Winding Ohmmeter RMO-TW

Similar documents
Winding Ohmmeter RMO-TW

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Three-Phase Winding Ohmmeter TWA25K

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Three-Phase Transformer Demagnetizer DEM60

Winding Ohmmeter & Tap Changer Test Set RMO10TW

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

RMO-A series Micro Ohmmeters

Motor Winding Ohmmeter RMO50M

Three-Phase Transformer Turns Ratio Tester TRT03B

True Three-Phase Transformer Turns Ratio Tester TRT30A

Three-Phase Transformer Turns Ratio Tester TRT03C

True Three-Phase Transformer Turns Ratio Tester TRT63B

True Three-Phase Transformer Turns Ratio Tester TRT30A

True Three-Phase Transformer Turns Ratio Tester TRT40A

True Three-Phase Transformer Turns Ratio Tester TRT63

True Three-Phase Transformer Turns Ratio Tester TRT400

Three-Phase Transformer Turns Ratio Tester TRT03

True Three-Phase Transformer Turns Ratio Tester TRT4x

True Three-Phase Transformer Turns Ratio Tester TRT3x

True Three-Phase Transformer Turns Ratio Tester TRT4x

Product Catalog 2014

TRM-203/403 transformer resistance meters

SCOPE TRM 25 TRM 25+ Transformer Winding Resistance Meter. The most advanced Transformer Winding Resistance Meter injects up to 25A DC...

RMO500 M I C R O O H M M E T E R

TRAX Transformer and Substation Test System

N. TEST TEST DESCRIPTION

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

TRAX Transformer and Substation Test System

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

TRAX Transformer and Substation Test System

Importance of Transformer Demagnetization

Automatic Transformer Winding Analyser

Power supply CP-E 24/2.5

TRM-203/TRM-403. transformer resistance meters. Vanguard Instruments Company, Inc.

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

N. TEST TEST DESCRIPTION

TORKEL 900-series Battery Load Unit

TORKEL 900-series Battery Load Unit

MIKO-9(A) MIKO-8M(A) MIKO-7M(A)

Power supply CP-E 24/20.0

Power supply CP-E 24/0.75

High-precision portable RESISTANCE METER

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

Power supply CP-E 24/2.5

ODEN AT Primary Current Injection Test System

02/11/2015

02/11/2015

Advanced Test Equipment Rentals ATEC (2832)

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

DC Resistance Meters 2840 Series

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-D 24/4.2 Primary switch mode power supply

RMA42. Technical Information

Electronic timer CT-SDS.22

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

DM-45 Digital Multimeter

FRAX Series Sweep Frequency Response Analyzers

Electronic timer CT-MFS.21

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

High-precision process calibrator Model CED7000

02/11/2015

Electronic timer CT-TGD.22

OM 16. Onsite micro-ohmmeter up to 10 A

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Signet 9900 Transmitter

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System

MIT510, MIT520 and MIT1020

Power supply CP-D 24/1.3

Family 400 meters Rel /04/2007

DC Electronic Loads 8500 Series

CP-T range Product group picture

MIT510/2, MIT520/2 and MIT1020/2

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Series AMEPR60-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Switching power supplies CP range, Linear power supplies CP-L range. Content

Electronic timer CT-SDD.22

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

02/11/2015

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

General Specifications

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Primary switch mode power supplies Product group picture

Installation / Monitoring Technique

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

TM1600. Circuit Breaker Analyzer System

Power supply CP-T 24/10.0 Primary switch mode power supply

METRAClip87 and 88 Clamp Multimeters

Transcription:

Winding Ohmmeter RMO-TW Three resistance measurement channels One temperature measurement channel Accuracy 0,1 % Lightweight On-load tap changer verification Automatic resistance measurement for the Heat Run test Rapid automatic demagnetization Automatic discharge circuit Resistance measurement of transformers, rotary machines and non-inductive objects Four models: RMO10TW, RMO20TW, RMO30TW, RMO50TW Description The Winding Ohmmeter of the RMO-TW series is designed for winding resistance measurement of inductive objects. The RMO-TW instrument is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TW instrument is accurate (0,1%), powerful (up to 50 A) and lightweight. It generates a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TW instrument can perform a simple, quick and reliable transformer on-load tap changer verification. This instrument enables measurements of a winding resistance in every tap position of an on-load tap changer without discharging between the tests. Problems with switching of the OLTC, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD display. Application The list of the instrument application includes: Three-channel winding resistance measurement, which enables simultaneous winding resistance measurement of up to three windings on a single phase Detection of interruptions during the operation of on-load tap changers (OLTC), performed on a single phase Heat Run test, which enables obtaining the Hot Spot temperature along with resistance graph during the cooling process 1

Connecting RMO-TW to Transformer The RMO-TW has three separate resistance measurement channels, which enable simultaneous measurement of the primary, secondary and tertiary winding on the same phase, as presented in the figure above. This significantly speeds up the measurement and reduces the total transformer testing time. At the same time, by saturating the magnetic core through the HV and LV windings the stabilization time and subsequently the total testing time is reduced even more. Simultaneous Three-Channel Winding Resistance Measurement The RMO-TW injects the current with a voltage value as high as 55 V. This ensures that the magnetic core is saturated quickly and duration of the test is as short as possible. The three independent channels enable simultaneous testing of three windings in series primary, secondary and tertiary windings. There is enough memory within the RMO-TW instrument to store 1 000 measurements. All measurements are time and date stamped. The instrument is equipped with thermal and overcurrent protection. The RMO-TW has very high ability to cancel electrostatic and electromagnetic interference that exists in HV electric fields. It is achieved by a proprietary filtration solution applied to both, the hardware construction and the application software implementation. A special mode is provided for the resistance measurement in multiple deenergized tap changer (DETC) positions. Resistance Testing in Multiple Tap Changer Positions The winding resistance of all tap changer positions in one phase can be measured as part of a single test, without discharging between measurements. Different test modes are provided for on-load tap changers (OLTC) and de-energized tap changers (DETC). The instrument detects interruptions during the operation of on-load tap changers and produces a warning message to the operator. Automatic_Transformer Demagnetization After a DC current test, such as a winding resistance measurement, the magnetic core of a power or a measurement transformer may be magnetized. Also, when disconnecting a transformer from a service, some amount of magnetic flux trapped in the core could be present. The remnant magnetism can cause various problems such as erroneous measurements on a transformer, or an inrush current at start-up of a power transformer, or an incorrect operation of the protective relays due to the magnetized CT cores. To eliminate this source of potential problems, demagnetization should be performed. When the discharging process has been completed, the RMO-TW can perform fully automatic demagnetization. Demagnetizing the magnetic core of a transformer requires alternating current applied with decreasing magnitude down to zero. The RMO-TW provides this alternating current by internally changing the polarity of a controlled DC current. 2

DV-Win Software The DV-Win application software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. The software provides additional OLTC (tap changer) verification option by recording the test current during the transition. The standard interface is USB. RS232 is optional. Heat Run Test Application The DV-Win application software has an additional Heat Run temperature/resistance extrapolation feature. After the transformer heating is switched off, the RMO-TW is immediately connected to up to three transformer windings and the timer is started. The winding resistance is measured at regular time intervals. This information is used to automatically extrapolate the values of temperature and resistance at the moment when the transformer was switched off. 3

Technical Data Winding Resistance Measurement Test currents: 5 ma 10 A DC for RMO10TW 5 ma 20 A DC for RMO20TW 5 ma 30 A DC for RMO30TW 5 ma 50 A DC for RMO50TW Output voltage: up to 55 V DC Measurement range: 0,1 μω - 10 kω Typical accuracy: ±(0,1% rdg + 0,1% F.S.) for 0,1 μω-1,999 kω range ±(0,2% rdg + 0,1% F.S.) for 2 kω - 10 kω range Resolution 0,1 μω 999,9 μω: 0,1 μω 1,000 mω 9,999 mω: 1 μω 10,00 mω 99,99 mω: 10 μω 100,0 mω 999,9 mω: 0,1 mω 1,000 Ω 9,999 Ω: 1 mω 10,00 Ω - 99,99 Ω: 10 mω 100,0 Ω 999,9 Ω: 0,1 Ω 1,000 kω 9,999 kω: 1 Ω Data Storage 1 000 internal memory positions Printer (optional) Thermal printer Paper width 80 mm OLTC Dynamic Resistance Measurement Sampling rate: 4 ms Automatic open circuit detection and warning Transition current ripple measurement Transition time measurement using DV-Win software Timing measurement of different transition changes using DV-Win graph analysis tool Temperature Measurement One temperature measurement channel Thermometer Pt100-50 ºC +180 ºC / -58 ºF +356 ºF 50 mm x 6 mm Computer Interface USB Optional: RS232 Warranty Three years Environmental Conditions Operating temperature: - 10 ºC to + 55 ºC / + 14 ºF to + 131 ºF Storage & transportation: - 40 ºC to + 70 ºC / - 40 ºF to + 158 ºF Humidity 5 % - 95 % relative humidity, non condensing Dimensions and Weight Device Weight Dimensions (WxHxD) RMO10TW RMO20TW RMO30TW RMO50TW 8 kg / 17.6 lbs 8.5 kg / 18.7 lbs 205 x 287 x 410 mm 8.1 x 11.3 x 16.4 in 205 x 287 x 410 mm 8.1 x 11.3 x 16.4 in Mains Power Supply Connection according to IEC/EN60320-1; UL498, CSA 22.2 Mains supply: 90 V - 264 V AC Frequency: 50 / 60 Hz Mains supply voltage fluctuations up to ±10 % of the nominal voltage Input power: 2 250 VA Fuse 15 A / 250 V, type F, not user replaceable Applicable Standards Installation/overvoltage: category II Pollution: degree 2 Low voltage directive: Directive 2014/35/EU (CE conform); Applicable standards, for a class I instrument, pollution degree 2, installation category II: IEC EN61010-1 EMC: Directive 2014/30/EU (CE Conform) Applicable standard EN 61326-1 Safety: CAN/CSA-C22.2 No. 61010-1, 2nd edition, including Amendment 1 All specifications herein are valid at ambient temperature of + 25 C and recommended accessories. Specifications are subject to change without notice. Specifications are valid if the instrument is used with the recommended set of accessories. 4

Current and Sense cables with TTA clamps Voltage Sense cables with TTA clamps Device bag Cable plastic case Current connection cable with TTA clamps Cable bag Transport case Test shunt Order Info 5

Instrument with Included accessories Winding Ohmmeter RMO-TW DV-Win PC software including USB cable Mains Power cable Ground (PE) cable Recommended Current cables 2 x 10 m 10 mm 2 (32.8 ft, 7 AWG) and Sense cables 2 x 10 m (32.8 ft) with TTA clamps* Current cables 2 x 10 m 2,5 mm 2 (32.8 ft, 13 AWG) and Sense cables 2 x 10 m (32.8 ft) with TTA clamps** Sense cables 2 x 10 m (32.8 ft) with TTA clamps Current connection cable 1 x 5 m 10 mm 2 (16.4 ft, 7 AWG) with TTA clamps* Current connection cable 1 x 5 m 6 mm 2 (16.4 ft, 9 AWG) with TTA clamps** Transport case *Recommended for RMO30TW and RMO50TW ** Recommended for RMO10TW and RMO20TW Optional Test shunt 150 A / 150 mv Thermal printer 80 mm (3.15 in) (built-in) Cable plastic case small size Cable plastic case medium size Cable bag Current cables 2 x 15 m 10 mm 2 (49.2 ft, 7 AWG) and Sense cables 2 x 15 m (49.2 ft) with TTA clamps Current cables 2 x 15 m 2,5 mm 2 (49.2 ft, 13 AWG) and Sense cables 2 x 15 m (49.2 ft) with TTA clamps Current cables 2 x 20 m 16 mm 2 (65.6 ft, 5 AWG) and Sense cables 2 x 20 m (65.6 ft) with TTA clamps Current cables 2 x 20 m 2,5 mm 2 (65.6 ft, 13 AWG) and Sense cables 2 x 20 m (65.6 ft) with TTA clamps Sense cables 2 x 15 m (49.2 ft) with TTA clamps Sense cables 2 x 20 m (65.6 ft) with TTA clamps Current connection cable 1 x 12 m 10 mm 2 (39.4 ft, 5 AWG) with TTA clamps Current connection cable 1 x 12m 6 mm 2 (39.4.4 ft, 9 AWG) with TTA clamps Temperature sensor 1 x 50 mm (1.97 in) + 5/10/15 m (16.4/32.8/49.2 ft) Article No RMOXXTW-N-00 Article No CS-10-10LMWC CS-10-02BPWC S2-10-02BPWC CX-05-102XWC CX-05-062XWC HARD-CASE-ME Article No SHUNT-150-MK PRINT-080-00 CABLE-CAS-01 CABLE-CAS-02 CABLE-BAG-00 CS-15-10LMXC CS-15-02BPWC CS-20-10LMXC CS-20-02BPWC S2-15-02BPWC S2-20-02BPWC CX-12-102XWC CX-12-062XWC TEMP1-050-XX IBEKO Power AB Contact Stockholmsvägen 18 Phone: +46 70 0925 000 181 50 Lidingö, Sweden E-mail: sales@dv-power.com 6