVALIDATES GUARANTEE Figure 1-3 Example of identification labels for a TE200S solid state relay. The information corresponds to the product code example! Warning! Following any re-configuration on the part of the user, there is no guarantee that the SSR will correspond to the label information 1-8

INSTALLATION Chapter 2 INSTALLATION Page INSTALLATION - SAFETY..............................2-2 DIMENSIONAL DETAILS...............................2-3 Non fan-cooled solid state relays........................2-3 Fan-cooled solid state relays............................2-4 MOUNTING DETAILS..................................2-5 DIN rail mounting...................................2-5 Bulkhead mounting...................................2-6 2-1

INSTALLATION Chapter 2 INSTALLATION Please read thoroughly before installing the SSR INSTALLATION - SAFETY Danger! TE200S units must be installed by personnel qualified and trained to work with low voltage electrical equipment in an industrial environment. Units must be installed in electrical cabinets correctly fan-cooled to ensure that condensation and pollution are excluded. The cabinet must be closed and bonded to the safety earth in accordance with Standards NFC 15-100, IEC 364 or current national Standards. For installations which are fan-cooled, it is recommended that a fan-failure detection device or a thermal safety cut-out should be fitted in the cabinet. TE200S units may be bulkhead or DIN rail mounted. The units must be mounted with the heatsink positioned vertically, with no obstructions above or below which could inhibit or impede airflow. If several units are mounted in the same cabinet, they should be arranged in such a way that air expelled from one cannot be drawn into the unit located above it.! Warning! The units are designed to be used at an ambient temperature less than or equal to 45 C at full load or up to 60 C at partial load (see Current derating curves, page 1-2). Leave a minimum gap of 5cm between two units placed side by side. Excessive overheating of the SSR may lead to incorrect operation of the unit. This may in turn cause damage to the components. 2-2

INSTALLATION DIMENSIONAL DETAILS Non fan-cooled solid state relays The overall dimensions of non fan-cooled TE200S SSRs (16A to 50A ratings) are given in Figure 2-1. Weight of non fan-cooled TE200S: 2.3kg 116 131 TE200S EUROTHERM 40A/400V R (L1) S (L2) T (L3) ε 18.5 189 152 U (T1) V (T2) W (T3) 9 8 82 Position of power cables 58 Figure 2-1 Dimensions (mm) of non fan-cooled TE200S solid state relay 2-3

INSTALLATION Fan-cooled solid state relay 63A rating TE200S SSRs have permanent fan-cooling. Weight of fan-cooled TE200S: 2.9kg The overall dimensions of the fan-cooled TE200S SSR are given in Figure 2-2. Figure 2-2 Dimensions (mm) of fan-cooled TE200S solid state relay (63A rating) 2-4

INSTALLATION MOUNTING DETAILS TE200S SSRs may be mounted: On two DIN rails (code DIN) On a bulkhead (code BKD) DIN rail mounting For mounting TE200S SSRs, use symmetrical DIN rails to comply with Standard EN 50022. Lip Upper part of back fixing plate DIN rail 1 125 ±0.5 mm 2 DIN rail Fixing clip Lower part of back fixing plate Figure 2-3 DIN rail mounting for TE200S solid state relay To mount the TE200S SSR on DIN rails: 1. Offer up the unit by first engaging the two lips on the upper part of the fixing plate (back plate of SSR) on to the upper DIN rail. 2. Clip the SSR (by its spring clip) on to the lower DIN rail, making sure that the clip is properly engaged. 2-5

INSTALLATION Bulkhead mounting Two fixing plates, supplied with the SSR (code BKD), are used for bulkhead mounting. For this type of mounting, use the following instructions: Drill three holes for M6 screws following the dimensions given in Figure 2-4 Fix the upper plate on to the panel using the oblong hole at the top of the unit Install the lower plate with two M6 screws Insert the fixing lugs of the controller into the lower plate Slightly undo the central screw holding the upper fixing plate in order to slide it upwards, position the controller on the lower fixing plate and slide the upper plate back down on to the slots on the heatsink. Upper oblong hole Not used TE200S EUROTHERM 40A/400V R (L1) S (L2) T (L3) 200 +0-1 U (T1) V (T2) W (T3) Fixing plates 9 8 Not used 105±0.5 Lower fixing plate holes Figure 2-4 Bulkhead drilling and mounting dimensions (in mm) for the TE200S unit 2-6

WIRING Chapter 3 WIRING Page WIRING - SAFETY.....................................3-2 CONNECTIONS.......................................3-3 Power.............................................3-3 Control............................................3-3 Fan (63A rated unit)..................................3-3 Connection details...................................3-3 POWER WIRING DIAGRAM............................3-4 USER TERMINAL BLOCKS.............................3-5 General introduction..................................3-5 Control terminal blocks...............................3-6 WIRING FOR CONTROL AND FAN SUPPLY...............3-8 Control............................................3-8 Fan (63A rated unit)..................................3-8 Example of control and fan wiring.......................3-9 3-1

WIRING Chapter 3 WIRING WIRING - SAFETY TE200 series units have an IP20 protective cover. Danger! Wiring must only be carried out by personnel who are qualified to work in a low voltage industrial environment. It is the user s responsibility to wire and protect the installation in accordance with current professional Standards. A suitable device ensuring electrical isolation between the equipment and the supply must be installed upstream of the unit in order to permit safe operation. Danger! Before any connection or disconnection, ensure that power and control cables or leads are isolated from voltage sources. For safety reasons, the safety earthing cable must be connected before any other connection is made during wiring and it should be the last cable to be disconnected. The safety earth is connected to the screw located on the upper part of the controller and is denoted by the symbol:! Warning! To ensure correct grounding (EMC) of the TE200S unit, make sure that it is correctly mounted on the reference ground surface (panel or bulkhead). Failing this, it is necessary to add a ground connection at most 10cms long between the earth connection and the reference ground surface. Danger! This connection, which is intended to ensure good ground continuity, can never be used to replace the safety earth connection. 3-2

WIRING CONNECTIONS Power The power terminal blocks (mains and load) are cage terminal blocks. The safety earth is connected to an M5 screw. Control The control terminal block has a screw connector. This terminal block plugs in. Fan (63A rated unit) The fan connection (for fan-cooled units) is made by means of cage terminal blocks. Connection details The terminal capacities and tightening torques to be observed are given in Table 3-1. Parameter Power & load Safety earth Control supply Terminal capacity (mm 2 ) 10 to 25 Equal to or 1.5 greater than power cross-section Tightening torque (Nm) 2 2 0.7 Table 3-1 TE200S solid state relay connection details! Warning! The cross-section of the conductors to be used must comply with Standard IEC 943. 3-3

WIRING POWER WIRING DIAGRAM (L1)(L2)(L3) R S T Recommended external high-speed fuses for thyristor protection (except for short wave infrared applications) Cable protection and mains circuit breaker Direct phase Installed by user Safety earthing screw TE200S EUROTHERM 40A/400V R (L1) S (L2) T (L3) ε U (T1) V (T2) W (T3) ON LED firing indicator 9 8 U V W Three-phase load star without neutral or closed delta Figure 3-1 Power and safety earth wiring for a load connected in star without neutral or in closed delta (3-wire configuration) 3-4

WIRING USER TERMINAL BLOCKS General introduction The user terminal blocks comprise: A control terminal block (located below the SSR, on the left side) A fan terminal block for the 63A rated unit (located in front of the control terminal block) Terminal numbers Function 7 Input for 100 to 230Vac AC control (code HAC, 9 terminal 8 is not used with this code) 8 Input for DC control (code LGC)(polarity insensitive) or 9 for 24 to 48Vac AC control (code LAC) 115V or 230V Fan supply (63A rating) Table 3-2 Function of user terminals Terminal functions are given on the label located on the front facia. 9 8 Terminal block for polarity insensitive DC control AC INPUT 9 8 24-48Vac terminal block for AC control HAC INPUT, 9 7 100-230Vac terminal block for AC control Figure 3-2 Control terminal block labels 3-5

WIRING Control terminal blocks There are two types of control terminal block depending on the input type of the SSR: 2-way terminal block for DC control and 24 to 48 Vac AC control 3-way terminal block for 100 to 230Vac AC control. LGC and LAC codes The logic signal for polarity-insensitive DC control (LGC code) or for 24 to 48 Vac AC control (LAC code) must be connected to the 2-way control connector between terminals 8 and 9. 24-48Vac or polarity insensitive DC control wires LAC or LGC control terminal block SSR front facia View from below 9 8 9 8 Figure 3-3 Control terminal block for LGC and LAC codes 3-6

WIRING HAC code The logic signal for 100 to 230Vac AC control (HAC code) must be connected to the 3-way control connector between terminals 7 and 9. Terminal 8 is not used. 100-230Vac Control wires HAC Control terminal blocks SSR front facia View from below 9 7 9 7 Terminal not used Figure 3-4 Control terminal block for HAC code 3-7

WIRING WIRING FOR CONTROL AND FAN SUPPLY Control The DC logic signal can be provided by Eurotherm 2000 series temperature controllers for example configured for DC logic outputs (see Figure 3-5). Control by AC voltage is accomplished by contacts (or triac) provided by temperature or other AC logic output controllers. These contacts (or triac) apply the AC voltage specified in the product code (24-48 Vac or 100-230 Vac) to the TE200S input configured for this voltage.! Warning! A 0.5A protective fuse must be installed in each feed wire connected to a supply phase. Contact (or triac) protection The contacts (or triac) must be protected against overvoltages at the moment of opening by an RC circuit (snubber), often integrated into temperature controllers (see Figure 3-6). Maximum value of capacitor in the protective RC circuit: 22nF for 100-230 Vac (50 Hz and 60Hz ±2Hz); 47nF for 24-48 Vac (50 Hz and 60Hz ±2Hz).! Warning! Increasing this value can lead to permanent conduction of the TE 200S. Fan (63A rated unit) The value of the fan supply voltage (115 Vac or 230 Vac) for fan-cooled units is specified in the SSR product code.! Warning! The fan connection must have a 0.5A protective fuse installed in each feed wire connected to a supply phase. 3-8

WIRING Examples of control and fan wiring To three-phase supply (via protection device) 1A fuse Eurotherm 2000 Series temperature controller Line Neutral TE200S 40A/400V EUROTHERM R (L1) S (L2) T (L3) ε EUROTHERM 2208 L U (T1) V (T2) W (T3) N E V+ Safety earth ON Logic output 1A 1B V- Thermocouple input Control signal connector (LGC) 9 8 To 3 wire three-phase load Polarity insensitive DC logic signal Figure 3-5 Example of DC signal wiring 3-9

WIRING 230Vac Mains phase Neutral * 115Vac or 230Vac mains phase (depending on the code) Neutral * To three-phase mains (via protection device) 0.5A fuse 0.5A fuse TE200S EUROTHERM 40A/400V ε R (L1) S (L2) T (L3) U (T1) V (T2) W (T3) ON Control signal connector (HAC) HAC INPUT 9 7 To 3 wire three-phase load Triac or contacts provided by a temperature or logic controller RC protective circuit 230Vac AC logic signal Fan connector Note If a second mains phase is used instead of neutral, a 0.5A fuse must be incorporated. Specified supply voltage ratings must not be exceeded. Figure 3-6 Example of wiring for 230 Vac AC signal and fan (63A) 3-10

COMMISIONING PROCEDURE Chapter 4 COMMISSIONING PROCEDURE Page COMMISSIONING PROCEDURE - SAFETY...............4-2 CHECKING CHARACTERISTICS........................4-3 Load current........................................4-3 Supply voltage......................................4-3 Fan supply voltage (63A rated unit)......................4-4 Control signals......................................4-4 POWERING UP........................................4-4 4-1

COMMISIONING PROCEDURE Chapter 4 COMMISSIONING PROCEDURE COMMISSIONING PROCEDURE - SAFETY! Important! Eurotherm cannot be held responsible for any damage to persons or property or any financial loss or costs arising from incorrect use of the product or failure to observe the instructions contained in this manual. It is therefore the user s responsibility to ensure, before commissioning the unit, that all the nominal ratings of the unit are compatible with the conditions of use and the installation. Danger! A thyristor is not an isolating device. Touching a load terminal even with a zero load current is as dangerous as touching live mains. Only personnel qualified and trained to work with low voltage electrical equipment in an industrial environment should have access to the interior of the unit. Access to internal components of the unit is prohibited to users who are not authorised to work in an industrial low voltage electrical environment. The temperature of the heatsink may exceed 100 C. Avoid all contact, even occasional, with the heatsink when the SSR is operational. The heatsink remains hot for around 15mins after the unit has been switched off. 4-2

COMMISIONING PROCEDURE CHECKING THE CHARACTERISTICS Load current The maximum load current must be less than or equal to the value of the nominal current of the SSR, taking into account the load and power supply variations. For the total power (P) of a three-phase load and for the line-to-line voltage VL, the current is: P I = ---------------- 3 x VL In order to take supply voltage and load value tolerances into account, allow a minimum 20% safety margin between the result of the calculation given above and the nominal current of the SSR.! Warning! The nominal current of the SSR (I N ) must be greater than or equal to 1.2 x I. If three identical loads are configured in closed delta, the current of each phase of the SSR is 3 times greater than the current in each branch of the load. Supply voltage The nominal value of the TE200S voltage must be greater than or equal to the line-to-line voltage of the supply used. 4-3

COMMISIONING PROCEDURE Fan supply voltage (63A rated unit) For 63A rated fan-cooled SSRs, the fan must be provided with a 115Vac or 230Vac supply. The fan supply voltage is set at the factory, depending on the product code ordered. Control signals Configuration of the input type required by the user is also set at the factory, depending on the product code ordered. Check that the label on the front facia corresponds to the control setup: Terminals 8 and 9 No legend - DC logic input AC Input legend:- 24 to 48Vac input HAC Input legend:- 100 to 230Vac input POWERING UP TE200S series SSRs are ready to operate correctly immediately after installation and wiring in accordance with this user manual. After checking that the nominal parameters of the SSR (voltage, current, input signal) are compatible with those of the installation, apply volts to the SSR. Check that the current in each phase of the SSR is equal to 0 in the absence of the control signal. Make sure that the r.m.s. current in each phase does not exceed the nominal rating when the control signal is present. 4-4

MAINTENANCE Chapter 5 MAINTENANCE Page FUSES...............................................5-2 Thyristor protection..................................5-2 Protection for fan connection (63A rated unit)..............5-4 SERVICING...........................................5-5 TOOLS...............................................5-5 5-1

MAINTENANCE Chapter 5 MAINTENANCE Danger! The SSR must be maintained by personnel qualified and trained to work with low voltage electrical equipment in an industrial environment. The user s installation must be protected upstream (non high-speed fuses, thermal or electromagnetic circuit breaker, suitable fuse-isolator) and must comply with current standards. FUSES Thyristor protection Thyristors in the TE200S series of SSRs are protected in the following way: by external high-speed fuses against overcurrents (except for short-wave infrared applications); these fuses must be ordered separately; by RC snubbers and internal MOVs (varistors) which protect against fast voltage transient and transient overvoltages. Danger! High-speed fuses are used only for the internal protection of thyristors against large amplitude overloads. Under no circumstances should these fuses be used to protect the installation.! Warning! For the use of high-speed fuses in short-wave infrared applications, please contact Eurotherm Controls.! Warning! For resistive loads (except short-wave infrared applications) the use of any fuses other than those recommended for thyristor protection will invalidate the guarantee. 5-2

MAINTENANCE To protect the thyristors in the TE200S, depending on the wiring configuration the following combinations may be used: Two single-phase fuse and fuseholder assemblies installed in the controlled phases or One three-phase fuse and fuseholder assembly installed between the TE200S SSR and the cable protection and mains circuit breaker; in the direct phase it is possible to install a solid link instead of a fuse. References for the fuse and fuseholder assemblies and for spare fuses are given in the following tables. Nominal Spare fuse Code current References: Fuse+fuseholder Dimensions TE200S Fuse Eurotherm Ferraz Assembly (mm) 16A 20A CH 260024 K330013 FU1038/16A/00 81 x 17.5 x 68 25A 30A CH 260034 M330015 FU1038/25A/00 81 x 17.5 x 68 40A 50A CH 330054 B093910 FU1451/40A/00 95 x 26 x 86 50A 63A CS 173087U063 T094823 FU2258/50A/00 140 x 35 x 90 63A 80A CS 173246U080 W076310 FU2760/63A/00 150 x 38 x 107 Table 5-1 Recommended high-speed fuses for thyristor protection Single-phase fuseholders. Nominal Spare fuse Code current References: Fuse+fuseholder Dimensions TE200S Fuse Eurotherm Ferraz Assembly (mm) 16A 20A CH 260024 K330013 FU3038/16A/00 81 x 52.5 x 68 25A 30A CH 260034 M330015 FU3038/25A/00 81 x 52.5 x 68 40A 50A CH 330054 B093910 FU3451/40A/00 95 x 79 x 86 50A 63A CS 173087U063 T094823 FU3258/50A/00 140 x 108 x 90 63A 80A CS 173246U080 W076310 FU3760/63A/00 150 x 114 x 107 Table 5-2 Recommended high-speed fuses for thyristor protection Three-phase fuseholders with three fuses. Maximum operating voltage for fuses: 500Vac (line-to-line). 5-3

MAINTENANCE Protection for fan connection (63A rated unit) A protection fuse for the fan connection (63A nominal current) must be installed in each conductor connected to a supply phase. Line-to-line 0.5A fuse 6.3 x 32mm Fuse-holder Fuse-isolator voltage isolator assembly dimensions (max.) (mm) Reference Reference Eurotherm Ferraz Eurotherm 250V CS174290U0A5 J084303 CP174293 63 x 15 x 52 Table 5-3 Recommended protection fuse for fan connection The same fuse must be installed to protect the control circuit connection if used with 24 to 48Vac and 100 to 230Vac inputs. 5-4

MAINTENANCE SERVICING TE200S SSRs must be mounted with the heatsink positioned vertically, with no obstructions above or below which could inhibit or impede airflow.! Warning! If several units are mounted in the same cabinet, they should be arranged in such a way that air expelled from one cannot be drawn into the unit located above it. In order to ensure correct cooling of the unit, users are advised, depending on the degree of environmental pollution, to regularly clean the heatsink and (for 63A rated units) the protective fan guard. Danger! Cleaning should only be carried out with the supply disconnected and at least 15 minutes after it has ceased operating. Every six months check that the screws of the power and safety earth cables are correctly tightened (see Wiring page 3-3). TOOLS Task Safety earth wiring Power wiring 0.5 x 4 Fan (63A rated unit) 0.5 x 2.5 and control wiring Flat-blade screwdriver (mm) Hex key HEX 8 (M5) Table 5-4 Tools 5-5

ADDENDUM to User Manuals TE200S Part N HA175921 ENG TE200A Part N HA175773 ENG MAXIMUM CURRENT and SHORT WAVE INFRARED APPLICATIONS MAXIMUM CURRENT In order to take into account supply voltage variations and heating element resistance dispersion (all types of heating elements including short wave infrared), a 0.8 safety coefficient must be used on the thyristor unit current rating to determine the maximum value of the load nominal current which the unit can safely control. SHORT WAVE INFRARED (SWIR) APPLICATIONS Applications using short wave infrared heaters in Single Cycle, Fast Cycle or Advanced Single Cycle are reserved to 16 A, 25 A and 40 A current rating. With a safety coefficient of 0.8 the maximum current for SWIR which can be controlled is: Current rating SWIR maximum controlled current 16 A 230 V and 400 V : 13 A 25 A 230 V : 16 A, 400 V : 13 A With Special 601 230 V and 400 V : 20 A 40 A, 50 A and 63 A 230 V : 28 A, 400 V : 25 A Copyright Eurotherm Automation S.A. 1998 All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Automation SA. Part N : HA176063 ENG - issue 1.2-05/01

EUROTHERM CONTROLS LIMITED UK SALES OFFICE Eurotherm Controls Limited Faraday Close, Durrington Worthing West Sussex BN13 3PL Telephone Sales: (01903) 695888 Technical: (01903) 695777 Service: (01903) 695444 Fax (01903) 695666 Sales and support in over 30 countries worldwide For countries not listed enquiries/orders to: Eurotherm Controls Limited Export Dept., Faraday Close, Durrington, Worthing West Sussex, BN13 3PL Telephone (01903) 268500 Fax (01903) 265982