Design, Fabrication and Performance of the 10-inch TOM HPD

Similar documents
The HPD DETECTOR. Michele Giunta. VLVnT Workshop "Technical Aspects of a Very Large Volume Neutrino Telescope in the Mediterranean Sea"

Pixel hybrid photon detectors

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors

Production of HPDs for the LHCb RICH Detectors

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

High collection efficiency MCPs for photon counting detectors

Introduction Test results standard tests Test results extended tests Conclusions

Stato del progetto RICH di LHCb. CSN1 Lecce, 24 settembre 2003

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Development of Photon Detectors at UC Davis Daniel Ferenc Eckart Lorenz Alvin Laille Physics Department, University of California Davis

PoS(PD07)035. Development of 144 Multi-Anode HPD for Belle Aerogel RICH Photon Detector

Large Area Hybrid Photodiodes

Radiation transducer. ** Modern electronic detectors: Taking the dark current into account, S = kp + bkgnd over the dynamic range.

Electron-Bombarded CMOS

Status of the large area MCP-PMT in China

event physics experiments

Low Noise Photo-Detectors for Application in Nuclear Imaging

The Argonne 6cm MCP-PMT System. Bob Wagner for Argonne LAPPD Collaboration ANNIE Collaboration Meeting Monday 27 Oct 2014

Performance of the MCP-PMTs of the TOP counter in the first beam operation of the Belle II experiment

hybrides à pixels et à leurs applications

Measurement of the FD camera light collection efficiency and uniformity

Optical Module in KM3NeT

Performance of 8-stage Multianode Photomultipliers

Development of the first prototypes of Silicon PhotoMultiplier (SiPM) at ITC-irst

O.H.W. Siegmund, Experimental Astrophysics Group, Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720

Applications of a Pixellated Detection System to Digital Mammography

Timing and cross-talk properties of BURLE multi-channel MCP PMTs

Photoelectric effect

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

Design and Simulation of a Silicon Photomultiplier Array for Space Experiments

Development of New Large-Area Photosensors in the USA

Institute for Particle and Nuclear Studies, High Energy Accelerator Research Organization 1-1 Oho, Tsukuba, Ibaraki , Japan

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Recent Developments in Ultra-High Speed and Large Area Photomultiplier Tubes

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

Light Collection. Plastic light guides

Total Absorption Dual Readout Calorimetry R&D

Working Towards Large Area, Picosecond-Level Photodetectors

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

arxiv: v1 [astro-ph.im] 19 Nov 2014

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

Performance of Microchannel Plates Fabricated Using Atomic Layer Deposition

Advancement in development of photomultipliers dedicated to new scintillators studies.

Fast Drift CRID with GEM*

CHAPTER 11 HPD (Hybrid Photo-Detector)

Performance of High Pixel Density Multi-anode Microchannel Plate Photomultiplier tubes

Advances in microchannel plate detectors for UV/visible Astronomy

PoS(PhotoDet 2012)058

Trigger Rate Dependence and Gas Mixture of MRPC for the LEPS2 Experiment at SPring-8

The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode with Improved Spectrometric Performance

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators

Simulation studies of a novel, charge sharing, multi-anode MCP detector

Extension of the MCP-PMT lifetime

INFN Milano Bicocca. Andrea Giachero Claudio Gotti Matteo Maino Gianluigi Pessina. Alessandro Baù Andrea Passerini (partial support)

Characterisation of Hybrid Pixel Detectors with capacitive charge division

Test results on hybrid photodiodes

Development of New Photosensors for Huge Detectors

Characterization of 18mm Round and 50mm Square MCP-PMTs

High Performance. Image Intensifiers

Basic Components of Spectroscopic. Instrumentation

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

A BaF2 calorimeter for Mu2e-II

R & D for Aerogel RICH

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

Wavelength-dependent resolution and electron energy distribution measurements of image intensifiers

The on-line detectors of the beam delivery system for the Centro Nazionale di Adroterapia Oncologica(CNAO)

RD51 ANNUAL REPORT WG1 - Technological Aspects and Development of New Detector Structures

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

Improvement of the MCP-PMT performance under a high count rate

IceCube. Flasher Board. Engineering Requirements Document (ERD)

Guide to SPEX Optical Spectrometer

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Charge Loss Between Contacts Of CdZnTe Pixel Detectors

Major Fabrication Steps in MOS Process Flow

Development of an atmospheric Cherenkov era for the CANGAROO-III experiment

The Multigap RPC: The Time-of-Flight Detector for the ALICE experiment

P ILC A. Calcaterra (Resp.), L. Daniello (Tecn.), R. de Sangro, G. Finocchiaro, P. Patteri, M. Piccolo, M. Rama

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

X-ray Detectors: What are the Needs?

MCP photon detectors studies for the TORCH detector

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Deliverable Report. CERN pixel beam telescope for the PS

High granularity scintillating fiber trackers based on Silicon Photomultiplier

Charge Sharing Effect on 600 µm Pitch Pixelated CZT Detector for Imaging Applications *

Scintillation Counters

Fundamentals of CMOS Image Sensors

Status of the PRad Experiment (E )

Silicon Carbide Solid-State Photomultiplier for UV Light Detection

LaBr 3 :Ce, the latest crystal for nuclear medicine

SiPMs as detectors of Cherenkov photons

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa

PMF the front end electronic for the ALFA detector

Use of a Hybrid Photo Detector (HPD) in the MAGIC micro power LIDAR system

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Properties of a Detector

STUDY OF NEW FNAL-NICADD EXTRUDED SCINTILLATOR AS ACTIVE MEDIA OF LARGE EMCAL OF ALICE AT LHC

Development of Integration-Type Silicon-On-Insulator Monolithic Pixel. Detectors by Using a Float Zone Silicon

arxiv:hep-ex/ v1 19 Apr 2002

Transcription:

1 Design, Fabrication and Performance of the 10-inch TOM HPD A. Braem a,e.chesi a, C. Joram a,j.séguinot b, P. Weilhammer a M. Giunta c,n.malakhov c, A. Menzione c,r.pegna d,a.piccioli d, F. Raffaelli c, G. Sartori e a CERN, EP Division, Geneva, Switzerland b Collège de France, Paris, France c INFN Sezione di Pisa, Italy d Dipartimento di Fisica, Universitá di Siena and INFN Sezione di Pisa, Italy e INFN Sezione di Padova, Italy The first sealed TOM HPD with 10-inch diameter has been fabricated and successfully tested at CERN. This Hybrid Photon Detector has a spherical entrance window and a bialkali photocathode. The fountain focusing optics produces a demagnified image (D = 4) on the round segmented silicon sensor. The signals of the 2048 cells are read out through analog front-end electronics encapsulated in the vacuum envelope. We report on the design, fabrication technique and the experimental results obtained with laboratory test benches. The large TOM HPD is a prototype tube developed for the CLUE cosmic ray experiment. The final tubes, now under development, will be equipped with a solar-blind Rb 2Te photocathode and self triggering front-end electronics. Keywords: Photodetector; Hybrid Photodiode; Hybrid Photon Detector; HPD; Photocathode; Bialkali; Rubidium Telluride; 1. Introduction Hybrid Photon Detectors (HPD) [1], also called Hybrid Photodiodes, are attractive devices when detection or imaging of low light levels is required. Combining the sensitivity known from conventional photomultiplier tubes with the superb spatial and energy resolution of silicon sensors, a number of appealing features is obtained: sensitivity to single photons with excellent signal definition, real photon counting, sub-millimeter spatial resolution. Proximity focused HPD tubes allow in addition for operation in magnetic fields. In high energy physics only few experiments have made use of the HPD technology, however, some large scale applications are in the prototype or construction phase. Over the last five years a CERN based team has built up dedicated facilities and infrastructure to design, fabricate and test HPDs. While the first development, the 5- inch Pad HPD [2,3], was designed for the readout Corresponding author, Christian.Joram@cern.ch of the LHCb RICH counters, the current developments open up applications in astrophysics and medical imaging. The 10-inch TOM HPD is the largest HPD ever built and is named after our former collaborator and pioneer of the Ring Imaging Cherenkov (RICH) technique, Tom Ypsilantis 2.TOMHPDs are planned to be used as focal plane detectors of the nine imaging air Cherenkov telescopes of CLUE (Cherenkov Light Ultraviolet Experiment) [4], situated on the Canarian island La Palma. The glass envelopes used for these developments were originally designed and fabricated as prototypes for the AQUARICH experiment [5]. They are therefore equipped with a standard glass entrance window. The operational conditions at CLUE require however a solar-blind photocathode, deposited on a quartz entrance window. The excellent sensitivity of Rb 2 Te cathodes on ITO undercoating, which we developed for this pur- 2 Tom Ypsilantis, 1928-2000.

2 pose, have been described in a recent paper [6]. In the current article we describe the design, the fabrication technique and the performance of the first sealed and fully operational 10-inch HPD. This first TOM HPD is equipped with a standard glass entrance window and bialkali photocathode. The purpose of this intermediate development step is the validation of the electron optical concept, photocathode evaporation and sealing technology. 2. Design of the 10-inch TOM HPD The TOM HPD makes use of the fountain shaped electron optics (see Figure 1), already applied in the 5-inch Pad HPD. The tube body with a height of about 275 mm, joint to a spherical (R curv = 200 mm) entrance window of 250 mm diameter, is manufactured in glass blowing tech- Figure 2. Photo of the 10-inch TOM HPD and the 5-inch Pad HPD. nique 3. The electric field is defined by 4 concentric ring electrodes (incl. a bleeder electrode very close to the entrance window). A baseplate of 160 mm diameter carries the silicon sensor and the readout electronics. The first TOM HPD is equipped with a silicon sensor of 50 mm diameter, segmented in 2048 pads and read out by 16 VA-prime 4 front-end chips with 350 ns shaping time, encapsulated in the vacuum envelope. In the final version the auto-triggering VATA chip will be used, which in recent tests demonstrated its design performance. The electron optical performance of the TOM tube has been studied with the SIMION 7.0 code 5. A linear demagnification over the full active diameter (ca. 228 mm) of about 4 is expected. The point spread function was predicted to be 1.3 mm for a cathode voltage of -20 kv [6]. 3. Fabrication Figure 1. Equipotentials and electron trajectories simulated with the SIMION code. The voltage settings of the electrodes are (in kv, from cathode to anode): -20, -19.6 (bleeder), -16, -13.5, -7, 0. The TOM HPD is fabricated by an external process in the CERN plant, which was originally built for the 5-inch Pad HPD [2,7]. Comprehensive modifications were required to mount the 3 SVT, France, www.svt-vacuum.com 4 IDE AS, Norway, http://www.ideas.no 5 ISS, USA, www.srv.net/ klack/simion.htm

3 large tube inside the vacuum tank. Three special heating elements, fully enclosing the glass envelope, provide the temperature levels required for bake-out (300 C) and cathode processing (150 C). The evaporation sources (Sb, K, Cs) are mounted on a movable platform. A ring mask screens the tube body from Sb vapors. During the cathode processing the platform is positioned close to the center of curvature of the tube entrance window. This is essential for the uniformity of the cathode thickness. The bialkali photocathode is produced in our standard co-evaporation process [2]. As the tube is expected to operate at very low intensity illumination (i.e. very small photocurrent), no conductive undercoating is deposited. After the cathode processing, the plant is cooled down to room temperature, the non evaporable getter is activated, and the tube body is in-situ sealed with the base plate by means of cold indium press seal. Figure 3. Quantum efficiency of the 10-inch TOM HPD. The drop below 300 nm is is due to the cutoff of the standard glass window (dotted line). 4. Performance The tube performance was assessed on two test benches. The first, comprising a Xe-lamp and a monochromator, allows to determine the quantum efficiency of the HPD in the wavelength range 200-800 nm. A calibrated UV photodiode (±3 % relative precision) serves as reference. The monochromatic light spot of about 3 mm diameter can be scanned over the tube surface to measure the uniformity of the response. In the second test bench the HPD is illuminated with a collimated spot (σ = 0.7 mm) from a H 2 flash lamp, which can be precisely scanned across the tube diameter. The pick-up signal from the flash lamp triggers the DAQ system to read the signals stored in the VA-prime chips. The average pedestal noise and its spread (σ noise )ofall 2048 electronic channels is measured and subtracted for all subsequent measurements (typically a 5σ noise cut is applied). The quantum efficiency of the TOM HPD is shown in figure 3. A peak value of 24% is achieved at 350 nm. The surface scan reveals a uniform response to a radius of 60 mm radius. A significant drop is observed at larger radii: R= 80 mm: -20%, R= 100 mm: -50%. This unexpected be- Figure 4. Pulse height spectrum of a single channel at a cathode voltage of -30kV. haviour is caused by the mask of the Sb source which was accidentally set too tight. The TOM HPD can be operated with very low noise count rates at cathode voltages up to -30 kv (currently limited by the available power

4 supplies). A pulse height spectrum of a single Si pad at this value is shown in figure 4. The single photoelectron peak is separated by more than 20σ noise from the pedestal noise. For all measurements presented below the light intensity was reduced to single photon level. Figure 5 demonstrates the HPD typical perfect linearity between signal amplitude (1 st photoelectron) and the applied cathode voltage. The linear fit intersects the abscissa at 0.96 kv, corresponding to an energy loss of the photoelectron of about 1 kev in the dead layers of the Si sensor (Al metalization and n + implant). In figure 6 the variation of the average charge (i.e. the integral under the 1 st photoelectron peak) and the random noise are plotted versus the level of the applied pedestal noise cut. Below 5 sigmas the influence of the electronics noise becomes dominant. A cut above 10 sigmas diminishes the signal charge and also the noise, as it consists mainly of diffuse background light and real dark counts from the photocathode, i.e. single photo electrons in both cases. The slight decrease of the signal charge between 3 and 10 sigmas is due to the suppression of so-called back Figure 5. Pulse height of the 1 st photoelectron peak versus cathode voltage. The intersection with the abscissa corresponds to the energy loss in the non-active back layer of the Si sensor. Figure 6. The average charge (integral under the 1 st photoelectron peak) and noise counts are shown as a function of the pedestal noise cut. The noise counts (dotted line, right scale) are measured per pad and per trigger. scattered photoelectrons. At U C =-25kVnoise values in the range of 1 2 10 4 per trigger and pad are obtained. Part of this is attributed to the halo of the light spot. The pure dark count rate of the total tube is of the order of 150 khz (ca. 450 Hz/cm 2 ). At U C = -25 kv and a 5 sigma noise cut the photoelectron detection efficiency is estimated to be 95%. The imaging properties of the TOM HPD are characterized by Figures 7 and 8. A radial scan of the light spot over the HPD reveals a linear demagnification of D = 4.02, constant up to a radius of about 100 mm and fully in agreement with the SIMION simulation. With the exception of the bleeder electrode (V bl = Vbl sim. 240V )all voltages are set to the values optimized in the simulation. The diameter of the Si sensor (R Si = 25 mm) prevents a measurement beyond R cath = 100 mm. The point spread function, defined as the Gaussian width of the charge distribution on the Si sensor measured with a pointlike light source, shows the expected 1/ U cath behaviour. The measured values are slightly higher than the simulated ones, e.g. at 20 kv 1.5 mm (measured) compared to 1.3 mm (simulated).

5 Figure 7. Relation between the radial coordinates, measured from the tube center, on the photocathode and the silicon sensor. The demagnification obtained from a linear fit is D =4.02. Figure 8. Point spread function, measured at the level of the silicon sensor, as a function of the applied cathode voltage. Acknowledgments 5. Outlook The final photodetector for the CLUE telescopes requires a Rb 2 Te cathode and a quartz entrance window. The significant mismatch of the thermal expansion coefficients of the quartz window and kovar metal excludes the fabrication of a tube of this size in the classical technique. We are currently pursuing two alternative strategies: (1) Fabrication of the whole tube in quartz 6, and (2) joining the quartz entrance window to the glass body by means of an Indium seal 7.Weexpect prototype tubes to be available by the end of 2003. In parallel a larger Si sensor (ca. 65 mm diameter) with a segmentation of about 4 4mm (ca. 256 pads) needs to be designed and fabricated. It will be read out by 2 VATA chips. 10- inch TOM HPDs matching the complete CLUE specifications can then be built in 2004. 6 Collaboration with Helios Italquartz SRL, www.heliositalquartz.com 7 Collaboration with PHOTEK LTD, www.photek.co.uk We would like to thank our technical personnel at CERN for excellent support in the preparation of the HPD components: C. David and R. Dye (cleaning, vacuum evaporations, mechanics), M. Malabeila and M. Thiebert (electro chemical depositions), K. Mühlemann and I. Mcgill (Si sensor and electronics bonding). REFERENCES 1. C. Joram, Nucl. Pyhs. B (Proc. Suppl.) 78 (1999) 407 2. A. Braem et al. Nucl. Instr. Meth. A442 (2000) 128. 3. A. Braem et al, Nucl. Instr. Meth. A478 (2002) 400. 4. A. Alexandras et al., Nucl. Instr. Meth. A409 (1998) 488. 5. P. Antonioli et al, Nucl. Instr. Meth. A433 (1999) 104. 6. A. Braem et al., Nucl. Instr. Meth. A504 (2003) 19. 7. A. Braem et al. Nucl. Instr. Meth. A502 (2003) 205.