Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Similar documents
Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Three-Phase Transformer Demagnetizer DEM60

Winding Ohmmeter & Tap Changer Test Set RMO10TW

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

Three-Phase Winding Ohmmeter TWA25K

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Winding Ohmmeter RMO-TW

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Winding Ohmmeter RMO-TW

Motor Winding Ohmmeter RMO50M

RMO-A series Micro Ohmmeters

Three-Phase Transformer Turns Ratio Tester TRT03B

Three-Phase Transformer Turns Ratio Tester TRT03C

True Three-Phase Transformer Turns Ratio Tester TRT30A

True Three-Phase Transformer Turns Ratio Tester TRT63B

True Three-Phase Transformer Turns Ratio Tester TRT30A

True Three-Phase Transformer Turns Ratio Tester TRT40A

True Three-Phase Transformer Turns Ratio Tester TRT63

Three-Phase Transformer Turns Ratio Tester TRT03

True Three-Phase Transformer Turns Ratio Tester TRT4x

True Three-Phase Transformer Turns Ratio Tester TRT400

True Three-Phase Transformer Turns Ratio Tester TRT4x

True Three-Phase Transformer Turns Ratio Tester TRT3x

TRAX Transformer and Substation Test System

TRAX Transformer and Substation Test System

TRAX Transformer and Substation Test System

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

Product Catalog 2014

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

FRAX Series Sweep Frequency Response Analyzers

TRM-203/403 transformer resistance meters

MIKO-9(A) MIKO-8M(A) MIKO-7M(A)

Importance of Transformer Demagnetization

Automatic Transformer Winding Analyser

Demagnetization of Power Transformers Following a DC Resistance Testing

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

Advanced Test Equipment Rentals ATEC (2832)

QUINT-PS/ 3AC/24DC/10

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

RMO500 M I C R O O H M M E T E R

CT Analyzer. Revolution in current transformer testing and calibration

TRM-203/TRM-403. transformer resistance meters. Vanguard Instruments Company, Inc.

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

World-Class Accuracy & Measurement Range (40 Conventional Models)

QUINT-PS/ 3AC/24DC/40

SVERKER 900 Relay and Substation Test System

The measurement of winding resistance is useful in detecting a number of types of fault in a transformer. Malfunctioning tap changer mechanisms

QUINT-PS AC/24DC/40

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

CP-T range Product group picture

T 1000 PLUS Secondary Injection Relay Test Set

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Power supply CP-E 24/2.5

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CP-E range Benefits and advantages

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

02/11/2015

ODEN AT Primary Current Injection Test System

QUINT-PS/ 1AC/24DC/20

METRAClip87 and 88 Clamp Multimeters

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Advanced Test Equipment Rentals ATEC (2832)

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power supply CP-E 24/20.0

TORKEL 900-series Battery Load Unit

High precision measurement system for current and voltage IHC-A/B-RM01/03

PCT200 SERIES CT/PT TEST SYSTEM USER MANUAL

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

FRAX Series Sweep Frequency Response Analyzers

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Smart Power Relay E I...

Primary switch mode power supplies Product group picture

PQube 3 Specifications

High-precision portable RESISTANCE METER

CP-T range Benefits and advantages

High-precision process calibrator Model CED7000

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

MINI-PS AC/2X15DC/1

Wide-band Models from DC to 100 MHz

1587/1577 Insulation Multimeters

TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

TM1600. Circuit Breaker Analyzer System

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

HAWK5000 Operators Manual

CPC 100. Multi-functional primary test system for substation commissioning and maintenance

TORKEL 900-series Battery Load Unit

Transcription:

Tap Changer Analyzer & Winding Ohmmeter RMO60TD Test current 5 ma 60 A DC Rapid automatic demagnetization AC Current monitoring channel Lightweight 13 kg Measuring range 0,1-2 k Two voltage sense channels Extremely quick measurement Automatic discharge circuit Built-in Tap Changer Control Unit High DC current tap changer analyzer & resistance meter for transformers Description The Tap Changer Analyzer & Winding Ohmmeter RMO60TD is designed for resistor type on-load tap changer analysis and for resistance measurement of inductive test objects. RMO60TD generates true DC ripple free current. Both injection of current and discharge of energy from the inductance are automatically regulated. RMO60TD injects current with a voltage as high as 60 V. This ensures that the duration of test is as short as possible, and that the desired test current is reached faster. Two independent channels enable testing of two series windings, or primary and secondary windings. There is enough memory within RMO60TD instrument to store 500 measurements (EEPROM memory). All measurements are time and date stamped. The set is equipped with thermal and overcurrent protection. The RMO60TD has very high ability to cancel electrostatic and electromagnetic interference in HV electric fields. It is achieved by very efficient filtration. The filtration is made utilizing proprietary hardware and software. On Load Tap Changers The RMO60TD can be used to measure winding resistance of individual taps of a power transformer s tap changer. It can also check whether the on-load tap changer (OLTC) switches without an interruption. The moment a tap position is changed from one tap to another, the device detects a sudden, very short drop of the current. A properly working tap changer results differ from a malfunctioning one. This is obvious if an interruption during the change occurs, by the magnitude of the current ripple, the value of measured resistances, and also by different transition times. The instrument displays resistance value and ripple in percents. The Tap Changer Control Unit allows the operator to control the Tap Changer operation box from the RMO60TD instrument. For additional diagnostic functions, our software DV-Win should be used.

Demagnetization Feature After a DC current test, such as a winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remanent magnetism). Also, when disconnecting a transformer from service, some amount of magnetic flux trapped in the core could be present. The remanent magnetism can cause various problems such as erroneous diagnostic electrical measurements on a transformer, or an Inrush current at start-up of power transformer, or incorrect operation of protective relays due to magnetized CT cores. To eliminate this source of potential problems, demagnetization should be performed. When a discharging process has terminated, the RMO60TD can perform fully automatic demagnetization. Demagnetizing magnetic core of a transformer requires alternating current applied with decreasing magnitude down to zero. The RMO60TD provides this alternating current by internally changing the polarity of a controlled DC current. During the demagnetization process the RMO60TD supplies current at decreasing magnitude for each step, following a proprietary developed program. DV-Win Using DV-Win software, instrument can be operated and controlled from a PC, and results are obtained directly at a PC. The DV-Win software allows results to be arranged in an Excel spreadsheet, which can be shown later as a diagram and printed as a report, or exported in ASCII format. This software provides more detailed condition assessment of an OLTC (tap changer) by recording the graph which represents dynamic resistance during the tap change and motor current. The DV-Win measures OLTC transition time, an important characteristic for condition assessment. The standard interface is USB and optional RS232. AC Current monitoring channel AC current monitoring channel is intended for monitoring and recording the OLTC mechanicaldrive motor-current during tap changer operation. The motor current waveform is also printed on the DV Win generated graph, and can help in detecting OLTC mechanical problems. An AC current clamp is provided.

Typical application Typical application of RMO60TD is measuring the resistance of: Power transformers On-Load Tap Changers Generators and electrical motors High-current busbar joints Cable splices Accessories Included DV-Win PC software Built-in Tap Changer Control Unit Tap Changer Control cable set 5m Mains power cable Ground (PE) cable Recommended Current cables 2 x 10 m 10 mm 2 and Sense cables 2 x 10 m with TTA clamps Current connection cable 1 x 5 m 10 mm 2 with TTA clamps Sense cables 2 x 10 m with TTA clamps Current clamp 20/200 A Cable bag Optional Built-in thermal printer 80 mm (in bigger plastic case) Test shunt 150 A / 150 mv Current cables 2 x 15 m 10 mm 2 with TTA clamps Sense cables 2 x 15 m with TTA clamps Cable plastic case Current cables and sense cables with TTA clamps Voltage sense cables with TTA clamps Current connection cable Current clamp Shunt Cable bag

Connecting a Test Object to RMO60TD The RMO60TD should be turned off, connection between RMO60TD and the test object is such that the measuring cables from the "Voltage Sense" sockets are attached as close as possible to the measured resistance, while they are connected between the current feeding cables. That way, resistance of cables and clamps is almost completely excluded from the resistance measured. The figure to the right shows simultaneous testing of both windings (high and low) on a singlephase transformer. In such a way, it is possible to speed up the measurement when two channels are used to test both windings Testing of a Delta-delta winding resistance is usually a very time consuming procedure. This is because the two windings represent two closed loop inductors. When energy is brought into the inductors, this energy (in the form of D.C. current) continually circulates within each winding. To test this configuration quickly, both high and low sides should be connected in series with the current source of a Transformer Ohmmeter. By having these two windings in opposing polarity, the internal circulating currents settle very quickly to obtain a balance, and discharge with the same speed. Even if only one side of the transformer needs to be tested, connecting both high and low windings in series will speed up the test considerably. Using RMO60TD s Tap Changer menu, the power transformer winding resistance of individual tap positions can be measured. Also, you can check whether the on-load tap changer switches without an interruption. The RMO60TD current output injects a constant current into a power transformer. This current and voltage value is measured, and the winding resistance is calculated.

Technical data 1 Mains Power Supply - Connection according to IEC/EN60320-1; C320 - Voltage 90 V 264 V AC, 50 / 60 Hz, single-phase - Power consumption 2250 VA - Fuse 15 A / 250 V, type F 2 Output data - Test current 5 ma DC 25 A DC - Measuring range / Resolution 0,1-999,9 0,1 1,000 m - 9,999 m 1 10,00 m - 99,99 m 10 100,0 m - 999,9 m 0,1 m 1,000-99,99 10 m 100,0-999,9 0,1 1000-2000 1 - Typical accuracy ± (0,1 % rdg + 0,1 % FS) 3 AC Current monitoring channel - Current monitoring resolution: 0,1 ms - Amplitude resolution: 16 bit 4 - Current clamp meter specifications: - Nominal current: 20 A r.m.s - Measuring range: 5 ma - 30 A max - Accuracy: 20 A (< 1 khz): ± (1 % of rdg + 2 ma) 20 A (1 to 20 khz): ± (3 % of rdg + 2 ma) 5 Environmental conditions - Operating temperature -10 o C - +55 o C / 14 F - +131 F - Storage and transportation -25 o C - +70 o C / -13 F - +158 F - Humidity 5 % - 95 % relative humidity, non condensing 6 Dimensions and Weight - Dimensions 450 mm x 175 mm x 320 mm 17,72 in x 6,89 in x 12,6 in (W x H x D) - Weight 13 kg / 28,6 lb 7 Warranty three years 8 Applicable Standards - Installation/overvoltage: category II - Pollution: degree 2 - Safety LVD 2006/95/EC, (CE Conform) Standard EN 61010-1 - EMC Directive 2004/108/EC (CE Conform) Standard EN 61326:2006 *All specifications herein are valid at ambient temperature of + 25 C and standard accessories. *Specifications are subject to change without notice.